Liebert HPM from 4 kw to 100 kw

Similar documents
Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Liebert PDX from 15 to 120 kw

Liebert PDX from 15 to 120 kw

Precision Cooling for Business-Critical Continuity. Liebert CRV. Efficient Cooling For IT Equipment NEW. Extended Range Available From 10 To 50 kw

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

Liebert PCW. Cool the Cloud

Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert NX from 30 to 60 kw. AC Power for Business-Critical Continuity

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Liebert HPC Freecooling Chiller

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Liebert : The Right Cooling For IT Environments

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Liebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY.

Precision Cooling for Business-Critical Continuity. Liebert HPC-M. The Data Center FreeCooling Chiller with the Lowest Impact on the Environment

Chloride CROSS Rack 16 A, 32 A and 63 A

Smart Solutions Intelligent, Integrated Infrastructure for the Data Center

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

Solutions for Business-Critical Continuity. Emerson Network Power Technology and Solutions for a World in Action

VERTIV SERVICE CAPABILITY

Liebert APM UPS The Industry s Highest Energy Efficiency In A Row-Based, On-line UPS. AC Power For Business-Critical Continuity

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Liebert DCW CATALOGUE

Liebert APM. The Compact Row-Based UPS With FlexPower Technology TM. AC Power for Business-Critical Continuity

Chloride Trinergy from 200 to 1200 kw

SmartMod Intelligent, Integrated Infrastructure for the Data Center

Liebert. DCL up to 35 kw. Modular Rack Cooling

Liebert Load Bus Sync Extender/Adapter for Dual Bus UPS

Liebert STS2/PDU, Static Transfer Switch 2/Power Distribution Unit. A Streamlined Package For Power Distribution And Source Switching

Liebert. DCL up to 35 kw. Modular Rack Cooling

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Rack cooling solutions for high density racks management, from 10 to 75 kw

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Precision Cooling. Precision Cooling Advantages

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert Precision Power Center

Liebert. EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Liebert. CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Ecotel Free Cool 5-15kW

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

Liebert NXC from 10 to 200 kva

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Liebert APM. The Compact Row-Based UPS With Flexpower Technology TM. AC Power for Business-Critical Continuity

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

Emerson Network Power Technology and Solutions for a World in Action

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

Total Modular Data Centre Solutions

Rack & Enclosure Systems

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

Liebert Nfinity. A Powerful UPS Solution For Small To Medium Data Centers. AC Power For Business-Critical Continuity

MSYS 4480 AC Systems Winter 2015

Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

Liebert NX. UPS For Small And Medium Business. AC Power For Business-Critical Continuity

Liebert exm UPS kva/kw Efficient, Flexible Power Optimized for Midsize Applications FLEXIBLE. ECONOMICAL. INTELLIGENT

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Liebert MicroPOD 230V

Data Center Optimized Controls

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

SUPERSAVER. Energy Efficiency Optimization Software for Freecooling Systems

Liebert XD. Cooling Solutions For High Heat Density Applications. Precision Cooling For Business-Critical Continuity

Five Best Practices for Increasing Efficiency, Availability and Capacity: The Enterprise Data Center Design Guide

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

IT Air Conditioning Units

We Invented Precision Cooling

Close-coupled cooling

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

Liebert IntelliSlot Relay Card

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Liebert. PDX and PCW Compact Perimeter Cooling Solutions

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center

Thermal management. Thermal management

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

Liebert. Liebert Deluxe System /3 6 to 30 Tons. Precision Air Conditioning for Sensitive Electronic Equipment

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Liebert XD Flexible, Energy-Saving Cooling Solutions For High Heat Density Applications. Precision Cooling For Business-Critical Continuity

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

Transcription:

Precision Cooling for Business-Critical Continuity Liebert HPM from 4 kw to 100 kw Efficient Direct Expansion Cooling for Data Centers With R410A Refrigerant

