More Info at Open Access Database

Similar documents
On the impact of probing form error on form measurement in Computed Tomography

Selection of items for InteraqCT Comparison on Assemblies

Frequency-based method to optimize the number of projections for industrial computed tomography

INVESTIGATION OF MEASURING STRATEGIES IN COMPUTED TOMOGRAPHY

Investigation on the influence of image quality in X-ray CT metrology

Creating a Multi-material Probing Error Test for the Acceptance Testing of Dimensional Computed Tomography Systems

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS

Parameter Dependent Thresholding for Dimensional X-ray Computed Tomography

Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

Evaluation strategies in CT scanning

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements

Investigation of the kinematic system of a 450 kv CT scanner and its influence on dimensional CT metrology applications

Use of reference objects for correction of measuring errors in X-ray computed tomography

CT for Industrial Metrology Accuracy and Structural Resolution of CT Dimensional Measurements

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

Creating a Multi-Material Length Measurement Error Test for the Acceptance Testing of Dimensional Computed Tomography Systems

Voxel dataset noise reduction algorithm based on CMM reference measurements for geometrical tolerance analysis of prismatic test pieces

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Experimental investigation of new multi-material gap reference standard for testing computed tomography systems

ASSESSMENT OF MEASUREMENT UNCERTAINTY CAUSED IN THE PREPARATION OF MEASUREMENTS USING COMPUTED TOMOGRAPHY

An initial experimental study on the influence of beam hardening in X-ray CT for dimensional metrology

Analysis of Combined Probing Measurement Error and Length Measurement Error Test for Acceptance Testing in Dimensional Computed Tomography

Industrial Computer Tomography for Dimensional Metrology: Overview of Influence Factors and Improvement Strategies

INFLUENCE OF GEOMETRICAL MAGNIFICATION ON COMPUTED TOMOGRAPHY DIMENSIONAL MEASUREMENTS

Efficient 3D Crease Point Extraction from 2D Crease Pixels of Sinogram

Coordinate Measuring Machines with Computed Tomography

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT

A cone-beam CT geometry correction method based on intentional misalignments to render the projection images correctable

Optiv CT160 Accurate measurement for every detail. Computed Tomography System

Experimental accuracy assessment of different measuring sensors on workpieces with varying properties

How beam hardening influences the dimensional geometry in X-ray computed tomography

Distance measurements on inaccessible wires in plastic parts with X-ray computed tomography

CT Measurement Realization Process: The Need for Advanced Correction Methods

Available online at ScienceDirect

Good Practice guide to measure roundness on roller machines and to estimate their uncertainty

Separation of CT Nominal-Actual Comparisons for Compensation of Plastic Injection Molds

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

Case Studies in the Use of Computed Tomography for Non-Destructive Testing, Inspection and Measurement

EMRP JRP IND62 TIM: Use of on-board metrology systems for area-scanning on machine tools

The Influence of Data Filtering on Dimensional Measurements with CT

The Virtual CMM a software tool for uncertainty evaluation practical application in an accredited calibration lab

Uncertainty Evaluation of Pore Analysis for Additively Manufactured Parts using Cross Sections

Quality control phantoms and protocol for a tomography system

Simulation-based correction of systematic errors for CT measurements

A new concept for high-speed atline and inline CT for up to 100% mass production process control allowing both 3D metrology and failure analysis

CT Systems and their standards

Investigating the volumetric performance of multi-axis measurement arms

INSPECTION OF THE TURBINE BLADES USING SCANNING TECHNIQUES

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

A universal method to optimise measurement uncertainty, time and cost for CMM scanning technology

Computer aided error analysis for a threedimensional precision surface mapping system

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

Case Studies in Nondestructive Testing and Evaluation

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques

AN EVALUATION OF NON-CONTACT LASER SCANNER PERFORMANCE USING CALIBRATED ARTIFACTS

Good practice guide for verification of area-scanning on-board metrology systems on machine tools

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

The new generation of industrial computed tomography. The Desktop CT exact S

Common aeronautic components. difficult to cut. Internal geometric features in aeronautic components. Properties of Nickel Alloys

Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation

Monte Carlo method to machine tool uncertainty evaluation

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Registration concepts for the just-in-time artefact correction by means of virtual computed tomography

