Schneider Electric AB DH485 Protocol XBT N/R/RT

Similar documents
EIO /2011. Magelis HMISTO501. Zelio/Millenium Driver 07/2011 EIO

Ethernet Modbus X80 Gateway Device Type Manager

TeSys U LULC07 Profibus DP Communication Module

SCADAPack E Target 5 DF1 PLC Interface

Acti 9 Communication System

Packaging User Guide for Temperature Control M221 Project Template

Schneider Electric Floating License Manager

SoMachine Scan for Buttons Linked to ZBRN Modules Harmony ZBRN Library Guide

TSXCUSBMBP USB Modbus Plus Communications Adapter User Manual eng

TeSys UASILUFC5 - ASILUFC51 AS-i Communication Module

5521 Potentiometer Analog Input Module

5504 Thermocouple Analog Input Module

Unity Pro OSLoader User Manual

Schneider Electric License Manager

Smart Mode Measurements

LXM32. Explanation for detected error E 733F. Expert Support Machine Solution

LUFP9 Telemecanique User s Manual. Gateway DeviceNet / Modbus RTU

Magelis XBT-G Modbus (RTU) driver. eng

Altivar 61/71. Variable speed drives for synchronous and asynchronous motors. POWERLINK Communication Manual VW3A /2013

EcoStruxure Power Commission Installation Guide

NT31/631 Multi-Vendor Connection

SCADAPack E Idec PLC Interface Manual

Web Designer for Modicon M340, Premium and Quantum

How Can I. Integrate a Third-Party Modbus Device with PowerSCADA Expert? System Technical Note PowerSCADA Expert V1.0

/2008. Altivar 303. Variable speed drives for asynchronous motors. Modbus Communication Manual 06/2012 S1A

Twido Programmable Controllers Discrete I/O Modules

StruxureWare Power Monitoring 7.0

TeSys U Communication Variables

AIC+ Advanced Interface Converter. Catalog Number 1761-NET-AIC. User Manual. Allen-Bradley Spares

Change Report Colors and Logo

User Manual. Connection to Allen Bradley DF1. Part Number: Version: 2. Date: Valid for: TSwin.net 4.1x

Application Note: Using Modbus With the Conext CL Series. Important Safety Instructions

5401 and 5402 Digital I/O Modules

5403 and 5404 Digital Input Modules

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Allen-Bradley Motors

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Multi-Loader. User manual 06/ BBV48778

Altivar 12. Variable speed drives for asynchronous motors. Modbus Communication Manual 04/ BBV efesotomasyon.

CONFIGURATION GUIDE A-B REMOTE I/O LINK ADAPTOR FOR DL-KFR PC CARDS

SIMATIC. Communications processor CP 340 first commissioning steps. Getting Started 04/2005 A5E

EIO /2009. Advantys ETB. IP67 Ethernet Block I/O Modules for Modbus TCP/IP User Guide 7/2009 EIO

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

MultiTech Router Commissioning for Com X 200/210/510

Magelis XBTGC HMI Controller Programming Guide

Electrical network protection Sepam series 20 Sepam series 40 Quick start

PowerLogic ION7550 RTU option

General Specifications. P2-SCM Serial Communications

SCADAPack E ISaGRAF 3 I/O Connection Reference

5905 Ethernet Gateway Module

DeviceNet PCI Card Instructions Manual

174 CEV Modbus to Ethernet Bridge User Guide. 890USE19500 Version 1.0

Vijeo Connect User Guide For GateManager

www. ElectricalPartManuals. com SIMATIC HMI WinCC flexible 2005 Communication Part 1 Preface Working with connections 1

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

MT8050iE series. Installation Instruction (1) (2)

Point-to-point Link CP 441 Installation. and Parameter Assignment SIMATIC. S7-400 Point-to-point Link CP 441 Installation and Parameter Assignment

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SPiiPlusEC Network Manager Installation Guide November2014 Document Revision: 02

EIO /

Event Notification Module

Modicon Quantum /2013. Modicon Quantum. Quantum Safety PLC Safety Reference Manual 04/

