A9GT-J71E71-T type Ethernet communication module

Similar documents
A9GT-50WQBUSS/A9GT-50WBUSS type Bus Connection Communication Board

Model A9GT-70LTS Back Light

2002 No.187E NEW PRODUCT RELEASE Q32SB, Q33SB, Q35SB Slim Type Main Base Unit Q61SP Slim Type Power Supply Module New!

DeviceNet Master -Slave Module

PROFIBUS-DP Master Module

A1SD75M1/M2/M3 Positioning Module

A1SD75M1/M2/M3 Positioning Module

PROFIBUS-DP Slave Module

10BASE5 Dedicated Type Q Series Ethernet Interface Module is now available You can now select the optimum Ethernet interface module for your system.

GT15 CC-Link communication unit

MITSUBISHI Mitsubishi PLC Mitsubishi Integrated FA Software Type QD70 Positioning Modules GX Configurator-PT Version 1 SW1D5C-QPTU-E New!

Model AJ71DN91/A1SJ71DN91 DeviceNet Master Module

Introducing remote I/O modules with switchable input response time specific to application requirements! Features

MITSUBISHI Mitsubishi PLC

A1SD75P1-S3/P2-S3/P3-S3 Positioning Module

MITSUBISHI No.155E NEW PRODUCT RELEASE. Mitsubishi PLC Release Announcement of the New Model QJ71E Ethernet Interface Module New!

CC-Link IE Controller Network Module

Q66AD-DG. Channel Isolated Analog-Digital Converter Module (With Signal Conditioning Function) User s Manual. (Hardware)

MITSUBISHI GENERAL-PURPOSE PROGRAMMABLE LOGIC CONTROLLER

PROFIBUS-DP Master Module

MITSUBISHI Mitsubishi PLC

MITSUBISHI GENERAL-PURPOSE PROGRAMMABLE LOGIC CONTROLLERS

MITSUBISHI GENERAL-PURPOSE PROGRAMMABLE LOGIC CONTROLLER

MITSUBISHI Mitsubishi Integrated FA Software

Digital-Analog Converter Module

2002 No.179E NEW PRODUCT RELEASE MITSUBISHI. Open Field Network CC-Link. AJ65MBTL1N-16DT, AJ65MBTL1N-16D, AJ65MBTL1N-16T Embedded I/O Adapters New!

DC I/O Conversion Module FA-TB32XY

DC I/O Conversion Module

A975GOT-TBA/TBD(-B) A970GOT-TBA/TBD(-B) A970GOT-SBA/SBD A970GOT-LBA/LBD A960GOT-EBA/EBD

Additional Explanation for A851GOT Graphic Operation Terminal

64.5" LCD Display Monitor

Specifications. 2.1 General Specifications. Operating ambient temperature 0 to 40 C Storage ambient temperature -20 to 60 C

MITSUBISHI Mitsubishi PLC

Mitsubishi Programmable Controllers

AJ65BT-D75P2-S3. Positioning Module

AJ71E71-S3 Ethernet Interface Module (Hardware)

Programmable Controller Analog Terminal Block Conversion Module FA1-TBS40ADGN, FA1-TBS40ADDG, FA1-TBS40DAG User's Manual

Thank you for buying the MELSEC-GOT Series

FL-net(OPCN-2) Interface Module

1) Indicates that the identified danger WILL cause physical and property damage.

MELSECNET/MINI-S3 - CC-Link Module Wiring Conversion Adapter

FX 3 series CPU Catalog

OPC-VG1-PG / PGo. PG Interface Card for FRENIC-VG. Instruction Manual

ERNT-AQTX10 ERNT-AQT68AD-GH. User s Manual. Mitsubishi General-Purpose Programmable Logic Controller Renewal Tool Conversion Adapter.

YASKAWA AC Drive-J1000 Option. RS-232C Interface. Technical Manual Type SI-232/J, SI-232/JC RS-232C SI-232/J, SI-232/JC J1000

CC-Link System Spring Clamp Terminal Block Type Repeater Hub Module

Solder terminals D2FD-2L0-1H D2FD-01L0-1H. PCB terminals D2FD-2L0-1T D2FD-01L0-1T. Hinge lever Solder terminals D2FD-2L1-1H D2FD-01L1-1H

ERNT-AQTD61 ERNT-AQTD61 ERNT-AQTD61. User s Manual. Mitsubishi General-Purpose Programmable Controller Renewal Tool Conversion Adapter.

