How to Switch from NT to NS

Similar documents
Device/PLC Connection Manuals

Device/PLC Connection Manuals

Automation Systems GENERAL CATALOGUE 2004

Cat.No. V083-E1-03. NS-Series Programmable Terminals SETUP MANUAL

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of CVM1/CV Series and C500 I/O series

PRODUCT OVERVIEW CPM2A

Providing What's Needed in Programmable Terminals The Simple Design and Easy Operation That Users Need. Reduced TCO* throughout Onsite System Construc

NT Series CSM_NT_series_DS_E_2_5

Cat. No. V072-E1-02. NS-Series Programmable Terminals SETUP MANUAL

onlinecomponents.com

CX-Server PLC Tools. Release 3.1

CX-Programmer Ver.9. FA Integrated Tool Package CX-One

The CD-ROM of CX-Programmer has User's Manual of the PDF file. Please read the 'Notice' and the 'Precutions' in the User's Manual before using CX-

NS7. Programmable Touch screen Terminals. General. Performance Data (Max. Values)

CPM1A MICRO PROGRAMMABLE CONTROLLERS

OMRON Corporation CS/CJ Series PLC Ladder Monitor. Operation Manual

Smallest, Most Powerful Solution for Advanced Production Systems

NT31, NT31C, NT631, and NT631C Programmable Terminals Reference Manual

OMRON Corporation PLC SYSMAC C Series Connection

PRODUCT OVERVIEW CQM1H

Power and Expansion Selection

Cat.No. V015-E1-1. NT-series. Host Interface Unit Direct Connection OPERATION MANUAL

PNSPO!!!!!! NB-series Programmable Terminals SETUP MANUAL. Cat.No. V107-E1-01

Programmable Terminals

High Function Touch Screens - NT21 / NT31 / NT631

CX-Server Runtime User Manual

Cat. No. V074-E1-07. NS-Series NS-NSDC1-V6. NS-Designer OPERATION MANUAL

CPU Units with 20 I/O points

SYSMAC CJ-series CJ1M CPU Units (with Ethernet function)

WS02-PSTC1-E CX-Protocol Ver. 1.6 OPERATION MANUAL

Industrial Communication

Note: Do not use this document to operate the Unit. OMRON Corporation. CJ1M-CPU22/23 Models with built-in I/O

Data area memory capacity. 32K words DM: 32K words EM: None. 0.1 μs

Program capacity. EM: 32K words x 3 banks) 0.04 µs CJ1G-CPU44H 30K steps 64K words CJ1G-CPU43H modules, up to 2 20K steps CJ1G-CPU42H

Appendix 3 Using NS-AL002 Converters

CX-Programmer Ver.8. FA Integrated Tool Package CX-One

onlinecomponents.com

J Features. Data memory capacity (See note.) 60K steps 128K words 0.04 µs. 64K words

Cat.No. V034-E1-5 NT30/30C. Programmable Terminal OPERATION MANUAL

USB-Serial Conversion Cable User's Manual

SECTION 4 Host Link Communications

Technical Explanation for Programmable Terminals

Cat. No. W445-E1-02 SYSMAC CX-Integrator Ver. 1.1 OPERATION MANUAL

PRODUCT OVERVIEW. DeviceNet Communications Module for NT31/NT631. DeviceNet

Replacement Guide From C200H to CJ2

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Programmable Controllers CPM1A series and CPM2A series.

Packed with ideal functions for machine control.

