Dell Networking N4000 Series and Dell PowerConnect 8100 Series

Similar documents
Dell Networking N2000 Series

Dell Networking S4048-ON

Dell Networking S60 and Dell Force10 S60

Dell EMC Networking S4148-ON and S4128-ON

Dell Networking S3048-ON

Dell Networking S6000

Dell EMC Networking S6010-ON

Dell EMC Networking S4148-ON and S4128-ON

Arista 7050SX-96-F. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide

Cisco Nexus Switch Configuration Guide for Dell SC Series SANs. Dell Storage Engineering August 2015

Dell Force10 S4810 Switch

Huawei CloudEngine 6850

A Dell Interoperability Whitepaper Victor Teeter

Dell Force10 S4810 Switch

Cisco Nexus 9372PX. Switch Configuration Guide for Dell PS Series SANs. A Dell EMC Deployment and Configuration Guide. Dell EMC Engineering June 2017

Cisco Nexus 5648Q. Switch Configuration Guide for Dell PS Series SANs

Best Practices for Mixed Speed Devices within a 10 Gb EqualLogic Storage Area Network Using PowerConnect 8100 Series Switches

Cisco Nexus 5648Q. Switch Configuration Guide for Dell EMC SC Series SANs

Huawei CloudEngine 6850

Cisco Nexus 9372PX. Switch Configuration Guide for Dell EMC SC Series SANs. A Dell EMC Deployment and Configuration Guide

MR2324-4C. 24-Port Intelligent Gigabit Ethernet Switch. Management Guide

Deploying Dell PowerConnect 8100 and Cisco Catalyst Switches

12-Port Intelligent Gigabit Ethernet Switch Management Guide

Supplemental Implementation Guide:

Planning and Preparation Guide

DEPLOYING A STACK OF DELL M-SERIES BLADE SWITCHES IN SIMPLE SWITCH MODE (SSM)

24PORT STACKABLE SWITCH SF-0224FS

Using Switches with a PS Series Group

Best Practices for a DCB-enabled Dell M-Series Blade Solution with EqualLogic PS-M4110

Deployment of Dell M8024-k Blade Switch in Simple Mode with Cisco Nexus 5k Switch

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays

Matrix V-Series V2H FAST ETHERNET SWITCH. Configuration Guide

Using Switches with a PS Series Group

TigerSwitch 10/100/1000

24-Port Fast Ethernet Switch

SAN Design Best Practices for the Dell PowerEdge M1000e Blade Enclosure and EqualLogic PS Series Storage (1GbE) A Dell Technical Whitepaper

Configuring a Dell EqualLogic SAN Infrastructure with Virtual Link Trunking (VLT)

EqualLogic Storage and Non-Stacking Switches. Sizing and Configuration

DELL TM PowerVault TM DL Backup-to-Disk Appliance

17TB and 26TB Data Warehouse Fast Track for Microsoft SQL Server 2014 using PowerEdge R730 Server and Dell Storage PS Series PS6210S

April Brocade VDX 6740 Deployment Guide for VMware EVO:RAIL

Powered by Accton. ES3528M ES3552M Fast Ethernet Switch. Management Guide.

24-Port Fast Ethernet Switch

Reference Architecture for Dell VIS Self-Service Creator and VMware vsphere 4

DGS-3630-Series Switches

Lenovo ThinkSystem NE1032/NE1032T/NE1072T. Release Notes. For Lenovo Cloud Network Operating System 10.6

Switch Configuration Example for Q-SYS Platform Cisco Catalyst 3650 and 3850 Series

Powered by Accton. ES XFP Slot Layer 2 10 Gigabit Ethernet Switch Management Guide.

CCNP Switch Questions/Answers Labs

NW Switch Configuration Guide DX2000. NEC Scalable Modular Server. 1. Introduction. 2. System Configuration. 3. Layer1 Configuration

Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F. Dell Networking Solutions Engineering March 2012

User-Guide. Management Gigabit ETHERNET Workgroup Switch. GigaLION-24TP. GigaLION-24TP. Technical Support Release 1.

