BLU- CIF2 Interface Board

Similar documents
BLU- CIF2 Interface Board

BLU- CIF Interface Board

BLU- CIF Interface Board

Connecting a Cisco Reader Module

CommBox Control Pro & Lite Hardware Manual 1.0

SECIO 64/128/192 User Manual

V-9939C MICROPHONE ADAPTER

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

the Interactive Catalog

INSTALLATION INSTRUCTIONS. This document describes the installation procedure for the SAB-400 and SAB-401 Station Audio Board.

GSV-1A4 M12/2 M12/2. Highlights

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

Blue Point Engineering

BT-1 Series Bluetooth Wireless Audio Module

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Domain 3000 Back Panel

Color Mark Photoelectric Sensor E3S-VS

Omega 4K/UHD Scaler for HDBaseT and HDMI with USB

CS2000 Conference systems

MegaTrak MCU-9000 Harness Wiring

ilock control unit Wiring Manual website: phone: +(48)

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

LM-2 Series Remote Mic/Line Mixer/Control Modules

Telephone Line Monitor USER GUIDE

*740130* 2800, 9500 Series. Cable Companion Motor Power. Cable AC Power. Cable Retrofit Acessories

Utilizing NuVo s Paging & Doorbell Mute Capabilities

TARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation

HAWK MV-4000 Smart Camera

7I44 MANUAL 8 CHANNEL RS-422 INTERFACE

Figure 1. 6-Way JAMMA Switcher

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

L-80 SERIES HOME & COMMERCIAL HIGH-TECH ENTERTAINMENT CENTER DIAGNOSTIC ADDENDUM

INSTALLATION INSTRUCTIONS

VGA EXTENDER USER MANUAL HIT-VGA-CAT5-142WPRO HIT-VGA-CAT5-144WPRO. (Local) HIT-VGA-CAT5-R300WPRO. (Remote)

Motorized Full-HD IR VP Dome Network Camera

Modular Room Control (MRC) Series Expansion Board

SoundwebTM. Installation Guide

GSV-3USBx2 3,5mV/V 4,2V

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/28

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser.

ZDL-V200. Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully.

Simplese. Dual-Source, Four-Zone Audio Distribution System NV-A4S Owners Manual

High Power (15W + 15W) Stereo Amplifier

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Controllers and Switchers

4 Connection and interface

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

Arteor TM Radio/ZigBee

INSTALLATION INSTRUCTIONS. ACB-100 Audio Control Board. This document describes the installation procedure for the ACB-100 Audio Control Board.

Analog Input and Output Options for Syringe Pumps

THE CTB08D LIGHT CONTOLLER

Magnetically Actuated Safety Interlock Switches

508 SERIES MICROPHONE STATIONS

IEI emerge MicroNode Install and Setup Guide. Contents

INSTALLATION INSTRUCTIONS. DCC and DCE Installation Instructions. Table of Contents

4 Connection and interface

Installation Instructions

Arrakis Systems 6604 Powell Street / Loveland, Colorado 80538

ZENSOL CIRCUIT BREAKER PERFORMANCE ANALYZER

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

VGA EXTENDER USER MANUAL V1.0. (Local) (Remote)

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

ilock control unit Wiring Manual website: phone: +(48)

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

4.8 Expansion Module MAC00-FS1/FS4

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

Blue Point Engineering

ATT2 Installation Guide for PQube 3

Security and Convenience Components 519H Three-Channel Receiver

Wash Light User Data. User Data - Specifications Date: 01/11/2016 Page 1/7. RGBW (White 4000k) Single Colour (R,G,B,A,W)

CTR21, CTR22, CTR23, and CTR24 Wall Modules

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Mounting Card MC1XDZR02-HP1

Connecting the THP-700RTS to a Telephone and Radio Console - Summary. DynaMetric. Made in USA THP-700RTS

COLLABORATE Room Pro with Beamforming Microphone Array Professional Conferencing Quick-Start Guide

CONTROL PROTOCOL Motorized Projection Screens

955S BRIK. Series 955S Brik. Smart BRIK LDT ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS. Linear Displacement Transducer

T4HD: Installation Supplement R8.1.13

6222 Two Door Module Technical Operations Manual

Release Note. How to Use the OptoCon Connection Module. 1 Introduction. Option C Revision 4 Revised 8/13/98

Remote units Hands free or telephone handset options available. Master to remote and remote to master calling