So clear you can feel it. See the vividness. New. Matsushita Electric Works, Ltd. Programmable Display GT01 GT01R GT05 GT11 GT21C GT32

NT30/30C Programmable Terminal

Cat. No. V063-E1-02. NT631 and NT631C. Programmable Terminals SETUP MANUAL

Cat. No. W344-E1-11 SYSMAC WS02-PSTC1-E. CX-Protocol Ver. 1.9 OPERATION MANUAL

NS-Runtime Software USER S MANUAL

Electronic Catalog Operator Interface Terminals

CS1D Duplex System. Select from a Wide Range of Redundant Systems Easily Achieve Highly Reliable Systems

SETUP MANUAL. Programmable Terminals. NS-Series

Device/PLC Connection Manuals

Introduction. Summary. Otasuke GP-EX! Introduction Summary. Intro-21. Development Environment Intro-4. Procedures of Creating New Screen

Replacement Guide From C200HS to CS1

General Precautions The user must operate each product according to the performance specifications described in the operation manuals.

Cat. No. V062-E1-03. NT31 and NT31C. Programmable Terminals SETUP MANUAL

Cat. No. W344-E1-16. SYSMAC CX-Protocol Ver. 1.9 OPERATION MANUAL

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

CPU Unit. (Temperature control) (Position control) (Speed control)

Converts the wiring of the 32-point I/O Unit connector into a terminal block, simplifying wiring and reducing the amount of wiring within the panel.

Appendix G. CJ1W-CIF11 RS-422A Converter

Solution Selection Guide

CJ1 Series PLC. The new, compact CJ1 PLC is now available from stock.

C200H Replacement Guide. From C200H to CJ2

USER'S MANUAL MODEL 3G3MV-PDRT2 MODEL 3G3RV-PDRT2. (For SYSDRIVE 3G3MV Multi-function Compact Inverters)

CS1 Series Programmable Controller

CJ Series General-purpose Serial Connection Guide OMRON Corporation V500-R2 Series Fixed Laser-Type Barcode Reader

CX-Programmer User Manual

OMRON SYSMAC - System C200H Alpha CPUs

Cat. No. V068-E1-01 NT21. Programmable Terminal. Setup Manual

Better SYSMAC Compatibility and Easier-to-use Support Software NT631/NT31 Version 2 Series

CX-Programmer Ver.9 CSM_CX-Programmer_DS_E_11_5

CPU Units with 20 I/O points

C200HX/HG/HE Replacement Guide. From C200HX/HG/HE to CJ2

Replacement Guide From C200HX/HG/HE to CS1

CV/CVM1 Replacement Guide. From CV/CVM1 to CJ2

CPM2C Micro Controller

Programmable Controllers CJ1

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

NT620S/620C Programmable Terminals Operation Manual

NT-series Programmable Terminal Operation Manual

NT20S Programmable Terminal OPERATION MANUAL

SETUP MANUAL. Programmable Terminals. NS-Series

CV/CVM1 Replacement Guide. From CV/CVM1 to CS1

Screen Data Adjustment Manual

Programmable Controller CS1D Duplex System

Operation Manual SFC Programming

CS1 Series, C200HX/HG/HE, C200HS DeviceNet (CompoBus/D)

Table of Contents. Chapter 1 Overview and Installation of CX-One. Chapter 2 Example of PLC System Construction by CX-One

Before using this product, you must read Introduction and Safety Cautions.

Programmable Controller NSJ Series, NSJ

New Products Programmable Slaves SYSMAC CPM2C CPU Units with CompoBus/S Master Functions Waterproof Terminals Sensor Terminals Remote I/O Modules

Safety Precautions. Copyright / Trademarks

Cat. No. W464-E1-06. SYSMAC CXONE-AL_C-V4/ CXONE-AL_D-V4 CS/CJ/CP/NSJ Series. CX-Integrator Ver. 2 OPERATION MANUAL

Connection Guide (RS-232C)

Max. I/O units. consumption

Transcription:

How to Switch from NT to NS April, 2005 1

Revision History Revision Revision Date Revised Page, Description Code -1A December 10, 2004 Newly created. -1B April 15,2005 Translate in English and updated 2

