Service & Support. Which dependencies exist between the safety functions of the SINAMICS S120 drive system? Technology CPU.

Similar documents
Service & Support. How can the Safety Functions of SINAMICS S120 be activated in an existing STEP 7 Project? Technology CPU.

Applications & Tools. Control of the Safety Integrated Extended Functions of the SINAMICS S110 via the fail-safe inputs of the CU305 SINAMICS S110

SINAMICS G120 SINAMICS G120C

SINAMICS. Safety. SINAMICS G120, G120C, G120D, G110M, SIMATIC ET 200pro FC-2 inverters. Function Manual

SINAMICS SINAMICS G120. Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F. Function Manual Safety Integrated 07/2010

Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2 SINAMICS

SINUMERIK 840D sl Safety Integrated / Safety Integrated plus Safe machines with a high productivity. Unrestricted Siemens AG 2018

Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2 SINAMICS

Applications & Tools. SINAMICS S120: Control of the Safety Integrated Basic Functions via onboard terminals SINAMICS S120

Safety technology with SINUMERIK Safety Integrated SINUMERIK. SINUMERIK 840D sl / 828D Safety technology with SINUMERIK Safety Integrated

Transform your Drive Safety Capability with Innovative Market Driven Technology Presented by Craig Nelson Manufacturing in America March 14-15, 2018

Application of CIP Safety for functional safety in motion applications - analysis of CIP Safety motion application use case scenarios

SINAMICS S120 Safety Integrated Extended Functions

SINAMICS S120 Safety Integrated Extended Functions

Table 1: Safety Function (SF) Descriptions

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

SIMOTION with SINAMICS S120 Safety Integrated Extended Functions Fail-safe drives connected to SIMOTION D435 Controlled with PROFIsafe via PROFIBUS

SIMOTION with SINAMICS S120 Safety Integrated Extended Functions Fail-safe drives Controlling a D435 via TM54F and F-CPU

Welcome to the overview of ACS880 functional safety, FSO-11 Safety functions module.

Changeover SINAMICS CU240E to CU240E-2 (as from Firmware V4.4) SINAMICS G120. FAQ October Service & Support. Answers for industry.

Drives Based Safety Integrated

Applications & Tools. Controlling distributed I/Os and drives from two controllers via PROFINET (Shared Device via Object Manager) SIMATIC & SINAMICS

3 CU240E-2 6SL3244-0BB12-1BA1 3 CU240E-2 DP 6SL3244-0BB12-1PA1. RS485/USS 6 3 (opt. per 2 DI) 3 CU240E-2 F 6SL3244-0BB13-1BA1

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

CIP Safety for Drives


Applications & Tools. Controlling distributed I/Os and drives from two controllers via PROFINET (Shared Device via GSD file) SIMATIC & SINAMICS S

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

Applications & Tools. Application to support the acceptance test of the Safety Integrated Functions of SINAMICS G120 SINAMICS G120

Applications & Tools. Calculation examples for safety functions according to EN ISO SINUMERIK 840D sl

ID Title Description of the restriction Solutions for the restriction


Conveyor System Utilizing Safety Observation Function

TwinSAFE Scalable Safety Solutions. Dr. Guido Beckmann Technology Marketing

ISO SINAMICS G110D FAQ

Applications & Tools. Controlling the CU320-2 via PROFIsafe with PROFIBUS SINAMICS S120. Application example July Answers for industry.

Spring Training Atlanta, GA

SINAMICS S120 Safety Integrated Extended Functions Fail-Safe Drives Controlling the CU320 from a TM54F and F-CPU

Review of the CIP Safety SafeMotion Profile Functionality

Welcome to the Safety functions training module for ACS880 cabinet-built industrial drives.

Application for Process Automation

Applications & Tools. Controlling the CU320-2 via TM54F and F-CPU with PROFIBUS in conjunction with EPOS SINAMICS S120

Applications & Tools. Controlling Safety Integrated Extended Functions and transferring the F-DIs of the CU310-2 PN via PROFIsafe with PROFINET

SINAMICS Siemens Controlss

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC Functional Safety

Applications & Tools. Controlling distributed I/Os and drives from two controllers via PROFINET (Shared Device via Object Manager) SIMATIC & SINAMICS


Manual. Decentralized Extra-Low Voltage Servo Drive CMP ELVCD Functional Safety * _0717*

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

SIMATIC Safety Integrated for Factory Automation

Function Example No. MC-FE-I-011-V10-DE

* _1216* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC..

SIEMENS. General conditions and function limitations, notes for configuration and operation

Flexible and high performance. The SINAMICS S120 drive system. SINAMICS drives. Answers for industry.

Siemens Spares. SIMOCRANE Drive-Based Sway Control. Preface. Fundamental safety instructions 1. System description 2. Hardware interfaces 3

SINAMICS G: Positioning a G120 CU250S-2 with S7-300/400 (STEP 7 V5) via PROFINET/PROFIBUS using Safety Integrated (via PROFIsafe) and HMI

Welcome to the safety functions configuration training module for ACS880 Cabinet-built industrial drives.

