Softing Industrial Automation Data Exchange & Network Diagnostic Solutions Ethernet Cable Testing, Certifying & Diagnostics Jim Ralston Director of Sales
Topics Softing Introduction Industrial Network Trends Risks to Production Poor/Degrading Network Infrastructure Best Practices for Ethernet Cabling What is Certification? What is Qualification? Advanced Network Monitoring Tools Preventive maintenance Questions
Softing in North America Softing (German publicly traded company) 30 years industrial networking technology leader (Automation & Automotive) Acquired OLDI in May 2014 Original Developer/Manufacture Rockwell Partner Expertise Embedded Fieldbus protocol stacks Automotive diagnostic systems OPC & OPC-UA (development tools & servers) Advanced networks testing & monitoring Products: Data Exchange Solutions Network Diagnostic Tools
Softing Worldwide Softing AG Munich, Germany Softing Inc. Boston, MA Sales/Service Knoxville, TN Headquarters US Headquarters in Knoxville, TN Sales Product Marketing Development Training
Products sold through the Rockwell Automation Channel Move Data Run Custom Code Certify/ Qualify Cable Monitor Networks eatm Enterprise Appliance Transaction Modules catm Controller Appliance Transaction Modules SAM Special Application Modules WireXpert Advanced Cable Certifier NetXpert 1G Qualifier & Troubleshooter TH Scope; TH Link Monitor; Diagnose EtherNet/IP and other networks ControlLogix
Industrial Automation Hot Trends Big Data Need for more reliable data collection/storage OPC-UA data security & standardization Industrial Ethernet growth continues OT/IT convergence Need for diagnostic monitoring & quick repairs Following industry standards (TIA 568) IT/Data Center Faster Standards CAT 6, CAT 6A CAT 8 soon.
Industrial Ethernet Why is Cable Certification Important? Yesterday Today Emerging Tomorrow Network DH485 DH+ DH-RIO Device Net Data Rate (mbit) Control Net EtherNet/IP (10/100) Ethernet/IP (1000) EtherNet/IP (10G).0192.0576.23.5 5 10 or 100 1,000 10,000 12000 10000 8000 6000 4000 2000 0 0.0192 0.0576 0.23 0.5 5 55 1000 10,000 DH485 DH+ DH-RIO DeviceNet Control EtherNet/IP Ethernet/IP EtherNet/IP (10G)? Data Rate (mbps)
Why is Complete Cable Testing Important?.. As network bandwidth (data rate) increases.. Carrier frequency increases Impedance (attenuation) increases Signal/noise ratios tighten Crosstalk between pairs increase High frequency signals traveling over copper Poor wiring = poor network performance (DOWN TIME) DC Continuity (zero baud) is not a complete test!
Proper Cabling Practices Reduce Risk According to an ISA.org online article, Physical Layer (structured cabling) failures accounted for 35% of total failures in plant automation. Physical deterioration, electrical failure, or poor installation and maintenance practices can all lead to unreliable network performance. loss of critical data system downtime even catastrophic failure
Best Practices for Ethernet Testing When installing cabling for industrial Ethernet applications, don t just assume it is going to work. Proper installation, configuration, testing and certification will greatly reduce any start up problems and minimize future downtime.
Best Practices for Ethernet Testing What are the cable Gotcha s It is easier to terminate an Ethernet outlet than plug RJ45 outlets are used in patch panels & wall outlets Jack to jack wiring = permanent link Patch cords (with RJ45 plugs) connect equipment to outlet If plugs wear out, replace the cable! If the patch cable is LONG (e.g. run through conduit), repair time is LONGER
Best Practices for Ethernet Testing What are the cable Gotcha s Connector termination issues Obvious miswiring/shorts/opens Shield not connected Precision terminations to limit de-pairing Cross talk/noise too high
Best Practices for Ethernet Testing What are the cable Gotcha s Cable installation issues Too close to other cables or electrical equipment (noise) Cable (pairing) damaged Bend radius exceeded Cable crush/kinked Tie wraps used!!!! Cable is too long Cable is defective (counterfeit?)