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

DC I/O Conversion Module

Digital-Analog Converter Module Type AJ65VBTCU-68DAVN

Output Terminal Module

DC I/O Conversion Module

FX1N-2EYT-BD Output Expansion Board

FX 3 series CPU Catalog

You need the following to set up and use your terminal block:

Hard Disk Unit for PC CPU Module Compatible with MELSEC-Q Series PPC-HDD(MS)A User s Guide

PROFIBUS-DP INTERFACE UNIT INSTRUCTIONS

FX1N-4EX-BD Input Expansion Board

YASKAWA AC Drive-J1000 Option RS-232C Interface. Technical Manual Type SI-232/J, SI-232/JC

MELSEC iq-r CPU Module User's Manual (Startup)

MELSEC FX The world s favorite micro PLCs

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Safety Precautions A good safety practice is to expect that hazardous voltage is present in any unknown circuit before measuring.

Guidelines for the Safety of the User and Protection of the F940WGOT Series.

RoD Actuator NEW CRES. Low-cost, User Friendly Actuator Dust-proof and Waterproof Spec Compliant with IP55 Standard. CATALOG No.

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

VS-616PC5/P5 Option Instruction Manual

MELSEC iq-r Analog-Digital Converter Module User's Manual (Startup) -R60AD4 -R60ADV8 -R60ADI8

MELSEC iq-r PROFIBUS-DP Module User's Manual (Application) -RJ71PB91V

Conductive Level Controller

Model 2380 Rack-Mount Kit

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

TBX-96 TERMINAL BLOCK

FEATURES FEATURES. Macro Function Usage Supports strong Visual Basic script language which includes more than 500 built-in functions.

Installation Manual Type AO-A3

GE A Acoustic Belt Tension Tester. User s Operation Manual

MELSEC iq-r Channel Isolated Thermocouple Input Module/Channel Isolated RTD Input Module User's Manual (Startup) -R60TD8-G -R60RD8-G

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

MELSEC iq-r DeviceNet Master/Slave Module User's Manual (Startup) -RJ71DN91

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

MELSECASeries A(1S)J71E71N3-T, A(1S)J71E71N-B5, A(1S)J71E71N-B2. Ethernet Interface Module. Programmable Logic Controller. User's Manual (Hardware)

MELSEC iq-r EtherNet/IP Network Interface Module User's Manual (Application) -RJ71EIP91

CC-Link IE Field Network Basic Compatible Products

Industrial Managed Switch User's Manual -NZ2MHG-T8F2

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

series USER S MANUAL MICREX-F Personal Computer Loader Adapter <Type:FLT-ASFKA >

Allen-Bradley Drives

Delta Multifunction Pressure Sensor DPA Series

MELSEC iq-r DeviceNet Master/Slave Module User's Manual (Application) -RJ71DN91

MELSEC-Q High Speed Analog-Digital Converter Module User's Manual -Q64ADH

FX2NC-ENET-ADP Ethernet adapter USER'S MANUAL

FX2N-4AD-PT SPECIAL FUNCTION BLOCK

MELSEC iq-r Digital-Analog Converter Module User's Manual (Startup) -R60DA4 -R60DAV8 -R60DAI8

MELSEC iq-r Channel Isolated Analog-Digital Converter Module User's Manual (Startup) -R60AD8-G -R60AD16-G

1. Safety Precautions (Read these precautions before use.)

Model 2657A-LIM-3 LO Interconnect Module

Guidelines for the Safety of the User and Protection of the F94*GOT-*WD-E

User s Manual. (Hardware) MODEL A950GOT-U(H/W) MODEL CODE 1DM101 IB(NA) I(0608)MEE. Thank you for choosing the MELSEC-GOT Series.