Intended Reader This document is intended for NT series users who are planning to replace NT series by NS series. Recommended NT models, connection topology, and the method to switch display shall be provided in this document. Table of Contents Chapter 1 Differences between NT series and NS series (from hardware point of view) 1.1 Product line of Omron indicators 3 1.2 Recommended NS models for NT users 4 1.3 External view (rear view) 5 1.4 Connection topology 7 1.5 Connectable PLC 8 1.6 Connection cable 10 Chapter 2 Procedure for display conversion from NT series to NS series (from software point of view) 2.1 Procedure flowchart 11 2.2 Required operation after display conversion 12 2.3 Inconvertible functions and countermeasures 15 Appendix APPENDIX 1: Flow chart for conversion from NT- to NS-series. APPENDIX 2: Panel attachments for NT to NS conversion. APPENDIX 3: NT-series Screen Data Conversion to NS. APPENDIX 4: NT31C/631C conversion rules of NT31C conversion support tool. 3

1. Differences between NT series and NS series (from the viewpoint of hardware) 1.1 Line of Omron indicators (as of September, 2004) NT series NS series Note) Please see NS -series catalogue for more information. 4

1.2 Recommended NS models for NT users NT600M NT600G NT610C NT30/C NT610G NT611G NT625C NT31/C NT612G NT600S NT631/C NT620C NT620S Replacing by NS8 Replacing by NS12 Replacing by NS5 *For NT600M, NT600G, NT610G, NT611G, and NT612G users Recommended NS model: NS8 Panel cut: NS8 is smaller than the above NT series. A special attachment (NS8-ATT02) is available to adjust the size. Others: Since the power supply for NS8 supports AC100V, please prepare DC24V power supply. *For NT600S, NT620C, and NT620S users Recommended NS model: NS8 Panel cut: NS8 is smaller than the above NT series. A special attachment (NS8-ATT02) is available to adjust the size. *For NT610C, NT625C, and NT631/C users Recommended NS model: NS10, NS12 Panel cut: NS10 and NS12 are smaller than the above NT series. A special attachment NS12-ATT01 is available to adjust the size. *For NT30/C and NT31/C users Recommended NS model: NS5 Panel cut: The existing panel is available. See APPENDIX 1: Flow chart for conversion from NT- to NS-series. See APPENDIX 2: Panel attachments for NT to NS conversion. 5

1.3 External Views of NT and NS (Rear View) Expansion I/F NT31/C (RV) connector NT631/C (RV) RS-422A Expansion I/F connector PRI NTE PORT PORTA PS(DC24V) RS-232C port Printer port RS-232C/RS422A common port PS(DC24V) PRINTERPORT PORTA Printer port RS-232C port NS5 (RV) NS8 (RV) PORTB PORTA SLAVE PORTB PORTA HOST SLAVE NS12 (RV) Expansion I/F PORTB PORTA HOST SLAVE USB USB slave Ethernet RS-232C serial port 6

This section describes each port mounted on NT or (and) NS. *RS-232C serial port Both NT and NS are equipped with one or two RS -232C serial port(s). A bar-code reader can be connected via this port. Bar-code reader V520-RH21-6 is recommended. Although the command configuration of NT is different from that of NS, the memory link is also available via this port. The Omron temperature controller that has an RS-485 communication port and supports CompoWay/F can be connected to an NS via the RS-232C port. In this case, an RS-422A adapter is required. *Printer port/usb host port All NT series can be connected to a printer via the printer port. This port is compliant with Sentronics interface. All NS series except NS5 can be connected to a printer via the USB host port. *Expansion bus I/F NS12, 10, and 8 are equipped with an expansion bus I/F. A video input unit (NS-CA001) can be connected via this interface. Moving images of a camcorder or picture images of a visual sensor can be output via this interface. Furthermore, the screen display of a personal computer can be also output to an NS via this interface. The Controller Link I/F unit(ns -CLK21) can be connected to NS 12 or 10. It cannot be connected to NS8. 7