SonicWall X Series Solution. Deployment Guide

Lenovo ThinkSystem NE Release Notes. For Lenovo Cloud Network Operating System 10.6

PowerEdge FX2 - Upgrading from 10GbE Pass-through Modules to FN410S I/O Modules

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode)

Management Software AT-S101. User s Guide. For use with the AT-GS950/8POE Gigabit Ethernet WebSmart Switch. Version Rev.

Getting Started. Getting Started with Your Platform Model. Factory Default Configurations CHAPTER

DELL TM PowerVault TM DL Backup-to-Disk Appliance

Dell FluidFS Version 6.0 FS8600 Appliance Deployment Guide

Best Practices for Configuring DCB with VMware ESXi 5.1 and Dell EqualLogic Storage

Switch Quick Configuration CLI Guide for

Dell and Emulex: A lossless 10Gb Ethernet iscsi SAN for VMware vsphere 5

Switch Quick Configuration CLI Guide for

Skills Assessment (OSPF) Student Training Exam

February Connectrix VDX-6740B IP Storage Switch Deployment Guide for VxRail Appliance

Dell EqualLogic Configuration Guide

Configuring VLANs. Understanding VLANs CHAPTER

Skills Assessment (EIGRP) Student Training Exam

Microsoft SharePoint Server 2013 on Dell PowerEdge R630 with Microsoft Hyper-V Virutalization Deployment Guide

MR2228-S2C. Stack Fast Ethernet Switch Management Guide

vstart 50 VMware vsphere Solution Specification

SWP-0208G, 8+2SFP. 8-Port Gigabit Web Smart Switch. User s Manual

Skills Assessment (OSPF) Student Training Exam

Configuring Voice VLAN

Emulex Universal Multichannel

Switch Configuration Example for Q-SYS Platform Extreme Networks Summit X450-G2 Series

Configuring VLANs. Understanding VLANs CHAPTER

Lenovo RackSwitch G8272. Release Notes. For Cloud Network Operating System 10.3

Skills Assessment (EIGRP) Student Training Exam

VERTICAL HORIZON VH-2402S FAST ETHERNET SWITCH MANAGEMENT GUIDE

Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME)

Dell PowerEdge M1000e Blade Enclosure and Dell PS Series SAN Design Best Practices Using Dell S-Series and M-Series Networking

Lenovo NE1032 and NE1032T Switch

Configuring VLANs. Understanding VLANs CHAPTER

Configuring the Fabric Interconnects

Dell EMC Switch Configuration Guide for iscsi and Software-Defined Storage

Dell Compellent FS8600

Cisco. Exam Questions SWITCH Implementing Cisco IP Switched Networks. Version:Demo

Configuring VLANs. Understanding VLANs CHAPTER

Switch Web GUI Quick Configuration Guide for

Database Solutions Engineering. Dell Reference Configuration Deploying Oracle Database on Dell EqualLogic PS5000XV iscsi Storage

Dr. Tom Hicks. Computer Science Department Trinity University

Configuring Virtual Port Channels

Deployment of VMware Infrastructure 3 on Dell PowerEdge Blade Servers

10GbE Network Configuration

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays

EqualLogic iscsi SAN Concepts for the Experienced Fibre Channel Storage Professional A Dell Technical Whitepaper

Switch Configuration Example for Q-SYS Platform HP 1910 and HP 1920

Transcription:

Dell Networking N4000 Series and Dell PowerConnect 8100 Series Switch Configuration Guide for EqualLogic SANs Dell Storage Engineering March 2014 SISfeedback@Dell.com

Revisions Date February 2013 February 2014 Description Initial release Updated branding to include N4000 series March 2014 Revised for Firmware version 6.0.1.3 2014 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without the express written permission of Dell Inc. is strictly forbidden. For more information, contact Dell. Dell, the Dell logo, and the Dell badge, Dell Networking, PowerConnect, EqualLogic, and Force10 are trademarks of Dell Inc. 2 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

