XL7 OCS Datasheet for HE-XW1E0, HE-XW1E2, HE-XW1E3, HE-XW1E4, HE-XW1E5 HEXT391C100, HEXT391C112, HEXT391C113, HEXT391C114, HEXT391C115

Similar documents
Advanced Ladder Logic Required Power 24VDC. Full IEC Languages (Steady state) (heater duty cycle) 24VDC

XL4 OCS Datasheet for HE-XC1E0, HE-XC1E2, HE-XC1E3, HE-XC1E4, HE-XC1E5 HEXT251C100, HEXT251C112, HEXT251C113, HEXT251C114, HEXT251C115

Control & Logic Specifications Required Power 24 VDC (355mA with heater operating).

XL4 OCS DATASHEET MODEL DC In, 12 DC Out, 2 12-bit Analog In. Serial Ports. USB mini-b USB A. CAN Port Isolated 1 kv.

Digital Inputs 2048 Clock Accuracy +/- 20 ppm maximum at 25 C (+/- 1 min/month)

XL4 OCS DATASHEET MODEL DC In, 6 Relay Out, 4 12-bit Analog In. Serial Ports. USB mini-b USB A. CAN Port Isolated 1 kv. Gen.

Specifications / Installation. Specifications Digital DC Inputs XL103 XL104 Digital DC Outputs XL103 XL104

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

Specifications / Installation. QX Series Models:

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

QX751 CANOpen HEQX751C203/HEQX751C205 HE-BP41/HE-BP43 Back Pack Module

SmartRail I/O Ethernet Base HE599ETX300

DeviceNet Master (Scanner) HE800DNT450 / HE-DNT450* DeviceNet Communications * HE- denotes plastic case.

4-20 ma Analog Input Module HE800ADC020 / HE800ADC120 HE-ADC020* / HE-ADC120* 12-Bit Resolution * HE-denotes plastic case.

Thermistor / Current / Voltage Analog Input Module HE800ADC920 / HE-ADC920* 12-Bit Resolution * HE- denotes plastic case.

Thermocouple / Millivolt Input Module HE800THM000 / HE800THM100 HE-THM000 / HE-THM100* * HE- denotes plastic case.

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 4-20mA Analog In/Out HE800MIX902 / HE-MIX902* * HE- denotes plastic case.

RTD Input Module HE800RTD000 / HE800RTD100 HE-RTD000 / HE-RTD100* * HE- denotes plastic case.

Temperature I/O Module HE800MIX963 / HE-MIX963* * HE- denotes plastic case.

MAN October 2010 PAGE 1 HE-579ACM300 SmartBlock Power and Energy Monitor HE-579ACM300

PanelView Plus/VersaView CE Terminals and Display Modules

ALL-IN-ONE INTELLIGENT AND POWERFUL CONTROLS

ALL-IN-ONE INTELLIGENT AND POWERFUL CONTROLS

A Next Generation OCS. XL Series OCS

XL Series OCS. The industry leader in all-in-one control. All-in-one intelligent & powerful controls

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 0-20mA Sourcing Analog In/ Out HE800MIX906 / HE-MIX906* * HE- denotes plastic case.

HV-CS kv Edge Mount Triaxial Jack

Select Micro800 Plug-in Modules and Accessories

TM241CE24T controller M IO transistor PNP Ethernet

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

PACSystems RX3i IC695PSA140

PM Series Power Meter

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

4-20mA Analog Output Module HE800DAC002 / HE800DAC102 HE-DAC002* / HE-DAC102* 14-Bit Resolution * HE- denotes plastic case.