What Certification is All About Ensuring that the cable infrastructure MEETS the standards The network DEPENDS on Layer One! Reducing start-up time Reducing finger pointing when network problems arise 80+% of industrial network problems are cabling oriented! A REQUIREMENT for the manufacturers warranty (Belden, etc) Certification is PART of the TIA 568 standard! Certification is the NORM for commercial installations why not industrial? Certifiers also make excellent troubleshooting tools reduce downtime
What is required to Certify a cable? 190,000 different measurements needed to Certify! Measurement Dynamic Wiremap Loop Resistance Cable Length Near End Crosstalk (NEXT) PowerSum NEXT Insertion Loss (Attenuation) ACR-N PowerSum ACR-N Return Loss (RL) ACR-F (ELFEXT) PowerSum ACR-F Propagation Delay Delay Skew Description Accurately detects Open/Short and Distance to Fault from both ends of the cable The resistance between the two conductors of a twisted pair which is looped back at the far end The length of the cable under test The interference at the near end of a pair caused by signal on another pair The sum of the individual NEXT effects on each pair by the other three pairs The decrease in signal strength from one end of the cable to the other The difference between insertion loss and near-end crosstalk (NEXT) The sum of the individual ACR-N effects on each pair by the other three pairs Signal loss caused by structural imperfections in the cable The interference at the far end of a pair caused by signal on another pair, with the insertion loss subtracted The sum of the individual ACR-F effects on each pair by the other three pairs Time it takes for a signal to travel from one end of a cable to the other The difference in time between the fastest and slowest pairs within a cable Each cable test collects 190,000 data measurements!!!!
What is required to Certify a cable?
Fastest, Most Accurate, User Friendly and Future Proof Cable Certifier on market!
WireXpert Advanced Cable Certifier Certifies and tests: CAT 5e, 6 and 6A (CAT 8) Copper Standards Multi-mode and Single Mode Fiber RJ45 & M12 connectors Documents and reports cable/connector manufacture models Produces Certification Reports
What Does Certification Measure? What tests are performed? 9 seconds Autotest Pass or Fail on display Wiremap & crosstalk data on display Location to fault Data downloadable to PC Formal reports
export - Professional cable test management software Quickly organize, edit, view, print, save, or archive test results by jobsite, customer, campus building, and more Deliver professional, customized (your company s logo), graphical test results Export in summary or graphical layout, all or any number of tests, to either.csv or.pdf format
Example Cable Certification Report
Ethernet Cable Qualification Qualification is NOT Certification, but Cable Qualifiers: Use many of the same measurement methods as certifiers Identify cable issues and location of faults May perform additional online tests DO NOT produce certification reports But may offer other useful reports Qualifiers cost less than Certifiers may fit the budget! PROFIBUS Diagnostics
Cable Testing, Speed Testing, Network Testing
Gigabit Cable Qualifier and Network Diagnostic Tool Qualifies data cabling for IEEE 802.3 compliance at transmission rates of up to 1Gbit/s (BERT) Determines signal-to-noise ratio (SNR) Measures delay skew Performs full TDR for pair length and distance to fault measurements Full-color wire map shows opens, shorts, miswires, and split pairs Results can be saved in the unit and standardsbased reports generated
Network Testing and Diagnosis Link test up to 1 Gbit/s to identify link capability and link status Ping to a single or lists of IPv4 and IPv6 as well as any URL on the internet CDP/LLDP/NDP and VLAN discovery PoE / PoE+ detection and load test for voltage drop DHCP test Traceroute Switch Port identification by blinking the port LED
NetXpert Products Product Description NetXpert 1400 NetXpert 1400 network/cabling qualifier; IEEE 802.4 testing up to 1Gbit/s; Tests ethernet, coax, audio; security cables; w report sw NetXpert RJ45 to M12 cable 1 meter, RJ45 to M12 D-Code
Advanced Network Monitoring Online Diagnostic Benefits Early detection of problems Preventing production downtime Simple error detection and correction Also usable by non-experts (maintenance) PROFIBUS Diagnostics
TH Scope and TH Link Monitoring Solution TH Scope with TH Link(s) are intended to inform users of network health in an easy-to-understand manner TH Link modules connect directly to networks and their built in webservers provide basic network info TH Scope is a software package that enables additional monitoring beyond the built-in webservers
TH Link Connection Options Separate subnet with no routing/switching between Ports Industrial Ethernet model also supports Modbus TCP & PROFINET devices
TH Link Network Monitoring Basic Monitoring with TH LINK Early error detection and correction Email alarm in case of problem or fault Access through web browser
TH Link Network Monitoring
TH Scope Network Monitoring Advanced Diagnostics with TH SCOPE PC-Software for monitoring and maintaining industrial networks Inventory Visualizes collected data from multiple TH LINK gateways Supports maintenance work processes (trend view, reference comparison, data export, printing) Integrates existing applications (OPC Server, SNMP Agent, web link) Cross-protocol information analysis, PROFINET, standard Ethernet TCP/IP, Modbus TCP, Ethernet/IP
TH Scope Network Monitoring Advanced Diagnostics with TH SCOPE (optional) Additional Features Trend The trend feature provides a summary of the network quality over a time period of up-to one month Topology PROFINET The topology features provides a clear and accurate overview of the network infrastructure
TH Scope Error Statistics
Thank You! Questions See us at Booth 222 for a demo! Jim Ralston 724-554-8498 Jim.Ralston@softing.us www.softing.us/ra