University of Huddersfield Repository

Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies

X-ray Industrial Computed Laminography (ICL) Simulation Study of Planar Objects: Optimization of Laminographic Angle

A geometry measurement system for a dimensional cone-beam CT

Orbital forming of SKF's hub bearing units

Advanced Non-Destructive Testing by High Resolution Computed Tomography for 3D analysis of Automotive Components

Digital Volume Correlation for Materials Characterization

MULTIPLE-SENSOR INTEGRATION FOR EFFICIENT REVERSE ENGINEERING OF GEOMETRY

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape

Simulation Supported POD Methodology and Validation for Automated Eddy Current Procedures

Innovations in touch-trigger probe sensor technology

MCT225 HA Metrology CT

New Method for Master Pattern Tool Correction Based on Computed Tomography Data and Intelligent Reverse Engineering

Supplementary Materials for

Proposed new tests for evaluating CMM performance

X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection

Reducing the influence of environmental scattering in industrial computed tomography by system optimisation and correction algorithms

Introduction to XCT and its growth

doi: /

The PolyCT Increasing the sample throughput using multiple rotation axes

Using X-Ray Micro Tomography to assess the quality of Packaging Foil

Recognition and Measurement of Small Defects in ICT Testing

ADS40 Calibration & Verification Process. Udo Tempelmann*, Ludger Hinsken**, Utz Recke*

Impact of 3D Laser Data Resolution and Accuracy on Pipeline Dents Strain Analysis

pre- & post-processing f o r p o w e r t r a i n

Comparision of contact and contactless measuring methods for form evaluation

Form evaluation algorithms in coordinate metrology

Ultrasonic Multi-Skip Tomography for Pipe Inspection

Experimental study on performance verification tests for coordinate measuring systems with optical distance sensors

Process Monitoring using Three Dimensional Computed Tomography and Automatic Image Processing

COMPARISON OF ERROR MAPPING TECHNIQUES FOR COORDINATE MEASURING MACHINES USING THE PLATE METHOD AND LASER TRACER TECHNIQUE

Industrial Computed Tomography Innovations

Applying Hounsfield unit density calibration in SkyScan CT-analyser

Transcription:

More Info at Open Access Database www.ndt.net/?id=18750 Abstract Enhancing the Accuracy of Computed Tomography Measurements using Data Filtering Alessandro Stolfi a, Maarja-Helena Kallasse b, Lorenzo Carli b, Leonardo De Chiffre a a Technical University of Denmark, Produktionstorvet Building 425 Room 2092800 Kgs. Lyngby Denmark, email: alesto@mek.dtu.dk, ldch@mek.dtu.dk b Novo Nordisk A/S, Hillerød, 3400, Denmark email: mjhk@novonordisk.com email: lzcl@novonordisk.com This paper describes the impact of data filtering on CT capability to inspect assemblies. The investigation was carried out using an industrial multi-material assembly provided by Novo Nordisk A/S. The assembly comprises two parts made of polyoxymethylene (POM) and of an alloy comprising polycarbonate (PC) and acrylonitrile butadiene styrene (ABS), respectively. 3D median filters with different window sizes were taken in account as influence factors, while a variety of dimensional and geometrical tolerances were used as evaluation parameters. All measurands were calibrated using a tactile CMM with uncertainty below 7 µm. Keywords: Computed tomography, dimensional metrology, multi-material measurements, INTERAQCT Marie Curie, data filtering, polymers. 1 Introduction Computed Tomography (CT) represents a profound change in dimensional metrology. CT allows the inner and the outer geometry of an object to be measured without the need of external access or destructive testing [1-3]. CT provides a favourable information-to-measurement-time ratio making it possible to perform a large variety of dimensional inspections by using a data set only. These are just a few of the significant advantages with respect to coordinate measuring machines (CMMs) that are heading increasingly towards the establishment of CT in manufacturing industries dealing with free form and soft parts as well as assemblies. Despite the promising industrial adoption, a lot remains to be done on both the hardware and software side to enhance accuracy and precision of CT measurements. Data filtering may represent a great support tool enhancing the CT measurement accuracy minimising the unwanted signal affecting surface determination and feature fitting. This study evaluates features of 3D median filtering with respect to two variables such as the application stage of filtering within the CT measurement workflow and the kernel size. A multi-material item, including a mix of measurands was selected to explore filtering on a broader front. 2 Test workpiece and its calibration The Workpiece is an assembly component from a commercial insulin injection device from Novo Nordisk A/S (Figure ). The inner component is made of polyoxymethylene (POM). The outer component is made out a mixture of polycarbonate (PC) and acrylonitrile butadiene styrene (ABS). Both are produced using injection molding. Three measurands were selected on the outer part, as shown in a section view in Figure 1b. D1 represents the inner of the smallest cylindrical feature measured at z 3 mm from the datum B. R1 is roundness of D1. L2 represents the distance between the datum B and a plane on the bottom of the largest cylinder. Likewise, three measurands were selected on the outer part, as shown in a section view in Figure 1c. D3 represents the inner diameter of the smallest cylindrical feature measured at z -5 mm above the datum A, while R3 represents the roundness of D3. L4 is the distance between the datum B and a plane on the bottom flange. The similarity of measurands was chosen to adequately compare the effect of filtering on both components. Reference measurements were performed using a tactile CMM equipped with a probe with a diameter of 1.5 mm and 0.8 mm for the outer and inner component, respectively. A number of points ranging from 16 to 20 were probed and subsequently fitted using a least square routine. Measurement uncertainties below 7 µm were obtained for both components. www.3dct.at 1