PanelView 600 Terminals

Programmable Logic Controllers Micro850

XL & RCC SERIES OCS ALL-IN-ONE INTELLIGENT AND POWERFUL CONTROLS

XBP24-E Base 24 I/O Ethernet PRELIMINARY. General characteristics Part number

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

TM241CE40R controller M IO relay Ethernet

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

TM241CE24U controller M IO transistor NPN Ethernet

TM241C40U controller M IO transistor NPN

V TU24 V350-J-TU24

Select a Micro800 Controller

TM241C24T controller M IO transistor PNP

HMISCU6B5. Main. 60 right 40 top 60 bottom

TM241CE24T controller M IO transistor PNP Ethernet

Logic Controller Millenium Evo

TM241CE40T controller M IO transistor PNP Ethernet

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

MAXIMA+ Series Rotary Level Indicator

DATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

TM241CE40R controller M IO relay Ethernet

Logic Controller Millenium Evo

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM241CE40R controller M IO relay Ethernet

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

OPLC Installation Guide

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

TM241C40R controller M IO relay

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

MAXIMA + Series ROTARY LEVEL CONTROL

Druck DPI 620 advanced modular calibrator

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

TM221M16TG controller M IO transistor PNP spring

24/48/120 VAC Interface Card Instruction Manual

TM221M32TK controller M IO transistor PNP

ViewPoint II Operator Interface

TM241CEC24R controller M IO relay Ethernet CAN master

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Discrete Output Modules

User Manual for EXL6 OCS

TM221CE40T controller M IO transistor PNP Ethernet

Installation, Operation and Maintenance Manual

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

F1000 User's Manual. (Version: V1.01)

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes* Yes* Yes* USB device, mini-b Com Ports, separate order, user-installed

EXPRESS SETUP. PanelMate 1700 Series PanelMate Power Pro. Cutler-Hammer

TM241CE24T controller M IO transistor PNP Ethernet

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

BCM2 Series Branch Circuit Monitors Quick Setup Guide

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

Installing and Configuring Rialto Analytic Appliances

TM221ME32TK controller M IO transistor PNP Ethernet

TC100 Precision Thermocouple Calibrator

Transcription:

XL7 OCS Datasheet for HE-XW1E0, HE-XW1E2, HE-XW1E3, HE-XW1E4, HE-XW1E5 HEXT391C100, HEXT391C112, HEXT391C113, HEXT391C114, HEXT391C115 Specifications/Installation 1. Specifications General Specifications Control & Logic Specifications Required Power Advanced Ladder Logic 170mA @ 24VDC Control Language Support (Steady state) Full IEC 1131-3 Languages Required Power (Inrush) 7A for <1 ms @ 24 VDC DC Switched Logic Program Size & Logic Scan Rate 1MB, maximum 0.013mS/K Primary Power Range 10 30VDC Online Supported in Advanced Ladder Programming Changes Relative Humidity 5 to 95% Non-condensing Digital Inputs 2048 Clock Accuracy +/- 20 ppm maximum at 25 C Digital Outputs 2048 I/O Support (+/- 1 Minutes per Month) Analog Inputs 512 Surrounding Air Temp -10 C to +60 C Analog Outputs 512 Storage Temp -30 C to +70 C 50,000 (words) Retentive Weight 2lb. (without I/O) General Purpose Registers 16,384 (bits) Retentive US Certifications UL / CE Europe Certifications Display Specifications 16,384 (bits) Non-retentive Connectivity Display Type 7 TFT Transmissive Color Serial Ports 1 RS-232 & 1 RS-485 on first Modular Jack (MJ1/2) 1 RS-232 or 1 RS-485 on second Modular Jack (MJ3) Resolution 800x480 USB mini-b USB 2.0 (480MHz) Programming & Data Access Color 16-bit (65,535) USB A USB 2.0 (480MHz) for USB FLASH Drives (2TB) Screen Memory 27 MB CAN Remote I/O, Peer-to-Peer Comms, Cscape User-Programmable Screens 1023 Ethernet 10/100 Mb (Auto-MDX), Modbus TCP C/S, HTTP, FTP, SMTP, Cscape, Ethernet IP Backlight LED 50,000 hour life Remote I/O SmartRail, SmartStix, SmartBlock, SmartMod Screen Update Rate User Configurable within the scan time. MicroSD, support for 32GB max. Removable Memory (perceived as instantaneous in many cases) Application Updates, Datalogging, more Input / Output Specifications Model DC In DC Out Relays HS In HS Out ma/v In ma/v ma/v High-Speed Counters RTD/Tc Out Number of Counters 2 Model 2 12 6 4 4 Maximum Frequency 500 khz each Model 3 12 12 4 2 2 Accumulator Size 32-bits each Model 4 24 16 4 2 2 Modes Supported Model 5 12 12 4 2 2 2 Totalizer Quadrature There are 4 high-speed inputs of the total DC Inputs. There are 2 high-speed outputs of the total DC Pulse Measurement Frequency Measurement outputs. Model 2, 3 & 4 feature 12-bit Analog I/O. Model 5 features 14/16-bit Analog I/O. High-speed Outputs can be used for PWM and Pulse Train Outputs, currently limited to <65kHz. 2 Position Controlled Outputs 1 ON/OFF Setpoint per Output 2. Dimensions & Panel Cutout Cutout tolerance to meet NEMA standards is ±0.005 (0.1mm). Max. Panel Thickness is 5mm. Page 1 of 7

