Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Similar documents
Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Rack cooling solutions for high density racks management, from 10 to 75 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

New Design Strategies for Energy Saving. Intelligent free-cooling

Aquaflair. BREC/F and BCEC/F kw

Ecoflair Air Economizers

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

2018 Product overview

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

IT Air Conditioning Units

Airedale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

MOLLIER DIAGRAM CAN BE IMPROVED!

Precision Cooling Mission Critical Air Handling Units

DEDICATED HEAT RECOVERY UNIT (DHRC)

Chiller Replacement and System Strategy. Colin Berry Account Manager

GP SERIES Packaged Chillers

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

Air-Cooled Series R Chiller

CHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

HIGH EFFICIENCY Central Chiller

ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS

Efficiency of Data Center cooling

Application Manual. Shark. Software for the simulation of refrigeration equipment and air conditioners

Liebert HPC Freecooling Chiller

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

DUCTED SPLIT SYSTEMS With Scroll compressors

CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT

Liquid Cooling Package LCP Cooling Systems

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw

4-step Chiller and Heat Pump Controller

Blue e+ chillers with the principle

Reliability and extended operation

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

CTC Low Temperature Process Chillers

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

Liquid Cooling Package LCP Cooling Systems

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

MSYS 4480 AC Systems Winter 2015

Liebert DCW CATALOGUE

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

HOURLY ANALYSIS PROGRAM v5.00 and v5.01

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Introducing the Heat Wheel to the Data Center

Industry leading low energy evaporative fresh air cooling.

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

84 kw, Tier 3, Direct Expansion, 937 ft 2

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

Data Center Energy Savings By the numbers

Large Tonnage Chillers. Kingsley Hu Technical Support Engineer

Close-coupled cooling

Liebert. DSE Thermal Management System Free Cooling Economization Without Using Water

U-Match Series DC Inverter Service Manual PRODUCT

IT COOLING CHILLERS. AIR COOLED CHILLERS WITH FREE-COOLING TECHNOLOGY, FROM 302 TO 1649 kw

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Total Modular Data Centre Solutions

User Guide. FreeCool : Free Cooling unit V1.1 ENGY-SVU001A-GB

Ecotel Free Cool 5-15kW

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Data Center Optimized Controls

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

Communication Register Map - Uniflair Cooling

AIR COOLED CONDENSERS

30XAV & 30XWV. Air and water-sourced, variable-speed screw units. AquaForce with Greenspeed intelligence, Because you should not have to choose.

FACT SHEET: IBM NEW ZEALAND DATA CENTRE

Liebert. DCL up to 35 kw. Modular Rack Cooling

Liebert. DCL up to 35 kw. Modular Rack Cooling

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Rittal Cooling Solutions A. Tropp

200 kw, Tier 3, Chilled Water, 5250 ft 2

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

Transcription:

Aquaflair Uniflair TRAC, TRAF and TRAH Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors 120-350kW

Uniflair TRA ranges 115-350kW Air-cooled Chillers Cooling, Free cooling and Heat Pumps 9 sizes, many configurable options Applications Data centers Industrial applications High performance comfort applications 2

Product range The TRAC/F/H range will replace the current chiller range, extending the concept and the technologies which are applied on mid chillers (50-100kW) range and it will cover the gap (260-350kW) in the current product portfolio Current scenario No products available here 6 40 100 260 350 1150 kw Next scenario 6 40 100 350 1150 kw 3

Main features R410A Refrigerant Scroll compressors Single / double circuit Single passage plate heat exchanger Basic / UltraQuiet version Electronic Expansion Valve Free-cooling: Standard, Intelligent and Glycol-free Acoustic-composite fans with EC or AC motor Onboard Variable Speed Driven (VSD) pumps group Single, double or separate power supply 4

How it s made 5

Frame Two different layout are available according to the cooling capacity to guarantee Accessibility Lateral access on small sizes Rear access on large frame Easy maintenance and component replacement 115-235kW Transportation Two small frames can be combined to be delivered in a standard 20ft container Large frame is suitable for container transportation 260-350kW 6