Twido Programmable Controllers

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

P3-SCM. General Specifications

StruxureWare. Power Monitoring Expert 8.2 Hierarchy Manager Help Topics 7EN /2017

SoMachine. M238 High Speed Counting Functions High_Speed_Counter_M238.project Example Guide. 04/2012 Basic. Intermediate Expert

SCADAPack E ISaGRAF Quick Start Guide

Modicon TM3 (SoMachine Basic) Expansion Modules Configuration Programming Guide

Momentum 170ENT11001/170ENT11002 Ethernet Communications Adapter User Guide

Weight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

/2010. CANopen. Hardware Setup Manual 05/

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

RTS ISDN 2002 System. Operator Manual Software Description

Square D Clipsal Pascal Automation Controller

Field Upgrading Bulletin 1404 Power Monitor Version 4.2x base and 4.1x Ethernet Communications Firmware

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

SLC 500 BASIC and BASIC-T Modules

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

5502 Differential Analog Input Module

Installing the Panel. Installing the Panel

SCADAPack E Koyo DirectNET PLC Interface Manual

FactoryCast User Manual

Throughout this manual we use notes to make you aware of safety considerations:

Siemens Drives & PLCs

Unitronics Devices and RS485 Table Of Contents

Eaton Corporation Cutler-Hammer Business Unit 811 Green Crest Drive Columbus, OH PanelMate PLC Direct Communication Driver Manual

DTU3005-B Intelligent Data Transfer Device for Connection to PLCs and Modbus Networks Operator s Manual

SCADAPack 32 Controller

Operator Manual for Profibus

L5353 Profibus-DP Communications Interface

LXM23A CANopen Fieldbus protocol for servo drive Fieldbus manual V2.00,

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Installation Instructions

PROFIBUS MODULE (CB15) English Operating Instructions. Contents. Warning and Caution Notes

DL4000-DMX DF1 Full Duplex to Modbus (Master or Slave) Application Note

Technical Manual. HA Issue 4. Copyright Parker SSD Drives, Inc 2008

SPI Protocol Interface Module Cat. No SPI Concepts Manual

Transcription:

Schneider Electric AB DH485 Protocol XBT N/R/RT 33004016 06/2008 33004016.01

2 33004016 06/2008

Table of Contents Safety Information....................................5 About the Book.......................................7 Chapter 1 Compatibility.........................................9 Chapter 2 Operating Principle...................................11 General Information on Bus Communications........................... 12 Operating Principle............................................... 13 Chapter 3 Software Configuration...............................15 Vijeo-Designer Lite............................................... 16 Protocol - AB DH485 Dialog Box..................................... 18 Configuring Equipment Addresses................................... 20 Equipment Address Dialog Box...................................... 22 Chapter 4 Variable Types Supported.............................23 Chapter 5 Cables and Connectors...............................25 Cables......................................................... 26 SUB-D 25 Pin Connections......................................... 30 Chapter 6 Diagnostics.........................................33 XBT Detected Error Indication....................................... 33 Appendices.............................................. 37 Appendix A RS232/RS485 Recommendations.......................39 RS232 Recommendations......................................... 40 RS485 Recommendations......................................... 41 Glossary.............................................. 43 Index.............................................. 47 33004016 06/2008 3

4 33004016 06/2008

Safety Information Important Information NOTICE Read these instructions carefully, and look at the equipment to become familiar with the device before trying to install, operate, or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of this symbol to a Danger or Warning safety label indicates that an electrical hazard exists, which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a potentially hazardous situation, which, if not avoided, can result in death, serious injury, or equipment damage. CAUTION CAUTION indicates a potentially hazardous situation, which, if not avoided, can result in injury or equipment damage. 33004016 06/2008 5

Safety Information PLEASE NOTE Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. 2008 Schneider Electric. All Rights Reserved. 6 33004016 06/2008

