General Specifications. P2-08THM Analog Input

Similar documents
General Specifications. P2-08NTC Thermistor. The P2-08NTC module provides eight Thermistor input channels for use with the Productivity2000 System.

General Specifications. P2-8AD4DA-2 Analog Input/Output

P2-04AD Analog Input. Removable Terminal Block Specifications

P2-04DA Analog Output. Removable Terminal Block Specifications

P2-16AD-2 Analog Input. Connector Specifications

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications

P3-08RTD Analog Input

Removable Terminal Block Specifications

P2-HSO High-Speed Isolated Sinking/Sourcing Output. Connector Specifications

General Specifications. P2-SCM Serial Communications

P3-SCM. General Specifications

P3-RS Remote Slave. Remote Slave Specifications. The P3-RS is a full-featured, highperformance,

P1-540 CPU. CPU Specifications

Analog Voltage Combination Module

Thermocouple / Millivolt Input Module HE800THM000 / HE800THM100 HE-THM000 / HE-THM100* * HE- denotes plastic case.

Temperature I/O Module HE800MIX963 / HE-MIX963* * HE- denotes plastic case.

SCXI -1313A Terminal Block

CompactLogix Power Supplies Specifications

ICS Regent. Thermocouple Input Assembly. Input Module, Mux, Termination Panel and Cable (T3431-IM, T3431-Mux, T3431-TP and T3431-CA) PD-6024

Tempco Instruction Manual

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

Digital ac/dc (24V) Input Module

P3-530 CPU. CPU Specifications. The P3-530 is a high-performance CPU for use with the Productivity3000 Programmable Automation Controller.

Digital ac/dc (24V) Input Module

POINT I/O Family. Chapter. Overview

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Chapter 1 Introducing the OM-USB Functional block diagram... 5

FLEX Ex Spring Clamp Terminal Base

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 4-20mA Analog In/Out HE800MIX902 / HE-MIX902* * HE- denotes plastic case.

SMVector Additional I/O Module Installation and Operation Manual

CTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 1.3 CTI Part # * *

Environmental Specifications CompactLogix Controllers and Compact GuardLogix 5370 Controllers

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Analog Input, 16-Bit Thermocouple Module

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SCXI OFFSET-NULL AND SHUNT-CALIBRATION HIGH-VOLTAGE TERMINAL BLOCK INSTALLATION GUIDE

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 0-20mA Sourcing Analog In/ Out HE800MIX906 / HE-MIX906* * HE- denotes plastic case.

Component identification

5504 Thermocouple Analog Input Module

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

VersaMax* Analog Input, 16-Bit Thermocouple Module

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

USB-2001-TC. USB-based Thermocouple Input. User's Guide

Communication & Networking

Twido Programmable Controllers

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

TBX-1316 High-Voltage Attenuator Terminal Block

Analog Input Module. ST-3xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

VIBRATION MONITOR CX-RLY

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Analog Input/Output Modules

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Model 3750 Multifunction I/O Card

DINALOG A 144 x 36 A1400 Light-Strip Indicator

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

TC100 Precision Thermocouple Calibrator

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

4-20 ma Analog Input Module HE800ADC020 / HE800ADC120 HE-ADC020* / HE-ADC120* 12-Bit Resolution * HE-denotes plastic case.

Model 3724 Dual 1x30 FET Multiplexer Card

CompactBlock Guard I/O EtherNet/IP Safety Modules

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

CONTROL MICROSYSTEMS Thermocouple Analog Input Module. Hardware Manual

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

S66 Series Electronic Fan Speed Control

ProSense DPM2 Series. Digital Panel Meter. User Manual. for process, temperature and resistance input signals. Models: DPM2-AT-HL DPM2-AT-2R-HL

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

TCP A3. Description. Module with 3 thermocouple inputs. Datasheet

Analog Monitor Installation Manual

Installation Instructions

PanelView Plus/VersaView CE Terminals and Display Modules

Isolated Process Current Input with Loop Power 7B35

DeltaV Bulk Power Supplies

Signal Doublers. VariTrans A 20300

SCC-AO10 Isolated Analog Output Module

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

WLS-TC Specifications

P3-RS Remote Slave Module

ROC800-Series Thermocouple Module

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

USER'S MANUAL DCL-650

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

1734 POINT I/O POINT I/O. Benefits. Product Design. POINT I/O System Components

TRC-190 User s Manual

PCI 2 Axis Servo Card

Trident and Trident X2 Digital Process and Temperature Panel Meter

DIGITAL PANEL THERMOMETER

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

Transcription:

