How to install or remove the ISaGRAF development platform properly

Similar documents
Getting Started : W-8037/8337/8737. The Web PAC

Getting Started: I / / 8437/8837/8417/8817

RTE for WIN32. Installation Manual (Rev.7.0) Midas lab

Getting Started. ContrexHost 3. Suite of Serial Communications Applications for Contrex Motion Controls

Quick Guide for BlueSoleil Version 6

USB driver and Software Installation. UPS Monitoring and Management Software

IMC Intelligent Analysis Report v7.1 (E0301P02) Copyright (c) 2015 Hewlett-Packard Development Company, L.P. and its licensors.

USER MANUAL for USB Data Link

NiceLabel Suite. Installation guide. Euro Plus d.o.o. English Edition. Version

INSTALLING THE PS3 XBOX READY SOFTWARE:

Quick Installation Guide TU-S9

Installation Procedure of IRsolution

OKIFAX 5650 MFP Option Kit. Overview. Setup Guide

MW-260 Mobile Printer

IDIS Solution Suite. Streaming Service. Software Manual. Powered by

Copyright Autodesk, Inc.

Firmware, Database, & PC Application Update Installation Instructions

Windows NT Server Printer Driver Upgrade Instructions

ZwCAD Licensing Guide. Contents

BLUETOOTH 2.0 MINI USB ADAPTER. Quick Start Guide TABEL OF CONTENTS

Installing and Setting Up the Snap-on EPC. Rev.1.6 (12 Apr 2012) PN EN

Operating Instructions

Trademark and Copyrights

USB Adapter Raytown Road Kansas City, MO U.S.A. Tel.: Fax:

Que! USB Floppy Disk Drive Installation Guide

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

ION Demo Kit. Quick Start Guide PERFORMANCE MOTION DEVICES

KD Max V5 Upgrade & Installation Guidance For upgrade users KD Max V5 Upgrade & Installation Guidance

Introduction. 1 available USB type A (downstream) port. Windows 98, Windows ME, Windows 2000, Windows XP,

DRAWings 8 and Wings modular 8 Embroidery Software INSTALLATION GUIDE

STOP! Read these instructions before connecting the PR3 to your Computer

Data Manager Installation and Update Instructions

Super USB. User Manual. 2007, March

Installing ACS Mapping Extension for ArcGIS 9.3 and 10

EasyMP Multi PC Projection Operation Guide

MW-120 Mobile Printer

Installation Instructions

PropertyBoss Upgrade

Spectrometer Visible Light Spectrometer V4.4

Fiery PRO 80 /S450 65C-KM Color Server. Welcome

PAL Installation Instructions

REVISIONS * The manual number is given on the bottom left of the back cover.

DiMAGE Scan Elite 5400 II Ver.1.0.2

Firmware, Database, & PC Application Update Installation Instructions

Technical Bulletin DS2

Install Manual. P2 Software ENGLISH M0509AT5091 -FJ VQT2G26-4

Plug the USB interface of KAMKBMXBRNA gaming keyboard onto the free USB port of the computer. The

Installing FileMaker Pro 11 in Windows

Xerox 700 Digital Color Press with Integrated Fiery Color Server. Welcome

QUICK START. DevCom2000 User Manual

For ClassPad 300 PLUS. ClassPad Manager. Version 2.2 (PROGRAM-LINK TM ) User s Guide.

January 2015 SPIDER 2j Full Install & Update

Goodwill Accounting 6

Professional. Central Management Software. Cam Viewer Pro. Quick Installation Guide

Secure Single Sign On with FingerTec OFIS

F-Secure Client Security. Quick Installation Guide

QL-500 QL-560 QL-570 QL-650TD QL-1050

REVISIONS * The manual number is given on the bottom left of the back cover.

Table of Contents. D-Link SharePort Plus... 4 Introduction...4 System Requirements...4 Features...5. Installation... 6

UNGASS DATA ENTRY SOFTWARE: GLOBAL REPORTING 2008 SETUP NOTES

Hi-Phone DeskTop USB H/W User Manual

Fiery EX4112/4127. Welcome

AN-619 APPLICATION NOTE

CTECS Connect 2.2 Release Notes December 10, 2009

Dot Matrix Indicator Programming

HyperBlade Bluetooth Serial Port Setup Guide For use with Scimitar Software and USB Bluetooth adapter Hyperdyne Labs 2006

FAQ - How do I get started with QDMS?

500 Series Installation Guide

Magic Card Professional

WA1976 WebSphere Application Server 7.0 Administration Fundamentals. Classroom Setup Guide. Web Age Solutions Inc.

1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically.

How to install the software of ZNS8022

Before you attempt to upgrade from the Live200 system to LiveLAN 3.1, make sure that you have the following:

AN-77XX-XP 2K MCS77XX. Windows-2k & Windows-xp

Procedures to Install Eye Com's ImageMouse and ImageMouse Plus using Windows XP platform

USB to Serial Converter User s Guide

Setting up the PC ready for BESA 11

Operating Instructions

Sharp Advanced Presentation Software OPERATION MANUAL. Professional Edition Version 1.5. Transferring Images. Troubleshooting

CONTENTS. SysReturn_Manaual Updata 06/4/24. Chapter1 Introducing SysReturn Introduction to SysReturn Features and Functions...

INTRODUCTION...1. I. Install the driver of USB TO IRDA Adapter... 2 Under Windows 98se/Me...2 Under Windows 2000/XP...9

ECLIPSE LV Series Support Tools

QUICKBOOKS PRO 2009 INSTALLING QUICKBOOKS PRO AND STUDENT DATA FILES

Pre-installation Installing a microsd card Installing the USB 598 USB adapter and Watcher software

Software Update Notification

Channel 4. User Manual. Version 2.0

GP-N100 Utility Software Manual

Quick User Guide. 1. Installing Readiris TM. 2. Starting Readiris TM

2009 Electronics for Imaging, Inc. The information in this publication is covered under Legal Notices for this product.

PCLinq2 (PL-2501) Hi-Speed USB Bridge Cable End-User s Manual Guide

Getting Started : VP-25W7, VP-23W7

SAS Installation Instructions Windows 2003, XP, 2000, NT. Workstation Installation Guidelines

Cover. MATWorX Installation Guide NWA ISSUE 2.1

Important Notes for WinConnect Server VS Software Installation:

Installing HostExplorer 10 For the PC Author: Byron Watanabe

DZ-MV350/380 Software Tutorials

Installing Lotus Notes on Your Computer Lotus Notes release (Standard and Basic versions)

RadioXtreme USB Radio Model: FMU-100 Quick Installation Guide (Version 1.0)

FOODSERVICE. Owner s Manual. Read And Save These Instructions CUSTOM BLENDING. Software. for all. Programmable Vita-Mix Machines

1 Minimum system requirements

Transcription:

How to install or remove the ISaGRAF development platform properly By grady_dun@icpdas.com For the ICP DAS ISaGRAF PACs and the ISaGRAF Workbench software to operate properly, it is imperative that each is setup correctly. This paper covers the details of how to setup the controller system and the ISaGRAF Workbench software in a minimum of time. Hardware Requirements A Personal Computer With At Least A Pentium, 133 MHz Or Faster Processor 32 Mbytes Memory (Preferably 64 Mbytes RAM) A Hard Drive With At Least 128 Mbytes Of Storage Space (Preferably Larger) At Least One RS-232 Serial Port Software Requirements One of the following computer operating systems must be installed on the target computer before you can install the ISaGRAF Workbench software program. Windows 95 Windows 98 Windows NT Version 3.51 or Windows NT Version 4.0 Windows 2000 Or Windows XP Windows Vista 32-bit Windows 7 The main steps as follows I. Set up the ISaGRAF develop platform 1. Install the ISaGRAF Workbench program 2. Install the ICP DAS Utilities For ISaGRAF program II. Remove the ISaGRAF develop platform I. Set up the ISaGRAF develop platform 1. Install the ISaGRAF Workbench program Insert the ISaGRAF Workbench CD into your CD-ROM drive. Normally the auto-start program will activate the "install.bat" file automatically. If your computer does not have the auto-start feature active, use the Windows Explorer and go to the CD-ROM drive where the Workbench CD is installed, then double-click on the "install.bat" file listed on the ISaGRAF CD. If the "install.bat" file is not found on your ISaGRAF CD, then double-click on the "ISaGRAF.exe" file to start the installation process. Once you have started the "install.bat" file, a dialog box will appear as shown as the Figure 1. Select the language version of the ISaGRAF software program you would like to use. The English version is used on all subjects and examples throughout this manual. Figure1 : ISaGRAF FAQ-121 Copyright 2010 ICP DAS Co., Ltd. All Rights Reserved. 1

Once you have selected to install the ISaGRAF Workbench program and selected the desired language, just press the "Install" button, and follow the step-by-step directions of each dialog box as they appear to complete the installation process. The first dialog box to appear allows the user to define what drive and subdirectory the ISaGRAF program will install into. Type the path that you want install ISaGRAF workbench into. The next dialog box asks the user how much of the ISaGRAF program to you wish to install. By default, it is best to allow all of the ISaGRAF programs to install. Once you have selected which programs and applications are to be installed, the installation process begins, and an installation progress dialog box will appear showing the installation progress. Once the ISaGRAF Workbench software installation process has been completed, a Windows Explorer window will appear showing the installed programs. ISaGRAF FAQ-121 Copyright 2010 ICP DAS Co., Ltd. All Rights Reserved. 2

If your ISaGRAF Key-Pro is USB type, please follow below steps to install the proper USB driver. 1. To make your PC recognize the ISaGRAF USB protection-key, please un-plug the USB protection-key from your USB port first, then run \Sentinel\SSD5411-32bit.exe in the ISaGRAF 3.55 CD-ROM after you have installed the ISaGRAF. Then please reset your PC. 2.To run ISaGRAF Ver. 3.5x, please always plug the USB protection-key in the PC s USB port. NOTE: You must install the hardware protection device (dongle) provided with the ISaGRAF software on your computers parallel port to for the ISaGRAF program to achieve fully authorized functionality.(except the ISaGRAF-32, it doesn't require the dongle) While using ISaGRAF and the dongle is plugged well, if the Help About says Maximum number of IO variables: 32, it means ISaGRAF workbench cannot find the dongle well. Please reset your PC and then check the Help About again. If it still displays Maximum number of IO variables: 32, the dongle driver may not be installed well. Please execute the ISaGRAF CD_ROM \Sentinel5382\setup.exe for ISaGRAF-80 or \Sentinel\setup.exe for other ISaGRAF version (except ISaGRAF-32) or follow the former section if your protection-key is USB type. and then reset the PC again. For Windows Vista (32-bit): DISABLE the User Account Control of the Windows Vista (32-bit) before installing the ISaGRAF Workbench. How to disable the User Account Control NOTE: the following operation is Only for the administrator can do that 1. From the Start menu, choose Control Panel, then User Accounts, then User Accounts, then click Turn User Account Control on or off. 4. Click Continue on the pop-up UAC dialog. ISaGRAF FAQ-121 Copyright 2010 ICP DAS Co., Ltd. All Rights Reserved. 3

5. Don't check the Use User Account Control(UAC) to help you protect your computer option, then click the OK button 6. Restart your computer once. 7. Follow steps listed in the page 1 to install the ISaGRAF workbench. For Windows 7 Professional, Enterprise, or Ultimate: For Windows 7 (32-bit): DISABLE the User Account Control before installing the ISaGRAF Workbench. How to disable the User Account Control NOTE: the following operation Only the administrator can do that 1. From the Start menu, choose Control Panel, then User Accounts, then User Accounts, then click Change User Account Control setting. 4. Click Continue on the pop-up UAC dialog. ISaGRAF FAQ-121 Copyright 2010 ICP DAS Co., Ltd. All Rights Reserved. 4

5. Slide the slider bar to the lowest value (towards Never Notify), with description showing Never notify me. 6. Restart your computer once. 7. Follow steps listed in the page 1 to install the ISaGRAF Workbench. For Windows 7 (64-bit): ISaGRAF Ver. 3 can only run in the XP mode inside the Windows 7(64-bit). Please do the following steps to install the XP mode and Virtual PC. Install Virtual PC and XP mode 1. You could check that your PC hardware works with Windows XP Mode by downloading and running Microsoft Hardware-Assisted Virtualization Detection Tool 2. Download Windows Virtual PC and Windows XP Mode installers from the Windows Virtual PC Web site (http://go.microsoft.com/fwlink/?linkid=160479). 3. Download the document, Installation instructions and Release Notes for Windows Virtual PC and Windows XP Mode, from Windows Download Center and follow the steps listed in the document to install Virtual PC and XP mode. 4. Restart your computer once. To Install the ISaGRAF Ver. 3 5. In the virtual machine, please follow the steps listed in the page 1 to install the ISaGRAF workbench. ISaGRAF FAQ-121 Copyright 2010 ICP DAS Co., Ltd. All Rights Reserved. 5

Important Notice For Windows NT Users If your computer is using the Windows NT operating system, you will need to add one line to the "isa.ini" file in the ISaGRAF Workbench "EXE" subdirectory. The default path of installing ISaGRAF program is C:\isawin\exe\isa.ini. You can use any ASCII based text editor (such as Notepad or UltraEdit32) to open the "isa.ini" file. Locate the [WS001] header in the "isa.ini" initialization file (it should be at the top of the file). Anywhere within the [WS001] header portion of the "isa.ini" initialization file, add the entry shown below within the [WS001] header: [WS001] NT=1 Isa=C:\ISAWIN The [WS001] header should now look like the above example. The NT=1 entry addition is absolutely required for the RS-232 communications to operate properly in the Windows NT operating environment. When closing the ISaGRAF window on windows 2000, it sometimes holds (No response). You may create a short cut for the ISaGRAF project manager. And then check on "run in separate memory space" option in the shortcut property. ISaGRAF FAQ-121 Copyright 2010 ICP DAS Co., Ltd. All Rights Reserved. 6

2. Install the ICP DAS Utilities For ISaGRAF program The ICP DAS Utilities For ISaGRAF consists of 4 major items. I/O library definition Modem_Link utility Auto-scan I/O utility ICPDAS Udloader Please insert the CD-ROM into your CD-ROM drive. Then run setup.exe in the folder of CD-ROM: \napdos\isagraf\. Follow the Setup Wizard's guide to install it. Note: If setup.exe is not in your CD-ROM, please download ICP DAS Utilities For ISaGRAF from http://ftp.icpdas.com/pub/cd/wincon_isagraf/napdos/isagraf/io_lib.zip If you change the path of installing the ISaGRAF Workbench, redirect the path of installing the ICP DAS Utilities For ISaGRAF to the path that contains the ISaGRAF Workbench. II. Remove the ISaGRAF development platform The main steps as follows 1. Remove the ICP DAS Utilities For ISaGRAF 2. Delete the folder that contains ISaGRAF Workbench 3. Remove the ICP DAS Utilities For ISaGRAF From the Start menu, select Control Panel ISaGRAF FAQ-121 Copyright 2010 ICP DAS Co., Ltd. All Rights Reserved. 7

Click the Add or Remove Program icon Select the program ISaGRAF Utilities to remove and click Remove Follow the Remove Wizard's guide to uninstall it. ISaGRAF FAQ-121 Copyright 2010 ICP DAS Co., Ltd. All Rights Reserved. 8

4. Delete the folder that contains the ISaGRAF Workbench Important note: Please backup your project files if you want to keep them before remove the ISaGRAF Workbench. Click My computer on the desktop and click Local Disk (C:) Delete the folder ISAWIN (the default path of installing ISaGRAF Workbench is C:\ISAWIN\) ISaGRAF FAQ-121 Copyright 2010 ICP DAS Co., Ltd. All Rights Reserved. 9