ETH-4X1-G / 2X1-G / 2X1

ICM-25 INPUT CONTROL MODULE, 25 INPUTS RS-232(SERIAL) OUTPUT

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

SoundwebTM. Installation Guide

Appendix E: Edge Ti. Overview. Appendix E: Edge Ti 169

DEV-1 HamStack Development Board

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

Instructions - THP-700RTS Telephone Headset Radio Transfer Switch with Dry Switch Closure Output

A0319. Bluetooth Wall-Dock for Distributed Audio. Intelligent Entertainment Infrastructure Security Solutions

CMC Hybrid Connectors Standard and Power Versions

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories

Metra NET Network Installation Manual

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Transcription:

BLU- CIF2 Interface Board The BLU-CIF2 Interface Board simplifies the wiring of all of the BLU products to two BSS Audio London Series Digital Signal Processors. It allows for Cat5e wiring termination, as well as, termination to 3.5mm euro-style blocks. The BLU-CIF2 accommodates connections for two BLU-CC, two BLU-CP, two BLU- CS, up to five BLU-IR, or up to seven BLU-SV / BLU-SV8 plus Emtech MSC-C modules for providing audio in overflow areas. It is designed for mounting on the back door of a 19 rack. BLU-CIF2 Cat5e Wiring Instructions IMPORTANT: IF you are using CAT5e wiring termination with the BLU-CIF2, then the RJ-45 connectors need to be crimped to TIA/EIA 568B Standards (see below) on both ends of the cable. You must crimp and test the wiring with an approved CAT5 568A/B tester before connecting any cable between the BLU Products and the BLU-CIF2 Interface Board. Failure to crimp wiring to the correct standard could possibly lead to component damage. EIA/TIA568B 1. White-Orange 2. Orange 3. White-Green 4. Blue 5. White-Blue 6. Green 7. White-Brown 8. Brown

On the left side of the BLU-CIF2 Interface Board are two 2 X 4 blocks of RJ-45 connectors for terminating the BLU products via Cat5e wiring. The BLU products connect in this order (left to right), starting with Block 1: BLOCK 1 BLOCK 2 BLU-CIF RJ-45 CONNECTIONS TOP ROW BLU-CP1 BLU-CC1A BLU-SV2 BLU-IR2 BTTM ROW BLU-CS/SV1 BLU-CC1B BLU-IR1 BLU-IR3 TOP ROW BLU-IR4 BLU-CP2 BLU-SV4 BLU- CC2A/SV5 BTTM ROW BLU-IR5 BLU-CS2/SV3 BLU-SV7 BLU- CC2B/SV6 BLOCK 1 BLOCK 2 IMPORTANT: If you use the RJ-45 blocks for connecting the BLU- CC, BLU-CP, BLU-CS, BLU-IR and BLU-SV(8) modules, then do not use any of the 3.5mm euro-style connectors for these accessories. If you are using the BLU-IR Infrared Sensors for combining audio in overflow areas, then you have a choice to use either the RJ-45 connections in their blocks or the 3.5mm euro-style connectors. Wiring the BLU-IR Infrared Sensors into the 3.5mm connectors will be covered later on in this document. A legend for the BLU-CIF2 RJ-45 connections has been silkscreened on the Interface Board next to the corresponding block of connectors. BLU-CIF2 3.5mm Euro-block Wiring Instructions The 3.5mm euro-block connectors have been provided for easy installation of the BSS Audio equipment into older buildings with existing analog wiring. Connectors for the BLU-CC, BLU-CP, BLU-CS and BLU-SV have 2

8-pins, and are located behind the RJ-45 blocks on the top half of the board for DSP1, and on the bottom half of the board for DSP2. BLU-CP1 BLU-CS/SV1 BLU-SV2 BLU-CC1A BLU-CP2 BLU-CC1B BLU-CS2/SV3 BLU-SV4 BLU-CC2A/SV5 BLU-CC2B/SV6 BLU-SV7 The legends for identifying and wiring these euro-style connectors have all been silkscreened on the CIF2 Board at the top and bottom side of each connector. The pin-outs for each connector are listed below: BLU-CP1 & CP2 BLU-CS1/SV1 & CS2/SV3 1. Power Button (IN1) 1. Power Button (IN3) 2. Volume (IN2) 2. Volume (IN4) 3. VCC 3. Ref 4. +24V 4. N/A 5. Ref 5. VCC 6. LED (OUT1) 6. LED (OUT2) 7. GND 7. GND 8. GND 8. GND 3

