Instruction Manual Temp JKT Temperature Meter Series

Similar documents
24-hour Continuous Field Monitors

Instruction Manual ph 5+ ph 6+ Ion 6+ Technology Made Easy...

MULTI- PARAMETER TESTER

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

Instruction Manual. ph 700 ph/mv/ C/ F Bench Meter. Ion 700 ph/mv/ion/ C/ F Bench Meter. Technology Made Easy...

Instruction Manual. CyberScan DO Dissolved Oxygen Meter. Technology Made Easy... 68X Rev. 1 01/04

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

Instruction Manual. αlpha TDS /8 DIN Total Dissolved Solids Controller with Temperature display and Transmitter. 68X rev 0 08/2002

Operation Manual. Hand-held ph/orp/temperature Meter 6010M

Platinum RTD Thermometer MODEL NO

HI HI N HI HI

WalkLAB ph mv/orptemperature

Operation Manual. MODEL ph 630. Microcomputer Based ph&temperature Pocket Meter. ph630

The Economy Conductivity Benchtop Meter

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods

Instruction Manual CON 6/TDS 6. Hand-held Conductivity/TDS Meter 68X Technology Made Easy... Rev.2 01/04

Operation Manual MODEL 3173/3173R. MICROCOMPUTER BASED Conductivity/Salinity/TDS &Temperature BENCH METER 3173/3173R

Instruction Manual. ph 11 & ph 110. Hand-held ph / mv / Temperature / RS 232 Meter 68X Rev. 2-11/03. Technology Made Easy...

HI HI N HI HI

OPERATION MANUAL MODEL TT-LP

Platinum RTD Thermometer MODEL NO

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Instruction Manual CON 400 and CON 410 Waterproof Hand-held Conductivity/TDS Meter

Instruction Manual. PC 700 ph/mv/conductivity/ºc/ºf Bench Meter. Technology Made Easy...

CyberComm Pro Data Acquisition Software Installation & User Guide

Professional Benchtop Conductivity meter BC3020

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8


Bluelab ph Meter TM Instruction Manual

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP

Instruction Manual. ph Monitor ph/mv/ºc meter

Bante 221 Portable ph/orp Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

SoilStik ph Meter PRODUCT MANUAL

Operations Manual EcoSense ph100

Instruction Manual. Single-Input RTD Thermometer (Model )

Temp-360 RTD Data logging Thermometer

Instruction Manual ph 600/610/620 Waterproof Handheld ph Meter ph/mv/ion/ºc/ºf meter Technology Made Easy...

HI HI HI HI Portable Microprocessor Thermistor Thermometers

User Guide. Moisture Meter. Model MO250

Instruction Manual COND 600/610 Waterproof Handheld Conductivity Meter

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Bluelab Combo Meter TM Instruction Manual. combo metertm.

TDS/SALT/TEMP TRACERTM POCKETESTER CODE 1749-KIT. Pool Professional s Meter

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Operation Manual. MODEL ph/ec80. Microcomputer Based ph/condctivity/tds/ Sanility & Temperature Pocket Meter. ph/ec80

Instruction Manual Cond 6+ Conductivity/Temp TDS 6+ TDS/Temp Salt 6+ Salinity/Temp

HI HI HI HI HI HI HI

Cole-Parmer Instrument Company

DIGITAL POCKET HEAT INDEX MONITORS USER S MANUAL

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Operations Manual EcoSense ph100a

DELUXE FAST RESPONSE WATERPROOF DIGITAL STEM THERMOMETER USER S MANUAL

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Barnant Company. Humidity Data Logger MODEL NO YR MIN HOLD MO MAX DAY STORE LOG RECALL PRINT C/ F PRINT SETUP.

DICKSON TC200/TH300 DICKSON. Handheld Temperature and Temperature / RH Indicators. Useful Features. Applications & Product. Specifications.