General Specifications Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Heat Dissipation Enclosure Type Agency Approvals Module Keying to Backplane Module Location Field Wiring EU Directive Connector Type (included) Weight 0º to 60ºC (32º to 140ºF) -20º to 70ºC (-4º to 158ºF) 5 to 95% (non-condensing) No corrosive gases permitted IEC60068-2-6 (Test Fc) IEC60068-2-27 (Test Ea) 1800VAC applied for 1 second 500mW Open Equipment UL508 File E139594, Canada & USA CE (EN61131-2*) Electronic Any I/O slot in a Productivity2000 System Removable terminal block (included). The P2-08THM module is not compatible with the ZIPLink wiring system. See the EU Directive topic in the Productivity2000 Help File. Information can also be obtained at: 18-position removable terminal block 90g (3.2 oz) *Meets EMC and Safety requirements. See the D.O.C. for details. 1 OVER 2J 0526 C 3E 1000 F 4 UNDER 5 OVER M 6 21.35 V M 7 1.245 V 8 SPARE 2000 P2-08THM Analog Input The P2-08THM Thermocouple Input Module provides eight differential channels for receiving thermocouple and voltage input signals for use with the Productivity2000 System. General Specifications... 1 T/C Input Specifications... 2 Voltage Input Specifications... 2 Configuration/Diagnostics... 2 Wiring Diagram and Schematic... 3 Module Installation Procedure... 4 QR Code... 4 Hot Swap Information... 4 Wiring Options... 5 Module Configuration... 5 Typical Application Example... 6 OLED Panel Display Menus... 7 Warning... 8 Removable Terminal Block Specifications........ 8 Sales 800-633-0405 Terminal Block Included. Not Compatible with ZIPLink. Warranty: Thirty-day money-back guarantee. Two-year limited replacement. (See for details). 1

T/C Input Specifications Input Channels 8 Differential Data Format Common Mode Range Common Mode Rejection Input Impedance Floating Point ±1.25 V 100dB @ DC and 130dB @ 60Hz >5MΩ Maximum Ratings Fault protected inputs to ±50V Resolution 16-bit, ±0.1 C or F Type J -190 to 760 C (-310 to 1400 F); Type E -210 to 1000 C (-346 to 1832 F); Type K -150 to 1372 C (-238 to 2502 F); Type R 65 to 1768 C (149 to 3214 F); Thermocouple Input Ranges Type S 65 to 1768 C (149 to 3214 F); Type T -230 to 400 C (-382 to 752 F); Type B 529 to 1820 C (984 to 3308 F); Type N -70 to 1300 C (-94 to 2372 F); Type C 65 to 2320 C (149 to 4208 F); Cold Junction Compensation Automatic Thermocouple Linearization Automatic Accuracy vs. Temperature ±50ppm per C (maximum) Linearity Error ±1 C maximum (±0.5 C typical) Monotonic with no missing codes Maximum Inaccuracy ±3 C maximum (excluding thermocouple error) (including temperature drift) Warm-up Time 30 minutes for ±1% repeatability 2 minutes to reach voltage specifications Sample Duration Time 270ms All Channel Update Rate 2.16 s Open Circuit Detection Time Within 2s Conversion Method Sigma-Delta External DC Power Required None Voltage Input Specifications 0-39.0625 mvdc, +/-39.0625 mvdc, +/-78.125 mvdc, Linear mv Device Input Ranges 0-156.25 mvdc, +/-156.25 mvdc, 0-1250 mvdc Max Voltage Input Offset Error 0.05% @ 0-60 C, typical 0.04% @ 25 C Max Voltage Input Gain Error 0.06% @ 25 C Max Voltage Input Linearity Error 0.05% @ 0-60 C, typical 0.03% @ 25 C Max Voltage Input Impedance 0.2% @ 0-60 C, typical 0.06% @ 25 C Configuration/Diagnostics Burn-out Detection: High Side/Disable C/ F (T/C Only) Module Diagnostics Failure Burn-out (on if T/C input is open no connection between TCn+ and TCn-) Channel Under-range (T/C only) Channel Over-range (T/C only) 1 bit per module 1 bit per module 1 bit per module 1 bit per channel 1 bit per channel 1 bit per channel 2 Tech Support 770-844-4200

Wiring Diagram Schematic Thermocouple Input Circuits Voltage Input Circuits Ungrounded/Shielded Thermocouple Grounded/Shielded Thermocouple Infrared Thermocouple 4-wire Voltage Transmitter AC or DC Load Cell or Strain Gauge AC or DC Transmitter Power Supply Excitation Power Supply Voltage Divider TC1+ TC1- TC2+ TC2- TC3+ TC3- TC4+ TC4- TC5+ TC5- TC6+ TC6- TC7+ TC7- TC8+ TC8- INTERNAL MODULE CIRCUITRY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 CH1 T/C CH2 T/C CH3 T/C CH4 T/C CH5 T/C CH6 T/C CH7 T/C CH8 T/C NOTES: 1. Connect shield to thermocouple signal/ground only. Do not connect to both ends. 2. Install jumper wire on each unused input, to. 3. With grounded thermocouples, take precautions to prevent having a voltage potential between thermocouple tips. A voltage of 1.25V or greater between tips will skew measurements. 4. Use shielded, twisted thermocouple extension wire that matches the thermocouple type. Use thermocouple-compatible junction blocks. Sales 800-633-0405 3

