NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

Similar documents
You need the following to set up and use your terminal block:

INSTALLATION INSTRUCTIONS LFH160 Cable

TBX-96 TERMINAL BLOCK

SCXI HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK

NI 6521 Specifications

NI SMB-2145/2146/2147/2148

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

NI 653x Cable Adapter

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

Getting Started with the NI 8234

LabVIEW DSP Module. Contents. Introduction RELEASE NOTES. Version 1.0

NI SD Card Memory Module

FP-PS-4. Features. Installation

Getting Started with NI-Motion for NI 73xx Motion Controllers

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module

FP-AO-210 AND CFP-AO-210

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

Getting Started with the NI PCI-1405

Compact FieldPoint cfp-cal

USER GUIDE SC-2075 SIGNAL CONDITIONING ACCESSORY

FP-AO-200 AND CFP-AO-200

NI PCIe-8255R Quick Start Guide

Getting Started with R Series Intelligent DAQ

Getting Started with the NI PCIe-8255R

Getting Started with the NI PCIe-1433

Getting Started with the NI PCI-8254R

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

Calibrating FieldPoint Analog Input Modules with Calibration Executive

Getting Started with the NI PXI/PCIe-8231

Getting Started with the NI PCIe-8253

Getting Started with the NI PCIe-8235

Getting Started with the NI 8234

Getting Started with R Series Multifunction RIO

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

Caution Electrostatic discharge can damage your controller. To avoid such damage, handle the controller only in a proper ESD-controlled environment.

Getting Started with the NI PXI/PCI-1422

Getting Results with the NI PXI-6585R

NI Channel, 0 20 ma, 16-Bit Analog Current Output Module

Compact FieldPoint cfp-1808

FP-AIO-600 and cfp-aio-600

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sinking Digital Input Device

Getting Results with the NI 5752R

VME-GPIB Installation and User Guide

NI 9213 Calibration Procedure

QUICK START GUIDE. What You Need to Get Set Up

FieldPoint cfp-21xx. Quick Start Guide. What You Need to Get Set Up

Getting Started with the NI PXI/PCI-1409

USER GUIDE Universal Motion Interface (UMI)-7764

NI CAN Demo Box. NI CAN Demo Box User Guide. Power supply (+9 VDC to +12 VDC) 68-pin Multifunction Data Acquisition board

LabVIEW DSP Module Release and Upgrade Notes

SH Cable Specifications

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, 0 20 ma, 16-Bit Analog Current Output Module

FP-2000/2010 FieldPoint Quick Start Guide

Electrical. SPECIFICATIONS SH Cable

NI SPEEDY-33. '7 NATIONAL INSTALLATIONGUIDE. P~ClCl J ~ Ig~~!1 "INSTRUMENTSN. 1~~~~~~g~~lm.OOOQ{JOOO,

TBX-1316 High-Voltage Attenuator Terminal Block

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sourcing Digital Output Device

Sample. LabWindows TM /CVI TM Core 1 Exercises Manual

NI 6584R User Guide and Specifications

NI USB-9201/9221. Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 12-Bit Analog Input Devices

CompactRIO Reconfigurable Embedded Chassis

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

Sample. LabWindows TM /CVI TM Core 1 Course Manual

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

NI 6520/6521. Contents USER GUIDE

CB-27T, TBX-68T, AND CB-68T ISOTHERMAL TERMINAL BLOCKS INSTALLATION GUIDE

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

For NI PXI and NI SCXI Switch Modules

NI CardBus-8310-to-PXI Expansion Kit

8x16, 2-Wire Terminal Block for the NI PXI The following conventions are used in this guide:

Getting Started with the NI EVS-1463

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

Safety. Introduction

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

Instructions. (For 6180 Industrial Computers) Applications. Overview & Safety

Power Analyzer Firmware Update Utility Version Software Release Notes

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

Sample. LabVIEW TM Core 1 Exercises. Course Software Version 2010 August 2010 Edition Part Number B-01. LabVIEW Core 1 Exercises

Models 2634B, 2635B, and 2636B System SourceMeter Instruments Quick Start Guide

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4357 and TB-4357

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

Instructions. (For 6180 Industrial Computers) Installing a Processor Upgrade

SCB-68 User Guide. 68-Pin Shielded Desktop Connector Block

8510 AC Spindle Drive Hardware/Firmware Replacement

CALIBRATION PROCEDURE CAL Contents. Software

SCC-RLY01 Relay Module

NI USB Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. 10 MHz to 18 GHz RF Power Meter

SCXI -1313A Terminal Block

Electromagnetic Compatibility Guidelines

Transcription:

INSTALLATION GUIDE NI CB-7F-LP Connector Block for 7-Pin D-Sub Devices Introduction This installation guide describes how to install and connect signals to the NI CB-7F-LP connector block for use with devices with a 7-pin D-Sub connector. The CB-7F-LP is a connector block assembly consisting of a printed circuit board and 0 screw terminals. The connector block assembly connects directly to the front panel of National Instruments 7-pin D-Sub devices, eliminating the need for an external cable. It also can be cabled using a 7-pin cable. The CB-7F-LP allows you to easily connect analog input, analog output, counter/timer, and digital I/O signals to your National Instruments device. The 0 screw terminals allow access to every pin on the connector, plus three shield screw terminals for use with a shielded cable. Caution The CB-7F-LP is not designed for input voltages greater than 2 V pk, even if you install a voltage divider that reduces the voltage to within the input range of the DAQ device. Input voltages greater than 2 V pk can damage the CB-7F-LP, any device connected to it, and the host computer. Overvoltage also can cause an electric shock hazard for the operator. National Instruments is not liable for damage or injury resulting from such misuse.

What You Need to Get Started Safety Information You need the following to set up and use your connector block: NI CB-7F-LP Connector Block Assembly NI CB-7F-LP Installation Guide One of the following: NI 6010 device NI 6510/6516/6517/6518/6519 device NI 6010 Help or Digital I/O Help for NI 6509/651x /6528 Devices 0.10 in. slotted screwdriver Wire cutters Wire insulation stripper Number 1 Phillips screwdriver SH7F-7M cable (if not mounting directly to the NI device) Cautions Do not operate the device in an explosive atmosphere or where there may be flammable gases or fumes. Do not operate damaged equipment. The safety protection features built into this device can become impaired if the device becomes damaged in any way. If the device is damaged, turn the device off and do not use it until service-trained personnel can check its safety. If necessary, return the device to National Instruments for service and repair to ensure that its safety is not compromised. Do not operate this equipment in a manner that contradicts the information specified in this document. Misuse of this equipment could result in a shock hazard. Do not substitute parts or modify equipment. Because of the danger of introducing additional hazards, do not install unauthorized parts or modify the device. Return the device to National Instruments for service and repair to ensure that its safety features are not compromised. You must insulate all signal connections to the highest voltage with which the CB-7F-LP can come in contact. NI CB-7F-LP Installation Guide 2 ni.com

Connections, including power signals to ground and vice versa, that exceed any of the maximum signal ratings on the connector block can create a shock or fire hazard, or can damage any or all of the boards connected to the host computer, and the connector block. National Instruments is not liable for any damages or injuries resulting from incorrect signal connections. Clean the device and accessories by brushing off light dust with a soft non-metallic brush. Remove other contaminants with a stiff non-metallic brush. The unit must be completely dry and free from contaminants before returning it to service. Connecting the Signals Refer to the help file for the NI 7-pin device for a list of signals available on the CB-7F-LP. Refer to Figures 1 and 2 as you complete the following steps to connect signals to the connector block. 1 2 5 1 Signal Wires 2 Screw Terminals Connector Block Mounting Screw Holes Rubber Feet 5 Connector Figure 1. CB-7F-LP Parts Locator Diagram National Instruments Corporation NI CB-7F-LP Installation Guide

CB 7F LP FOR PATENTS: NI.COM\PATENTS J5 S/N ASSY192710A J1 1 20 2 21 22 2 5 SHIELD 10 28 9 27 8 26 7 25 6 2 1 2 1 1 12 0 11 29 SHIELD SHIELD 19 7 18 6 17 5 16 15 ' COPYRIGHT 2005 J1 J2 MADE IN U.S.A. J J Figure 2. CB-7F-LP Top View 1. Use wire cutters and wire insulation strippers to strip no more than 7 mm of insulation from the wire ends. 2. Loosen the screws in the screw terminals with the 0.10 in. slotted screwdriver.. Insert the stripped wires into the screw terminals, and tighten the screws with the 0.10 in. slotted screwdriver. No bare wire should extend past the screw terminal. Exposed wire increases the risk of short circuits and failures. NI CB-7F-LP Installation Guide ni.com