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English

CO Analyzer. The Value Leader TM

RH/Temperature SD Card Datalogger. Instruction Manual

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Datalogging Hot Wire CFM Anemometer

WEB SITE:

User Guide. ExStik FL700. Fluoride Meter

CyberComm Pro 2.4 Data Acquisition Software Installation & User Guide. CyberScan DO 1500

Datalogging Conductivity/ TDS Meter. Instruction Manual

Cole-Parmer Instrument Company

ph/orp Meter SD Card real-time Datalogger

Light Meter with Bar Graph

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Manual No Revision MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER

User's Guide. ExStik EC400. Conductivity / TDS / Salinity / Temperature Meter MODE HOLD

Tracer TM Salt/EC/TDS PockeTester Code 1749

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

Heavy Duty Psychrometer + IR Thermometer Model HD500

Thermo Scientific Orion Star A214 Benchtop ph/ise Meter. Instruction Sheet

Visible Light SD Card Datalogger

USER MANUAL AD 3000 EC/TDS/Temperature Bench Meter

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

User Guide. ExStik II EC400. Conductivity / TDS / Salinity / Temperature Meter

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

DO Meter Kit. Instruction Manual

VELOCICALC Air Velocity Meter

Model 8702 DP-CALC Micromanometer

HAND-HELD THERMOCOUPLE THERMOMETER SERVICE MANUAL. CATALOG NUMBERS , and , and PROPRIETARY

Torque Meter. Instruction Manual

OPERATING MANUAL. EchoThermJ PROGRAMMABLE, DIGITAL, ELECTRONIC CHILLING/HEATING PLATE MODEL IC25, IC25XR, IC25XT, IC35 and IC35XT

INSTRUCTION MANUAL. Models: H100 Light Meter

DFI 9000 PORTABLE DIGITAL INDICATOR USER S GUIDE

PIECAL 520B & 521B Thermocouple Source Operating Instructions

User's Guide. Heavy Duty Differential Pressure Manometer. Model

EC/TDS/SAL TRACERTM POCKETESTER CODE Conductivity/TDS/Salinity/Temperature/Meter

Model SRV945-BT 24 X 36 Platform Scale App-Enabled Operating and Service Manual Part No.: MAN945-BT_ Page 1 of 16.

Anemometer SD Card Datalogger. Instruction Manual

Heavy Duty Datalogging Light Meter

Dual Moisture Meter Pin / Pinless Moisture Meter

Torque Meter. Instruction Manual

Transcription:

Instruction Manual Temp JKT Temperature Meter Series 68X243615 Technology Made Easy... Rev. 2 11/03

Preface This manual serves to explain the use of the Temp JKT temperature meter. This manual functions in two ways: first, as a step by step guide to help you operate the meter; second, it serves as a handy reference guide. This manual is written to cover as many anticipated applications of the Temp JKT meter as possible. If there are doubts in the use of the Temp JKT meter, do not hesitate to contact the nearest Eutech Instruments Authorized Distributor. Eutech Instruments/ Oakton Instruments will not accept any responsibility for damage or malfunction to the meter caused by improper use of the instrument. The information presented in this manual is subjected to change without notice as improvements are made, and does not represent a commitment on the part of Eutech Instruments Pte Ltd/ Oakton Instruments. Copyright 1999 Eutech Instruments Pte Ltd/ Oakton Instruments Rev 2 11/03.

TABLE OF CONTENTS 1. INTRODUCTION 1 1.1 Introducing the Temp JKT 1 2. GETTING STARTED 2 2.1 Description of Keypad Functions 2 2.2 Description of LCD Annunciators 2 2.3 Inserting & Removing the Rubber Boot 3 2.4 Inserting New Batteries 4 2.5 Battery Replacement 5 2.6 Connecting the Temperature Sensor 5 2.7 Switching the Meter On 5 3. CALIBRATION 6 3.1 Temperature Calibration 6 4. MEASUREMENT 8 4.1 Taking Measurements 8 4.2 Displaying Maximum and Minimum Readings 8 4.3 Holding a Reading 8 4.4 Releasing a Held Reading 8 4.5 Maximum and Minimum Hold Mode 9 5. DISABLE AUTO POWER OFF FEATURE 10 6. PROBE CARE AND MAINTENANCE 11 7. TROUBLESHOOTING 11 8. SPECIFICATIONS 12 9. ACCESSORIES 13 10. WARRANTY 14 11. RETURN OF ITEMS 15