Whether a data center houses three or 200 IT racks, deployment of new technologies with high power densities are impacting the power and cooling systems that business-critical servers and communications devices depend on for their performance and reliability. The critical infrastructure systems from Emerson Network Power allow customers to respond to changes in density, capacity and availability while achieving greater operating flexibility, higher system availability and lower total costs of ownership. Emerson Network Power delivers innovative solutions through 12 Centers of Expertise, distinct areas of breakthrough products and services that help determine what is needed in relation to the application. Supported by a global network in more than 150 countries, backed by local service and support from more than 2,000 certified professionals, Emerson Network Power is uniquely positioned to provide systems and integrated solutions wherever our customers are located. Emerson Network Power understands the challenges of setting up the right infrastructure to support business-critical data center operations and helps respond to any demand by providing innovative solutions, allowing customers to concentrate on their business requirements. The Liebert HPM direct expansion cooling unit is equipped with the most advanced industry technology, guaranteeing precise cooling of data centers and server rooms. It comes complete with R410A refrigerant which allows the unit to reach significant levels of efficiency. Liebert HPM incorporates Emerson Network Power's breadth of cooling expertise in a unique range of cabinet air coolers designed to ensure performance and reliability. The Liebert HPM range comes complete with EC Fans as standard, thus ensuring top energy efficiency. The complete unit design has furthermore been optimized with enhanced heat exchangers, delivering a high level of overall efficiency and cooling capacity. In addition, the Liebert HPM also includes unique Digital Scroll technology, making it the ideal, scalable cooling system able to expand with evolving business needs. The Digital Scroll modulating capability greatly contributes to the efficiency levels reached by the Liebert HPM with a 50 kw unit (inclusive of Digital Scroll) consuming as little as a 10 kw unit, thus delivering advantageous energy savings.

Liebert HPM designed for the lowest air resistance

Liebert HPM Technology Delivers Energy Savings of up to 65% Precision Cooling Unit with standard scroll compressor Liebert HPM Digital Scroll Compressor SmartAisle TM Saving up to 65% Saving up to 50% Liebert HPM Digital Scroll + EC Fan Increased motor efficiency + EXV Minimized condensing temperature & enhanced evaporation + Humidifier SHR*=1 eliminating need for humidifier + COP* & SHR* Liebert HPM has higher COP* & SHR* at modulated capacity SmartAisle TM The Liebert HPM's patented software allows modulation of fan speed and cooling capacity, meeting the necessary airflow at the required server temperature, while conserving Watt usage. 1,000 2,000 3,000 4,000 5,000 6,000 7,000 YEARLY ENERGY COST Data Center Set Point: 24 C - 50 rh% Energy Cost: 0.12/kWh A 20 kw Unit equipped with Digital Scroll working at 80% heat load Annual savings achieved by the Liebert HPM, complete with the most advanced technologies in the market (Digital Scroll Compressor, Electronic Expansion Valve, EC Fan) as standalone and integrated with cold aisle containment, compared to Precision Cooling units fitted with standard scroll. Key Benefits Achieved with Liebert HPM Scroll Securing IT Investments Digital Scroll technology delivers increased performance with a greater return on investment while at the same time reducing the demand on energy usage. Targeted Cooling Digital Scroll provides the necessary level of cooling by adjusting its delivery according to the heat load, thus ensuring constant, precise temperature levels. Scalable Architecture the Liebert HPM's scalable architecture adapts to increases in data center density and size, regulating its performance to respond to evolving demands. Unique Technology the Digital Scroll technology guarantees protection for IT infrastructure with maximized energy savings. *COP: coefficient of performance SHR: sensible heat ratio 4

Integrated with SmartAisle, the Liebert HPM is the ideal response to data center cooling demands and maximizing capital investment. Designed for R410A Refrigerant digital scroll Copeland Digital Scroll Technology: the best solution in terms of variable cooling capacity 23 22 21 20 19 18 17 Digital Scroll based technology allows for close monitoring and control of room temperature EC Fans for optimized airflow distribution Precision cooling floor mount products comply with the European ErP 2015 Directive requirements, respecting environmental commitments, while reducing operating costs First class energy efficiency achieved through the combination of market leading technologies Continuous monitoring of heat load ensures that only necessary kilowatts are invested in targeted cooling, thus conserving energy Emerson Network Power supports customers with an extensive service offering, guaranteeing availability and total peace of mind 24/7 5