Applications & tools. Control of AS-i position switch with interlock per MSS 3RK3 SIRIUS MSS 3RK3. FAQ March Answers for industry.

LOW VOLTAGE AC DRIVES. Crane control and safety with ACS880 drives

Motor controllers CMMD-AS, for servo motors

Service & Support. How do I configure extended PROFIsafe on the CU240E-2?

Options for ABB drives. User s manual Prevention of unexpected start-up (option +Q950) for ACS880-07/17/37 drives

Options for ABB drives. User s manual Emergency stop, stop category 1 (option +Q964) for ACS880-07/17/37 drives

Applications & Tools. Control of the Safety Integrated Extended Functions for the CU320-2 (with FW V4.4) in conjunction with EPOS SINAMICS S120

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIPRO Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. CCU Universal Module Application Module

SINUMERIK Safety Integrated. Possible Encoder Connections

Safety Integrated. Introduction

Flexible and high performance. The SINAMICS S120 drive system. SINAMICS drives. Answers for industry.

Documentation for. AX TwinSAFE Drive Option. TwinSAFE Drive Option for AX8xxx-x1xx Servo Drives. Version: Date: 1.0.

Description and Tutorial for. SIMOCRANE Drive-Based Technology V1.0 SP1 HF2. with Sinamics CU 310-2

Applications & Tools. Safe switching of the motor starters 3RM10 and 3RM12. SIRIUS Safety. FAQ February Answers for industry.

S Motion Control V12 SP1 SIMATIC. STEP 7 S Motion Control V12 SP1. Preface. Using S Motion Control. S Motion Control 2

Motion Control Products Application note Implementing safety functions on ABB servo drives

Copley Indexer 2 Program User Guide

What is your drive? Lead instead of follow? SINAMICS S120: the high-performance drive system.

WHITE PAPER. Drive-based functional safety How variable speed drives are playing an increasingly important role in machine safety

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview

Programmable modular safety controller PROTECT PSC1

Welcome Guideline D435 training case with SIMOTION 4.1 SP1

Operating Instructions MOVISAFE UCS.B Safety Modules

SINAMICS S120 Family New functions in firmware V4.6 and STARTER V4.3 SP2

Servo drives. SafeMotion

Safe shutdown of SIRIUS 3RA6 compact starters with IO-Link interface. SIRIUS Industrial Controls, Safety Integrated, IO-Link FAQ 05.

CMMT-AS-PN controlled by SINAPOS functions block with Siemens S controller


SIMOCRANE Drive-Based Sway Control

Compact Power for Decentralized Applications MOVIPRO SDC/ADC

Applications & Tools. Technology CPU 317TF-2 DP: Example for determining the Safety Integrity Level (SIL) according to IEC

Drive inverter for asynchronous AC motors without encoder feedback. The units are not option capable.

Migration of CU240E/S to CU240B/E-2 and CU250S-2 (firmware V4.5) SINAMICS G120. FAQ March Service & Support. Answers for industry.

Control strategies for web handling

Options for ABB drives. User s manual Prevention of unexpected start-up (option +Q957) for ACS880-07/17/37 drives

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Kinetix 5700 Safe Monitor Functions

How to setup Travel to fixed stop with CMMT-AS-PN by using the SINA_POS / telegram 111

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Revision. Decentralized Drive and Application Control MOVIPRO ADC with PROFINET interface * _1017*

Functional safety. For control cabinet drive technology MOVISAFE Functional safety integrated in the inverter. Features and benefits

Motion Control with Failsafe Requirements

Transcription:

Cover Which dependencies exist between the safety functions of the SINAMICS S120 drive system? Technology CPU FAQ March 2011 Service & Support Answers for industry.

Question This entry is from the Service&Support portal of Siemens AG, Sector Industry, Industry Automation and Drive Technologies. The general terms of use (http://www.siemens.com/terms_of_use) apply. Clicking the link below directly displays the download page of this document. http://support.automation.siemens.com/ww/view/en/48206059 Question Which dependencies exist between the safety functions of the SINAMICS S120 drive system? Answer The instructions and notes listed in this document provide a detailed answer to this question. V1.0, ItemID: 48206059 2