3. Installation Procedures 1. Carefully locate an appropriate place to mount the XL7. Be sure to leave enough room at the top of the unit for insertion and removal of the microsd card. Also leave enough room at the bottom for the insertion and removal of USB FLASH drives 2. Carefully cut the host panel per the diagram on Page 1, creating a 189.7mm x 131.2mm ±0.1mm opening into which the XL7 may be installed. If the opening is too large, water may leak into the enclosure, potentially damaging the XL7. If the opening is too small, the OCS may not fit through the hole without damage. 3. Remove all Removable Terminals from the XL7. Insert the XL7 through the panel cutout (from the front). The gasket needs to be between the host panel and the XL7. 4. Install and tighten the four mounting clips (provided in the box) until the gasket forms a tight seal (max torque 7-10 lb-in. [0.8 1.13 Nm]) 5. Reinstall the XL7 I/O Removable Terminal Blocks. Connect communications cables to the serial port, USB ports, Ethernet port, and CAN port as required. 4. Ports & Connectors Page 2 of 7

Page 3 of 7

5. Safety WARNING: Only qualified electrical personnel familiar with the construction and operation of this equipment and the hazards involved should install, adjust, operate, or service this equipment. Read and understand this manual and other applicable manuals in their entirety before proceeding. Failure to observe this precaution could result in severe bodily injury or loss of life. WARNING: To avoid the risk of electric shock or burns, always connect the earth ground before making any other connections. WARNING: To reduce the risk of fire, electrical shock, or physical injury it is strongly recommended to fuse all Power Sources connected to the OCS. Be sure to locate fuses as close to the source as possible. WARNING: Replace fuse with the same type and rating to provide protection against risk of fire and shock hazards. WARNING: In the event of repeated failure, do not replace the fuse again as a repeated failure indicates a defective condition that will not clear by replacing the fuse. WARNING: Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fire. WARNING: EXPLOSION HAZARD BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NON-HAZARDOUS Power input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods of the National Electric Code, NFPA 70 for installations in the U.S., or as specified in Section 18-1J2 of the Canadian Electrical Code for installations within Canada and in accordance with the authority having jurisdiction. This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or Non-hazardous locations only. WARNING: EXPLOSION HAZARD Do not disconnect equipment unless power has been switched off or the area is known to be nonhazardous. WARNING: EXPLOSION HAZARD Substitution of components may impair suitability for Class 1, Division 2. Digital outputs shall be supplied from the same source as the Operator Control Station. Jumpers on connector JP1 and others shall not be removed or replaced while the circuit is live unless the area is known to be free of ignitable concentrations of flammable gasses or vapors. 6. Common Cause of Analog Input Tranzorb Failure A common cause of Analog Input Tranzorb Failure on Analog Inputs Model 2, 3, 4 & 5: If a 4-20mA circuit is initially wired with loop power, but without a load, the Analog input could see 24Vdc. This is higher than the rating of the tranzorb. This can be solved by NOT connecting loop power prior to load connection, or by installing a lowcost PTC in series between the load and Analog input. See SUP0977-01 for additional details. NOTE : Refers to Model 2 orange (pg.5,) Models 3 & 4 J1 (pg.6) and Model 5 20mA Analog In (pg.7.) 7. Technical Support For assistance and manual updates, contact Technical Support at the following locations: North America (317) 916-4274 Toll Free: 877-665-5666 http://www.heapg.com e-mail: techsppt@heapg.com Europe (+) 353-21-4321-266 http://www.horner-apg.com e-mail: tech.support@horner-apg.com Page 4 of 7

