FL SWITCH LM 8TX(-E) FL SWITCH LM 4TX/2FX(-E) FL SWITCH LM 4TX/2FX SM(-E)

Similar documents
PHOENIX CONTACT - 10/2009

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

PHOENIX CONTACT - 06/2006

PHOENIX CONTACT - 02/2007

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C

FL MC 2000E (SM40) LC

PHOENIX CONTACT - 11/2008

FL SWITCH Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings. Data sheet.

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

PHOENIX CONTACT - 07/2006

FL SWITCH 8TX. Extract from the online catalog. Discontinued item. Order No.:

onlinecomponents.com

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

Industrial Switches Industrial Switches

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

TRIO-DIODE/12-24DC/2X10/1X20

PHOENIX CONTACT - 04/2008

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342

Industrial Managed Ethernet Switch

AXL BK PN (-ME) Axioline bus coupler for PROFINET IO. Data sheet. 1 Description

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

PHOENIX CONTACT - 01/2007

IBS IL 24 RB-LK-2MBD:

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

SWITCH MM HS FL SWITCH MCS...

Industrial Gigabit Managed Ethernet Switch

QUINT-BUFFER/24DC/24DC/40

onlinecomponents.com

PHOENIX CONTACT - 05/2007

FL MC 10/100BASE-T/FO-660

AUTOMATION. User manual UM EN FL SWITCH LM. Order No.: Hardware and software for Lean Managed Switches

PHOENIX CONTACT - 07/2005

Industrial Switches. Industrial switches. Copper cables Fiber optic cables Ring redundancy

MINI MCR-SL-PT100-UI(-SP)(-NC)

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

FL MC EF 1300 SM SC. FO converter with SC duplex fiber optic connection (1300 nm), for converting 10/100Base-T(X) to single-mode fiberglass (9/125 μm)

Industrial Ethernet Switch

MINI MCR-SL-UI-2I(-SP)(-NC)

AXL E IOL AO1 U M12 R

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

MINI-PS AC/10-15DC/8

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

Hardened PoE Ethernet Switch

Valueline Industrial PC

AXL F BK PN. Axioline F bus coupler for PROFINET. Data sheet. 1 Description

STEP-PS/1AC/24DC/1.75

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

User manual Order No.

ILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

VERSAMAX IP PROFINET SCANNER. 1 Description. GFK-2760 June 2012

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS-3x AC/24DC/10

HARTING Ha-VIS mcon 3000 Next Generation Full managed Ethernet PROFINET Switch

PSI-MOS-RS422/FO 850 T

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Industrial 3-Port Fast Ethernet Media Converter Switches

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

PSI-MODEM-SHDSL/SERIAL

Stride Industrial Ethernet Switches

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

IBS PCI SC/I-T. Controller Board for PC Systems With PCI Bus. Data Sheet 6039B

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

IMC-21 Quick Installation Guide

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PSI-MOS-PROFIB/FO 850 T

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

FL MC EF 1300 MM ST. FO converter with B-FOC (ST ) connection (1300 nm), for converting 10/100Base-T(X) to multi-mode fiberglass (50/125 µm)

FL MC EF WDM... Ethernet FO converter for bidirectional data transmission via a single optical fiber (SC simplex) Data sheet.

Ha-VIS mcon 3000 Next Generation Introduction and features

PHOENIX CONTACT - 12/2007

Hardened Media Converter

PI-EX-ME-2NAM/COC-24VDC

IB IL 24 DI 16 IB IL 24 DI 16-PAC

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

IB IL 24/48 DOR 2/W-XC-PAC

PHOENIX CONTACT Features

GFK-2415A March Type of sensor connection

MINI MCR-SL-UI-REL(-SP)

QUINT-PS/ 1AC/24DC/ 5

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

Quick Start Guide. Physical Description.