Table of Contents Table of Contents 1 Introduction... 4 1.1 Safety functions of SINAMICS S120... 4 1.1.1 Safety Integrated Basic Functions... 4 1.1.2 Safety Integrated Extended Functions... 5 1.1.3 Active safety functions and safe monitoring functions... 5 1.1.4 Summary... 6 1.2 Operation with and without encoder... 6 1.3 Controlling the safety functions... 7 1.4 Notes on the graphical representation... 8 1.4.1 Legend... 8 1.4.2 Structure of the charts... 8 2 Safety Integrated Basic Functions... 9 2.1 Safe Torque Off (STO)... 9 2.2 Safe Stop 1 (SS1, time controlled)... 9 2.3 Safe Brake Control (SBC)... 9 2.4 Graphical overview... 9 3 Safety Integrated Extended Functions... 11 3.1 Safe Torque Off (STO)... 11 3.2 Safe Stop 1 (SS1, time and acceleration controlled)... 11 3.3 Safe Stop 2 (SS2)... 11 3.4 Safe Operating Stop (SOS)... 12 3.5 SafelyLimited Speed (SLS)... 12 3.6 Safe Speed Monitor (SSM)... 13 3.7 Safe Acceleration Monitor (SBR)... 13 3.8 Safe Brake Ramp (SBR)... 13 3.9 Graphical overview... 14 4 Additional Information... 19 4.1 Designing the Safety Integrated Functions... 19 4.1.1 Setting the delay times... 19 4.1.2 Setting the brake ramps... 19 4.1.3 Selecting the appropriate Safety Integrated Function... 19 4.2 Crosswise data comparison... 20 4.3 Forced dormant error detection... 20 4.3.1 Procedure for Safety Integrated Basic Functions... 20 4.3.2 Procedure for Safety Integrated Extended Functions... 21 V1.0, ItemID: 48206059 3

1 Introduction 1 Introduction The intention of this FAQ is to graphically represent the textual description of the dependencies of the SINAMICS S120 safety functions from the Function Manual in several overviews. Note The preparation of this FAQ was based on the Function Manual from the SINAMICS S120 documentation. SINAMICS S120 Safety Integrated Function Manual Siemens Manual Edition: 05/2010 (valid for firmware V4.3 SP2) MLFB: 6SL30974AR000BP1 1.1 Safety functions of SINAMICS S120 SINAMICS S120 provides the following Safety Integrated Functions: Safety Integrated Basic Functions These functions are included in the standard scope of the drive and can be used without an additional license. Safety Integrated Extended Functions These functions require additional licensing of the drive. Inadequate licensing is indicated by a warning (A13000) and the RDY LED (flashes green/red at 0.5 Hz). Note The functions listed here conform to IEC 61508, SIL2, in an operating mode with a high requirement rate, Category 3 and Performance Level d (PL d) according to ISO 138491 (2006) and IEC 6180052. 1.1.1 Safety Integrated Basic Functions The following Safety Integrated Basic Functions are available in the SINAMICS S120 drive system: Safe Torque Off (STO) STO is a safety function that prevents the drive from restarting unexpectedly, according to EN602041:2006 Section 5.4. Safe Stop 1 (SS1, time controlled) Safe Stop 1 is based on the Safe Torque Off function. This means that a Category 1 stop in accordance with EN 602041:2006 can be implemented. Safe Brake Control (SBC) The SBC function allows the safe control of a holding brake. Note on Power/Motor Modules in chassis format: For chassis format, SBC is only supported by Power/Motor Modules with order number...3 or higher. A Safe Brake Adapter (SBA) is additionally necessary. Note on Power/Motor Modules in blocksize format: Blocksize Power Modules additionally require a Safe Brake Relay for this function. V1.0, ItemID: 48206059 4

1 Introduction 1.1.2 Safety Integrated Extended Functions The following Safety Integrated Extended Functions are available in the SINAMICS S120 drive system: Safe Torque Off (STO) STO is a safety function that prevents the drive from restarting unexpectedly, according to EN602041:2006 Section 5.4. Safe Stop 1 (SS1, time and acceleration controlled) The SS1 function is based on the Safe Torque Off function. This means that a Category 1 stop in accordance with EN 602041:2006 can be implemented. Safe Stop 2 (SS2) The SS2 function brakes the motor safely with a subsequent transition to Safe Operating Stop (SOS). This means that a Category 2 stop in accordance with EN 602041:2006 can be implemented. Safe Operating Stop (SOS) SOS protects against unintentional movement. The drive is in closedloop control mode and not disconnected from the power supply. SafelyLimited Speed (SLS) The SLS function is used to protect the drive against unintentionally high speeds. Safe Speed Monitor (SSM) The SSM function safely monitors a speed limit and issues a safe output signal without influencing the speed. Safe Acceleration Monitor (SBR) The Safe Acceleration Monitor function safely monitors a drive when it accelerates. It is part of the SS1 and SS2 functions. Safe Brake Ramp (SBR) The Safe Brake Ramp function safely monitors the brake ramp. It is part of the SS1 without encoder and SLS without encoder functions. 1.1.3 Active safety functions and safe monitoring functions Basically, the Safety Integrated Functions of SINAMICS S120 can be further divided into two categories: Active safety functions When activating an active safety function on SINAMICS S120, the drive actively intervenes in the operation of the relevant axis and executes the activated safety function. This Safety Integrated Function category includes: Safe Torque Off (STO) Safe Stop 1 (SS1, time controlled or time and acceleration controlled) Safe Stop 2 (SS2) Safe Brake Control (SBC) Safe monitoring functions When activating a safe monitoring function on SINAMICS S120, the drive initially does not intervene in the operation of the axis, it is limited to safe monitoring of the axis. The drive actively intervenes in the operation of the relevant axis by calling an active safety function only after a limiting condition of the monitoring function, for example a delay time. This Safety Integrated Function category includes: V1.0, ItemID: 48206059 5