Table of contents Revisions... 2 1 Introduction... 5 1.1 Audience... 5 1.2 Switch details... 5 1.3 Cabling diagram... 6 2 Dell recommended switch configuration... 7 2.1 Hardware configuration... 7 2.2 Delete startup configuration... 7 2.3 Disable DCB... 9 2.4 Configure out of band (OOB) management port... 9 2.5 Http and Telnet authentication... 9 2.6 Configure login credentials... 9 2.7 Enable iscsi optimization feature... 10 2.8 Configure flow control (optional)... 10 2.9 Configure Jumbo MTU for all ports... 10 2.10 Configure spanning tree portfast on edge ports... 11 2.11 Configure QSFP ports for LAG... 11 2.12 Save configuration... 11 2.13 Configure additional switch... 11 3 Configure Data Center Bridging (DCB) (Optional)... 12 3.1 Enable DCB... 12 3.2 Create VLAN... 12 3.3 Configure class of service, dot1p mapping, and traffic class... 12 3.4 Configure Priority flow control on switch ports and port channel... 12 3.5 Configure ETS values... 13 3.6 Save configuration... 13 3.7 Configure additional switches... 14 4 Reverting from DCB to non-dcb configuration (Optional)... 15 4.1 Disable DCB and the DCB policies... 15 4.2 Revert to default VLAN ID on switch and arrays... 16 4.3 Save configuration... 16 3 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

4.4 Configure additional switch... 16 Additional resources... 17 4 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

1 Introduction This document illustrates how to configure Dell Networking 4000 Series and Dell PowerConnect 8100 switches for use with EqualLogic PS Series storage using Dell best practices. The recommended configuration uses link aggregation groups (LAGs) for inter-switch connections. Optional steps are provided in Section 3 to enable Data Center Bridging (DCB). If you are following the Rapid EqualLogic Configuration steps at http://en.community.dell.com/techcenter/storage/w/wiki/3615.rapid-equallogic-configuration-portalby-sis.aspx, use Sections 1 and 2 in this Switch Configuration Guide. For more information on EqualLogic SAN design recommendations, see the EqualLogic Configuration Guide at: http://en.community.dell.com/dellgroups/dtcmedia/m/mediagallery/19852516/download.aspx. 1.1 Audience This switch configuration guide describes an optimal configuration following Dell best practices for an EqualLogic iscsi SAN and is intended for storage or network administrators and deployment personnel. 1.2 Switch details The table below provides an overview of the switch configuration. Table 1 Switch specifications Dell Networking N4000 Series or Dell PowerConnect 8100 Switch vendor Dell Switch model Dell Networking N4032, N4032F, N4064, N4064F Dell PowerConnect 8132, 8132F, 8164, 8164F Switch firmware 6.0.1.3 and later The latest firmware updates and documentation can be found at: support.dell.com. 5 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

1.3 Cabling diagram The cabling diagram shown below represents the Dell recommend method for deploying your servers and EqualLogic arrays. Figure 1 Cabling diagram Note: Dell Networking N4064, N4064F and PowerConnect 8164, 8164F switches have two built-in QSFP ports. For the Dell Networking N4032/N4032F and PowerConnect 8132/8132F switches, an optional QSFP uplink module must be installed. 6 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

2 Dell recommended switch configuration These steps show how to configure two Dell PowerConnect 8100 Series or Dell Networking N4000 Series switches with a Link Aggregation Group (LAG). The switches are interconnected using two 40 GbE Quad Small Form-factor Pluggable (QSFP) uplink ports, and the LAG is configured for Dynamic Link Aggregation Control Protocol (LACP). Dell recommends using QSFP (40 Gb) uplink module ports to create a Link Aggregation Group (LAG) between switches. This option can provide the highest switch interconnect bandwidth as well as the best availability. 2.1 Hardware configuration 1. Power on the two switches. 2. Connect a serial cable to the serial port of the first switch. 3. Using Putty or another terminal utility, open a serial connection session to the switch. 4. Open your terminal emulator and configure it to use the serial port (usually COM1, but this may vary depending on your system). Configure serial communications for 9600,N,8,1 and no flow control. 5. Connect the (QSFP) LAG cables between the switches. See this configuration in Figure 1. 2.2 Delete startup configuration Note: All configuration settings will be deleted console>enable console#reload Are you sure you want to reload the stack? (y/n) y Note: The switch will reboot. Follow the prompts shown below when the Main Menu is displayed during the bootup process. Dell Networking Boot Options ============================ Select a menu option within 3 seconds or the Operational Code will start automatically... 1 - Start Operational Code 2 - Display Boot Menu Select (1, 2)# 2 7 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

Boot Main Menu ============== 1 - Start Operational Code 2 - Select Baud Rate 3 - Retrieve Logs 4 - Load New Operational Code 5 - Display Operational Code Details 9 - Reboot 10 - Restore Configuration to Factory Defaults 11 - Activate Backup Image 12 - Start Password Recovery Enter choice number 10. Are sure you want to Erase Current Configuration? (Y/N): Y Erasing Current Configuration...done. Boot Main Menu ============== 1 - Start Operational Code 2 - Select Baud Rate 3 - Retrieve Logs 4 - Load New Operational Code 5 - Display Operational Code Details 9 - Reboot 10 - Restore Configuration to Factory Defaults 11 - Activate Backup Image 12 - Start Password Recovery Enter choice number 9 and the system will reboot. Wait for the following prompt: 8 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

Would you like to run the setup wizard (you must answer this question within 60 seconds)? [Y/N] N 2.3 Disable DCB Note: If you plan to configure DCB (using Section 3) skip this section. For non-dcb environments, DCB must be manually disabled using the following steps: console>enable console#configure console(config)#no dcb enable console(config)#exit 2.4 Configure out of band (OOB) management port console>enable console>#configure console(config)#interface out-of-band console(config-if)#ip address ipaddress mask gateway 2.5 Http and Telnet authentication console>enable console#config console(config)#line telnet console(config-telnet)#login authentication default console(config-telnet)#exit console(config)#ip http authentication local 2.6 Configure login credentials console(config)#username admin password yourpassword privilege 15 console(config)#enable password yourpassword 9 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

console(config)#exit 2.7 Enable iscsi optimization feature This feature, enabled by default, is activated when EqualLogic arrays are detected. It automatically performs the following: Configures jumbo frames to 9216 on all ports. Disables unicast storm. Enables spanning tree portfast on ports connected to EqualLogic arrays. Configures flow control on all ports. Note: Spanning tree portfast must be manually configured for host facing ports. Refer to Section 2.8. console#configure console(config)#iscsi enable Enabling iscsi Optimization will enable Flow Control which may cause all the interfaces to temporarily go down. Are you sure you want to continue? (y/n) y console(config)#exit 2.8 Configure flow control (optional) Note: If iscsi optimization is enabled, flow control is automatically configured on all switch ports upon detection of an EqualLogic Array. If you plan to enable DCB (using Section 3), you may skip this section. console#configure console(config)#flowcontrol receive on This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to continue? (y/n)y console(config)#exit 2.9 Configure Jumbo MTU for all ports console(config)#system jumbo mtu 9216 console(config)# exit 10 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

2.10 Configure spanning tree portfast on edge ports Note: If iscsi optimization is enabled, spanning tree portfast is automatically configured on ports connected to EqualLogic arrays. These manual steps must be performed on switch ports connected to hosts servers. console#configure console(config)#interface range tengigabitethernet all console(config-if)#spanning-tree portfast 2.11 Configure QSFP ports for LAG These commands assign 40Gb QSFP ports to the Port Channel. console(config)#interface range fortygigabitethernet 1/0/1-2 Note: Port numbering for the 40Gb QSFP ports may vary by switch model and module configuration. Confirm the correct port range for your configuration. console(config-if)#no spanning-tree portfast console(config-if)#channel-group 1 mode active 2.12 Save configuration console#copy running-config startup-config This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n)y 2.13 Configure additional switch Repeat the commands from Section 2 to configure the second switch. Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in a non-default VLAN, refer to the documentation for your switch. 11 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

3 Configure Data Center Bridging (DCB) (Optional) DCB is enabled by default. This section shows the steps required to configure DCB. Note: You must complete the Dell recommended switch configuration steps in Sections 2.1 to 2.12 before configuring the switch for DCB mode. 3.1 Enable DCB If DCB was previously disabled, it must be manually re-enabled. console#configure console(config)#dcb enable 3.2 Create VLAN console#configure console(conf)# vlan vlan-id Note: You must supply a VLAN id. The valid range is 2-4093. console(conf)#exit 3.3 Configure class of service, dot1p mapping, and traffic class console(config)#iscsi cos enable console(config)#iscsi cos vpt 4 console(config)#classofservice dot1p-mapping 4 4 console(config)#classofservice traffic-class-group 4 1 3.4 Configure Priority flow control on switch ports and port channel console(config)#interface range tengigabitethernet all console(config-if)#datacenter-bridging console(config-if-dcb)#priority-flow-control mode on console(config-if-dcb)#priority-flow-control priority 4 no-drop console(config-if-dcb)#exit console(config-if)#switchport mode trunk 12 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

console(config)#interface range fortygigabitethernet 1/0/1-2 Note: Port numbering for the 40Gb QSFP ports may vary by switch model and module configuration. Confirm the correct port range for your configuration. console(config-if)#datacenter-bridging console(config-if-dcb)#priority-flow-control mode on console(config-if-dcb)#priority-flow-control priority 4 no-drop console(config-if-dcb)#exit console(config-if)#switchport mode trunk console(config)#interface port-channel 1 console(config-if-po1)#switchport mode trunk console(config-if-po1)#exit 3.5 Configure ETS values console(config)#traffic-class-group weight 50 50 0 Note: This command uses an example of 50% non-iscsi traffic (first parameter) and 50% iscsi traffic (second parameter). The sum of the bandwidth-percentages must be equal to 100. console(config)#exit 3.6 Save configuration console# copy running-config startup-config This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n)y 13 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

3.7 Configure additional switches Repeat the commands from Section 3 to configure DCB on additional switches. 14 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

4 Reverting from DCB to non-dcb configuration (Optional) One method to revert from a DCB configured switch to a non-dcb configured switch is to delete the current configuration (startup-config) and follow the steps in Section 2. If deleting the current configuration is not an option, then use the following procedure to unconfigure DCB and enable standard flow control. Note: This is a disruptive operation that requires down time. The arrays will temporarily lose communication with each other. Power off all arrays and hosts connected to the SAN before proceeding with these steps. 4.1 Disable DCB and the DCB policies console#configure console(config)#no dcb enable console(config)# no traffic-class-group weight console(config)#no classofservice dot1p-mapping console(config)#no classofservice traffic-class-group console(config)#no iscsi cos console(config)#interface range tengigabitethernet all console(config-if)#datacenter-bridging console(config-if-dcb)#no priority-flow-control mode console(config-if-dcb)#no priority-flow-control priority console(config-if-dcb)#exit console(config)#interface range fortygigabitethernet all console(config-if)#datacenter-bridging console(config-if-dcb)#no priority-flow-control mode console(config-if-dcb)#no priority-flow-control priority console(config-if-dcb)#exit 15 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

4.2 Revert to default VLAN ID on switch and arrays Once DCB is disabled on the switch, the EqualLogic arrays will no longer use the VLAN ID that was configured when DCB was enabled. The arrays will revert to the default or native VLAN. Therefore, a valid VLAN must be configured for all host servers, switches, and EqualLogic array members. A valid VLAN can use the default or native VLAN ID (typically 0 or 1) or a specific VLAN can be configured (for example, VLAN 100). If a non-default VLAN is configured, then any ports connected to the arrays must be configured as untagged. Use the steps below to configure the native VLAN on the switch. console#configure console(config)#interface range tengigabitethernet all console(config-if)#no switchport mode console(config)#interface range fortygigabitethernet all console(config-if)#no switchport mode console(config)#interface port-channel 1 console(config-if)#no switchport mode console(config)#no vlan vlan-id console(config)#exit 4.3 Save configuration console# copy running-config startup-config This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n)y 4.4 Configure additional switch Repeat the commands from Section 4 to disable DCB on any additional switches. 16 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide

Additional resources Support.dell.com is focused on meeting your needs with proven services and support. DellTechCenter.com is an IT Community where you can connect with Dell Customers and Dell employees for the purpose of sharing knowledge, best practices, and information about Dell products and your installations. Referenced or recommended Dell publications: Dell EqualLogic Configuration Guide: http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/19852516/download.aspx Dell EqualLogic Compatibility Matrix: http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/19856862/download.aspx For EqualLogic best practices white papers, reference architectures, and sizing guidelines for enterprise applications and SANs, refer to Storage Infrastructure and Solutions Team Publications at: http://dell.to/sm4hjt 17 SCG1001 Dell Networking N4000 Series and Dell PowerConnect 8100 Series Configuration Guide