1.4 Connection topology RS232C <PT:PLC=1:1> NT/NS series Cable length NT: up to 15 m NS: up to 15m RS-232C RS422A <PT:PLC=N:1> NT/NS series RS-422A Cable length NT: up to 500m *Since NT has an RS422A port, direct connection is also available. NS: up to 500m *An RS-232C/422A conversion unit (NS-AL002) allows NS to use up to 500m of cable. When using CJ1W-CIF11, the total cable length is up to 50m. RS232C two ports <PT:PLC=1:2> SerialA SerialB Cable length NT: This topology is not available for NT. NS: 15m each Available combination: NT link 1:1+NT link 1:1 NT link 1:1+NT link 1:N NT link1:n+nt link 1:N NS series Cable length NT: This method is not available for NT. NS: Network devices such as Ethernet un its are additionally required (Complying with IEEE802.3). ETHERNE 8

1.5 Available PLCs (as of September 2004) CPU unit/nt link 1:1 Model Specification PLC model CQM1-CPU41-V1/CPU42-V1/CPU43-V1/CPU44-V1 CQM1H-CPU21/CPU51/CPU61 CPM1-10/20CDR- +CPM1-CIF01 CPM1A-10/20/30/40CD - +CPM1-CIF01 Equipped with a 9-pin connector for RS -232C. Connected to the peripheral port. C series CQM1 C series CQM1H C series CPM1 C series CPM1A CPM2A-30/40/60CD - +CPM1-CIF01 Connected to the RS-232C C series CPM2A port or peripheral port. CPM2C-10/20-1 Equipped with a 9-pin C series CPM2C C200HS -CPU21/CPU23/CPU31/CPU33 C200HE -CPU32(-Z) 2/CPU42(-Z) C200HG-CPU33(-Z) 2/CPU43(-Z)/CPU53(-Z) 2/CPU63(-Z) C200HX -CPU34(-Z) 2/CPU44(-Z)/CPU54(-Z) 2/CPU64(-Z)/CPU65-Z/CPU85 -Z CV500/1000/2000-CPU01-V1 CVM1-CPU01-V2/CPU11-V2/CPU21-V2 connector for RS -232C. Equipped with a connector for RS-232C (Switch type/9-pin type) C series C200HS C series C200HE(-Z) C series C200HG(-Z) C series C200HX(-Z) CVM1/CV series CV500/1000/2000H CVM1 1 The CPU uses a conversion cable (CPM2C-CN111 or CS1W -CN114/118), RS -232C adapter (CPM1-CIF01), or RS-422A adapter(cpm1-cif11) for conversion. 2 Any of the communication boards (C200HW-COM02/COM04/COM05/COM06(-V1)) is required. CPU unit/nt link 1:N Model Specification PLC model CS1G-CPU42H/CPU43H/CPU44H/CPU45H CS1H-CPU63H/CPU64H/CPU65H/CPU66H/CPU67H CS1D-CPU65H/CPU67H CJ1G-CPU42H/CPU43H/CPU44H/CPU45H 1 CJ1H-CPU65H/CPU66H 1 CJ1M-CPU11/CPU12/CPU13/CPU21/CPU22/CPU23 1 CJ1M-CPU11/CPU12/CPU13 ETN CQM1H-CPU61/51 serial communication board CQM1H-SCB41 C200HE -CPU32(-Z) 2/CPU42(-Z) C200HG-CPU33(-Z) 2/CPU43(-Z)/CPU53(-Z) 2/CPU63(-Z) C200HX -CPU34(-Z) 2/CPU44(-Z)/CPU54(-Z) 2 /CPU64(-Z)/CP U65-Z/CPU85-Z Equipped with a 9-pin connector for RS -232C CS series CS1G CS series CS1H CS series CS1D CJ series CJ1G CJ series CJ1H CJ series CJ1M C series CQM1H C series C200HE(-Z) C series C200HG(-Z) C series C200HX(-Z) 1 The CPU can be connected to serial communication unit CJ1W-SCU21/SCU41. 2 Any of the communication boards (C200HW-COM02/COM04/COM05/COM06(-V1)) is required. CPU unit/host link 9

Model Specification PLC model CPM 1-10CDR/20CDR- /CPM1A-10CD/20CD/30CD /40CD - Either RS-232C adapter or RS-422A adapter can be connected to the peripheral port. C series CPM1 CPM2A-30CD/40CD/60CD - Equipped with a 9-pin C series CPM2A connector for RS -232C CPM2C-10/20 - The communication connector C series CPM2C CQM1-CPU21/CPU41-V1/CPU42 -V1/CPU43-V1 /CPU44 -V1 can be used as either peripheral port or RS-232C port. 2 Equipped with a 9-pin connector for RS -232C C series CQM1 CQM1H-CPU11/CPU21/CPU51/CPU61 Equipped with a 9-pin C series CQM1H C200HS -CPU21/CPU23/CPU31/CPU33 C200HE -CPU32(-Z) /CPU42(-Z) C200HG-CPU33(-Z) /CPU43(-Z)/CPU53(-Z) 1 /CPU63(-Z) C200HX -CPU34(-Z) /CPU44(-Z)/CPU54(-Z) 1 /CPU64(-Z)/CPU65-Z/CPU85-Z CJ1M-CPU11/CPU12/CPU13/CPU21/CPU22/CPU23 1 CJ1M-CPU11/CPU12/CPU13 ETN CS1G-CPU42(-V1)/ CPU43(-V1)/CPU44(-V1)/CPU45(-V1) CS1H-CPU63(-V1)/CPU64(-V1)/CPU65(-V1)/CPU66(-V1) /CPU67(-V1) CV500-CPU01-V1/CV1000-CPU01-V1 /CV2000-CPU01-V1/CVM1-CPU01-V2/CPU11-V2 /CPU21 -V2 connector for RS -232C 3 Equipped with a connector for RS-232C (switch type/9-pin type) Equipped with a 9-pin connector for RS -232C Equipped with a 9-pin connector for RS -232C Equipped with a connector for RS-232C (switch type/9-pin type) C series C200HS C series C200HE(-Z) C series C200HG(-Z) C series C200HX(-Z) CJ series CJ1M CS series CS1G CS series CS1H CVM1/CV series CV500/1000/2000 CVM1 1 Any of the communication boards (C200HW-COM02/COM04/COM05/COM06(-V1)) is required. 2 Conversion cable CPM2C-CN111 can be used for branching. The communication connector can be used as a single peripheral port or RS-232C port via conversion cable CS1W -CN114/118. 3 CQM1H-CPU11 has a peripheral port only. 10

1.6 Communication cable RS-232C RS-422A Same The shape of terminals on the terminal block differs between NT and NS. NT631/C NT- L001 NS-AL002 CJ1W- CIF11 Fork Round-shaped crimping terminal M3 or M3.5. Fork Round-shaped crimping terminal M3 (M3.5 is not available)nt-al001: Isolated between RS232C and RS422A. NS-AL002: not isolated between RS232C and RS422A. Bar-shaped crimping terminal NT-AL001 on the RS-232C side is the same. NT31/31C has no 25-pin connector. A terminal block is required. Tool connection Bar-code connection 5V PS for RS-232C port Same Same NT31/631/625 C: Port A only. 250mA (max.) NS :Port A and B. 250mA in total (max.) 11

Chapter 2 Procedure for display conversion from NT series to NS series (from the viewpoint of software) 2.1 Procedure flowchart NT 31C_631C conversion support tool that came with NS-Designer allows users to convert the NT display to NS display. See the following procedure flowchart. Pre-conversion data NT31C -V2 or NT631C-V2 Yes No Convert your data to NT31C-V2 or NT631C -V2 by using version 4 of NT support tool. Change the extension of your file to mm and save the file by using version 4 of NT support tool. Click File to select Save As command. Choose Conversion Start NT31C_631C conversion support tool. Specify the pre-conversion file (the data with.mmi extension.) and the destination to save the converted file. Then, click Execute Conversion. Memory Map Image File (.mmi ) as the file type. See Note 1. Converted data Pre-conversion file: NT31C -V2 (extension is.mmi) Converted file: NS5(extension is.ipp) (Version 5 of NS-Designer) Pre-conversion file: NT631C-V2 (extension is.mmi) Converted file: NS10 (extension is.ipp) (Version 2 of NS-Designer) Adjusting the display Use NS-Designer to change the size or the layout of the display. For more details, see 2.2 Required operation after display conversion. Note1) Memory map image file (with.mmi as its extension) is a file type in which display data is compressed and the information (such as grouping information, grid setting information)used only on the support tool is deleted. See APPENDIX 3: NT-series Screen Data Conversion to NS. 12

2.2 Required operation after display conversion Modification of display size and touch switch mesh Display size Touch switch mesh NT600M Change the number of dots in height from 400 to 480. Change the number of dots in height from 50 to 20. Change the number of dots in height from 400 to 480. Change the number of dots in height from 50 to 20. Not required. Not required. Not required. Not required. Change the number of dots in height from 400 to 480. Change the number of dots in height from 25 to 20. Not required. Not required. Not required. Not required. Not required. Not required. Note) When modifying the display size of NT600M, NT600S or NT620S, the position coordinate of each object will be directly converted. Therefore, the objects on NT600M, NT600S, or NT620S will be allocated within 400 dots at the top portion of the display. Additionally, there will be 80 dots of space at the bottom of the display. Note) Modification of touch switch mesh will cause displacement of touch switch objects. System area allocation After converting the display, the start channel of the PT status control area will be set in the system memory $SW. Since $BO (NS internal memory) is set in $WB, a random address will be used for setting. When using NS series, the system memory can be allocated to the NS int ernal memory as well as the PLC area. PT status control area System memory $SW PT status notification area NT Setup is required. (Default address is $B0) NS Additionally, the structure of the system area is different. Therefore, when referring to the information in the system area from a ladder program, the ladder program must be modified (e.g. window control). 13

Modification of objects Some functions may need to be modified after conversion. The following table shows the places that need to be modified after conversion: Modification part Touch switches for switching display and inputting control code Lamp Alarm Mark data (if it is used in the character string) Required operation They will be converted to a command button transparent)+an ON/OFF button. If there is no need to set any lamp address, delete the control flag setting for the command button. Additionally, delete the ON/OFF button after copying the label of the ON/OFF button to the command button (operation will not be affected even as it is). It will be converted as its ON/OFF button control flag is in input disable status. If there is no need to change the label color or contents based on the bit ON/OFF status, then use the bit lampas a substitute (operation will not be affected even as it is). It will be converted to Bitmem.csv. Import the file by the alarm/event setting. Modify the other display and switch display setting. The mark data will be covered like this: <!FFFF>. Change it to a character string or bitmap. Image lamp Library lamp Character string indirect specification Fixed character For version 5 and newer versions: Image data will be converted to a BMP file. It will be converted to two bit lamps to display ON and OFF. Set the converted file in shape specification. The library data will be converted to a VEC file. It will be converted to two objects. Change the setting in shape specification to integrate them into one bit lamp. The default value of the character string memory table will be converted to a StrTabl.txt. Change the data type of the table number that will be display by the PLC from BCD to BIN. Format each character if necessary. 14

Reference 1 Link between object and host NT series ON/OFF button Default Address 0000.00 The object will refer to the memory table. (Memory table entry No.) Numerical value, character string, bit-memory memory table, and memory table will refer to the host. NS series ON/OFF button There is no concept of memory table. The functional object will refer to the host. (00000.00) <Reference 2> Host and communication address NT series Only one host can be connected. Therefore, there is no concept of communication host. NS series The following host connection topologies are available: 1. Two serial ports 2. One Ethernet port 3. Controller Link I/F unit (optional unit) The format for addressing is as follows: Host name: area name+ address. e.g. SerialA: DM00000 15