1 Introduction Safe Operating Stop (SOS) SafelyLimited Speed (SLS) Safe Speed Monitor (SSM) 1.1.4 Summary This chapter once again shows the Safety Integrated Basic Functions and the Safety Integrated Extended Functions of SINAMICS S120 in a table. Basic Functions Extended Functions Function With encoder Without encoder Brief description STO Safe Torque Off X X Safe torque off SS1 Safe Stop 1 X X Safe stopping according to stop category 1 SBC Safe Brake Control X X Safe brake control STO Safe Torque Off X X Safe torque off SS1 Safe Stop 1 X X Safe stopping according to stop category 1 SS2 Safe Stop 2 X Safe stopping according to stop category 2 SOS Safe Operating X Safe monitoring of Stop the standstill position SLS SafelyLimited Speed X X Safe monitoring of the maximum speed SSM Safe Speed Monitor X Safe monitoring of the minimum speed SBR Safe Acceleration Monitor X Safe monitoring of the drive acceleration SBR Safe Brake Ramp X Safe brake ramp 1.2 Operation with and without encoder When using asynchronous motors, specific Safety Integrated Functions can also be used without an encoder. In operation without encoder, the speed actual values are calculated from the measured electrical ACTUAL values. This ensures that speed monitoring down to n = 0 min 1 is also possible in operation without encoder. Note This FAQ addresses only the use of the Safety Integrated Functions of SINAMICS S120 with encoder. For characteristic features of the use of specific Safety Integrated Functions without encoder, please refer to the SINAMICS S120 Function Manual. V1.0, ItemID: 48206059 6

1 Introduction 1.3 Controlling the safety functions The Safety Integrated Functions can be controlled via terminals, via a PROFIsafe telegram by means of PROFIBUS or via the TM54F Terminal Module (Extended Functions only). Control via terminals and TM54F or terminals and PROFIsafe can be selected simultaneously. NOTICE Using a control unit, control is possible either via PROFIsafe or TM54F. Mixed operation is not permissible. Structure of PROFIsafe telegram 30 The control word (STW) of PROFIsafe telegram 30 for the control of the Safety Integrated Functions of SINAMICS S120 via PROFIBUS is structured as follows: Table 11 Control word of PROFIsafe telegram 30 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 STO SS1 SS2 SOS SLS Int. Event ACK SLS Bit 0 SLS Bit 1 STW The status word (ZSW) of PROFIsafe telegram 30 for feedback of the Safety Integrated Functions that are active in the drive is structured as follows: Table 12 Status word of PROFIsafe telegram 30 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 STO aktiv SS1 aktiv SS2 aktiv SOS aktiv SLS aktiv Int. Event Aktives SLS Bit 0 Aktives SLS Bit 1 SOS angewählt SSM ZSW V1.0, ItemID: 48206059 7

1 Introduction 1.4 Notes on the graphical representation The graphical representation of the dependencies of the Safety Integrated Functions of SINAMICS S120 uses the following methods of representation: 1.4.1 Legend Table 13 Legend for the graphical representations Representation SBC Safe Brake Contr. Safe control of a brake Description Safety Integrated Basic Function of SINAMICS S120. SOS Safe Operating Stop Monitoring of the standstill position of the drive STOP A Drive coasts (corresponds to Safe Torque Off ) STO Safe Torque Off Safe pulse suppression in the drive OFF 2 Safety Integrated Extended Function of SINAMICS S120. Internal error response of the safety functions of SINAMICS S120. Safety Integrated Basic Function of SINAMICS S120, including information on the stop function of the drive activated by the safety function. 1.4.2 Structure of the charts The arrangement of the safety functions in the individual charts is based on a thematic allocation. Note The purpose of the charts is to provide the reader with an overview of the dependencies of the individual safety functions of SINAMICS S120; the charts do not claim to be complete regarding the shown functions. V1.0, ItemID: 48206059 8

2 Safety Integrated Basic Functions 2 Safety Integrated Basic Functions 2.1 Safe Torque Off (STO) Active safety function for safe pulse suppression in the drive. This is used to safely prevent an unexpected start of the axis. As an option, the Safe Torque Off (STO) Safety Integrated Function can be connected with the automatic activation of the Safe Brake Control (SBC) Safety Integrated Function. In this case, the closing of a holding brake on the axis when initiating the Safe Torque Off (STO) function is automatically controlled safely by the drive with the aid of the Safe Brake Control (SBC) function. 2.2 Safe Stop 1 (SS1, time controlled) Active safety function for safe stopping of an axis via the OFF 3 ramp parameterized in the drive. The Safe Stop 1 (SS1) Safety Integrated Function causes the axis to decelerate along the parameterized OFF 3 ramp. In this process, however, the safety function as a Basic Function does not monitor the brake ramp of the drive. After a delay time has elapsed, the Safe Torque Off (STO) Safety Integrated Function is started and the pulses of the drive are safely suppressed. If the axis is not at a standstill during the transition to the Safe Torque Off (STO) Safety Integrated Function because, for example, the selected OFF 3 brake ramp is too short for the current axis velocity, the internal error response of the STOP A Safety Integrated Function will (optionally) be called, which causes immediate pulse suppression. Due to this, the still moving axis coasts to a standstill. Note When selecting the OFF 3 brake ramp and the delay time for the Safe Stop 1 (SS1) Safety Integrated Function, always base the selection on the maximum axis velocity that can be reached on the machine to ensure that the axis safely comes to a standstill after the delay time has elapsed. 2.3 Safe Brake Control (SBC) Active safety function for the safe control of a holding brake of an axis. This Safety Integrated Function can optionally be connected with the Safe Torque Off (STO) function; when connecting these two functions, safe management of the holding brake during pulse suppression will be performed by the drive. 2.4 Graphical overview The figure below provides a graphical overview of the Safety Integrated Basic Functions of SINAMICS S120. V1.0, ItemID: 48206059 9

2 Safety Integrated Basic Functions Figure 21 Characteristics of the Basic Safety Functions of SINAMICS S120 Error in crosswise data comparison Activation STOP F Error in crosswise data comparison SS1 Safe Stop 1 Drive is decelerated along the OFF3 ramp OFF 3 Activation of SS1: p9652/p9852 > 0 OFF3 ramp: p1135 Delay time: p9652/p9852 After a delay time has elapsed p9658/p9858 Factory setting: Delay time = 0 Activation of SBC: p9602/p9802 After the delay time has elapsed p9652/p9852 STOP A Drive coasts (corresponds to Safe Torque Off ) Optional SBC Safe Brake Contr. Safe control of a brake Optional STO Safe Torque Off Safe pulse suppression in the drive OFF 2 Activation V1.0, ItemID: 48206059 10

3 Safety Integrated Extended Functions 3 Safety Integrated Extended Functions Note The graphical representation of the Safety Integrated Functions is thematically structured; due to this, it is possible that individual Safety Integrated Functions are shown in several charts. 3.1 Safe Torque Off (STO) Active safety function for safe pulse suppression in the drive. This is used to safely prevent an unexpected start of the axis. As an option, the Safe Torque Off (STO) Safety Integrated Function can be connected with the automatic activation of the Safe Brake Control (SBC) Safety Integrated Basic Function. In this case, the closing of a holding brake on the axis when initiating the Safe Torque Off (STO) function is automatically controlled safely by the drive with the aid of the Safe Brake Control (SBC) function. 3.2 Safe Stop 1 (SS1, time and acceleration controlled) Active safety function for safe stopping of an axis via the OFF 3 ramp parameterized in the drive. The Safe Stop 1 (SS1) Safety Integrated Function causes the axis to decelerate along the parameterized OFF 3 ramp. In this process, the deceleration of the axis is monitored via the Safe Acceleration Monitor (SBR) Safety Integrated Function. After reaching the shutdown speed or after the delay time has elapsed, the Safe Torque Off (STO) Safety Integrated Function is started and the pulses of the drive are safely suppressed. Note When selecting the OFF 3 brake ramp and the delay time for the Safe Stop 1 (SS1) Safety Integrated Function, always base the selection on the maximum axis velocity that can be reached on the machine to ensure that the axis safely comes to a standstill after the delay time has elapsed. 3.3 Safe Stop 2 (SS2) Active safety function for safe braking of the motor with a subsequent transition to Safe Operating Stop (SOS). The Safe Stop 2 (SS2) Safety Integrated Function causes the axis to decelerate along the parameterized OFF 3 ramp. In this process, the deceleration of the axis is monitored via the Safe Acceleration Monitor (SBR) Safety Integrated Function. After a delay time has elapsed, the Safe Operating Stop (SOS) Safety Integrated Function is started, which safely monitors the drive against unintentional movement. The actual drive, however, remains fully active and keeps the axis in closedloop control mode. V1.0, ItemID: 48206059 11