Constant Cooling Control - Liebert icom control drives the Liebert HPM to the highest efficiency levels. The icom device, featuring a unique control algorithm ensuring top reliability in all conditions, manages the operation of the Liebert HPM units. Liebert HPM units with graphic display may be centrally monitored and controlled with the optional wall mounted display. The display allows access to the unit via the Network, making coordination between the Liebert HPM units within the same room possible as a result of the integrated Ethernet connection.the self monitoring of redundant units alternates standby positions and gives priority to possible hot spots. The high-level supervision of multiple units allows them to work together as a single system to optimize room temperature and humidity. This is of particular importance when the EC Fan is considered. EC fan power consumption functions according to the square-cube law, so that having five units running at 80% instead of four at 100%, means the energy used by the additional unit is cut by 50% and the total energy used by the entire group by 36%. icom manages the reduction of fan speed whenever operation at full capacity is not required. 6

Smart mode is a control algorithm developed for SmartAisle TM applications, (Cold Aisle containment) meeting the exact cooling and airflow needs of the servers without wasting a single Watt on unnecessary cooling or air movement. Unit to Unit Communication icom directly connects with the facility network (Ethernet) and enables communication between multiple Liebert HPM units for synchronized operation, guaranteeing higher reliability and precision cooling room control. 7

Liebert HPM's integration in the SmartAisle TM configuration achieves energy savings of up to 65% Standard unit Traditional Approach Digital Unit Traditional Approach With Cold Aisle Containment With SmartAisle Compressor 61.1% 35.4% 30.3% 27.2% Condenser 4.9% 4.9% 4.9% 4.9% Evaporator Fan 18.6% 9.7% 6.8% 2.1% Humidifier 15.4% 1.2% 1.2% 1.2% Total 100% 51.2% 43.2% 35.4% Total Saving Saving 49% Saving 57% Saving 65% Integration with SmartAisle TM, Emerson Network Power's cold aisle containment solution, can achieve an energy saving of up to 65% higher than other manufacturers' cooling units with standard technology. The intelligent control of the Digital Scroll compressor capacity together with accurate fan speed management, driven by cold aisle conditions, guarantees increased savings. 1 SmartAisle Cold Aisle Containment The physical separation of cold and warm air zones using SmartAisle technology. Aisle Containment ensures that the cold air distributed through the raised floor is delivered directly to IT cabinets. The SmartAisle containment solution also incorporates enhancements in cooling efficiency which can be achieved using the following equipment: Cable entry sealing systems Cabinet sealing with trims and blanking panels High airflow perforated floor tiles with up to 85% perforation. 2 icom with SmartAisle TM Control Logic A cooling unit with SmartAisle control logic ensures the correct airflow, air *SHR: sensible heat ratio temperature and humidity required by IT equipment. Dynamic fan speed and cooling capacity control further provide maximum cooling efficiency. 3 Liebert HPM Liebert HPM's Digital Scroll compressor delivers the exact level of required air temperature while the EC Fans manages the desired airflow. This ensures that only the necessary kilowatts of input power are used to cool the IT load. Units which include the Alco Electronic Expansion Valve, are able to further increase overall system efficiency by reducing the condensing temperature during cooler seasons and at the same time preserving the SHR*. 4 Liebert HPA Liebert HPA is a remote air cooled condenser for room-based precision cooling units which is equipped with variable fan speed control, specifically developed for Digital Scroll units. This solution maximizes system efficiency and minimizes, annual energy consumption. 5 Racks & Integrated Cabinets Emerson Network Power's Knürr server racks allow for flexible installation of accessories, as well as a complete cable management system. The server rails guarantee simplified installation of all types of 19 servers and related accessories. 8

4 1 2 3 5 9

Liebert HPM: Remote Monitoring Service and Connectivity LIFE.net Remote Monitoring and Diagnostic Service It is essential that your critical cooling system is maintained in an optimum state of readiness at all times. With LIFE.net remote monitoring and diagnostics, Emerson Network Power Services monitor and prevent possible alarm conditions. This allows effective proactive maintenance and fast incident response, giving customers complete security and peace of mind. Service center engineers are permanently on hand to provide immediate fault analysis and appropriate corrective action. The customer will be informed about the status of the installation through detailed reporting providing valuable information on unit functioning and trends over any selected period of time. Basic Web Access SiteScan Web Control, Data Capture, Energy Management and Planning LIFE.net Advanced Access With Intellislot Card Monitoring and Alarm Notification Through Liebert Nform 10

