C O N T R O L L E R I N F O R M A T I O N S H E E T. Siemens S7-300 Series (Ethernet)

Similar documents
Siemens S7-300 MPI. HMI Setting: Device Address: Supported Series: Siemens S7-300 series PLC Website:

Summary. Compatible PLCs. Communications Cable. PLC Settings. Gemini GV6 Series

C O N T R O L L E R I N F O R M A T I O N S H E E T. Allen-Bradley SLC500 & MicroLogix Series (DF1 BCC Checksum)

CONTROLLER INFORMATION SHEET

CONTROLLER INFORMATION SHEET

CONTROLLER INFORMATION SHEET

Allen-Bradley ONTROLLER NFORMATION HEET. MicroLogix 1000, 1100, 1200, Overview. Communications Cable. PLC Settings

CONTROLLER INFORMATION SHEET

T E C H N I C A L N O T E N/A

Siemens S7-200 PPI. HMI Setting: PLC Setting: Device Address:

Keyence KV Series ONTROLLER NFORMATION HEET. Overview. Communications Cable. PLC Settings

Idec ONTROLLER NFORMATION HEET. Micro 3 & OpenNet Series. Overview. Communications Cable

Mitsubishi FX Series ONTROLLER NFORMATION HEET. Overview. Communications Cable. PLC Settings

SIEMENS S7-200 PPI Direct

cmt Quick Start Guide

Animatics SmartMotor Series, RTC Series ONTROLLER NFORMATION HEET. Overview. Communications Cable

EasyBuilder Pro V Added [Scrolling control address] setting in Event Display object and Alarm

Compumotor. 6000, 6K & Germini Series (OITware)

1.1 Siemens S5/S7 Series

Siemens S7 MPI Driver PTC Inc. All Rights Reserved.

How to Use the TIA Portal to Set a Siemens PLC and the MGate 5103

Polling Data Registers from Siemens PLC Series S7-300, S7-400 & S7-1200

EZware Quick Start Guide

Low Cost Reliable Graphic OITs

An HMI for Every Application

*** If you have a Quick Designer project skip this section ***

Siemens S5 3964R Driver PTC Inc. All Rights Reserved.

Siemens S5 3964R Driver PTC Inc. All Rights Reserved.

Title: HMI500 Series Frequently Asked Questions

19.Configure HMI as a MODBUS Server

SIMATIC. S7 and Profibus- DP Configuration Guide G1026

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E09. PROFINET with 2x CPU 315F-2 PN/DP

Document: S7 Driver Configuration. Setting up the S7 driver to communicate with Siemens Hardware (S7-300/400 Series) using CP

Title: Using the AUX Port.

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

TIA Portal V11 Exercises

Siemens TCP/IP Unsolicited Ethernet Driver PTC Inc. All Rights Reserved.

Yaskawa Electric MP900 Series Driver

EasyAccess 2.0 Manual

P2 Configuration Guide

EZTouch Protocol Conversion Feature

Siemens TCP/IP Unsolicited Ethernet Driver PTC Inc. All Rights Reserved.

Allen-Bradley Micro800 Series

Import SIMATIC variables

EasyBuilder Pro V Fixed the problem where macro function FLOAT2ASCII may do incorrect

Siemens S7-200 Driver PTC Inc. All Rights Reserved.

Siemens S7 300 (Direct MPI)

EasyBuilder 8000 Version Build 2013/05/ Virtual com port and USB download drivers support Windows 7 64bit

Title: Using the AUX Port.

Title: Can I use Ethernet to read and write values to my HMI?

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE D3

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE B5 Structured programming with function blocks

Totally Integrated Automation (T I A) MODULE A3 Startup PLC- Programming with STEP 7

Ignition HMI interface to Fanuc Industrial Robots

Siemens S (symbolic addressing) (Ethernet)

Fisher ROC Plus Ethernet Driver Help Kepware, Inc.

General information. Supply voltage. Input current

General information. Supply voltage. Input current

SITRAIN. Introduction TIA Portal. Siemens AG All rights reserved. Unrestricted

Fisher ROC Plus Serial Driver Help Kepware, Inc.

Sample project Filling Station SIMATIC. STEP 7 Professional / WinCC Advanced V11 for Sample project Filling Station. Overview of the Getting.

General information. Supply voltage. Input current

Supply voltage. Input current. Encoder supply. Memory

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

Set HMI as a MODBUS Server

Version /09/17

General information. Supply voltage. Input current

Schneider Electric TSX07/37/57 Series Unitelway Driver

Please refer to application note AN00129 for further details on HCP2 configuration in ABB motion control products.