3 Safety Integrated Extended Functions Safety fault on Safe Acceleration Monitor/Safe Brake Ramp (SBR) If the parameterized velocity tolerance is violated when monitoring the brake ramp using the Safe Acceleration Monitor (SBR) Safety Integrated Function, STOP A will be initiated and the drive will coast to a standstill without power supply. Safety fault on Safe Operating Stop (SOS) If the standstill tolerance is violated when monitoring the safe standstill of the axis using the Safe Operating Stop (SOS) Safety Integrated Function, STOP B will be initiated and the drive will be decelerated to a standstill via the OFF 3 ramp. After the delay time has elapsed or if the shutdown velocity of the axis is undershot or the velocity tolerance for deceleration is overshot, STOP A will be initiated and the axis will coast to a standstill without power supply. 3.4 Safe Operating Stop (SOS) Safe monitoring function to protect against unintentional movement. The drive is in closedloop control mode and not disconnected from the power supply. If the standstill tolerance is violated when monitoring the standstill of the axis, STOP B with subsequent STOP A will be initiated, decelerating the axis along the OFF 3 ramp and disconnecting it from the power supply. 3.5 SafelyLimited Speed (SLS) Safe monitoring function to protect against unintentionally high speeds of the drive. When activating the SafelyLimited Speed (SLS) Safety Integrated Function, a delay time is started within which the axis velocity must be reduced by the higherlevel control system below the value configured in the safety function. Optional configuration of the response to a safety fault The response to a safety fault of the SafelyLimited Speed (SLS) Safety Integrated Function, e.g. exceeding the configured axis velocity, can be optionally parameterized. The following table serves as an example of the selection of the respective response to a safety fault. Table 31 Response of Safely Limited Speed (SLS) to a safety fault Response STOP D (= SOS) STOP C (= SS2) Comment The drive must be decelerated by the higherlevel control system within the configured transition time (bit 3 SOS active is set in the status word of the PROFIsafe telegram). The standstill of the axis is then monitored via the Safe Operating Stop (SOS) Safety Integrated Function. The axis remains in closedloop control mode. This setting is, for example, useful when axes move in a coordinated fashion (interpolation) if the coordination of the axes is not to be lost during the deceleration process (e.g., the trajectory is not to be left). The drive is decelerated via the configured OFF 3 ramp. If the velocity tolerance is violated before or after the deceleration process, the drive will go to STOP A, disconnecting the drive from the power supply V1.0, ItemID: 48206059 12

3 Safety Integrated Extended Functions Response STOP B (= SS1) STOP A (= STO) Comment by immediate pulse suppression. The standstill of the axis is monitored via the Safe Operating Stop (SOS) Safety Integrated Function. The axis remains in closedloop control mode. This setting is, for example, useful for single axes that can be decelerated using the OFF 3 drive function and, monitored using Safe Operating Stop (SOS), are then to remain in closedloop control mode. The drive is decelerated via the configured OFF 3 ramp. If the velocity tolerance is violated before or after the deceleration process, the drive will go to STOP A, disconnecting the drive from the power supply by immediate pulse suppression. This setting is, for example, useful for single axes that can be decelerated using the OFF 3 drive function and are then not to remain in closedloop control mode but can be disconnected from the power supply. The drive is disconnected from power supply by immediate pulse suppression, which causes the axis to coast to a standstill. This setting is, for example, only useful for axes that can coast freely to a standstill or have an operating brake for mechanical stopping of the axis. 3.6 Safe Speed Monitor (SSM) Safe monitoring function to monitor a specified speed limit with output of a safe output signal, without causing an influence of the drive. This monitoring function will be automatically activated once a Safety Integrated Extended Function has been configured in SINAMICS S120. 3.7 Safe Acceleration Monitor (SBR) Safe monitoring function to monitor incorrect acceleration of the drive with active Safe Stop 1 (SS1) and Safe Stop 2 (SS2) Safety Integrated Extended Function or STOP A and STOP B. 3.8 Safe Brake Ramp (SBR) Safe monitoring function to monitor the brake ramp of the drive in operation without encoder. This function is part of the Safe Stop 1 (SS1) and Safe Stop 2 (SS2) Safety Integrated Extended Function in operation without encoder. Note The following graphical representations of the dependencies of the SINAMICS S120 safety functions do not address operation without encoder. For characteristic features of the use of specific safety functions without encoder, please refer to the SINAMICS S120 Function Manual. V1.0, ItemID: 48206059 13

3 Safety Integrated Extended Functions 3.9 Graphical overview The following four figures provide a graphical overview of the Safety Integrated Extended Functions of SINAMICS S120. Safety Integrated Extended Functions part 1 Safe Torque Off (STO) incl. Safe Brake Control (SBC) Safe Stop 1 (SS1) incl. Safe Acceleration Monitor (SBR) Safety Integrated Extended Functions part 2 Safe Operating Stop (SOS) Safe Stop 2 (SS2) incl. Safe Acceleration Monitor (SBR) Safety Integrated Extended Functions part 3 Safely Limited Speed (SLS) Safe Operating Stop (SOS) Safety Integrated Extended Functions part 4 Safe Speed Monitor (SSM) V1.0, ItemID: 48206059 14

3 Safety Integrated Extended Functions Figure 31 Characteristics of the Safety Integrated Extended Functions of SINAMICS S120 (with encoder) part 1 Error in crosswise data comparison Error in crosswise data comparison STOP F Error in crosswise data comparison Transition time elapsed p9355/p9555 Activation STOP B Drive is decelerated along the OFF3 ramp (corresponds to Safe Stop 1 Delay time elapsed p9356/p9556 OR shutdown velocity reached p9360/p9560 Tolerance violated p9348/p9548 SBR Safe Acc. Monitor Safe monitoring of acceleration/deceleration Activation of SBR: Automatically with activation of SS1 SS1 Safe Stop 1 Drive is decelerated along the OFF3 ramp Delay time elapsed p9356/p9556 OR Shutdown speed reached p9360/p9560 OFF 3 Activation of SS1: p9356/p9556 > 0 OFF3 ramp: p1135 Delay time: p9356/p9556 Shutdown speed: p9360/p9560 Velocity tolerance p9348/p9548 Velocity limit p9368/p9568 or p9346/p9546 (if p9368/p9568=0) STOP A Drive coasts (corresponds to Safe Torque Off ) SBC Safe Brake Contr. Safe control of a brake Optional STO Safe Torque Off Safe pulse suppression in the drive OFF 2 Activation of SBC: p9602/p9802 Activation V1.0, ItemID: 48206059 15

3 Safety Integrated Extended Functions Figure 32 Characteristics of the Safety Integrated Extended Functions of SINAMICS S120 (with encoder) part 2 Error in crosswise data comparison Error in crosswise data comparison Activation STOP F Error in crosswise data comparison After a delay time has elapsed p9658/p9858 Factory setting: Delay time = 0 Activation of SBR: Automatically with activation of SS2 STOP C Drive is decelerated along the OFF3 ramp Activation of SS2: p9352/p9552 Tolerance violated p9348/p9548 Tolerance violated p9348/p9548 OR delay time elapsed p9356/p9556 OR shutdown velocity undershot p9360/p9560 SBR Safe Acc. Monitor Safe monitoring of acceleration/deceleration STOP B Drive is decelerated along the OFF3 ramp (corresponds to Safe Stop 1 ) Standstill tolerance violated p9330/p9530 Error in crosswise data comparison SS2 Safe Stop 2 Drive is decelerated along the OFF3 ramp Delay time has elapsed p9352/p9552 SOS Safe Operating Stop Monitoring of the standstilll position of the drive Transition time has elapsed p9353/p9553 Delay time has elapsed p9351/p9551 OFF3 ramp: p1135 Delay time: p9352/p9552 Na. brake ramp: p9381/p9581 Activation of SOS: Function selection Delay time: p9351/p9551 Standstill tol.: p9330/p9530 Activation STOP A Drive coasts (corresponds to Safe Torque Off ) STOP F Error in crosswise data comparison STOP D Drive must be decelerated by the higherlevel control system V1.0, ItemID: 48206059 16

3 Safety Integrated Extended Functions Figure 33 Characteristics of the Safety Integrated Extended Functions of SINAMICS S120 (with encoder) part 3 SOS or SLS active or SSM hysteresis active STOP F Error in crosswise data comparison Error in crosswise data comparison Activation of SOS: Function selection Delay time: p9351/p9551 Standstill tol.: p9330/p9530 Error in crosswise data comparison SOS Safe Operating Stop Monitoring of the standstill position of the drive Transition time elapsed p9352/p9552 Transition time elapsed p9353/p9553 SS2 Safe Stop 2 Drive is decelerated along the OFF3 ramp Standstill tolerance violated p9330/p9530 STOP D Drive must be decelerated by the higherlevel control system STOP C Drive is decelerated along the OFF3 ramp SBR Safe Acc. Monitor Safe monitoring of acceleration/deceleration Optionally parameterized via p9363/p9563 AND limit value exceeded p9331/p9531 Optionally parameterized via p9363/p9563 AND limit value exceeded p9331/p9531 Activation Delay time elapsed p9351/p9551 Tolerance violated p9348/p9548 STOP A Drive coasts (corresponds to Safe Torque Off ) Tolerance violated p9348/p9548 OR delay time elapsed p9356/p9556 OR shutdown velocity undershot p9360/p9560 STOP B Drive is decelerated along the OFF3 ramp (corresponds to Safe Stop 1 ) Optionally parameterized via p9363/p9563 AND limit value exceeded p9331/p9531 Optionally parameterized via p9363/p9563 AND limit value exceeded p9331/p9531 SLS Safely Limited Speed Monitoring of the current drive velocity Activation of SLS: Function selection Delay time: p9351/p9551 Velocity: p9331[x]/p9531[x] V1.0, ItemID: 48206059 17

3 Safety Integrated Extended Functions Figure 34 Characteristics of the Safety Integrated Extended Functions of SINAMICS S120 (with encoder) part 4 Fehler im kreuzweisen Datenvergleich Fehler im kreuzweisen Datenvergleich SOS oder SLS aktiv oder Hysterese SSM aktiv Antrieb wird an der AUS3 Rampe abgebremst (entspricht Safe Stop 1" Toleranz verletzt p9348/p9548 ODER Verzögerungszeit abgelaufen p9356/p9556 ODER Abschaltgeschwindigkeit unterschritten p9360/p9560 Anzeige der Unterschreitung einer Grenzgeschwindigkeit Aktivierung SLS: Immer aktiv Geschwindigkeit: p9346/p9546 Hysterese: p9347/p9547 PT1Filter p9345/p9545 Antrieb trudelt aus (entspricht Safe Torque Off ) Wird bei Projektierung einer Extended Safety Function automatisch aktiv V1.0, ItemID: 48206059 18

4 Additional Information 4 Additional Information 4.1 Designing the Safety Integrated Functions 4.1.1 Setting the delay times The settings of the delay times must be based on the following aspects: Consideration of mechanical conditions such as maximum axis velocity, involved centrifugal masses, etc. Consideration of involved standards, which, for instance, include required stopping times. Consideration of risk analyses that may have to be performed. Note If, during the deceleration process of an axis with active Safe Acceleration Monitor (SBR) monitoring function, the current velocity falls below the zero line ( undershoot ), the return to the zero line will be assessed as an acceleration in the safety function and the Safety Integrated Function will trigger an error. Therefore, set the tolerance of the Safety Integrated Function accordingly to ensure that the drop in velocity below the zero line can be tolerated by the function. In addition, optimize the axis settings so that the drop of the current velocity below the zero line ( undershoot ) can be kept as small as possible. 4.1.2 Setting the brake ramps Base the settings of the brake ramps for the individual axes on the respective maximum process speed of the machine. This ensures that, using the set brake ramp, the axis comes to a standstill within a defined period of time. 4.1.3 Selecting the appropriate Safety Integrated Function If possible, select the appropriate Safety Integrated Functions for the relevant axes of a machine. Please note the following: Single axes can be directly influenced via active safety functions. Axes within a group of axes (e.g., multiple axis interpolation) should only be influenced by the control system while being monitored, for example, with the aid of a safe monitoring function. This ensures that contour deviation during the deceleration process or damage to the machine can be avoided. This note should be considered particularly for the optional selection of the internal error response of the STOP A/B/C/D Safety Integrated Extended Functions. V1.0, ItemID: 48206059 19

4 Additional Information 4.2 Crosswise data comparison Crosswise data comparison of the Safety Integrated Functions is performed whenever a safety function has been configured. Figure 41 Crosswise data comparison in SINAMICS S120 Channel 1, processor type 1 (control unit) Channel 2, processor type 2 (motor module) 1 2 I/O Failsafe communication Measure ment system Bus 1 Checkback signals Channel 1 computer type 1 Crosswise Drive Shutdown data comparison power section path Channel 2 computer type 2 Checkback signals 2 If the crosswise data comparison detects a discrepancy between the two channels of SINAMICS S120, a STOP F safety fault will be initiated. This function is then used to define the further procedure for processing this fault in the drive. The result is mostly a transition to the STOP A or STOP B safety faults. 4.3 Forced dormant error detection Forced dormant error detection of the shutdown paths is used to detect errors in the software and hardware of the two monitoring channels in time. To meet the requirements of ISO 138491 (2006) for timely error detection, the two shutdown paths have to be tested at least once within a defined time interval to ensure that they function correctly. This must be implemented by the manual or processautomated triggering of forced dormant error detection. 4.3.1 Procedure for Safety Integrated Basic Functions For the Basic Safety Functions of SINAMICS S120, forced dormant error detection is performed by initiating the Safe Torque Off (STO) Safety Integrated Function. A timer (p9659 SI timer for forced dormant error detection) monitors that forced dormant error detection is performed in time. Within the set time, forced dormant error detection of the shutdown paths must be performed at least once. After this time interval has elapsed, a respective warning is output and does not disappear until forced dormant error detection is performed. Each time the Safe Torque Off (STO) Safety Integrated Function is deselected, the timer is reset to the set value. V1.0, ItemID: 48206059 20

4 Additional Information 4.3.2 Procedure for Safety Integrated Extended Functions For the Safety Integrated Extended Functions of SINAMICS S120, forced dormant error detection is performed by initiating a test stop. This test stop tests the two shutdown paths of the Safe Torque Off (STO) Safety Integrated Function. In this process, the drive behavior corresponds to a selection of the Safe Torque Off (STO) Safety Integrated Function with automatic deselection of the function after a configurable period of time. A timer (p9559 SI Motion forced dormant error detection timer (control unit)) monitors that forced dormant error detection is performed in time. Within the set time, forced dormant error detection of the shutdown paths must be performed at least once. After this time interval has elapsed, a respective warning is output and a BICO output (r9723.0 CO/BO: SI Motion driveintegrated diagnostics signals) is set. The warning does not disappear until forced dormant error detection is performed. Forced dormant error detection is triggered via a BICO input (p9705 BI: SI Motion test stop signal source) and acknowledged by canceling this input. In this process, forced dormant error detection does not require PowerOn of the SINAMICS S120 drive system. Note The test stop of the safety functions initiates the Safe Torque Off (STO) Safety Integrated Function. Safe Torque Off (STO) must not have been selected before selecting the test stop. When using blocksize Power Modules, the test stop must be initiated at a closedloop controlled standstill of the axis (speed setpoint = 0, motor supplied with power). Note It is recommended that the test stop be performed directly after the startup of the drive and before enabling the axes. V1.0, ItemID: 48206059 21