Transcription:

A9GT-J71E71-T type Ethernet communication module User s Manual (Hardware) Thank you for buying the MELSEC-GOT Series. Prior to use, please read both this manual and detailed manual thoroughly and familiarize yourself with the product. MODEL A9GT-J71E71-T-U MODEL CODE 1DM129 IB(NA)-0800199-D(0408)MEE MITSUBISHI Graphics Operation Terminal

SAFETY PRECAUTIONS (Read these precautions before using.) When using Mitsubishi equipment, thoroughly read this manual and the associated manuals introduced in this manual. Also pay careful attention to safety and handle the module properly. These precautions apply only to Mitsubishi equipment. Refer to the CPU module user's manual for a description of the PLC system safety precautions. These SAFETY PRECAUTIONS classify the safety precautions into two categories: "DANGER" and "CAUTION". DANGER CAUTION Procedures which may lead to a dangerous condition and cause death or serious injury if not carried out properly. Procedures which may lead to a dangerous condition and cause superficial to medium injury, or physical damage only, if not carried out properly. Depending on circumstances, procedures indicated by CAUTION may also be linked to serious results. In any case, it is important to follow the directions for usage. Store this manual in a safe place so that you can take it out and read it whenever necessary. Always forward it to the end user. [DESIGN PRECAUTIONS] DANGER Do not bundle control lines or communication wires together with main circuit or power lines, or lay them close to these lines. As a guide, separate the lines by a distance of at least 100 mm (3.94 inch) otherwise malfunctions may occur due to noise. [INSTALLATION PRECAUTIONS] DANGER Before mounting or dismounting this module to or from the GOT, always shut off GOT power externally in all phases. Not doing so can cause a module failure or malfunction. Before connecting the Bus connection cable to this module, always shut off GOT power and PLC CPU power externally in all phases. Not doing so can cause a malfunction. CAUTION Use this module in the environment given in the general specifications of the GOT User's Manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration. When installing this unit to the GOT, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range. Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to GOT or screw damage.

[STARTUP AND MAINTENANCE PRECAUTIONS] DANGER Before starting cleaning, always shut off GOT power. Not doing so can cause a module failure or malfunction. CAUTION Do not disassemble or modify any module. This will cause failure, malfunction, injuries, or fire. Do not touch the conductive areas and electronic parts of this module directly. Doing so can cause a module malfunction or failure. Exercise care to avoid foreign matter such as chips and wire offcuts entering the module. Not doing so can cause a fire, failure or malfunction. Always secure the cables connected to the module, e.g. run them in conduits or clamp them.not doing so can cause module or cable damage due to dangling, moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault. Do not hold the cable part when unplugging any cable connected to the module. Doing so can cause module or cable damage or a malfunction due to a cable contact fault. Before handling the unit, touch a grounded metal or similar object to discharge the static electricity from the human body. Failure to do so may cause the unit to fail or mulfunction. [DISPOSAL PRECAUTIONS] CAUTION When disposing of the product, handle it as industrial waste. Manuals The following manuals are relevant to this product. Refer to the following list and order the required manuals. Detailed Manuals Manual name A985GOT/A975GOT/A970GOT/A960GOT User s Manual (Available as option) A950GOT/A951GOT/A953GOT/A956GOT User s Manual (Available as option) Manual No. (Model code) SH-4005 (1DM099) SH-080018 (1DM103) Relevant Manual For relevant manual, refer to the PDF manual stored within the drawing software.

1. Overview This User's Manual describes the A9GT-J71E71-T type Ethernet communication module (hereinafter, A9GT-J71E71-T). The A9GT-J71E71-T is required when performing Ethernet connection or Gateway function with GOT. For details of the Ethernet connection, Refer to the GOT-A900 Series User s Manual (GT Works Version5/GT Designer Version5 compatible Connection System Manual). For details of Gateway function, Refer to the GOT-A900 Series Operating Manual (GT Works Version5/GT Designer Version5 compatible Gateway Functions Manual). After opening the box, check that the following items are present. Description Quantity A9GT-J71E71-T 1 Install all relevant operating systems (Standard monitor OS/Communication driver/extended function OS (Ver. 9.0.0 or later)) and ROM_BIOS (Ver.9.0.2 [S] or later) contained in version 26C or later of GT Works Version5 or GT Designer Version5 into the GOT, for A9GT-J71E71-T with hardware version E (2002, June) or later.(the product will not work with the operating system contained in version 13P to 22Y of GT Works Version5 or GT Designer Version5.)