About the Book At a Glance Document Scope Validity Note This document describes communication between automation systems and the XBT N/R/RT product range using the AB DH485 protocol. The data and illustrations found in this document are not binding. We reserve the right to modify our products in line with our policy of continuous product development. The information in this document is subject to change without notice and should not be construed as a commitment by Schneider Electric. Related Documents Title of Documentation Reference Number XBT N/R/RT Instruction sheet W916810140111 A08 XBT N/R/RT User Manual 33003962 Vijeo-Designer Lite Online help Product Related Warnings Schneider Electric assumes no responsibility for any errors that may appear in this document. If you have any suggestions for improvement or amendments or have found errors in this publication, please notify us. No part of this document may be reproduced in any form or by means, electronic or mechanical, including photocopying, without express written permission of Schneider Electric. All pertinent state, regional and local safety regulations must be observed when installing and using this product. For reasons of safety and to ensure compliance with documented system data, only the manufacturer should perform repairs to components. 33004016 06/2008 7

About the Book Since the XBT N/R/RT terminals are not designed to pilot safety critical processes, no specific instructions apply in this context. User Comments We welcome your comments about this document. You can reach us by e-mail at techpub@schneider-electric.com 8 33004016 06/2008

Compatibility 1 Compatibility Overview The DH485 protocol available for XBT terminals can be used to communicate with the following Allen Bradley process controllers: SLC-5/0X PLCs Micrologix 33004016 06/2008 9

Compatibility 10 33004016 06/2008

Operating Principle 2 At a Glance Overview This chapter describes the operating principle of XBT terminals in applications using the AB DH485 protocol. LOSS OF CONTROL WARNING The designer of any control scheme must consider the potential failure modes of control paths and, for certain critical functions, provide a means to achieve a safe state during and after a path failure. Examples of critical control functions are emergency stop and overtravel stop. Separate or redundant control paths must be provided for critical for critical control functions. System control paths may include communication links. Consideration must be given to the implications of unanticipated transmission delays or failures of the link.* Each implementation of a Magelis XBT N/R/RT must be individually and thoroughly tested for proper operation before being placed into service. Failure to follow these instructions can result in death, serious injury, or equipment damage. What's in this Chapter? *For additional information, refer to NEMA ICS 1.1 (latest edition), Safety Guidelines for the Application, Installation, and Maintenance of Solid State Control This chapter contains the following topics: Topic Page General Information on Bus Communications 12 Operating Principle 13 33004016 06/2008 11

Operating Principle General Information on Bus Communications Overview Roles of XBT Terminals The XBT terminals can be connected to PLCs using different protocols. This document describes the communication using the DH485 protocol with the XBT terminal acting as client. The terminals are usually connected to a communication equipment (PLC or other) via a field bus. The XBT and the PLCs work autonomously of each other. XBT terminals perform the following functions: monitoring function: XBT terminals visualize the processes that are active in the PLCs and indicate alarm states command function: XBT terminals send information to the PLC upon user request Roles of Buses Roles of Protocols A bus system provides the possibility to connect different devices via a unique cabling. The protocol defines the language that is spoken by all the equipment connected to the bus. 12 33004016 06/2008

Operating Principle Operating Principle Overview The DH485 protocol is an Allen Bradley communication protocol. The link between the XBT terminal and the Allen Bradley PLCs is one of the following types point-to-point multidrop SLC-500/Micrologix XBT WARNING UNINTENDED EQUIPMENT OPERATION The protocol must be installed and used by authorized and properly trained personnel. Failure to follow these instructions can result in death, serious injury, or equipment damage. 33004016 06/2008 13

Operating Principle 14 33004016 06/2008

Software Configuration 3 At a Glance Overview What's in this Chapter? This chapter contains the protocol parameters you must configure in the Vijeo- Designer Lite software for operating XBT terminals in DH485 applications. This chapter contains the following topics: Topic Page Vijeo-Designer Lite 16 Protocol - AB DH485 Dialog Box 18 Configuring Equipment Addresses 20 Equipment Address Dialog Box 22 33004016 06/2008 15

Software Configuration Vijeo-Designer Lite Overview Use the Vijeo-Designer Lite software to configure your XBT terminal for DH485 protocol applications. WARNING INCOMPATIBLE SOFTWARE Use only Schneider Electric manufactured or approved software to program hardware. Failure to follow these instructions can result in death, serious injury, or equipment damage. 16 33004016 06/2008