Basic Web Access Basic operational information can be made available through the monitoring feature offered by the icom Control over Ethernet. A web browser is the only requirement needed for the unit to communicate directly with the local or remote web interface. Monitoring and Control Through Existing Network Via your Web Browser The Liebert HPM system can be fitted with a Liebert IntelliSlot Web Card allowing full advantage to be taken of the Ethernet network and remote monitoring from your computer desktop, network operations center or any network access simply utilizing a standard web browser. A standard web browser, via HTTP protocol or Network Management System software via SNMP protocol, can be used to access the unit information. Monitoring Integration with Existing Building Management System If required, Liebert HPM may be integrated with an existing Building Management System, while the IntelliSlot 485 Cards provide Modbus RTU and Modbus TCP compatibility. SCADA support is completed through the Bacnet over IP card. Liebert Nform Software Centralized Management As business grows, critical equipment infrastructure expands, thus the need for centralized management of any equipment is key to business success. Connecting to equipment in the distributed critical space is only part of the monitoring challenge. Liebert Nform leverages the network connectivity capabilities of Liebert HPM to provide centralized monitoring of the distributed equipment. Utilizing the SNMP and Web technologies integrated in each Liebert IntelliSlot communication card, Liebert Nform centrally manages alarm notifications and provides an intuitive interface to access critical status information. Liebert Nform allows critical system information to be readily available to support personnel wherever they are, increasing responsiveness to alarm-event conditions, thus allowing IT organizations to maximize their system availability. Liebert SiteScan Web Control, Data Capture, Energy Management and Planning For customers who require extensive management of critical system equipment spanning multiple locations in an evermoving global enterprise, Liebert SiteScan Web will centrally manage critical equipment and give the power to move beyond the event responsive service paradigm. Liebert SiteScan Web does it all Real-Time Monitoring and Control Event Management and Reporting Data Analysis and Trending Building Management Integration Liebert SiteScan Web is a comprehensive critical system management solution dedicated to ensuring reliability through graphics, event management and data export. The standard Web interface allows users easy access from anywhere, anytime. 11

Liebert HPM Application Scenarios Liebert HPM Downflow Downflow units are ideal for raised floor installation environments which are commonly found in data center applications. The Downflow unit optimizes performance in all such applications, delivering the highest efficiency of the Liebert HPM range, which can be further maximized with Digital Scroll. Suitable for: Raised Floor SmartAisle Liebert HPM Upflow Upflow units are designed for use in applications with top directed air distribution, including or excluding ducting systems. The inclusion of EC Fans means that the Liebert HPM Upflow is able to deliver the highest External Static Pressure (ESP), while limiting power input and maximizing output. This combination allows the Liebert HPM to deliver optimized cooling requirements, while at the same time providing the most suitable airflow and ESP to meet individual installation requirements. Suitable for: Ducted Applications Application with limited raised floor air distribution capabilities or where raised floor is not available Technical rooms Liebert HPM Displacement Displacement units take their name from the displacement effect. It consists of the stratification of cold air in the lower section of the room, and hot air in the upper section. This is achieved by delivering cooled air at a very low speed. The displacement effect considerably contributes to system efficiency. The Liebert HPM Displacement unit is best suited to small applications where scalability and capacity growth are key. Suitable for: Application without raised floor Technical rooms Small data rooms with cooling installed opposite racks 12

Liebert HPM Cooling Configurations Liebert HPM Air Cooled Air cooled direct expansion units optimize condensing temperature in the simplest installation configurations and with minimized site impact. Liebert HPM Water Cooled The Liebert HPM Water Cooled is the ideal configuration for leveraging the digital benefits of applications with significant distances between internal and external units, or those with variations in geodetic height. Liebert HPM Dual Fluid Air Cooled Ideal for chilled water based applications which transition between Air Conditioning and Precision Cooling, the Liebert HPM Dual Fluid Air Cooled configuration, offers efficient direct expansion cooling that works as redundant cooling for chilled water coils. Liebert HPM Dual Fluid Water Cooled This cooling configuration perfectly adapts to any installation layout, therefore chillers and dry coolers can be placed wherever necessary on the site. Liebert HPM Freecooling For all applications where efficiency is a prime objective, the Liebert HPM offers the possibility of leveraging the Freecooling effect for the longest period of time, as a result of its enhanced coil distribution. The flexibility of the Liebert HPM Freecooling configuration ensures the highest energy savings and efficiency in variable working conditions including DX mode. 13