1. INTRODUCTION 1.1 Introducing the Temp JKT Thank you for purchasing the Temp JKT meter. This economical microprocessorbased handheld meter works with type J, type K and type T probes for a wide temperature measurement range: Type J probes (iron-constantan) offer a wide range of 200 to 1000 C / - 328 to 1832 F; use in reducing environments Type K probes (chromel-alumel) offer the widest range of 250 to 1372 C / -418 to 2502 F; use in oxidizing environments Type T probes (copper-constantan) of range of 250 to 400 C / -418 to 752 F; good for ambient and sub-freezing measurements The Temp JKT meter features: Large LCD for clear and easy reading Readings in o C and o F (selectable) Minimum and maximum temperature display Minimum and maximum hold mode Low battery indicator Hold function, freezes measured reading User calibration - offset adjustment Built-in memory backup; calibration and other information remain if battery is disconnected This instruction manual is organized for quick reference with step-by-step procedures that give you thorough review of the various features and meter operations. Included with your meter are a rubber boot, 4 alkaline AAA batteries, an instruction manual and a warranty card. To order different type of thermocouple probes, please refer to Section on Accessories for more information. 1

2. GETTING STARTED 2.1 Description of Keypad Functions Temp JKT meter has seven keys on its splash-proof keypad. These keys include ON / OFF, CAL, HOLD / ENTER, o C/ o F, MAX/ or MIN/ key and J-K-T keys. ON/OFF: Powers meter on and shuts the unit off. Meter directly enters measurement mode when you turn it on. CAL: Allows temperature calibration of the meter. HOLD/ENTER: Freezes the measured reading; confirm calibration value. MAX/ (UP) or MIN/ (DOWN): Momentarily displays meter s maximum and minimum temperature; enter maximum or minimum hold mode; scroll up and down in calibration mode. o C/ o F: Switches between o C and o F in measurement mode. J-K-T: Switches between J, K and T thermocouple measurement mode. Figure 1: K d 2.2 Description of LCD Annunciators The EcoScan Temp JKT meter has a large custom LCD that consists of 4-digit segments and operation annunciators for o C and o F. Other indicators include MIN, MAX, HO (when the HOLD function is activated), LO (low battery condition) and J / K / T. JKT HO LO MAX MIN ph % o o C F m pp mv Figure 2: Full segment LCD 2

2.3 Inserting & Removing the Rubber Boot 1. To remove meter from rubber boot, push out from the bottom edges of meter until it is completely out of boot. Ensure that the connector of temperature sensor is not connected. 2. To insert meter into rubber boot, slide in from the top of meter before pushing the bottom edges of meter down to set it into position. Lift up the stand at the back of meter for bench top applications if necessary. Figure 3: Inserting meter into the rubber boot 3

2.4 Inserting New Batteries The battery compartment is found at the back of instrument. To open the battery compartment, push in the direction of arrow and lift up the cover. Note the polarity of battery before inserting into position. After replacement, place cover back and press down until it locks tight. Figure 4: Battery compartment at the back of the meter 4

2.5 Battery Replacement A LO annunciator in the LCD alerts you when battery power is running low. Replace with the same type as recommended by the manufacturer. K LO o C Figure 5: Low battery indicator Caution: Power off the meter when changing battery. 2.6 Connecting the Temperature Sensor Insert the 2-pin mini connector plug of the temperature sensor into the connector socket on the side of the meter. NOTE: The negative pin is larger than the positive pin, be sure to properly align the pins. Unplug the sensor when not in use. Figure 6: Connecting the temperature sensor 2.7 Switching the Meter On 1. Press ON/OFF key to power up your meter. All the LCD segments display momentarily as the meter performs a self-diagnostic test, per shown in section 2.2. The LCD then switches into measurement mode. Figure 7: "Open" i t 2. The LCD displays open if the temperature sensor is faulty, or there is an open circuit. Please refer to section on Troubleshooting if in doubt. 5

3. CALIBRATION 3.1 Temperature Calibration The temperature sensor included with your meter is factory calibrated. Over time, the temperature calibration may drift and the probe requires re-calibration. The Temp JKT meter allows you to have a 1-point calibration as fine adjustment by changing its offset value. This is useful if you replace the probe. If you replace the probe, you should recalibrate. 1. First connect the temperature probe to the meter. Press ON/OFF key to power up the meter and wait for meter to enter measurement mode. 2. Dip the probe in a constant temperature bath, or in liquid whose temperature can be checked with an accurate thermometer. For best accuracy, place the probe and thermometer in a constant temperature bath. 3. Wait for readings to stabilise. 4. To enter temperature calibration mode, press and hold CAL key for 5 seconds before release. The LCD shows CA momentarily and a value flashes. 5. Press MAX/ or MIN/ key to adjust the displayed value until it matches the correct temperature. The MAX/ or MIN/ key will scroll to the maximum allowable value. NOTE: The maximum adjustments allowed for the following meter series from factory default are: EcoScan JKT Temperature meters = ±10 C EcoScan 4/5/6 Temperature meters = ±5 C 6