(a) (b) Figure 1: (a) two-part component of an insulin pen and 2D definition of measurands for (b) outer and (c) inner component. (c) 3 Experimental plan Experimental test plan is schematically shown in figure 2. After scanning and reconstructing the stack of x-ray projections, the CT volume model was elaborated using three different workflows: two 3D filtered workflows and one unfiltered workflow, which was only used as a reference throughout the elaborations. The filtered workflows were performed similarly, the only exception being the stage in which the filter was applied, namely before performing surface determination (hereafter B-SD ) or after the latter (hereafter A-SD ). Two 3D median filters, characterized by two symmetrical kernels of 3 (hereafter Small kernel ) and 5 (hereafter Big kernel ) voxels were investigated because they provide a good noise removal and image segmentation enhancement. Moreover, 3D filters are definetely ease of use compared to 2D filtering requiring software and routines to be performed. The data sets were analysed using VG Studio Max 2.2.6. The surface determination was based on a local adaptive thresholding method (with a search distance of 5 voxels) in which the starting point was selected per data set independently of the other ones. This is necessary to record any change in the histogram of grey values. CMM and CT alignment and evaluations were performed alike, despite having modified the number of points to take full advantage of high density information featuring a CT measurement. All primitive features were least-squares fitted using 500 points (step width of 0.050 mm and seach distance of 0.1 mm). The evaluations of geometrical measurands were conducted taking into account the whole distribution of fitted points. The reason for that was not to introduce additional filtering during the evaluations. www.3dct.at 2