Liebert HPM Range and Performance Single Circuit Room Unit Model D1E D1G D2E D3A D3G D4E Condenser Model HCR24 HCR24 HCR43 HCR43 HCR43 HCR59 Total gross cooling capacity kw 15.8 17.4 23.9 29,0 34.9 44.1 Net sensible cooling capacity kw 13.9 15.9 20.5 25.2 33.0 40.4 SHR* at full load 0.92 0.95 0.92 0.92 0.98 0.96 SHR* at 80% load 1.00 1.00 1.00 1.00 1.00 1.00 Net sensible EER at full load Net sensible EER at 80% load 3.2 3.1 3.0 3.1 3.4 3.2 3.4 3.2 3.1 3.1 3.4 3.2 Airflow m 3 /h 4.200 4.930 5.750 7.080 9.540 11.230 Max. ESP Pa 400 380 190 200 400 320 Sound pressure level at 2 meters in f.f. conditions Minimum net sensible capacity during modulation Internal Unit Dimensions (W x D) External Unit Dimensions (W x D) db(a) 48.8 49.2 50.0 55.4 55.8 57.4 kw 3.2 4.1 5.1 6.2 8.6 9.9 mm 750 x 750 750 x 750 750 x 750 1000 x 850 1750 x 850 1750 x 850 mm 1112 x 1340 1112 x 1340 1112 x 1340 1112 x 2340 1112 x 2340 1112 x 2340 Weight Internal Unit kg 240 250 270 415 570 600 Weight External Unit kg 75 75 92 92 92 102 Airflow Delivery (downflow, upflow, displacement/frontal) D, U, F* D, U, F* D, U, F* D, U, F* D, U* D, U* Performance at 24 C 50% Nominal ESP 20 Pa External Temperature 35 C System able to work at up to 40 C external temperature with condenser models as shown; higher ambient operating temperatures available with alternative condenser selections. Internal Unit Height 1950 mm; External Unit Height 907 mm *SHR: sensible heat ratio D: downflow U: upflow F: frontal 14

Liebert HPM Range and Performance Double Circuits Room Unit Model D3F D4H D5D D7L D8F Condenser Model 2 x HCR24 2 x HCR33 2 x HCR43 2 x HCR43 2 x HCR51 Total gross cooling capacity kw 36.3 45.1 58.4 65.2 81.3 Net sensible cooling capacity kw 34.0 41.5 49.4 53.4 71.0 SHR* at full load 0.97 0.96 0.90 0.87 0.93 SHR* at 80% load 1.00 1.00 1.00 0.95 1.00 Net sensible EER at full load Net sensible EER at 80% load 3.4 3.2 3.0 2.8 2.7 3.6 3.4 3.2 3.1 2.8 Airflow m 3 /h 9.490 11.370 12.910 13.470 20.020 Max. ESP Pa 400 310 200 150 120 Sound pressure level at 2 meters in f.f. conditions Minimum net sensible capacity during modulation Internal Unit Dimensions (W x D) External Unit Dimensions (W x D) db(a) 56.0 58.3 58.7 58.5 67.4 kw 3.5 4.2 4.8 5.3 6.8 mm 1750 x 850 1750 x 850 1750 x 850 1750 x 850 2550 x 890 mm 2 x (1112 x 1340) 2 x (1112 x 1340) 2 x (1112 x 2340) 2 x (1112 x 2340) 2 x (1112 x 2340) Weight Internal Unit kg 580 585 620 645 950 Weight External Unit kg 2 x 75 2 x 80 2 x 92 2 x 92 2 x 93 Airflow Delivery (downflow, upflow, displacement/frontal) D, U* D, U* D, U* D, U* D* Performance at 24 C 50% Nominal ESP 20 Pa External Temperature 35 C System able to work at up to 40 C external temperature with condenser models as shown; higher ambient operating temperatures available with alternative condenser selections. Internal Unit Height 1950 mm; External Unit Height 907 mm *SHR: sensible heat ratio D: downflow U: upflow F: frontal 15