Module Installation QR Code WARNING: Do not apply field power until the following steps are completed. See hot-swapping procedure for exceptions. 2 rotate to seated position Step One: Align module catch with base slot and rotate module into connector. Step Two: Pull top locking tab toward module face. Click indicates lock is engaged. Locked 1 Align with slot Unlocked Use any QR Code reader application to display the module s product insert. Step Three: Attach field wiring to terminal block. WIRE STRIP LENGTH Caution: If possible, remove field power prior to proceeding. If not, then EXTREME care MUST be taken to prevent damage to the module, or even personal injury due to a short circuit from the live terminal block. Important Hot-Swap Information The Productivity2000 System supports hot-swap! Individual modules can be taken offline, removed, and replaced while the rest of the system continues controlling your process. Before attempting to use the hotswap feature, be sure to read the hot-swap topic in the programming software s help file or our online documentation at AutomationDirect.com for details on how to plan your installation for use of this powerful feature. 4 Tech Support 770-844-4200

Wiring Options 1 Screw Terminal Block (Included) P2-RTB (Quantity 1) Module Configuration Using the Hardware Configuration tool in the Productivity Suite programming software, drag and drop the P2-08THM module into the base configuration. Select Automatic Module Verification or No Verification and Enable Hot Swap. Specify Temperature Scale and Burnout Detection, and use the drop down menu to select module range and resolution. If desired, assign a User Tagname to each input point (channel) selected and to each Status Bit Item. 2 Spring Clamp Terminal Block P2-RTB-1 (Quantity 1) Sales 800-633-0405 5

Typical Application Example User s Desired Setpoint Output PID Heat Controller Heater er Process Variable (feedback) Oven Temperature Thermocouple to P2-08THM P2-08THM Module 6 Tech Support 770-844-4200

OLED Panel Display Power On PASSED SELF TEST These screens will then auto cycle P2-08THM Fw. Rev. 1.00 16-BIT 7 CH ENABLED Appears initially Hold SEL button down to cycle through primary screens. Release button to select screen. DISPLAY SETUP INFO This screen will auto cycle with status information End of Status Menu List Error Messages: An existing error will be inserted into the cycling Status Info screen. DISPLAY STATUS INFO Momentarily Press SEL button to toggle through secondary displays DISPLAY UNITS DECIMAL COUNTS 1J 000 F 2E 000 F 3 00.0mV 4 0.000V 5 00.0mV 6 00.0mV 7 00.0mV 8 SPARE Note: Volts, Celsius, or Fahrenheit values are specified with the P2-08THM Module Options configuration dialog box in Productivity Suite software. Note: SPARE denotes deselected channel. SELFTEST FAIL REPLACE MODULE 1J 000 F 2E 000 F 3 00.0mV 4 0.000V 5 00.0mV 6 00.0mV 7 00.0mV 8 SPARE MISSING CONFIG DATA End of Status Menu List Fault Messages Appear in place of data during a fault condition. 1 OVER 2 UNDER 3 OPEN 4 Measured temperature > max. temperature of selected range. Measured temperature < min. temperature of selected range. Input signal is OPEN circuit. (Thermocouple only) Sales 800-633-0405 7

WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and it is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call Technical Support at 770-844-4200. This publication is based on information that was available at the time it was printed. At AutomationDirect.com we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product. Removable Terminal Block Specifications Part Number P2-RTB (included) P2-RTB-1 Number of positions 18 Screw Terminals 18 Spring Clamp Terminals 30-16 AWG (0.051-1.31 mm²) 28-16 AWG (0.081-1.31 mm²) Wire Range Solid / Stranded Conductor Solid / Stranded Conductor 3/64 in. (1.2 mm) Insulation Maximum 3/64 in (1.2 mm) Insulation Maximum 1/4 in (6-7 mm) Strip Length 19/64 in (7-8 mm) Strip Length Conductors Use Thermocouple Extension wire for thermocouples. Use copper conductors, 75 C or equivalent for millivolt inputs. Screw Driver Width 1/8 in (3.8 mm) Maximum Screw Size M2 N/A Screw Torque 2.5 lb in (0.28 N m) N/A Document Name Edition/Revision Date P2-08THM-DS 1st Ed. 8/15/2014 Copyright 2014, AutomationDirect.com Incorporated/All Rights Reserved Worldwide 8 Tech Support 770-844-4200