Industrial Media Converters

MOXA Industrial Media Converter

PI-EX-ME-2NAM/COC-120VAC

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Transcription:

FL SWITCH LM 8TX(-E) FL SWITCH LM 4TX/2FX(-E) FL SWITCH LM 4TX/2FX SM(-E) Lean Managed Switches With Six or Eight Ports AUTOMATIONWORX Data Sheet 799_en_0 PHOENIX CONTACT - 06/2007 Description Lean Managed Switch The lean managed switches enable the cost-effective creation of manageable Ethernet networks in industrial environments. The compact ME45 switches are available as a 0/00 twisted pair version with eight ports. Alternatively, Phoenix Contact offers two versions with two glass fiber interfaces (00Base-FX multi mode or 00Base- FX single mode) and four twisted pair ports. All twisted pair ports have an auto negotiation and auto crossing function. Redundant and manufacturer-independent network structures are possible via Rapid Spanning Tree IEEE 802.w. Lean managed switches support complete network management via SNMP and have an integrated web server for comprehensive configuration and diagnostic mechanisms. The group of lean managed switches comprises three devices with a different port number or different transmission media: FL SWITCH LM 8TX with eight RJ45 ports FL SWITCH LM 4TX/2FX with four RJ45 ports and two multi-mode fiber optic SC ports FL SWITCH LM 4TX/2FX SM with four RJ45 ports and two single-mode fiber optic SC ports Features 0/00 Mbps RJ45 ports with auto crossing and auto negotiation Glass fiber SC ports 00 Mbps (00BASE-FX, full duplex) in single mode or multi mode SNMP management (Simple Network Management Protocol) Integrated web server for configuration and diagnostics Easy-to-use status and diagnostic indicators Redundancy via Rapid Spanning Tree (IEEE 802.w) 24 V DC supply voltage, redundant Floating alarm contact V.24/RS 232 Communication interface IGMP snooping Application Establishing collision-free Ethernet networks (Switched Ethernet) in industrial environments Robust infrastructure for industrial applications (EMC, vibrations, temperature range) Management, protocols and functions are compatible to office standards - important for continuity in global company networks Simple startup, configuration, diagnostics using the "Factory Manager" software tool Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. By default upon delivery the IGMP Snooping function is activated for the E versions. It can be activated in the WBM for the other versions, if necessary. This data sheet is valid for the products listed on the following page:

Ordering Data Products Description Type Order No. Pcs./Pkt. Lean managed switch with eight RJ45 ports Lean managed switch with four RJ45 ports and two multi-mode SC ports Lean managed switch with four RJ45 ports and two single-mode SC ports FL SWITCH LM 8TX FL SWITCH LM 8TX-E FL SWITCH LM 4TX/2FX FL SWITCH LM 4TX/2FX-E FL SWITCH LM 4TX/2FX SM FL SWITCH LM 4TX/2FX SM-E 2832632 289466 2832658 289660 28996 289864 Accessories Description Type Order No. Pcs./Pkt. Security set for four RJ45 ports FL SEC PAC 4TX 2832865 4 Gray RJ45 connector set for linear cable FL PLUG RJ45 GR/2 2744856 2 Green RJ45 connector set for crossed cable FL PLUG RJ45 GN/2 274457 2 Universal end clamp E/NS 35 N 0800886 50 Assembly tool for RJ45 connector FL CRIMPTOOL 2744869 Startup/diagnostic software - Factory Manager FL SWT 283044 Network monitoring with HMI/SCADA systems FL SNMP OPC SERVER 283266 Patch box 8 x RJ45 CAT5e, pre-assembled, can be retrofitted FL PBX 8TX 2832496 Patch cable, CAT 5, pre-assembled, 0.3 m long FL CAT5 PATCH 0,3 2832250 0 Patch cable, CAT 5, pre-assembled, 0.5 m long FL CAT5 PATCH 0,5 2832263 0 Patch cable, CAT 5, pre-assembled,.0 m long FL CAT5 PATCH,0 2832276 0 Patch cable, CAT 5, pre-assembled,.5 m long FL CAT5 PATCH,5 283222 0 Patch cable, CAT 5, pre-assembled, 2.0 m long FL CAT5 PATCH 2,0 2832289 0 Patch cable, CAT 5, pre-assembled, 3.0 m long FL CAT5 PATCH 3,0 2832292 0 Patch cable, CAT 5, pre-assembled, 5.0 m long FL CAT5 PATCH 5,0 2832580 0 Patch cable, CAT 5, pre-assembled, 7.5 m long FL CAT5 PATCH 7,5 283266 0 Patch cable, CAT 5, pre-assembled, 0.0 m long FL CAT5 PATCH 0 2832629 0 Technical Data General Data Function Lean managed Ethernet/Fast Ethernet switch; conforms to standard IEEE 802.3 Switch principle Store and forward Address table For 023 MAC addresses SNMP Version and 2 Supported MIBs SNMPv2 MIB, RSTP MIB, and private SNMP objects from Phoenix Contact Housing dimensions (width x height x depth) 45 mm x 99 mm x 2 mm Permissible operating temperature -40 C to +70 C Permitted storage temperature -40 C to +85 C Degree of protection IP20, DIN 40050, IEC 60529 Class of protection Class 3 VDE 006; IEC 60536 Maximum humidity (operation) 30% to 95%, no condensation Maximum humidity (storage/transport) 30% to 95%, no condensation Air pressure (operation) 86 kpa to 08 kpa, 500 m above sea level Air pressure (operation) 66 kpa to 08 kpa, 3500 m above sea level Preferred mounting position Perpendicular to a standard DIN rail Connection to protective earth ground By snapping it on a grounded DIN rail / via COMBICON (optionally) Weight 40 g, typical 799_en_0 PHOENIX CONTACT 2