Mounting the Connector Block to the Device Refer to Figure as you complete the following steps to mount the connector block on the PCI device I/O connector. 2 1 1 Connector Block Mounting Screw 2 CB-7F-LP 7-Pin NI Device Computer Figure. Mounting the CB-7F-LP to a 7-Pin Device Caution The connectors of both the PCI device and the connector block are polarized. You can attach them in only one way. Do not force the connector block when inserting it into or removing it from the PCI device I/O connector. Make sure that the computer is powered off before inserting the PCI device. 1. Install the PCI device into the computer as described in the DAQ Quick Start Guide. You must install the CB-7F-LP connector block on the PCI device after the device is installed in the computer. Caution The CB-7F-LP is not designed for input voltages greater than 2 V pk, even if you install a voltage divider that reduces the voltage to within the input range of the DAQ device. Input voltages greater than 2 V pk can damage the CB-7F-LP, any device connected to it, and the host computer. Overvoltage also can cause an electric shock hazard for the operator. National Instruments is not liable for damage or injury resulting from such misuse. 2. Install the CB-7F-LP on the PCI device by screwing in both connector block mounting screws with the Phillips screwdriver. National Instruments Corporation 5 NI CB-7F-LP Installation Guide

Cabling the Connector Block to the Device If you do not mount the connector block to the PCI device, you must use a cable to connect the CB-7F-LP to the device. Refer to Figure as you complete the following steps to connect the connector block to the PCI device I/O connector. 2 1 1 CB-7F-LP 2 SH7F-7M Cable 7-Pin NI Device Computer Figure. Connecting the CB-7F-LP to a 7-Pin Device with a Cable Caution The connectors of both the PCI device and the connector block are polarized. You can attach them in only one way. Do not force the cable when inserting it into or removing it from the PCI device I/O connector or the CB-7F-LP. Make sure that the computer is powered off before inserting the PCI device. 1. Install the PCI device into the computer as described in the DAQ Quick Start Guide. You must make the connection between the CB-7F-LP and PCI device after the device is installed in the computer. 2. Connect the SH7F-7M cable to the PCI device I/O connector.. Connect the other end of the cable to the CB-7F-LP connector. NI CB-7F-LP Installation Guide 6 ni.com

Caution The CB-7F-LP is not designed for input voltages greater than 2 V pk, even if you install a voltage divider that reduces the voltage to within the input range of the DAQ device. Input voltages greater than 2 V pk can damage the CB-7F-LP, any device connected to it, and the host computer. Overvoltage also can cause an electric shock hazard for the operator. National Instruments is not liable for damage or injury resulting from such misuse. Specifications This section lists the specifications of the CB-7F-LP. These specifications are typical at 25 C unless otherwise specified. Input/Output Physical Refer to the documentation for your NI PCI-6010 device to determine the input/output specifications for your application. Dimensions... 5.7 8.11 1.17 cm (2.257.19 0.558 in.) I/O connector... One 7-pin female D-Sub connector Screw terminals Number... 0 Type... Angled entry,.91 mm pitch Environment Operating temperature... 0 to 55 C Storage temperature... 20 to 70 C Relative humidity... 10 to 90% noncondensing Pollution Degree... 2 Altitude... 2,000 m Indoor use only. National Instruments Corporation 7 NI CB-7F-LP Installation Guide

Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1 CAN/CSA-C22.2 No. 61010-1 Note For UL and other safety certifications, refer to the product label, or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. NI CB-7F-LP Installation Guide 8 ni.com

Where to Go for Support The National Instruments Web site is your complete resource for technical support. At ni.com/support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-50. National Instruments also has offices located around the world to help address your support needs. For telephone support in the United States, create your service request at ni.com/support and follow the calling instructions or dial 512 795 828. For telephone support outside the United States, contact your local branch office: Australia 1800 00 800, Austria 0 662 5 79 90 0, Belgium 2 0 2 757 00 20, Brazil 55 11 262 599, Canada 800 88, China 86 21 6555 788, Czech Republic 20 22 25 77, Denmark 5 5 76 26 00, Finland 85 0 9 725 725 11, France 0 1 8 1 2 2, Germany 9 0 89 71 1 0, India 91 80 51190000, Israel 972 0 6977, Italy 9 02 1091, Japan 81 572 2970, Korea 82 02 51 00, Lebanon 961 0 1 28 28, Malaysia 1800 887710, Mexico 01 800 010 079, Netherlands 1 0 8 66, New Zealand 0800 55 22, Norway 7 0 66 90 76 60, Poland 8 22 90150, Portugal 51 210 11 210, Russia 7 095 78 68 51, Singapore 1800 226 5886, Slovenia 86 25 200, South Africa 27 0 11 805 8197, Spain 91 60 0085, Sweden 6 0 8 587 895 00, Switzerland 1 56 200 51 51, Taiwan 886 02 277 2222, Thailand 662 992 7519, United Kingdom 0 165 5255 National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 2005 National Instruments Corporation. All rights reserved. 7158A-01 Apr05