Parameter Unit Value Parameter Unit Value X-ray tube voltage X-ray tube current KV 100 Magnification 7 µa 270 No. of projections 1500 Voxel size µm 40 Integration time ms 1500 Spot size µm 23 No. of images for projection Table 1 Overview of the scanning parameters used. 1 Figure 2 Schematic representation of the experimental test plan. 4 Measuring setup for tactile and CT measurements A Nikon XT H 225 CT systems was used for the investigation and set according to table 1. The workpiece was scanned 3 times, placed within a low-absorption fixture. A fast shading correction together with a limited number of projections with no averaging were used to have a noise level being acceptable for the purpose of the investigation. The cabinet temperature was logged, found to be 23 ± 0.5 C, and assumed to correspond to the workpiece one due to the acclimation of a few hours before scanning. The reconstruction was performed on the CT Pro software package provided by Nikon Metrology, while the evaluations were conducted on the voxel-based data sets using VG Studio MAX 2.2.6 inspection software. During the reconstruction a beam hardening correction, based on 2nd order function was applied. The data sets were reconstructed as 32- bit floating point numbers rather than 16-bit integers to have their grey value distributions always comparable at a cost of larger data sets. Since the CT used is not a metrology-designed system, voxel size and temperature must be corrected. The voxel size correction was conducted using a ball-plate [4], as reference artefact, that was scanned twice (at the beginning and the end of three CT scans) in order to also consider the X-ray source drift, as the system ran for approximately 8 hours, including shading correction. The mean scaling factor value was found to be 0.9988, and taken directly into account rescaling the volume in VG studio Max. The correction was based on a few of 300 centre-to-centre distances available in the artefact due to the high magnification used. The correction of thermal deformation was carried out on Solidworks, using an isotropic model to simulate the workpiece, and subsequently taken into account for the dimensional measurands only. Additionally, the temperature did not affect the dimensional stability of workpiece, as negligible deformation in the contact zone between the components took place.the uncertainty assessment was based on the PUMA method (ISO 14253-2) [5], as described in equation 1. U cal D =k u 2 cal +u 2 2 p +u t (1) where k is the coverage factor, having a level of confidence of approximately 95 %; u cal is standard uncertainty establishing traceability using CMM measurements at σ-confidence level; u p is standard uncertainty describing the measurement procedure for each measurand, calculated as up = s is standard deviation from the reproduced measurements, u t is temperature-related standard uncertainty calculated for a deviation of ±0.5 C and using a coefficient of linear expansion for both components. No uncertainty contribution associated w-+ith the alignment was taken into account because an accurate alignment procedure, based on a best fit, followed by fine-tune alignment was used. Measurement uncertainties are reported per workflow and kernel size in table 2. Measurement uncertainties for length measurement are the greatest ones because the higher sensitivity to surface outliers and to datum system. Repeatability better of 2 µm was registered for majority the measurands due to the robust measurands used, to the efficacy of systematic error corrections performed but also to the absence of repositioning of the item during scanning. It can be observed in the table that the uncertainties for both components lie within the same range. This can be explained by the absence of beam hardening that usually characterizes the scanning of polymer parts. www.3dct.at 3

Component Measurand Unfiltered A-SD (small A-SD (Big B-SD (small B-SD (Big kernel) kernel) kernel) kernel) D1 12 12 12 12 12 Outer R1 12 13 12 12 12 L2 21 20 20 20 20 D3 14 14 14 15 15 Inner R3 12 12 13 13 12 L4 21 20 19 20 20 Table 2 Expanded uncertainties at 95% confidence level for the measurands of the two parts. Values in µm. Component Measurand Unfiltered A-SD (small A-SD (Big B-SD (small B-SD (Big kernel) kernel) kernel) kernel) D1 0.55 0.42 0.40 0.50 0.56 Outer R1 0.80 0.66 0.66 0.58 0.53 L2 0.15 0.15 0.19 0.35 0.36 D3 0.55 0.42 0.42 0.50 0.52 Inner R3 0.83 0.66 0.66 0.58 0.55 L4 0.25 0.25 0.24 0.40 0.50 Table 3 En values for the measurands of the two parts. 5 Results and discussion Results are presented in table 3 using the En criterion which considers deviations for reference quantities and measurement uncertainties simultaneously [6]. In this case, being measurement uncertainties rather constant (see table 2), En values represent deviations. The table shows that generally filtering decreases En values for both components and their measurands. The reduction of En values does not appear to be constant but varies as workflow and kernel size changes. A-SD workflow yielded better En values up to 22% for dimensional measurements independently of kernel size, while B-SD outperformed for geometrical measurements with a reduction of En of approximately of 28%. These results obtained emphasize the substantial difference between the workflows. In the A-SD, filtering is applied on a constrained data set and therefore it can just remove small structures on the surface similarly to a morphological operator such as closing and opening. Filtering within B-SD instead operates on a non-constrained data set and consequently produces a strong flattening by expanding of the data set, as shown in figure 4. Such an expansion resulted in deviations up to 7 µm for Big kernel with respect to the unfiltered data sets. This effect appeared not to be similar for any surface but changes with the noise level characterizing surfaces. (a) (b) Figure 4 Colour deviation maps showing dimensional differences with respect to the unfiltered volume for (a) A-SD and (b) B- SD workflow, which were filtered using Small kernel. In A-SD, the two kernel provided results were in very good agreement for diameter and roundness measurements as well as for length measurements. Larger differences were observed for B-SD due to the mentioned expansion of the data sets. Moreover, the two kernels modified asymmetrically the histogram of the residual of fitted points by mainly removing peaks. Negligible differences were noted with respect to the computation time between the workflows in processing the same kernel. Substantial differences were recorded for the computation time. Big kernel took 6 times longer than Small kernel to be completed. Image analysis showed that both workflows yielded a similar reduction of the noise of about 30 % with respect to the unfiltered www.3dct.at 4