2.3 Inconvertible functions and countermeasures The functions listed below cannot be converted by using NT31C_631C conversion support tool. Inconvertible function Temporary input by using user-created numeric keypad. Percent(%) display for a graph The number of points to be indicated for a broken-line 320 points to 256 points Discontinuous address setting for the broken-line monitor address I/O comment Alarm list Image library display Alarm list Occurred alarm display Alarm registration (bit memory table) Bit memory table Switch screen Numerical value, character string memory table initialization Operation table Image lamp Display attribution History Display attribution Back light ON/blink Display attribution Countermeasure For version 5 and older versions: Use the system numeric keypad. For version 6 and newer versions: Use the temporary input object. Perform operations by the macro when the value on the graph changes. Additionally create a graph indicated with 257 points to 320 points. Reallocate consecutive addresses. Copy the I/O comment in the converted csv file to each object. Replace it by a window display. Change the alarm/event item setting. The table will be converted to Bitmem.csv. Import the file by the alarm/event setting. Select the alarm/event display under the Functional Object to Switch screen when Address ON. Activate the macro that can allocate a default value to each address. Set the scaling. Or perform operations by the macro. The image will be converted to a bmp file. Set the file that was converted to shape specification (for version 5 and newer versions). The operation log, Screen display history can be used as a substitute. The screen display history that was displayed during $BS40 (system memory) was ON will be recorded. Control the system memory $SB10 (back light blink control bit) by using the macro for screen load/macro for screen unload. Control the system memory $SB12 (continuous 16

Buzzer Display attribution Window display Flicker only for character Cursor inversion and blink for inputting numerical value and character string Display for host connection Fixed display Tiling Fixed display Image indirect referencing Fixed display Library Pop-up window Two windows simultaneous display Pop-up window Local window replacement Window display position coordinate setting Touch switch window close switch Touch switch window open/close Touch switch copy setting Mark data display for fixed and indirect character strings Touch switch cursor shift buzzer), $SB13 (discontinuous short buzzer), and $SB14 (continuous long buzzer) by the macro for screen load/macro for screen unload. Write the corresponding window screen number in each of the following system memory by the macro for screen load: $SW1 (pop-up screen 1 No.X), $SW4 (pop-up screen 2 No.X), and $SW7 (pop-up screen 3 No.X). No countermeasure available so far. No countermeasure available so far. No countermeasure available so far. Set tiling for fixed objects. The image will be converted to a bmp. The indirect referencing of the bit map display can be used as a substitute. The library will be converted to a vec file by the conversion support tool. However, NS cannot indirectly refer to the vec file. If the number of libraries to be indirectly referred to is 10 or less, the Select Shape of a word lamp can be used. Click the window screen property to select pop-up screen setting. Check off other screen input enable. Use the macro. Click the window screen property (pop -up screen) to select pop-up screen display position. Set the X and Y coordinates by choosing any position. Command button Pop-up screen control Use the macro. Use a word switch as a substitute. The mark data will be converted to a bmp file. Allocate it as a bmp. Choose the touch input method for the value input field. Or set the command button to without 17

Touch switch Display print Numerical value display Indirect specification Touch switch Inversion for input PT status notification Battery status process and activate the value input field by SETFORCUS macro. Create a switch with a system bit allocated. No countermeasure available so far. Set ON/OFF button type: (Type 2-2) Goes ON/OFF according to the ON/OFF of display address 1. For version 6 and newer versions: Control the system memory $SB4 Battery Low (Countermeasure for version 6 and newer). See Appendix 4 Conversion rules of NT31C_631C conversion support tool. 18