Main components / 115-235kW Electrical panel fans free-cooling coils Water connections User terminal Main pump/s Electrical connections Condensing coils Compressor housing Water tank 7

Main components / 260-350kW Electrical panel fans free-cooling coils Pump inverter User terminal Water connections Condensing coils Electrical connections Compressor housing Main pump/s Water tank 8

Refrigerant / Compressors R410A R134a 400-500 kw 9

R410A refrigerant Excellent performance High intrinsic efficiency Hardly any glide Constant performance: Constant mix Optimized components Limited direct (GWP) and indirect (TEWI) environmental impact 10

Load reduction Cooling section All models of the TRA range are available with tandem technology Efficiencies at part load conditions are therefore optimized 2/1 4/2 115 130 350 kw 11

Acoustic composite fans Axial fans in a composite material Aluminium core for a better heat dissipation Plastic blades to improve air flow Less weight grants efficiency and reliability The optional electronically commutated motor improves: Energy efficiency Noise impact during regulation Max external temperature 12

Microprocessor control board Operation: outlet chilled water temperature regulation by means of an exclusive PID algorithm and main data acquisition and limits management Complete set for integrated cards clock card to register any alarms or set operation strategies LAN card for connecting more than one unit to the local area network USB connection for data downloading RS485 serial card to BMS connections with several protocols Field integration ability to interface with two separate BMSs set-point variation based on external temperature or signal external motorized isolating valve management 13

Free-cooling TRAF units are fitted with integrated economizer. This solution, thanks to the particular unit features, maximizes efficiency According to the site conditions the unit can be configured with specific free-cooling systems Exclusive Aquaflair free-cooling Intelligent free-cooling Glycol-free 14

Aquaflair Free-cooling Winter Mid-season Summer External air External Air Compressors (partially) Compressors Minimized absorbed energy Low absorbed energy Max absorbed energy 15

Intelligent free-cooling Mission critical systems require uncompromised reliability, along with energy saving strategies Exploiting the free-cooling sections of the stand-by units it is possible to increase the free-cooling capacity and to amplify the energy saving 16

Glycol free How to perform free-cooling without glycoled water? Glycoled section Pure water section Integrated system to separate main water system to free-cooling circuit Glycol presence remain on free-cooling circuit only Mid-season mode efficiency reduction Additional cost for the configuration Propylene glycol is anyway ecological 17

Mission critical environments Efficiency Availability Configurability & flexibility 18

Energy Efficiency 19

Leading Technology for efficiency R410A refrigerant Tandem for efficiency on all the units Integrated Free-cooling systems for TRAF units EC fans as an option optional Electronic Expansion Valve 20

Electronic Expansion Valve Optional Electronic expansion valve managed by the Schneider-Electric control board Reliability operating limits respected Indirect monitoring of the refrigerant load Efficiency: Superheating management Improved deltat at evaporator Precision: Close deltat at evaporator 21

Electronic Commutated Technology fans Axial fans produced in composite material with EC motor Higher Airflow than AC fans High efficiency on fans and on the unit Higher external temperature operation High reliability Starting current lower than the nominal 3.2 3.0 2.8 2.6 2.4 2.2 EER +7% TRAC range (AC fans) TRAC range (EC fans) Low noise level at part load speed Nom. Cond. 7/12 C, 35 C 0% glycol, average values 22

Energy recovery The best solution to improve energy efficiency is to optimize available resources TRA* units offer specific options for energy recovery Integrated free-cooling recover external air energy Partial heat recovery options optimizes compressors absorbed power Total heat recovery options optimizes cooling load and compressors absorbed power 23

Energy efficiency data EER ESEER 3.2 3.0 2.8 +8% +15% 4.4 4.2 4.0 +29% +35% 2.6 3.8 2.4 3.6 2.2 3.4 ARAC range (AC fans only) TRAC range (AC/EC fans) Nom. Cond. 7/12 C, 35 C 0% glycol, average values ARAC range (AC fans only) TRAC range (AC/EC fans) European Energy Efficiency Ratio 24

Energy efficiency data free-cooling Mixed free-cooling mode improvement thanks to dedicated valves on condensing coils Inlet water temperature maximization: up to 25 C Integrated Energy monitoring system linked to the control board (optional) 50.0 10.0 6.0 5.0 4.0 3.0 EER -5 C 5 C 15 C 25 C 35 C TRAF2642A (EC fans) TRAC2642A (EC fans) Water 10/15 C, 35 C 20% glycol, average values 25

Availability 26

Design for continuous availability Continuous availability needs specific choices Unit design Exchange surfaces Redundant components and power supply Emergency strategies Component selections Control Strategies Sensors and measurement LAN and BMS connections 27

Wide temperature range up to 80 C Chillers up to +50 C*or higher with unloading procedure Chillers down to -20 C Free-cooling up to +48 C or higher with unloading procedure Free-cooling down to -25/-40 C* *specific option may be required High inlet water temperatures may limit the max ambient temperature operation 28

High speed restart Standard chiller: 7-10 minutes Uniflair TRA* units: full load condition in 2 minutes with double or separate power supply and 3 minutes with standard arrangement 29

Power supply Double power supply with automatic commutation (ATS) for complete redundancy without single point of failure as per TIER recommendations Main line Generator Unit Separate power supply from UPS for Unit and compressor/s control for 2 minutes quick start and emergency operation Automatic double and separate power supply from UPS for redundancy Main Line Generator Unit 30

Monitoring and control system All the units are fitted with a complete set of sensors and devices to guarantee Protection and reliability Phase sequence control Magneto-thermal protection switches with trip alarm signal on compressors Minimum and maximum power supply control Optional absorbed power / amperage acquisition Refrigerant leak detection Integrated LAN 31

Configurability 32

Extremely wide configurability Electronic Expansion Valve Softstart for compressors EC fans Modulating fans Low noise version Inverter driven pumps Glycol free Double power supply with internal ATS Separate power supply Double thermostat for heaters Compressors protection for linked to the control board Min/max volgate relay Refrigerant Leackage sensor Energy current meter Crimped pipeworks RS485 communication card Clock card USB card Double BMS connection 0-10V variable set-point Max external temperature 50 C on Chiller Max external temperature 45 C on Free-cooling TRA* ARA* Standard feature Option On request (ETO) Not available 33

Low starting currents 4 compressors from 150kW allow reduction in strting current Optional compressors soft starters Starting current 30% less 390A 510A Less electrical stress to the unit Lower impact on the electrical lines with benefits to the general reliability of the plant Less CAPEX for the electrical distribution grid 350kW chiller w/o softstart 350kW chiller with softstart 34

VSD on-board pumps TRA* units can be fitted with std or VSD onboard pump/s (1 or 1+1) Head pressure and water flow can be adjusted on site Head pressure and water flow can be dynamically adapted to the real operating conditions Full Start-up load 35

Variable Speed Driven on-board pumps High efficiency, thanks to the continuous speed adaption on the circuit pressure drops flexibility & modularity. It is possible to adapt the head pressure, allowing an on site optimization and modular installations reduction in CApital EXpense, since a single circuit design can be easily applied, saving the extra cost primary/ secondary circuits 36

Power Supply TRA* chillers are available indifferent power supply to cover a worldwide solution Standard arrangement is 400V/3ph/50Hz, while, on request are available different power supply* 380/3/50 460/3/60 380/3/60 *some options/models may not be available 37

Offer management 38

Aquaflair Range Cooling only Axial fans Heat pump Air-cooled Free-cooling Cooling only Fans which can be duct. Heat pump Free-cooling Water-cooled Cooling only Heat pump 39

Product Organization: SKU T R A C T: technological R: rotary scroll A: air-cooled C: cooling only F: free-cooling H: heat pump 40

Aquaflair Uniflair TRAC, TRAF and TRAH Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors 120-350kW