Software Configuration Opening the Protocol - AB DH485 Dialog Box To open the Protocol - AB DH485 dialog box in Vijeo-Designer Lite for setting the protocol parameters, proceed as follows: Step Action 1 Start Vijeo-Designer Lite. To create a new application, continue with step 2, if you have already created a DH 485 application, skip steps 2 and 3 and execute step 4. 2 From the application browser on the left-hand side of the Vijeo-Designer Lite window select the item Configuration Terminal & Protocol. Result: The following dialog box will be displayed on the right-hand side of the Vijeo-Designer Lite window. Terminal & Protocol Hardware Resolution Screen Color Back-light Color 10 Lines 33 Columns Black and White Green Peripherals Touch Screen Software Scrolling Alarm Yes No Yes Terminal Type XBT-RT500 Terminal Protocol DH485 Apply Cancel 3 From the Terminal Protocol list in the lower right corner select the item AB DH485 and click Apply. 4 Select from the application browser the item Protocol - DH485. Result: The dialog box Protocol - AB DH485 will be displayed on the right-hand side of the Vijeo- Designer Lite window where you can configure the protocol parameters for DH485 communication. 33004016 06/2008 17

Software Configuration Protocol - AB DH485 Dialog Box Purpose Use this dialog box to configure the protocol parameters for DH485 communication. Representation Protocol-AB DH485 Communication Transmission Speed Parity Bit Data Length 19200 Even 8 Stop Bits 1 Protocol Specific End Block Checking CRC Station Number 2 [0...31] Elements of the dialog box Element Communication Transmission Speed Parity Bit Data Length Stop Bits Protocol Specific Description Select the transmission speed (in bit/s) on your DH485 bus from the list. Make sure to configure the same transmission speed for all devices connected to the bus. You cannot edit this parameter because in DH485 communications the parity is always even. You cannot edit this parameter because in DH485 communications the length of user data is always 8 bits. You cannot edit this parameter because in DH485 communications always 1 stop bit is used. 18 33004016 06/2008

Software Configuration Element End Block Checking Station Number Description Select the error checking method (BBC or CRC) that should be executed. Select BCC (Block Check Character) for rapid, 8-bit format error checking. Select CRC (Cyclic Redundancy Checking) for less rapid but more reliable, 16-bit format error checking. Enter the unique address (between 0 and 31) of the XBT terminal in the network. 33004016 06/2008 19

Software Configuration Configuring Equipment Addresses Overview Use the Vijeo-Designer Lite software to configure addresses for the equipment your XBT terminal should communicate with. 20 33004016 06/2008

Software Configuration Opening the Equipment Address Dialog Box To open the Equipment Address dialog box in Vijeo-Designer Lite for configuring DH485 equipment addresses, proceed as follows: Step Action 1 Start Vijeo-Designer Lite. 2 From the application browser on the left-hand side of the Vijeo-Designer Lite window select the item Equipments. Result: The following dialog box will be displayed on the right-hand side of the Vijeo-Designer Lite window. Equipment Name Address MASTER [1] TSX57 [2] QUANTUM [3] Equipment Settings Add Delete Identification Symbol Variables Files Name MASTER Address (1)... Communication Double Word word order ASCII Display byte order High word first High byte first Common Settings Protocol Advanced Settings 3 In the Equipments dialog box select a slave device from the list. 4 In the Equipment Settings Identification box below click the... button right to the Address text box. Result: The Equipment Address dialog box will be displayed where you can configure an address for the selected equipment. 33004016 06/2008 21

Software Configuration Equipment Address Dialog Box Purpose Representation Use this dialog box to configure the address of equipments connected to the network. DH485 equipment address Equipment Address Address CPU Number: 1 Elements of the dialog OK Cancel Help Element CPU Number OK button Cancel button Help button Description Enter the address (between 0 and 31) for the selected equipment. Click the OK button to assign the entered address to the selected equipment. Click the Cancel button to discard the changes and to close the dialog box. Click the Help button to open the Vijeo-Designer Lite online help. 22 33004016 06/2008