TECHNICAL NOTE TNOI30

MX-AOPC UA Server User s Manual

Weintek HMI to Control Techniques M400 AC Drive via Modbus TCP/IP Ethernet Module

Name List in Information Designer

1. By adding [MODBUS Server] with [Ethernet] interface, the [MODBUS TCP/IP. Gateway] feature can be enabled by selecting the [Enable] checkbox.

Idec Serial Driver Help Kepware Technologies

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE A7. Save / Archive / Program documentation

Yokogawa Application Note 4. The CPU Device Area Setup is now displayed. In the example below, no global memory has been allocated for use

GE Ethernet Global Data Driver Help Kepware Technologies

1. Added [Scroll bar] feature in [System Parameter Settings]» [Model] tab. This

cmt-g04 with OPC UA Server and MQTT Sparkplug B cmt-g04 with OPC UA Server and MQTT Sparkplug B

ROC Plus Communication Driver for JMobile

PLC COURSE LIST NMU TRAINING CENTRE

TIA Portal Workshop. Unrestricted. Siemens AG All rights reserved.

Content. Page 1 of 29

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

TECH NOTES-311. Integrating RACO Verbatim Gateway with the Allen-Bradley CompactLogix PLC via DH485

Fisher ROC Serial Driver Help Kepware Technologies

CPU 412H. Function. Parameterizable properties

cmt-g01 with OPC UA Server and Modbus Gateway

Electro-Craft IQ-Series Servo Controllers ONTROLLER NFORMATION HEET. Overview. Communications Cable. Controller Settings

How can you display error messages and warnings of a frequency converter on a panel? WinCC flexible RT and Panels FAQ

1 Application Description System Topology Hardware and Software Requirements About KingSCADA

APPLICATION NOTES. Advanced Graphical Interface - AGI Internal PLC (CODESYS V3) SHENDONG

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

SIMATIC S Update to the S System Manual, edition 03/2014 Product Information

Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE D5

Import Tool for PanelBuilder

Simatic S7 Ethernet driver for JMobile

MX-AOPC UA Server User s Manual

Transcription:

C O N T R O L L E R I N F O R M A T I O N S H E E T Maple Model(s) HMI5000 Series HMI5000P Series PLC or Controller Siemens S7-300 Series (Ethernet) Summary Maple Systems HMI5000 Series Human/Machine Interface Terminals (Maple HMIs) communicate with Siemens S7-300 Series PLCs using the PPI Ethernet protocol. When configured with EZware-5000, the Maple HMI is the master. Compatible PLCs Family S7-300 Series Model CPU 312, 313, 314, 315, 316, 317, 318, 319, CP 343 Ethernet Module ET-200S Communications Cable A list of communications cables offered by Maple Systems as well as cable assembly instructions to assist you in assembling your own communications cable are available on our website at www.maplesystems.com. WARNING If your communications cable is not wired exactly as shown in our cable assembly instructions, damage to the HMI or loss of communications can result. PLC Settings The IP Address must be set. Systems Inc., 808 134th Street SW, Suite 120, Everett, WA 98204-7333 www.maplesystems.com 1036-0132 Page 1 of 7 Rev. 05, 05/15/2012

Accessible PLC Memory Register Memory The following table lists the PLC s register memory ranges that the Maple HMIs are able to access. Please note that your PLC s memory range may be smaller or larger than that supported by these HMIs. The following register memory can be displayed in 16 or 32 bit format on the Maple HMI. (Note: d=decimal, f = file, o = octal) PLC Register Type Address Range Format PLC Register Description IW 0 to 4095 dddd Input Words (1) QW 0 to 4095 dddd Output Words (0) MW 0 to 4095 dddd Memory Word MD 0 to 4094 dddd Memory Double Word MB 0 to 4095 dddd Memory Byte DBBn 0 to 40969999 ffffdddd Data Register Byte DBn 0 to 40969999 ffffdddd DBDn 0 to 40969999 ffffdddd DBn_String 0 to 40969999 ffffdddd DBDn_String 0 to 40969999 ffffdddd DB0-DB99 0 to 655327 dddddo Data Register (Must be even) Data Register Double Word (Must be multiple of 4) Data Register String (Must be even) Data Register Double Word String (Must be multiple of 4) Data Register Words (Must be even) Discrete Memory The following table lists the PLC s discrete memory ranges that the Maple HMIs are able to access. Please note that your PLC s memory range may be smaller or larger than that supported by these HMIs. The following discrete memory is displayable in single-bit format on the Maple HMI. (Note: d=decimal o=octal) PLC Bit Type Address Range Format PLC Bit Description I 0 to 40957 ddddo Input (I) Q 0 to 40957 ddddo Output (O) M 0 to 40957 ddddo Bit memory DBnBit 0 to 4096655327 ffffddddo Data Register Bits DB0Bit ~ DB99Bit 0 to 65532 ddddo Data Register Bits Phone: 425/745-3229 Fax: 425/745-3429 Email: support@maplesystems.com www.maplesystems.com 1036-0132 Page 2 of 7 Rev. 05, 05/15/2012