Power Supply Connection Nominal value Permissible ripple Permissible voltage range Current consumption at U S at a nominal value of Test voltage Protection against polarity reversal Power consumption Via COMBICON; maximum conductor cross section = 2.5 mm 2 24 V DC 3.6 V pp within the permissible voltage range 8.5 V DC to 30.5 V DC 250 ma, typical (8TX...); 400 ma, typical (4TX/2FX...) 500 V DC for one minute Present 6 W, typical (8TX...); 9,6 W typical (4TX/2FX...) Interfaces Ethernet interface in RJ45 format Number 8 or 4 Connection format 8-pos. RJ45 socket on the switch Connection medium Twisted pair cable with a conductor cross section of 0.4 mm 2 to 0.22 mm 2 Cable impedance 00 Ohm Transmission speed 0/00 Mbps Ethernet interface (SC) Number 0 or 2 Connection format SC duplex socket on the switch Wavelength 300 nm Laser protection Class according to DIN EN 60825-:200- Minimum transmission length, including 3 db system reserve, when using multi-mode Maximum transmission power multi-mode 6,4 km glass fiber with F-G 50/25 0,7 db/km F200 2,8 km glass fiber with F-G 50/25,6 db/km F800 km glass fiber with F-G 62,5/25 0,7 db/km F00 3,0 km glass fiber with F-G 62,5/25 2,6 db/km F -4 dbm Minimum transmission power multi-mode -20 dbm with 62,5/25 µm, -23,5 with 50/25 µm Minimum receiver sensitivity multi-mode -3 dbm Maximum overrange multi-mode Minimum transmission length, including 3 db system reserve, when using single-mode Maximum transmission power single-mode Minimum transmission power single-mode Minimum recierver sensitivity single-mode Maximum overrange single-mode -4 dbm 36 km glass fiber with F-G 9/25 0,36 db/km 32 km glass fiber with F-G 9/25 0,4 db/km 26 km glass fiber with F-G 9/25 0,5 db/km -8 dbm -5 dbm -3 dbm -7 dbm Transmission speed 00 Mbps V.24 (RS-232) communication interface Number Connection format Mini-DIN female connector on the switch Floating alarm contact Voltage 24 V DC Current carrying capacity 00 ma, maximum Mechanical Tests Shock test according to IEC 60068-2-27 Operation: 25g, ms period, half-sine shock pulse Storage/transport: 50g, ms period, half-sine shock pulse Vibration resistance according to IEC 60068-2-6 Operation/storage/transport: 5g, 50 Hz, criterion 3 Free fall according to IEC 60068-2-32 m 799_en_0 PHOENIX CONTACT 3

Conformance With EMC Directives Developed according to IEC 6000-6.2 Emitted interference acc. to EN55022: 998 + A: 2000 + A2: 2003 (interference voltage) Emitted interference acc. to EN550: 998 + A: 999 + A2: 2002 (electromagnetic interference) General Information Class A (industrial applications) Class A (industrial applications) Noise immunity acc. to EN6000-4-2 (IEC000-4-2) (ESD) Requirements acc. to DIN EN 6000-6-2 Contact discharge: Test intensity 2, criterion B Air discharge: Test intensity 3, criterion B Indirect discharge: Test intensity 2, criterion B Noise immunity acc. to EN6000-4-3 (IEC000-4-3) (electromagnetic fields) Requirements acc. to DIN EN 6000-6-2 Test intensity 3, criterion A Noise immunity acc. to EN6000-4-4 (IEC000-4-4) (burst) Requirements acc. to DIN EN 6000-6-2 Data lines: Test intensity 2, criterion B Voltage supply: Test intensity 3, criterion B Noise immunity acc. to EN6000-4-5 (IEC000-4-5) (surge) Requirements acc. to DIN EN 6000-6-2 Data lines: Test intensity 2, criterion B Voltage supply: Test intensity, criterion B Noise immunity acc. to EN6000-4-6 (IEC000-4-6) (conducted) Requirements acc. to DIN EN 6000-6-2 Test intensity 3, criterion A Warning Disregarding this warning may result in damage to equipment and/or serious personal injury. Only qualified personnel may start up and operate this device. According to the safety instructions in this text, qualified personnel are persons who are authorized to start up, to ground, and to mark devices, systems, and equipment according to the standards of safety technology. In addition, these persons must be familiar with all warning instructions and maintenance measures in this text. Warning The FL SWITCH LM... module is designed exclusively for SELV operation according to IEC 950/EN 60950/ VDE 0805. Installation and Mounting/Removal Install the lean managed switch on a clean DIN rail according to EN 6075. To avoid contact resistance only use clean, corrosion-free DIN rails. End clamps can be mounted on both sides of the module to stop the modules from slipping on the DIN rail. Mounting Place the module onto the DIN rail from above. The upper holding keyway of the module must be hooked onto the top edge of the DIN rail. 2 Push the module from the front towards the mounting surface. 3 Once the module has been snapped on properly, check that it is fixed securely on the DIN rail. Removal Pull the locking latch down using a screwdriver, needle-nose pliers or similar. 2 Pull the bottom edge of the module away from the mounting surface. 3 Pull the module diagonally upwards away from the DIN rail. 799_en_0 PHOENIX CONTACT 4

Terminal Assignment Connect the DIN rail to protective earth ground using a grounding terminal block. The modules are grounded when they are snapped onto the DIN rail. Connect protective earth ground with low impedance.! " # $ % & 7 5 $ # % $ Terminal Meaning Supply voltage +US 2 GND US 3 Supply voltage +US2 4 GND US2 5 and 6 Floating alarm contact 7 Functional earth ground (optional) 8 Not connected Figure Terminal Assignment Connection of the Supply Voltage Warning The product designation/brief product designation (-PAC) module is designed exclusively for SELV operation according to IEC 950/EN 60950/VDE 0805. Example Voltage Supply of the Module From One or Two Voltage Sources and Connection of the Alarm Contact opt. 2 opt. 24VDC 24VDC US US Figure 2 Example voltage supply of the module from one or two voltage sources and connection of the alarm contact Supplying the Module From One Voltage Source The 24 V supply voltage can be connected redundantly. Both voltage inputs are electrically isolated from one another and the housing. In the event of redundant voltage supplies the higher of the two voltages supplies the switch. The load is not distributed. The module is fully operational even with only one supply voltage (without jumpering it to other supply voltage terminal blocks). In the event of a non-redundant voltage supply the switch indicates a voltage supply failure by opening the alarm contact. This error message can be avoided by connecting the supply voltage to both terminals in parallel, as shown in Figure 2, or by deactivating redundant supply voltage monitoring in the web-based management. 799_en_0 PHOENIX CONTACT 5

Monitoring the Voltage Supply A message is generated via an SNMP trap if voltage is not present at the two supply voltage terminal blocks US and US2. The target address can be set in the web-based management. If the voltage is not supplied redundantly, terminal blocks US and US2 must be jumpered (see Figure 2, version ) in order for the voltage to be monitored via the SNMP trap. Option: In addition, noise immunity can be increased in environments subject to high EMI by a low-impedance connection to functional earth ground via terminal block 7. Connection to Functional Earth Ground Snapping the switch onto a grounded DIN rail connects it to the ground potential. The switch is designed for SELV operation according to IEC 950/EN 60950/VDE 0805. Only SELV according to the defined standards may be used for supply purposes. In case of a non-redundant voltage supply the switch indicates the voltage supply failure via the SNMP trap. This error message can be avoided by connecting the supply voltage to both terminals in parallel, as shown in Figure 2, version, or by deactivating redundant supply voltage monitoring in the web-based management. Local Diagnostic and Status Indicators US US2 US US2 6 2 8 7 2 5 3 4 6 5 3 4 FL SWITCH LM 4 TX2FX Ord. No.2832658 FL SWITCH 5 TX FL SWITCH LM 8 TX Ord. Ord. No.2832632 No.2832085 FL SWITCH LM 4TX/2FX FL SWITCH LM 4TX/2FX SM FL SWITCH LM 8TX Figure 3 Front view 799_en_0 PHOENIX CONTACT 6

Local Status and Diagnostic Indicators Des. Color Status Meaning US Green ON Supply voltage US in the tolerance zone OFF Supply voltage US less than 8 V DC US2 Green ON Supply voltage US2 in the tolerance zone OFF Supply voltage US2 less than 8 V DC RJ45 ports LNK Green ON Link active OFF Link not active Blink Sending/receiving telegrams 00 Yellow ON Full duplex mode OFF Half duplex mode Blink Collision detect FX ports LNK Green or ON Link active yellow OFF Link not active Blink Sending/receiving telegrams Assigning the IP address Two mechanisms are available for the assignment of the IP address: BootP or via the RS232 interface. By default upon delivery, the IP address is assigned via BootP. The Factory Manager configuration software has been optimized for use with the LMS and enables easiest IP address assignment. The assignment mechanism can be modified via the web-based management or via the RS232 interface. Hardware Functions "Store and forward Ethernet switching All data telegrams that are received by the switch are saved and checked for validity. Invalid or faulty data packets (>522 bytes or CRC errors) and fragments (<64 bytes) are rejected. Valid data telegrams are forwarded by the switch. The switch always forwards the data using the data transmission rate that is used in the target network segment. Multi-address function The switch automatically learns the addresses of the termination devices that are connected via a port by evaluating the source address in the data telegrams. Only packets with unknown addresses, with a source address of this port or with a multicast/broadcast address in the target address field are forwarded via the corresponding port. The switch can store up to 8000 addresses in its address table with an aging time of approximately 300 seconds. This is important when more than one termination device is connected to one or more ports. In this way, several independent subnetworks can be connected to one switch. Diagnostics via alarm contact Is one or both supply voltages missing, opens the alarm contact. On a restart, the switch executes a hardware selftest. In the event of an error during the selftest, an SNMP trap is transmitted. During operation, an integrated watchdog monitors the cyclic execution of the software program. If the watchdog is not cyclically triggered by the software, an SNMP trap is transmitted. 799_en_0 PHOENIX CONTACT 7

Status and diagnostic indicators These indicators will always keep you informed about the LMS status. Local diagnostics without additional tools is possible thanks to numerous LEDs. Auto crossing Thanks to auto crossing of the transmit and receive cables of a twisted pair interface, it is no longer necessary to differentiate between a : cable or a cross-over Ethernet cable. Auto negotiation Auto negotiation is a function whereby the switch automatically detects the operating parameters for the connected network and sets the corresponding parameters (0 Mbps/00 Mbps data transmission rate and half/full duplex transmission mode) for its RJ45 ports. Automatic port setting eliminates the need for manual intervention by the user. The auto negotiation function can be activated/deactivated via the web interface. Twisted pair The switch uses link test pulses according to standard IEEE 802.3 at regular intervals to monitor the connected TP/TX cable segments for short circuits and interrupts. Software Functions SNMP SNMP (Simple Network Management Protocol) enables Ethernet communication monitoring also via network management systems. Management systems, such as a PC with Factory Manager, can read and modify configuration and diagnostic data from network devices via SNMP. Supported MIBs: SNMP (MIB II, Bridge, IF MIB), Phoenix MIB, RSTP MIB. IEEE 802.w - Rapid Reconfiguration Spanning Tree Protocol (RSTP) Rapid Spanning Tree is a procedure enabling the use of redundant Ethernet structures. Via RSTP, the meshed topologies of the redundant structures are suppressed logically and acyclic converted to tree structures. In meshed networks, two nodes may be connected in two or more ways (loop). Due to these loops, data packets would circle endlessly in the network. For this reason these loops are replaced by a logical deterministic path using an RSTP algorithm. The loops are eliminated by temporarily switching off the individual switch ports in a controlled way. All active ports as well as deactivated ports receive data packets. However, the data packets are only forwarded by active ports. The deactivated ports operating in hot standby mode are reintegrated into the network, if required, by modifying the network topology. Web-Based Management Apart from the management via SNMP, the switch also supports integrated web-based management. This enables detailed ways for diagnostics and configuration during startup, operation and in the event of an error, as well as comprehensive network and device information. IGMP Snooping In IGMP snooping, the switch passively listens in on the IGMP messages that are sent over the network and dynamically creates the appropriate groups. The groups are not saved and will be lost on every power down or when switching off the snooping function. By default upon delivery the IGMP Snooping function is activated for the E versions. It can be activated in the WBM for the other versions, if necessary. 799_en_0 PHOENIX CONTACT 8

Functions/Information in Web-Based Management General Instructions General description of the web pages Device Information General Information about the device and manufacturer Technical data The most important technical data Hardware installation Figure showing how to connect the component Local diagnostics Explanations regarding the local status and diagnostic indicators Serial port List of transmission parameters for serial communication General Configuration IP configuration Indication or modification of the current IP parameters as well as of the addressing mechanism SNMP configuration Indication/modification of the customer-specific device description and the trap configuration Software update Indication or modification of the parameters for the TFTP software update Configuration management Specifications for saving the active configuration as well as the option to reset the switch to the default settings Change password Modification of the current password Other services Activation/deactivation of the SNMP agent, the web server or RSTP Ports Port table Activation/deactivation of individual ports Port configuration Individual configuration for every individual port Port statistics Detailed statistic information on the data volume of every individual port RSTP configuration and information RS232 Communication Interface for External Management General function A local communication connection for configuration purposes can be established between the LMS and a PC using the RS232 interface in Mini-DIN format. You can implement the following settings in the terminal interface: Assigning the IP address Assigning the subnet mask Determining the default gateway Activating/deactivating BootP "Save Parameters" request "Restart" request "Reset to Factory Defaults" request US GND US2 GND US US2 V.24 Switch Station Remote diagnostics Status of the alarm contact and the voltage supply MIB2 traps Configuration of the states that are to be reported via a trap Figure 4 FL SWITCH 8TX Ord.-No.283228 8 7 2 6 3 5 4 Position of the RS232 interface PHOENIX CONTACT 06/2007 799_en_0 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 9 Phone: +49-(0) 5235-3-00 Fax: +49-(0) 5235-3-4 2 00 www.phoenixcontact.com