6. Press ENTER key to confirm calibration. 7. The LCD displays CO momentarily, and the meter then reverts to measurement mode. See figure below. Press down CAL key for 5 seconds before release CAL C C From measurement mode C HOLD ENTER C Figure 8: Temperature calibration 7

4. MEASUREMENT 4.1 Taking Measurements 1. Power on the meter. The meter automatically enters Temperature mode. The J, K or T annunciator will display, depending on what probe type was selected the last time the meter was used. The o C or o F annunciator display in your LCD indicate which mode you are taking measurements in. J o o C F Figure 10: J/K/T and temperature annunciators 2. Press the J-K-T key to toggle between type J, K or T mode, until the mode matches probe type selected. Note reading. 3. Press the C/ F key to toggle between each measurement mode. 4.2 Displaying Maximum and Minimum Readings The Temp JKT meter can momentarily display the maximum and minimum temperature measured since you switched the meter on. Simply press MAX/ or MIN/ key. The MAX or MIN annunciator displays in the LCD and the maximum or minimum temperature momentarily displays. Meter then returns to measurement mode. K MAX o C Figure 11: Viewing the maximum & minimum value 4.3 Holding a Reading To freeze or hold your reading, press HOLD key once. The LCD displays HO annunciator to indicate the HOLD function is activated. K HO o F 4.4 Releasing a Held Reading Figure 12: HOLD i t Press HOLD key again to deactivate HOLD function or to release your frozen reading. The meter returns to measurement mode, and the HO annunciator disappears from the LCD. 8

4.5 Maximum and Minimum Hold Mode With the Maximum and Minimum Hold mode, the Temp JKT meter can be used as a maximum registering (or minimum registering) thermometer. The meter displays the lowest or highest temperature measured since entering the Maximum or Minimum Hold mode. 1. Power on the meter. The meter automatically enters temperature mode. Use C/ F key to switch between Celcius and Fahrenheit reading if desired. 2. Press HOLD key. The reading freezes and the annunciator HO displays in the LCD. 3. Press MAX/ or MIN/ key. Meter enters the Maximum or Minimum Hold mode. HO and MAX or MIN annunciator displays in the LCD. J HO MIN o F Figure 13: Maximum & minimum HOLD mode Meter will now continuously display the lowest or highest temperature measured since you entered this mode. It will update the display when new highs or lows are reached. Press HOLD key again to leave MIN/MAX Hold mode and meter returns to its measurement mode. 9

5. DISABLE AUTO POWER OFF FEATURE By default this meter will auto power-off 17 minutes after last key operation. This is to conserve battery power. The auto power-off feature can be disabled in situation where longer periods of monitoring are desired. NOTE: The meter switches back to auto power-off mode as soon as it is turned off. Procedure: 1. With meter off, press down ON/OFF and MIN/ keys together. 2. Release ON/OFF key first and wait for 2 seconds before releasing MIN/ key. 3. The meter goes through the power-up sequence before coming to measurement mode. 4. The LO indicator will blink, indicating that the auto power-off feature is disabled. The "LO" indicator will blink, indicating that the auto power-off feature is disabled NOTE: When battery is low, the LO indicator will blink faster at every 1 second. Otherwise, it blinks every 2 seconds. Once the meter is switched off and subsequently switched on again, the auto power-off feature will be enabled. NOTE: Under default operation (when auto power-off feature is enabled), the appearance of LO indicator permanently on the display means the battery power is low. Once a new battery is installed, the LO indicator will disappear LO C 10

6. PROBE CARE AND MAINTENANCE For best results, always clean the temperature probe with clean tissue paper after measurement to keep the probe in good working condition. Wash the probe thoroughly with tap water if necessary to wash off any residue. Should there be any thin oil film sticking on the probe, wash with mild detergent or soap and warm water. Rinse probe thoroughly under running water. Blot it dry and clean off with clean tissue. To remove the probe, simply hold firmly onto the probe s plastic holder and pull the connector out of the meter s socket. Store both the probe and meter into its original packaging when not in use. 7. TROUBLESHOOTING Problem Cause Solution Power on but no display open display on LCD Ur or Or display on LCD LO annunicator in the LCD Unstable reading a) Batteries not in place. a) Insert batteries. b) Re-insert batteries in correct polarity. a) Probe not connected a) Make sure probe is firmly connected. a) Measurement over (Or) or Under (Ur) range a) Ensure temperature taken is within meter s specification. a) Low battery a) Replace batteries with fresh ones. a) Electrode not deep enough in sample b) Dirty probe c) Broken probe d) External noises or induction caused by nearby electrical motor a) Place probe deeper in sample. b) Clean probe. c) Replace electrode. d) Remove or switch off interfering motor. Slow response a) Dirty probe a) Clean probe 11