2. Specification 2.1 General Specifications Item Operating ambient temperature Storage ambient temperature Operating ambient humidity Storage ambient humidity Vibration resistance 0 to 55 C -20 to 60 C 10 to 90 % RH, non-condensing 10 to 90 % RH, non-condensing Conforms to JIS B3502 and IEC 61131-2 In case of intermittent vibration In case of continuous vibration Specifications Frequency Acceleration Amplitude 10 to 57 Hz 0.075 mm 57 to 150 Hz 9.8 m/s 2 10 to 57 Hz 0.035 mm 57 to 150 Hz 4.9 m/s 2 Conforms to JIS B3502, IEC 61131-2 (147 m/s 2, 3 times in each of X, Y and Z directions) Sweep Count 10 times in each of X, Y and Z directions (for 80 minutes) Shock resistance Operating No corrosive gas atmosphere Operating 2000 m (6562 ft) max. altitude Installation site Inside control box Overvoltage II or less category 1 Contamination 2 or less level 2 1: Indicates the element in the distribution system between the public electricity grid and the mechanical equipment inside the premises that the relevant device is assumed to be connected to. Category II applies to devices such as those that draw their power supply from fixed installations. The surge voltage withstand capability of devices with ratings up to 300V is 2,500V. 2: This index gives a measure of the incidence of conductive materials in the environment in which the device is used. A contamination level of 2 indicates an environment in which there is only contamination by non-conducting materials, but due to occasional condensation, conductivity may occur. 3: Please do not use or store A9GT-J71E71-T in an environment with atmospheric pressure greater than the atmospheric pressure at sea level (0m). There is a possibility errors may occur if this point is not observed.

2.2 Specification of the A9GT-J71E71-T The performance specifications of the A9GT-J71E71-T is shown below. Transmission specifications Item Specification Data transmission speed 10Mbps Transmission method Base band Maximum node to mode distance 4000m (13124ft) Maximum segment length 100m (328.1ft) Maximum number of nodes 1024units/all hubs (12units) Number of GOTs connected 128 (Recommend 16 or less) 1 2 Connecting condition GOT placing distance 100m 1 Internal consumed current (5VDC) [ma] 50 Weight [g](lb) 160 (0.35) 1: This depends on the specifications of the Ethernet network system to which the GOT is connected. For the details, refer to the manual of Ethernet module you use. 2: If multiple network equipments (including GOT) are connected within a segment, the network load would increase. In such condition, the communication performance between GOT and PLC may be declined. The decline of the communication performance may be improved by the following measures. Using switching hubs. Applying the high-speed 100BASE-TX (100Mbps) for PLC and other equipments (excluding GOT). Reducing the number of monitoring devices of the GOT. 2.3 Specifications of the related devices Use the connection cable and the hub which meet the IEEE802.3 10BASE-T standard. Item Specifications Cable Non-shielded twisted pair wire (category3(4, 5)) Connector RJ45jack Hub 10Mbps hub

3. Name of the Parts and Outline Dimension Drawing 3) 2) 4) 99 (3.90) (*1) R1 149 (5.87) 30.2 (1.19) 1) No. Name Description 1) Cable connection connector Connector for connection of cable 2) GOT connection connector Connector for connection to the GOT LEDs indicate transmit/receive state of data. ( : Off : Flashing) SD RD Description No transmit/receive data. GOT being reset. 3) LED display Communication driver for Ethernet connection has not been installed into GOT. Data being received Data being transmitted Data being transmitted/received Metal fixture that covers a slot for mounting Bus connection 4) Slot cover board. (should be removed when using Gateway function.) 1: The bending radius (R1: standard value) in the proximity of connector should be at least 4 times the external form of the cable.

4. Installation Procedure 4.1 When using the bus connection board (only when using Gateway function) How to mount the bus connection board is shown below. (1) Loosen the mounting screws (2 pcs.) that fix the slot cover on the back of the A9GT-J71E71-T. Slot cover Bus connection board (2) Remove the slot cover. Save the removed slot cover carefully. (If the A9GT-J71E71-T is used alone without the slot cover, foreign matter will enter the unit, causing a failure or malfunction.) (3) Fit the bus connection board to the A9GT-J71E71-T. (4) Tighten the mounting screws (2 pcs.) of the bus connection board to the specified torque (36 to 48N cm) to fix the bus connection board. (5) After fitting the bus connection board, mount the A9GT-J71E71-T to the GOT.