Variable Types Supported 4 Variable Types Supported Table of Variable Types Supported by the XBT The following table lists all DH485 variables XBT terminals can access. Variable Type Supported DH485 Syntax Identifiers Bit Nf:i/j f:(0...255) i: (0...255) j: (0...15) Word, String, Double Word Nf:i f:(0...255) i: (0...255) Floating Point Ff:i f:(0...255) i: (0...255) File Number f Index i Index j Indicates the number of the file in the process controller that the operator wishes to access. Indicates the item number in the selected field (word number). It will only be possible to access this field if the selected data type is Nf:i/j. It indicates the position of the bit in the word (selected by i field). 33004016 06/2008 23

Variable Types Supported 24 33004016 06/2008

Cables and Connectors 5 At a Glance Overview What's in this Chapter? This chapter specifies the cables and connectors required for XBT terminals in DH 485 applications. This chapter contains the following topics: Topic Page Cables 26 SUB-D 25 Pin Connections 30 33004016 06/2008 25

Cables and Connectors Cables Technical Data The following table lists the cables required to connect XBT terminals to the SLC /Micrologix PLCs in multidrop or point-to-point applications. Connected Device Terminal Physical Link Cable Reference Length SLC/Micrologix, pointto-point SLC/Micrologix, multidrop (via 1761-NET-AIC provided by Allen Bradley) * XBT N401/N410 XBT R410/R411 RS232 XBT Z9732 2.5 m (8.2 ft.) (SUB-D25 <--> Micrologix 1000) XBT RT500/RT511 RS485 XBT Z9734** 2.5 m (8.2 ft.) (RJ45 <--> Micrologix 1000) XBT N401/N410 XBT R410/R411 RS232 XBT Z9730 2.5 m (8.2 ft.) (SUB-D25 <--> SUB-D9) XBT RT500/RT511 XBT Z9741* 2.5 m (8.2 ft.) (SUB-D25 <--> SUB-D9) XBTRT511: you must add a XBT ZG939 cable adapter (SUB-D25 <-> RJ45) XBTRT500: you must add a XBT ZG939 cable adapter (SUB-D25 <-> RJ45) and a XBT ZRTPW for power supply. ** XBTRT500: you must add a XBT ZG939 cable adapter for power supply. 26 33004016 06/2008

Cables and Connectors Multidrop Connection Diagram CAUTION POWERED CONNECTORS Connect the serial link and printer link to the XBT with the power OFF. Failure to follow these instructions can result in injury or equipment damage. (*) Provided by Allen Bradley DH485 1747 AIC* 1747 AIC* DH485 DH485 1761-NET-AIC* SLC-500/ Micrologix SLC-500/ Micrologix XBT-Z 9730 XBT 33004016 06/2008 27

Cables and Connectors How to Connect a PC in Point-to- Point Mode to the DH485 Network CAUTION POWERED CONNECTORS Connect the serial link and printer link to the XBT with the power OFF. Failure to follow these instructions can result in injury or equipment damage. SLC-5/0X/Micrologix XBT-Z9732 CN1 DH485 0V TSX-SCA72 TSX-CTC01 5 B 4 A SCA 72 5-way terminal block 28 33004016 06/2008

Cables and Connectors How to Connect a PC in Multidrop Mode to a DH485 Network CAUTION POWERED CONNECTORS Connect the serial link and printer link to the XBT with the power OFF. Failure to follow these instructions can result in injury or equipment damage. (*) Provided by Allen Bradley DH485 1761-NET-AIC* 1747 AIC* 1747-CP3* 1761-CBL-AP00* DH485 SLC-500/ Micrologix SLC-500/Micrologix 33004016 06/2008 29