Liebert HPM Range and Performance Single Circuit Model S0F S0H S1A S1D S1E S1G S2E S2G M2H M3A M3G M4E M5B Sel. Condenser HCR10 HCR14 HCR17 HCR24 HCR24 HCR24 HCR43 HCR43 HCR43 HCR43 HCR43 HCR59 HCR76 Total gross cooling capacity kw 5.6 7.2 10.6 13.0 15.6 17.4 23.1 25.0 24,6 28.8 35.1 43.8 50.7 Net sensible cooling capacity kw 5.1 7.0 9.8 10.9 13.8 15.6 19.9 21.5 22.5 25.5 33.8 40.0 45.2 SHR* 0.93 1.00 0.94 0.86 0.93 0.95 0.90 0.92 0.96 0.94 1.00 0.96 0.94 Net sensible EER 2.6 3.0 3.1 2.9 3.3 3.1 3.1 3.0 3.3 3.1 3.5 3.3 3.0 Airflow m 3 /h 1.560 2.500 2.680 2.750 4.200 4.930 5.200 5.750 6.340 7.080 9.540 11.230 12.250 Max. ESP Pa 300 240 190 140 400 380 280 190 300 200 400 320 260 Sound pressure level db(a) 56,2 50,8 52,9 53,3 48.8 49.4 52.7 50.0 54.1 55.4 55.8 56.5 57.1 Internal Unit Dimensions (W x D) mm 750 x 400 750 x 500 750 x 500 750 x 500 750 x 750 750 x 750 750 x 750 750 x 750 1000 x 850 1000 x 850 1750 x 850 1750 x 850 1750 x 850 External Unit Dimensions (W x D) mm 701x 599 1050 x 891 1050 x 891 1112 x 1340 1112 x 1340 1112 x 1340 1112 x 1340 1112 x 1340 1112 x 2340 1112 x 2340 1112 x 2340 1112 x 2340 1112 x 3340 Weight Internal Unit kg 170 195 210 215 240 250 260 270 425 430 580 600 620 Weight External Unit kg 16 44 44 75 75 75 92 92 92 92 92 102 136 Airflow Delivery (downflow, upflow, displacement/frontal) D, U, F* D, U, F* D, U, F* D, U, F* D, U, F* D, U, F* D, U, F* D, U, F* D, U, F* D, U, F* D, U* D, U* D, U* Performance at 24 C 50% Nominal ESP 20 Pa External Temperature 35 C System able to work at up to 40 C external temperature. Internal Unit Height 1950 mm; External Unit Height 907 mm *SHR: sensible heat ratio D: downflow U: upflow F: frontal 16

More than 35,000 organizations in 70 countries depend on our Business - Critical Continuity Promise: your IT infrastructure stays up to support your Business! Liebert HPM Range and Performance Double Circuits Model M3F M4H M5C M5D M7L L8F L9H Sel. Condenser 2 x HCR24 2 x HCR33 2 x HCR43 2 x HCR43 2 x HCR43 2 x HCR51 2 x HCR76 Total gross cooling capacity kw 34.5 45.3 49.8 57.9 66.7 80.1 96.8 Net sensible cooling capacity kw 33.2 41.6 44.6 49.2 53.0 69.6 78.7 SHR* 1.00 0.96 0.95 0.90 0.85 0.94 0.88 Net sensible EER 3.5 3.1 3.1 3.0 2.7 2.7 2.6 Airflow m 3 /h 9.490 11.370 12.240 12.910 13.470 20.020 21.100 Max. ESP Pa 400 310 250 200 150 120 70 Sound pressure level db(a) 56.0 56.2 57.3 58.7 60.0 67.4 66.7 Internal Unit Dimensions (W x D) External Unit Dimensions (W x D) mm 1750 x 850 1750 x 850 1750 x 850 1750 x 850 1750 x 850 2550 x 890 2550 x 890 mm 2 x (1112 x 1340) 2 x (1112 x 1340) 2 x (1112 x 2340) 2 x (1112 x 2340) 2 x (1112 x 2340) 2 x (1112 x 2340) 2 x (1112 x 3340) Weight Internal Unit kg 590 600 635 650 670 950 1000 Weight External Unit kg 2 x 75 2 x 80 2 x 92 2 x 92 2 x 92 2 x 93 2 x 136 Airflow Delivery (downflow, upflow, displacement/frontal) D, U* D, U* D, U* D, U* D, U* D* D* Performance at 24 C 50% Nominal ESP 20 Pa External Temperature 35 C System able to work at up to 40 C external temperature. Internal Unit Height 1950 mm; External Unit Height 907 mm *SHR: sensible heat ratio D: downflow U: upflow F: frontal 17

Emerson Network Power Data Center Infrastructure for Small and Large Applications Liebert HPC Wide range of high efficiency Freecooling Chillers from 60 kw to 1600 kw Designed specifically for data center applications and to work with SmartAisle TM Premium energy efficiency version icom control featured Liebert HPM - Liebert PCW From 4 kw to 230 kw, DX-Digital Scroll-CW Premium energy efficiency Eurovent certified performance Unique control capabilities with icom Liebert CRV Row-based high efficiency precision cooling units available in DX or CW versions Decoupled control for airflow and cooling capacity Modulating cooling capacity with digital scroll icom control with remote rack sensors 18

SmartAisle Aisle containment Provides highest energy efficiency Works with any Liebert cooling unit Service Emerson Network Power supports Business-Critical Continuity with the largest global services organization in the industry and a service offering dedicated to entire critical infrastructure, delivering: Design, installation and startup Warranty service Preventive maintenance 24/7 remote monitoring Emergency service Site audits Service contracts Regular service of business critical infrastructure provides uptime assurance and reduces the total cost of ownership over the life of equipment. A service contract ensures that infrastructure is regularly maintained in order to avoid unexpected, costly downtime. Emerson Network Power service contracts cover all technologies and can be tailored to suit individual business needs. Liebert XD Refrigerant based high density cooling installed close to the server Hot spot management for up to 30 kw per rack On-demand upgrade with plug and play High efficiency and 100% sensible cooling LIFE.net Maximized system availability via real-time diagnosis and resolution of operating anomalies 24-hour real-time monitoring by expert engineers Monitoring and trending of system data Diagnosis through expert data analysis allowing effective proactive maintenance and prevention of future anomalies Alarm notification On-site corrective maintenance dispatching 19

Ensuring The High Availability Of Mission-Critical Data And Applications. About Emerson Network Power Emerson Network Power, a business of Emerson (NYSE:EMR), protects and optimizes critical infrastructure for data centers, communications networks, healthcare and industrial facilities. The company provides new-to-the-world solutions, as well as established expertise and smart innovation in areas including AC and DC power and renewable energy, precision cooling systems, infrastructure management, embedded computing and power, integrated racks and enclosures, power switching and controls, and connectivity. Our solutions are supported globally by local Emerson Network Power service technicians. Learn more about Emerson Network Power products and services at www.emersonnetworkpower.com Locations Emerson Network Power Via Leonardo Da Vinci 16/18 Zona Industriale Tognana 35028 Piove di Sacco (PD) Italy Tel: +39 049 9719 111 Fax: +39 049 5841 257 cooling.networkpower.eu@emerson.com Via Fornace, 30 40023 Castel Guelfo (BO) Italy Tel: +39 0542 632 111 Fax: +39 0542 632 120 enquiries.chloride@emerson.com United States 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Tel: +1 614 8880246 While every precaution has been taken to ensure accuracy and completeness of this literature, Emerson Network Power and/or its affiliates makes no representations or warranty about the accuracy, reliability, completeness, or timeliness of the materials and disclaims any and all liability for damages resulting from use of this information or for any errors or omissions. Asia 7/F, Dah Sing Financial Centre 108 Gloucester Road, Wanchai Hong Kong Tel: +852 2572220 Fax: +852 28029250 2012 Emerson Network Power. All rights reserved. Specifications subject to change without notice. MKA4L0UKHPM Rev.1-07/2012 Emerson Network Power The global leader in enabling Business-Critical Continuity EmersonNetworkPower.com AC Power Connectivity DC Power Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. 2012 Emerson Electric Co.