4.2 How to mount the A9GT-J71E71-T to the GOT. Mount the A9GT-J71E71-T to the GOT as follows; (1) Fit the communication module (2) securing fixtures in the GOT main unit. (1) (1) (1) (2) Mount the A9GT-J71E71-T on the GOT interface. (3) (3) Tighten and fix the mounting screws (3 pcs.) of the A9GT- J71E71-T in the specified torque range. (36 to 48N cm) (4) Connect the twisted pair cable to the A9GT-J71E71-T. (4) (5) To remove the unit, reverse the installation procedure. Point Grounding work for the 10BASE-T, 10BASE5 and 10BASE2 requires appropriate safety measures. Consult professionals for work details including terminal of connection cables and other plant work such as laying of main cables. Ethernet is a registered trademark of Xerox Corporation, U.S. Other business or product names mentioned herein are a trademark or registered trademark of each company.

Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties. For safe use This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life. Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi. This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system. Country/Region Sales office/tel U.S.A Mitsubishi Electric Automation Inc. 500 Corporate Woods Parkway Vernon Hills, IL 60061 Tel : +1-847-478-2100 Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. AV. Paulista 1471, Conj. 308, Sao Paulo City, Sao Paulo State, Brazil Tel : +55-11-283-2423 Germany Mitsubishi Electric Europe B.V. German Branch Gothaer Strasse 8 D-40880 Ratingen, GERMANY Tel : +49-2102-486-0 U.K Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, Hatfield, Herts., AL10 8XB,UK Tel : +44-1707-276100 Italy Mitsubishi Electric Europe B.V. Italian Branch Centro Dir. Colleoni, Pal. Perseo-Ingr.2 Via Paracelso 12, 20041 Agrate B., Milano, Italy Tel : +39-039-6053344 Spain Mitsubishi Electric Europe B.V. Spanish Branch Carretera de Rubi 76-80 08190 - Sant Cugat del Valles, Barcelona, Spain Tel : +34-93-565-3131 France Mitsubishi Electric Europe B.V. French Branch 25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France TEL: +33-1-5568-5568 South Africa Circuit Breaker Industries LTD. Tripswitch Drive, Elandsfontein Gauteng, South Africa Tel : +27-11-928-2000 Country/Region Sales office/tel Hong Kong Ryoden Automation Ltd. 10th Floor, Manulife Tower, 169 Electric Road, North Point, HongKong Tel : +852-2887-8870 China Ryoden Automation Shanghai Ltd. 3F Block5 Building Automation Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China Tel : +86-21-6475-3228 Taiwan Setsuyo Enterprise Co., Ltd. 6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, Taipei Hsine, Taiwan Tel : +886-2-2299-2499 Korea HAN NEUNG TECHNO CO.,LTD. 1F Dong Seo Game Channel Bldg., 660-11, Deungchon-dong Kangsec-ku, Seoul, Korea Tel : +82-2-3660-9552 Singapore Mitsubishi Electric Asia Pte, Ltd. 307 ALEXANDRA ROAD #05-01/02, MITSUBISHI ELECTRIC BUILDING SINGAPORE 159943 Tel : +65-6473-2308 Thailand F. A. Tech Co.,Ltd. 898/28,29,30 S.V.City Building,Office Tower 2,Floor 17-18 Rama 3 Road, Bangkpongpang, Yannawa, Bangkok 10120 Tel : +66-2-682-6522 Indonesia P.T. Autoteknindo SUMBER MAKMUR Jl. Muara Karang Selatan Block A Utara No.1 Kav. No.11 Kawasan Industri/ Pergudangan Jakarta - Utara 14440 Tel : +62-21-663-0833 India Messung Systems Put,Ltd. Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,PUNE-411026 Tel : +91-20-712-2807 Australia Mitsubishi Electric Australia Pty. Ltd. 348 Victoria Road, PostalBag, No 2, Rydalmere, N.S.W 2116, Australia Tel : +61-2-9684-7777 HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission. Specifications subject to change without notice. Printed in Japan on recycled paper.