8. SPECIFICATIONS Temperature Range Type J Type K Type T Resolution t<-99.0 C -99.9 C<t<299.9 C t>299.9 C Accuracy t<-99.9 C t>-99.9 C Offset Adjustment Auto Power-Off Hold Function Display Low Battery Indicator Input Power Requirement Battery Life -200 to 1000 C (-328 to 1832 F) -250 to 1372 C (-418 to 2502 F) -250 to 400 C (-418 to 752 F) 1 C (1 F) 0.1 C (0.1 F) 1 C (1 F) ± 0.25% of reading + 1 C (2 F) ±0.2% of reading + 0.5 C (0.9 F) ±10 C (±18 F) 17 minutes after last key-press Yes Custom LCD Yes 2-pin ANSI mini connector 4 AAA Batteries >200 hours Operating Temperature -10 to +50 C Dimension / Weight Meter: 14 x 7 x 3.5 cm / 200 g Boxed: 24 x 17 x 8 cm / 550 g 12

9. ACCESSORIES Replacement Meter and Meter accessories Item Eutech Instruments Ordering Code Oakton Instruments Ordering Code Temp JKT meter only EC-TEMPJKT 35627-00 General purpose probe (immersion into liquids), type J EC- TPGLPJ-01M 08517-55 Penetration probe (meat, semi-soft materials), type J Surface probe (direct contact on hot surface), type J Clip-on probe (surface contacts electronics), type J General purpose probe (immersion into liquids), type K Penetration probe (meat, semi-soft materials), type K Surface probe (direct contact on hot surface), type K Clip-on probe (surface contacts electronics), type K EC-TPPENJ-01M 08517-65 EC-TPSURJ-01M 08517-60 EC-TPCLPJ-01M 08469-00 EC-TPGLPK-01M 08516-55 EC-TPPENK-01M 08516-65 EC-TPSURK-01M 08516-60 EC-TPCLPK-01M 08469-02 Replacement Boot ~ 35627-80 Replacement AAA Batteries ~ 09376-00 13

10. WARRANTY This meter is supplied with a warranty against significant deviations in material and workmanship for a period of THREE years from date of purchase whereas probe with a SIX-month warranty. If repair or adjustment is necessary and has not been the result of abuse or misuse within the designated period, please return freight pre-paid and correction will be made without charge. Eutech Instruments/ Oakton Instruments will determine if the product problem is due to deviations or customer misuse. Out of warranty products will be repaired on a charged basis. Exclusions The warranty on your instrument shall not apply to defects resulting from: Improper or inadequate maintenance by customer Unauthorized modification or misuse Operation outside of the environment specifications of the products 14

11. RETURN OF ITEMS Authorization must be obtained from our Customer Service Department or authorized distributor before returning items for any reason. A Return Goods Authorization (RGA) form is available through our authorized distributor. Please include data regarding the reason the items are to be returned. For your protection, items must be carefully packed to prevent damage in shipment and insured against possible damage or loss. Eutech Instruments/ Oakton Instruments will not be responsible for damage resulting from careless or insufficient packing. A restocking charge will be made on all unauthorized returns. NOTE: Eutech Instruments Pte Ltd/ Oakton Instruments reserves the right to make improvements in design, construction, and appearance of products without notice. 15

NOTES

For more information on Eutech Instruments/ Oakton Instruments products, contact your nearest distributor or visit our website listed below: Oakton Instruments P.O Box 5136, Vernon Hills, IL 60061, USA Tel (in U.S.): 888-462-5866 Tel (outside U.S.) 1-847-549-7600 E:mail: info@4oakton.com Fax: (1) 847-247-2984 www.4oakton.com Eutech Instruments Pte Ltd. Blk 55, Ayer Rajah Crescent, #04-16/24 Singapore 139949 Tel: (65) 6778 6876 Fax: (65) 6773 0836 E-mail:: marketing@eutechinst.com Web-site: www.eutechinst.com Distributed by: