LIRA. Architectural Spot and Flood Light INSTALLATION GUIDE

Similar documents
LIRA. Architectural Spot and Flood Light INSTALLATION GUIDE

HL-DL. Direct View Architectural Delineation LED System INSTALLATION GUIDE

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

FL50 RGBW Inner Mixing Architectural Spot and Floodlight

FL200 Monochromatic Architectural Spot and Floodlight

FL200 RGBW Outer-Mixing Architectural Spot and Floodlight

FL200 RGBW Outer-Mixing Architectural Spot and Floodlight

FL100 RGBW Outer-Mixing Architectural Spot and Floodlight

3 RGBW RECESSED LIGHTING MANUAL

SS2 - DIRECT POWER LIGHTING MANUAL

RGBW PATHWAY LIGHTING MANUAL

RGBW MODULAR LIGHTING MANUAL

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

DIRECT POWER LIGHTING MANUAL

ETC Installation Guide

LED PAR56 Order Code: P56-151

CLS LDV-45. CLS Atmosphere LED-panel CLS LDV-45

SCD96 DMX Output Interface. Installation guide

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

MODA COVE INTERIOR RGB PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

RGB Power Batten. User Manual. Order code: EQLED032

Nano Liner Allegro AC XB RGB / DW INSTALLATION GUIDE V1.2

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

Crossfire. User Manual. Order code: EQLED061

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

LED W RGBA User Manual

QD V LED Tape DMX Driver

Metham Aviation Design Limited Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0)

UV Power Flood. User Manual. Order code: EQLED029

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

Vortex. User Manual. Order code: EQLED073

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

MODA COVE INTERIOR DYNAMIC WARM PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

PROJECT INFORMATION FLANGE FINISH LENS S. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

MODA COVE EXTERIOR DYNAMIC WARM

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

AL Dot User guide

MODA COVE INTERIOR RGBW PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Nokeval. FD100 series. User Manual

Blitzer Strobe. User Manual. Order code: EQLED366

MODA COVE EXTERIOR RGBW PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

Satellite INSTALLATION GUIDE

Cove Light AC HO RGB Graze INSTALLATION GUIDE V0.2. Cover: Cove Light AC HO-9 RGB Graze Cove Light AC HO-36 RGB Graze

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

Model 2380 Rack-Mount Kit

MODA COVE INTERIOR DYNAMIC WHITE PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

8000 Series: Installation Supplement R2-1-12

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

Широкий ассортимент оборудования ACME на User Guide. Professional Entertainment Technology

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Allen-Bradley 1397 AC Tachometer Interface Card

Date. Notes. Category Voltage Wattage Color FWHM Beam Angle Mounting Option INCLUDED ACCESSORIES: 1.) Large Tiltable Stand TSL OPTIONAL ACCESSORIES:

Microbar COB System. User Manual. Order code: EQLED137

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Now with Picture Memory

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Blitzer RGB Strobe. User Manual. Order code: EQLED365

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

ETM-2050/ETM-2051 Service Manual

Please read these instructions carefully before installing This will ensure an easy start and a great first customer experience with TS4 installation

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

ColourChaser Touch. Installation Guide

PV Rapid Shutdown device

THE CTB08D LIGHT CONTOLLER

DMX LED Starcloth Systems

A double yoke enables it to be operated in several positions. receiving device and then to others in a continuous "daisy chain" fashion.

Model 2380 Rack-Mount Kit

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

CS2 DMX Distribution Splitter

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Gobo Projector XP 80W

PF LED Profile. User Manual

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

Endura 1Q120 RGBW COB Exterior Fixture

P216 Series Condenser Fan Speed Controller

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

ZF LED Zoom Fresnel. User Manual

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Blue Weapon Laser. User manual UK. Version 1.0

3M Wrist Strap and Ground Monitor 773. User s Guide

Elapsed Timer Control Panel

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

LEDs and precision constant current circuits for long-life applications. DISCONTINUED

PSU Installation and Setup Guide for the VARIO PSU

lumenbeam SPECIFICATION SHEET

KLIK LEDpod XL28 Patented

Operating Manual. DMX Relay Card 3002R

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

User Guide. Control Box. RoscoLED TM.

Spectrum Laser. User manual UK. Version 1.0

Transcription:

LIRA TM Tel: + 1 905 569 6044 Email: info@ IG, LIRA, 17-07-07 Page 1 / 7

Do not attempt to install or use Luminaire until you have read and understand this guide and safety labels. Luminaires must be installed by a qualified professional in accordance with all national and local electrical and construction codes and regulations. Ensure that main power supply is OFF before installing or wiring luminaire(s). Do not exceed specified voltage and current input. Do not use luminaires with a damaged lens, body, or cable. Not heeding cautions may result in a hazardous situation which can cause equipment and property damage, personal injury, or death. CAUTION Do not exceed the specified voltage and current input. Do not exceed the maximum number of specified fixtures in a light run. Doing so will result in a current overload. GVA Luminaires have no serviceable parts. Do not attempt to open the units. Do not hot swap! Ensure power supply is off before connecting or disconnecting fixtures. Do not stare into beam or view directly with optical instruments. Unauthorized feild repairs will void warranty. 1. MOUNTING BRACKET INSTALLATION Use mounting hardware suitable for the mounting surface. Use of innappropriate hardware may result in dismounting of the bracket and can result in equipment damage, injuries, or death. 1.1. Install mounting bracket in desired location using either one or two M6 (OR 1/4in) bolts or screws suitable for the mounting surface. See "MOUNTING HOLE TEMPLATE" to mark holes prior to installation, if necessary. REQUIRED HARDWARE: 1 OR 2 X M6 (OR 1/4in) BOLT OR SCREW MOUNTING HOLE TEMPLATE (1:1 SCALE) 3 x 6.8mm (.27in) 24mm (0.94in) 29.2mm (1.15in) IF USING MOUNTING SURFACE: IF USING LANDSCAPE SPIKE: M6 (OR 1/4in) BOLT OR SCREW (supplied by others; 1 in the center or 1 per slot) LIRA BRACKET THUMB SCREW LIRA BRACKET LIRA LANDSCAPE SPIKE GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www. for additional information. Tel: + 1 905 569 6044 Email: info@ IG, LIRA, 17-07-07 Page 2 / 7

2. FIXTURE & VISOR/SNOOT INSTALLATION 2.1. Install the fixture and visor or snoot accessories (if applicable) using the provided hardware. REQUIRED HARDWARE: 2 x M6 Disclock Washer (supplied) LIRA VISOR OR LIRA SNOOT (optional) M6 DISCLOCK WASHER 2 x M6x8mm Screw OR 2 x M6x10 Screw (supplied) M6 SCREW 3. PDB-ELV CONNECTIONS Ensure that line power is disconnected before making connections to PDB-ELV. 3.1. Make wire connections to PDB-ELV. NOTE: Terminate return DMX output + and - with 120 OHM resistor. AC INPUT 120~277VAC AC OUTPUT 120~277VAC (optional) DMX I/O TERMINAL VDC OUTPUT TERMINAL DMX INPUT (optional) THIS WAY UP WHEN MOUNTING ON VERTICAL SURFACES VDC & (to DMX luminaires or junction box) OPTION A (if connecting multiple PDBs) OPTION B (if connecting only one PDB or last in line of PDBs) (from DMX luminaires or junction box) (to next PDB; becomes DMX input) (from DMX luminaires or junction box) 120 OHM RESISTOR GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www. for additional information. Tel: + 1 905 569 6044 Email: info@ IG, LIRA, 17-07-07 Page 3 / 7

4. DMX FIXTURE CONNECTIONS Ensure power supply is turned OFF before making any connections. Connecting the luminaire while the power is turned ON may result in equipment damage. 4.1. Make connections to junction boxes and to the luminaires. NOTE: LIRA fixtures 12~24VDC power conductors should be connected in parallel. DMX Common to be also connected in parallel. NOTE: DMX I/O must be connected in series. NOTE: Total load shall not exceed power rating of PDB-ELV and should be under 100W to remain Class 2. NOTE: Follow labels & markings on terminal blocks & cables for correct polarity. TYPICAL SYSTEM DIAGRAM: NOTE: Fixture configuration and length of leader cables and jumper cables directly affects the maximum number of fixtures allowed in a single run. LINE VOLTAGE AC INPUT PDB-ELV12/24-100-DMX -ELV+DMX-120~277VAC-IP66 AC OUTPUT CABLE (optional, supplied by others) DMX INPUT CABLE DATA OUTPUT CABLE (optional, supplied by others) DAISY CHAIN SYSTEM FIRST 7C POWER & DMX CABLE (or 2C power cable & 5C DMX cable) LAST 7C POWER & DMX CABLE (or 2C power cable & 5C DMX cable) 5M (16.4FT) LEADER CABLE LIRA LUMINAIRE 5M (16.4FT) LEADER CABLE LIRA LUMINAIRE RADIAL SYSTEM 7C POWER & DMX CABLE (or 2C power cable & 5C DMX cable) 5M (16.4FT) LEADER CABLE LIRA LUMINAIRE GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www. for additional information. Tel: + 1 905 569 6044 Email: info@ IG, LIRA, 17-07-07 Page 4 / 7

4. DMX FIXTURE CONNECTIONS Ensure power supply is turned OFF before making any connections. Connecting the luminaire while the power is turned ON may result in equipment damage. WIRING DIAGRAM: DAISY CHAIN NOTE: Diagram shows 2C power cable & 5C DMX cable option. FIRST LAST TO NEXT LIRA OR TO NEXT LIRA OR WIRING DIAGRAM: RADIAL NOTE: Diagram shows 2C power cable & 5C DMX cable option. GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www. for additional information. Tel: + 1 905 569 6044 Email: info@ IG, LIRA, 17-07-07 Page 5 / 7

4. DMX FIXTURE CONNECTIONS Ensure power supply is turned OFF before making any connections. Connecting the luminaire while the power is turned ON may result in equipment damage. 4.2. Connect Class 2, 12~24VDC output to power conductors of LIRA luminaire : red(+), black(-). Connect DMX I/O to DMX conductors of LIRA luminaire (output optional). NOTE: LIRA Luminaires require 12VDC or 24VDC Class 2 or limited to 25A Power Supply with Class 2 outputs. If PSU is other than Class 2, provisions must be made to create Class 2 outputs. INPUT/OUTPUT RED = +12~24VDC BLACK = -12~24VDC ORANGE = DMX (-) INPUT ORANGE/WHITE = DMX (+) INPUT BLUE = DMX (-) OUTPUT BLUE/WHITE = DMX (+) OUTPUT BROWN/WHITE = DMX COMMON GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www. for additional information. Tel: + 1 905 569 6044 Email: info@ IG, LIRA, 17-07-07 Page 6 / 7

NOTES GVA Lighting Inc. is not responsible for printing or clerical errors. Refer to www. for additional information. Tel: + 1 905 569 6044 Email: info@ IG, LIRA, 17-07-07 Page 7 / 7