workflow. Such a value was quantified using several x-ray slices taken in the XY plane of the CT coordinate system by mean of Fiji imaging analysis software. Imperceptible differences in the shape and extension of the distributions of grey values were observed with respect to the unfiltered one. This was also confirmed by the constancy of the optimal starting point value during surface determination throughout the tests. Furthermore, it was observed that increasing the filtering kernel improves the shape of the edge and the plateau, too (see figure 5). Despite the mentioned results, the differences between the two workflows were not sufficient to reject the null hypothesis of pair t-tests [7] performed for each kernel and for each measurand. The same conclusion was obtained for the kernel sizes. It may be concluded that inverting the filtering stage within the CT workflow or changing the kernel size has no significant effect on the accuracy. no filtering Small kernel Big kernel Figure 5 Profile across the edge before and after filtering the data set. Increasing filtering reduces the oscillating signal and makes edges sharper. 6 Conclusions This study evaluates features of 3D median filtering with respect to two variables such as the application stage of filtering within the CT measurement workflow and the kernel size. The following conclusions can be provided: The uncertainties of the CT measurements were found to vary between 12 and 20 µm depending on the measurands, and a repeatability better of 2 µm was quantified for all the measurands. Both components showed similar uncertainties and bias that support the absence of beam hardening. Filtering decreases En values for both components and their measurands. The accuracy enhancement does not appear to be constant but varies as workflow and kernel size changes. A-SD workflow yielded better En values up to 22% for dimensional measurements regardless of kernel size, while B-SD outperformed for geometrical measurements with a reduction of En of approximately of 28%. A mean noise reduction of approximately 30% was observed similarly for the filtered workflow compared to the unfiltered one. The two kernel within the A-SD workflow provided results were in very good agreement for diameter and roundness measurements as well as for length measurements. Slightly larger differences were observed for B-SD due to the allowed expansion of the data sets. Moreover, the two kernels modified asymmetrically the histogram of the residual of fitted points by mainly removing peaks. Acknowledgements The research leading to these results has received funding from the People Programme (Marie Curie Actions) of the European Union's Seventh Framework Programme (FP7/2007-2013) under REA grant agreement no. 607817 INTERAQCT. The authors would like to acknowledge Jakob Rasmussen in connection with the CMM measurements. References [1] J.-P. Kruth, M. Bartscher, S. Carmignato, R. Schmitt, L. De Chiffre, A. Weckenmann, Computed tomography for dimensional metrology, CIRP Ann. Manuf. Technol. 60, 821 842 (2011). [2] L. De Chiffre, S. Carmignato, J.-P. Kruth, R. Schmitt, A. Weckenmann, Industrial applications of computed tomography. CIRP Annals - Manufacturing Technology, 63(2), 655-677 (2014). [3] M. Bartscher, U. Hilpert, J. Goebbels, G. Weidemann, Enhancement and proof of accuracy of industrial computed tomography (CT) measurements, CIRP Ann. Manuf. Technol. 56, 495 498 (2007). [4] P. Müller, J. Hiller, A. Cantatore, G. Tosello, L. De De Chiffre, New reference object for metrological performance testing of industrial CT systems, Proceedings of the 12th International Conference of the European Society for Precision Engineering and Nanotechnology (euspen) 1(2012) pp. 72-75, ISBN13 978-0-9566790-0-0. [5] ISO 14253-2: 2011 Geometrical product specifications (GPS) Inspection by measurement of workpieces and measuring www.3dct.at 5

equipment Part 2: Guidance for the estima- tion of uncertainty in GPS measurement, in calibration of measuring equipment and in product verification. [6] ISO/IEC-17043. Conformity assessment, General requirements for proficiency testing. 2010. [7] Johnson, R. A. Probability and statistics for engineers. Miller & Freund s, Seventh Edition, 2005. ISBN 0-13-143745-3. www.3dct.at 6