Cables and Connectors SUB-D 25 Pin Connections Overview The following XBT terminals provide a SUB-D25 connector on their rear panels: XBT N401 XBT N410 XBT R410 XBT R411 The pin assignment of the SUB-D25 connector is shown in the following figure. 1 2 TXD 3 RXD 4 0 5 1 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 7 8 9 10 11 12 13 14 15 16 17 18 0V iso COM REG CONF B0 B1 B2 B3 19 B4 20 21 22 0V iso 23 24 PAR 25 30 33004016 06/2008

Cables and Connectors Wiring The illustration below shows the wiring: XBT Terminal SLC/ Micrologix PLC PG 1 0V SG 22 TXD+ A 4 2 /Data A Rt Rt TXD- B 5 1 Data RXD+ RXD- +5V Rp Rp 0V A B 6 18 RJ45 connector 8 12 Rt line impedance matching resistor Note: RP resistors are integrated into the XBT and feature: 4.7 kω for XBT N 470 Ω for XBT R 600 Ω for XBT RT 33004016 06/2008 31

Cables and Connectors 32 33004016 06/2008

Diagnostics 6 XBT Detected Error Indication Overview Question Marks and Crosses XBT terminals indicate detected errors in different ways by displaying question marks?????? on alphanumerical fields by displaying crosses for graphic objects by displaying hash characters in alphanumerical fields by blinking alphanumerical fields by issuing system error messages The following paragraphs list these three detected errors and their possible reasons. When question marks?????? and crosses XXXXXX are displayed on the display of your XBT terminal, a transmission error has occurred. To correct this, check the following: If... Then... question marks are displayed verify that all cables are correctly connected. question marks are displayed verify that the communication parameters set in the Protocol - AB DH485 dialog box are identical for all equipment connected to the bus i.e. same transmission speed, same use of parity. question marks are displayed the XBT terminal may have received no response from the PLC. Hash Characters Hash characters displayed in alphanumerical fields on your XBT terminal indicate that the value to be displayed is too long for this alphanumerical field and cannot completely be displayed. The value 100 can, for example, not be displayed in a 2- digit alphanumerical field. To correct this, enter a shorter value or adapt the size of the alphanumerical field so that it can display any of the possible values of the PLC variable. 33004016 06/2008 33

Diagnostics Blinking Alphanumerical Fields System Error Messages Blinking alphanumerical fields on your XBT terminal indicate that the value of this field has exceeded or fallen below a user-defined threshold. A variety of system error messages is by default configured for the terminals. All these standard system messages are assigned a panel number 200+x. A distinction is made between system error messages indicating communication interruptions and status messages provoked by inputs at the terminal. These 2 message types differ by the numbers they are assigned and by the way they are displayed at the terminal as shown in the list below: System Error Message Caused by: Communication Interruptions System Error Message Numbers Display Mode 201 204 To indicate that a communication interruption has occurred, the message is displayed in a popup dialog box every 10 seconds. Input at Terminal 241 258 The status message is displayed as a response to user input at the terminal. Messages Caused by Communication Interruptions Messages 201 to 204 are issued by the terminal to indicate that a communication interruption has occurred. They are displayed in a popup dialog every 10 seconds. If... Then... message 201: DIALOG TABLE AUTHORIZATION INCORRECT is displayed message 202: DIALOG TABLE WRITING IMPOSSIBLE is displayed message 203: DIALOG TABLE READING IMPOSSIBLE is displayed the authorization word in the dialog table does not have the expected value. (Refer to the Vijeo- Designer Lite online help for information on how this word is working.) To correct this, verify that: you are connected to the right PLC the memory of your PLC is not corrupted the correct value is saved on the PLC the write cycle to the dialog table of the PLC could not be ended. This condition may have the following causes: too much load on the communication bus EMC disturbances on the communication bus the read cycle from the dialog table of the PLC could not be ended. This condition may have the following causes: too much load on the communication bus EMC disturbances on the communication bus 34 33004016 06/2008

Diagnostics Messages Caused by Input at the Terminal Messages 242 to 254 are issued by the XBT as a response to user input at the terminal. These messages are displayed directly after the operator has sent an incorrect command to the terminal and will persist until the user has corrected the entered command or value. Messages 255 to 258 are status messages displayed after the user has initiated an operation at the terminal to indicate that it has (or has not) been accepted and is in progress. If... Then... message 241: IMPOSSIBLE TO READ VARIABLE is displayed message 242: IMPOSSIBLE TO WRITE VARIABLE is displayed messages 243 to 249 are displayed message 250: LANGUAGE IMPOSED BY PLC is displayed messages 251 or 252 are displayed message 253: PASSWORD IMPOSED BY PLC is displayed message 254: PROTECTED ACCESS PAGE is displayed messages 255 to 258 are displayed the terminal has attempted to read a variable and could not retrieve its value. This condition may have the following causes: too much load on the communication bus EMC disturbances on the communication bus the terminal has attempted to write in a memory area of the equipment and has received a negative acknowledgement or no acknowledgement at all. This condition may have the following causes: too much load on the communication bus EMC disturbances on the communication bus correct the value or command you have entered as indicated by the message. the PLC forces the terminal to use a language. This language cannot be changed by the operator. For more information see the Vijeo-Designer Lite online help, functions of the dialog table. correct the value or command you have entered as indicated by the message. you cannot change the password at the terminal because it is forced by the PLC. For more information see the Vijeo-Designer Lite online help, functions of the dialog table. you are trying to access a page that is password protected but you do not have the required authorization level. the commands you entered at the terminal are executed or not executed, as indicated in these status messages. 33004016 06/2008 35

Diagnostics 36 33004016 06/2008

Appendices At a Glance Overview What's in this Appendix? This chapter contains some RS232/RS485 recommendations. The appendix contains the following chapters: Chapter Chapter Name Page A RS232/RS485 Recommendations 39 33004016 06/2008 37

Appendices 38 33004016 06/2008

RS232/RS485 Recommendations A At a Glance Overview What's in this Chapter? This chapter decribes the RS232/RS485 recommendations. This chapter contains the following topics: Topic Page RS232 Recommendations 40 RS485 Recommendations 41 33004016 06/2008 39

RS232/RS485 Recommendations RS232 Recommendations Diagrams for RS232C Link RS232C link Distance 100 m (328.1 ft.) RS232 C 15 m (49.2 ft.) 100 1 K 10 K 19,2 K (bit/s) Speed Maximum length for the link is 15 m (49.2 ft.). Wiring = 3 shielded wires with a minimum cross-section of 0.6 mm 2 (AWG22) Note: The maximum length including the RS232 link is 15 m (49.21 ft.), provided that the equipment connected to the XBT terminal is not subject to more stringent restrictions (refer to connected devices instruction sheet) and for XBT RT500 provided that the length of the cable is below 10 m (32.8 ft.) (because power is also supplied by this cable). 40 33004016 06/2008

RS232/RS485 Recommendations RS485 Recommendations Diagrams for RS485 Link RS485 link Distance 1,200m (3,937 ft.) Speed 1 K 100 K 10 M (bit/s) Maximum length for the link is 1,200 m (3,937 ft.). Wiring = 2 shielded twisted wires with a minimum cross-section of 0.6 mm 2 (AWG22) and one 0 V wire Note: The maximum length including the RS485 link is 1,200 m (3,937 ft.), provided that the equipment connected to the XBT terminal is not subject to more stringent restrictions (refer to connected devices instruction sheet) and for XBT RT500 provided that the length of the cable is below 10 m (32.8 ft.) (because power is also supplied by this cable). 33004016 06/2008 41

RS232/RS485 Recommendations 42 33004016 06/2008

Glossary A AWG American wire gauge (wire diameter) F FCS frame check sequence M Magelis Generic commercial name of the range of Schneider HMI terminals. P PLC programmable logic controller 33004016 06/2008 43

Glossary R RS232 recommended standard for connecting serial devices = EIA/TIA 232 RS485 recommended standard for connecting serial devices = EIA/TIA 485 V Vijeo-Designer Lite Configuration software for the low end Magelis range. It replaces the XBT-L1000 software. X XBT Any HMI terminal (when it is not necessary to make a distinction). 44 33004016 06/2008