Memory Not Supported The following PLC memory areas are not currently supported by the Maple HMIs: T (Timers) C (Counters) H (High Speed Counters) AI (Analog Inputs) SM (Special Memory) S (Status Memory) Important Memory Considerations If your PLC s memory range is smaller than the range supported by the Maple HMIs, it is possible to configure the HMI to monitor a PLC memory address which does not exist. Since this can cause unpredictable results, when you configure the HMI please ensure that all selected PLC memory addresses are valid for your PLC model. Do not configure the HMI to write to any PLC memory address which should only be written to by the PLC. Importing Tags Siemens STEP 7 programming software allows building files of user-defined tags (*.dif and *.AWL) and importing them into EasyBuilder-5000/EZwarePro using the Import Tag button in the System Parameter Settings > Device tab. Building a *.dif File 1. In STEP 7, create user-defined tags in the Symbol Editor (S7 Program > Symbols). Systems Inc., 808 134th Street SW, Suite 120, Everett, WA 98204-7333 1036-0132 Page 3 of 7 Rev. 05, 05/15/2012

2. Under Symbol Table, click Export to export the *.dif file, specify the file name, then click Save. Building a *.AWL File 1. In the Blocks folder, create DB items as shown below. 2. Open LAD, STL, FBD Programming S7 Blocks. Click File > Generate Source. 3. Select Sources as the storage path, specify the Object name, then click OK. Phone: 425/745-3229 Fax: 425/745-3429 Email: support@maplesystems.com www.maplesystems.com 1036-0132 Page 4 of 7 Rev. 05, 05/15/2012

4. Select the objects to be exported, then click OK. 5. The names of the saved files will be saved in the Sources folder. Select Export Source to build the *.AWL file. 6. The generated *.dif and *.AWL files can be imported into EasyBuilder- 5000/EZwarePlus by clicking the Import Tag button in the System Parameters Settings. Systems Inc., 808 134th Street SW, Suite 120, Everett, WA 98204-7333 1036-0132 Page 5 of 7 Rev. 05, 05/15/2012

7. When completed, the Import tag successful notification appears. Notes: The Tag Import function is available in EasyBuilder-5000 v4.60 and later, and in EZwarePlus v1.10 and later. EZware Settings The following table lists the communications settings that must be configured in EZware. These settings can be found in the Edit-Set System Parameters menu under the Device tab. Please note: The Recommended Settings column provides the recommended setting based upon the default settings most commonly used in the Siemens S7-300 PLC. The Options column lists EZware s options; your PLC may not support every option Name Name: HMI or PLC Recommended Settings Options Important Notes Siemens S7-300 (Ethernet) Description of Comm Port PLC Location Local Local, Remote Select local if PLC directly connected to HMI, remote if connected thru another HMI PLC type: Siemens S7-300 (Ethernet) PLC I/F: Ethernet Must match the controller port setting. PLC default station no.: 1 0-255 Must match the default station no. assigned to the PLC. Phone: 425/745-3229 Fax: 425/745-3429 Email: support@maplesystems.com www.maplesystems.com 1036-0132 Page 6 of 7 Rev. 05, 05/15/2012

Name Recommended Settings Options Important Notes Use UDP Unchecked Checked or Unchecked Must be Unchecked Settings: IP Address: XXX.XXX.XXX.XXX 0.0.0.0 255.255.255.255 Enter the IP Address of the PLC. Settings: Port 102 None This is the port address used by the Siemens PLC. Settings: Timeout (sec) 1.0 0.1 to 25.5 Adjust if longer timeout is required. Settings: Turn around delay (ms): 0 0-1000 Timeout period between HMI polls. Settings: Send ACK delay: 0 Not Applicable Settings: Parameter 1: 0 Not Applicable Settings: Parameter 2: 0 Not Applicable Settings: Parameter 3: 0 Not Applicable Interval of block pack words 5 0-512 See HMI5000 Series Programming Manual (Maple p/n 1010-1007) Max. read-command size (words): Max. write-command size (words): 32 Not Adjustable 32 Not Adjustable Online Simulator Broadcast Command Yes No Systems Inc., 808 134th Street SW, Suite 120, Everett, WA 98204-7333 1036-0132 Page 7 of 7 Rev. 05, 05/15/2012