8. Built-in I/O (Model 2, 3, 4 & 5) All XL7 models (except the HE-XW1E0) feature built-in I/O. The I/O is mapped into OCS Register space, in three separate areas Digital/Analog I/O, High-Speed Counter I/O, and High-speed Output I/O. Digital/Analog I/O location is fixed starting at 1, but the Highspeed Counter and High-speed Output references may be mapped to any open register location. For more details on using the High- Speed Counter and High-Speed Outputs, see the XL7 OCS User s Manual (MAN0974-01). Model 2 I/O The XL7 model 2 (HE-XW1E2) features 12 DC Inputs, 6 Relay outputs, and 4 Analog Inputs. The DC Inputs are 12/24Vdc compatible, and can be jumpered for Positive Logic (sinking), or Negative Logic (sourcing). Two of the inputs (H1-H2) can be used for high-speed functions up to 500kHz. The 12-bit Analog Inputs can be jumpered for voltage (0-10V) or current (4-20mA) on a channel by channel basis. The Relay outputs are isolated, supporting AC and DC voltages, with output currents of up to 3A/relay, 5A total. Page 5 of 7

Model 3 & 4 I/O The XL7 model 3 (HE-XW1E3) features 12 DC Inputs, 12 DC outputs, and 2 Analog Inputs. The XL7 model 4 (HE-XW1E4) increases the I/O count up to 24 DC Inputs, and 16 DC Outputs and 2 Analog Inputs. The DC Inputs are 12/24Vdc compatible, and can be jumpered for Positive Logic (sinking), or Negative Logic (sourcing). Two of the inputs (H1-H2) can be used for high-speed functions up to 500kHz. The 12-bit Analog Inputs can be jumpered for voltage (0-10V) or current (4-20mA) on a channel by channel basis. The 12/24VDC Outputs feature Electronic Short Circuit protection, and support currents up to 0.5A per point, and 4A total. Two of the DC Outputs can be used for high speed functions (PWM or PTO). The output frequency is limited by the switching capability of the output drivers (about 10kHz), although an optional accessory (HE-XHSQ) can be added to provide parallel output drivers supporting frequencies up to 200kHz. Page 6 of 7

Model 5 I/O The XL7 model 5 (HE-XW1E5) features 12 DC Inputs, 12 DC outputs, with high performance, highly configurable Analog Inputs (2) and Analog Outputs (2)., The DC Inputs are 12/24Vdc compatible, and can be jumpered for Positive Logic (sinking), or Negative Logic (sourcing). Two of the inputs (H1-H2) can be used for high-speed functions up to 500kHz. The 12/24VDC Outputs feature Electronic Short Circuit protection, and support currents up to 0.5A per point, and 4A total. Two of the DC Outputs can be used for high speed functions (PWM or PTO). The output frequency is limited by the switching capability of the output drivers (about 10kHz), although an optional accessory (HE-XHSQ) can be added to provide parallel output drivers supporting frequencies up to 200kHz. The two high resolution Analog Inputs can be configured for 4-20mA, 0-10V, or 0-100mV at 14-bit resolution. They also can be configured for 16-bit temperature measurement supporting Thermocouples or RTDs with 0.05 C resolution. The Analog Outputs are sourcing, and can be configured for 4-20mA or 0-10V at 14-bit resolution. Each Analog Input or Output channel can be configured independently for maximum flexibility. Page 7 of 7