BLU-CC1A & CC2A/SV5 BLU-CC1B & CC2B/SV6 1. Power Button (IN5) 1. Volume (IN6) 2. Volume (IN7) 2. Volume (IN8) 3. Ref 3. Ref 4. N/A 4. N/A 5. VCC 5. N/A (CC1B) or VCC (CC2B/SV6) 6. LED (OUT3) 6. LED (OUT4) 7. GND 7. N/A 8. GND 8. N/A BLU-SV2 & SV4 BLU-SV7 1. SRC (IN10) 1. SRC (IN11) 2. Volume (IN9) 2. Volume (IN12) 3. Ref 3. Ref 4. N/A 4. N/A 5. VCC 5. VCC 6. N/A 6. N/A 7. GND 7. GND 8. GND 8. GND A remote control can be used for controlling the volume of the various microphone inputs in the cultural hall. When wiring for a remote application wire to IN5 thru IN9, Ref and GND on CC1A, CC1B and SV2. BLU-CIF2 / MSC-C Wiring Instructions Some existing buildings already use Emtech MSC-C modules to provide chapel audio for the cultural hall and overflow areas. The BLU-CIF2 is designed to allow these existing modules to interface with the BSS Audio DSP. Located through the middle section of the CIF Board are three 4-pin euro-style connectors. Each connector has identification and wiring designations silkscreened below it. 4

There are no switches associated with the C switch connectors on the new version of CIF2 board. IN11 and IN12 are bit encoded with 4 bits each. C- SW1 and C-SW2 map to IN11, and C-SW3 and IR4-5 map to IN12. When either a C switch or IR get wired to the CIF board, the device will be automatically detected. The pin-outs on the C switch connectors are: C-SW1 thru 3 1. +24V 2. SW1 3. SW2 4. Common USING the C-SW INPUTS WITH BLU-IR INFRARED SENSORS The BLU-IR Infrared Sensors can be wired to the 4-pin C-Switch euro-style connectors. Wire each IR sensor to its corresponding 4-pin connector using this pin-out: C-SW1 thru 3 1. Red 2. Green 3. N/A 4. Black 5

BLU-CIF2 PWR RELAY & OF RELAY Wiring Instructions There are four separate relay connectors on the right side of the CIF2 board. The 2-pin PWR_1 & PWR_2 connections are used to power on external equipment. This connection will supply +24VDC @ 100mA on the +24 pin when logic output 6 on the DSP is triggered. The voltage from the +24 pin is typically connected to an external power relay coil, which will then switch 120VAC on to the external equipment. The PWR RELAY output is thermo-fuse protected, so it will stop supplying power when the +24 pin exceeds 100mA. The circuit will reset automatically once the load is disconnected. The 4-pin OF_1 & OF_2 overflow relay connections are 2-pole dry contacts that are normally open. These contacts will close connecting the + (pin 1) to the + (pin 3), and the - (pin 2) to the - (pin 4), when output port 5 on the DSP is triggered. This is typically used to switch speaker level signals, so an overflow room can be fed directly from an amplifier without needing its own dedicated amplifier channel. Connecting the BLU-CIF2 to the BSS Audio London Series DSP The BLU-CIF2 ships with four pre-fabricated 12-conductor cables. Each cable has 3.5mm connectors on both ends. On one end, the 3.5mm connectors are color-coded green and black, so they match up with either the Control Port 1 for DSP 1 & Control Port 2 for DSP 2 (Black) connector or the Logic Inputs (Green) connectors for DSP1 & DSP2 on the far right side of the CIF2 Board. Control Inputs Connector Logic Outputs Connector 6

Control Inputs connector mates with the cable with Control_Port1 (Black) connector. Logic Outputs connector mates with the cable with Logic Inputs (Green) connector. The 3.5mm connectors on the opposite end of each cable are orange. They match the color of the mating connector on the back of the DSP and are labeled top and bottom, so make sure that the cables are connected correctly on the DSP side. Another way to remember : Black on the board goes to the top connection on the DSP, and Green on the board goes to the bottom connection on the DSP. Make sure that the cables are not crossed DSP1 Control & Logic go to the first DSP and DSP2 Control & Logic go to the second DSP. BLU-CIF2 Power The power jack for the BLU-CIF2 is located on the bottom left side of the board; below the RJ- 45 blocks. The BLU-CIF2 is shipped with a universal desktop power supply that plugs into the power jack, and supplies it with 24VDC @ 1.67A. The power cord on the supply plugs into a standard 120VAC outlet. Power Jack 7