Microsoft RemoteFX Error Code 43 Identification and Workaround for the PowerEdge C410x

Similar documents
Test Lab Introduction to the Test Lab Linux Cluster Environment

Riverbed Technology, Inc. 199 Fremont Street San Francisco, CA Phone Fax

D120-S3G User s Guide

Ali Larijani - Microsoft Sanjoy Maity - AMI

FWA-6510 function Setting Introduction

alcasar_documentation Documentation

Cisco Edge 340 User Manual

EX L-8 User Guide

Upgrade Cisco Interface Module for LoRaWAN IXM using the Console

OEM FRU TECHNICAL WHITE PAPER

TrueNAS X-SeriesUnifiedStorageArray Basic Setup Guide. December 2017 Edition

Optional Lab: Install a Wireless NIC in Windows Vista

This Technical Note document contains information on these topics:


Supermicro Utility (IPMICFG) User s Guide

» User Guide « P R E L I M I N A R Y. CP6003-SA/RA/RC IPMI Firmware. If it s embedded, it s Kontron. Doc. ID: , Rev. 2.

M-508 Quick Installation Guide. Screw: Φ 3 mm

This guide is used as an entry point into the Petalinux tool. This demo shows the following:

Matrix 500 Quick Installation Guide

rbox610 Series Robust Din-rail Fanless Embedded System Web Configuration and App Software User s Manual

INSTALLATION. Security of Information and Communication Systems

System Manager Unit (SMU) Hardware Reference

CDE250 IPMI Firmware Upgrade. Reviewers. Modification History

3 Connection, Shell Serial Connection over Console Port SSH Connection Internet Connection... 5

RoadRunner 24AP(i+) Recovering Tool Instructions

ASTi SYNAPSE Cold Start and Installation Manual Document: DOC-01-SYN4-CSI-1

INSTALLATION. Security of Information and Communication Systems. Table of contents

StarBoard FX/FX-DUO Wireless Connection Setup Manual (Windows Vista)

CDE250 IPMI Firmware v3.12 Upgrade. Modification History

Using Alta ENET Products on Microsoft Windows Systems (Rich Wade, 6 SEP 13)

Let us ping! First we will learn the Hello World of a networked machine.

Industrial Cameras: GigE Camera Start Up

BMC User Guide. May 2018


Introduction to Intelligent Platform Management Interface (IPMI)

Configuring GX7 to deliver SNMP traps

SRP-E300/302 THERMAL RECEIPT PRINTER

Create a pfsense router for your private lab network template

USB Type-C Dual Port Gigabit. Ethernet Cable

Understanding UCS Server Configuration Utility User Interface

AST2500 ibmc Configuration Guide

Intel Server Debug and Provisioning Tool (Intel SDP Tool)

USB Type-C Gigabit Ethernet. Adapter

Release Notes for Cisco UCS Server Configuration Utility Release 2.2(2)

SLES Linux Installation Guide

USB 3.0 Dual Port Gigabit. Ethernet Cable

ScopTEL TM IP PBX Software. DNS Server Configuration Wizard

Supermicro Utility (IPMICFG) User s Guide

RNG-406Uv2. USB 3.0 to Gigabit Ethernet Cable

SSD Bay U.2 NVMe RAID Enclosure. User Guide V1.00

Pronto PicOS 1.4 Installation Reference Guide

PAC-5010 Programmable Automation Controller User Guide

RocketRAID 2680/2684 SAS Controller Red Hat Enterprise/CentOS Linux Installation Guide

Lab - Connect to a Router for the First Time

10/02/2015 PetaLinux Linux Image Network Connection

Ubuntu Manually Mount Cdrom Drive Command Line Vmware

Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN

UNIVERGE SV8500 SOFTWARE UPGRADE PROCEDURE FROM S5 TO S6

Congratulations on purchasing Hawking s HWPS12UG 1-Port Parallel + 2 USB Ports Wireless G Print Server. The Hawking HWPS12UG is a powerful and

iris-2400 Web GUI iris-2400 Web GUI IEI iman Web-based Graphics User Interface (GUI) User Manual Page i Rev May 8, 2014

Lab: Install a Wireless NIC in Windows XP

StarBoard FX/FX-DUO Wireless Connection Setup Manual (Windows 7)

RocketRAID 231x/230x SATA Controller Fedora Linux Installation Guide

RocketRAID 231x/230x SATA Controller Red Hat Enterprise/CentOS Linux Installation Guide

10/100Mbps 2Port USB2.0 MFP Server

Plug the USB cable into the WebMaster/WebAlert and your computer. You will see this message on your screen

Idea6410 Ubuntu User Manual V 0.19

Using UCS-Server Configuration Utility

Out of Band procedures for bullx R gen 3 series

Consistent Network Device Naming in Linux

USING THE OOSIML/JAVA COMPILER. With the Command Window

RG-MACC-BASE_v2.01. Installation Guide

GIGABYTE. Software Reference Guide for MP30 (APM) Platform R01. Document Version:

User Manual Network Interface

SR-201 Network Relay Quick Start Guide

These documents and software are covered under the terms and conditions of the fp Technologies, Inc. Program License Agreement

LYNXTechnik AG. Broadcast Television Equipment. APPolo Control User Guide. User Guide

IBM Remote Support Manger for Storage


Dell OpenManage Deployment Toolkit 5.5 for Embedded Linux Release Notes

FlashMaxII Operation Guide

TROUBLESHOOTING : 1. Set up your wireless router via wired connection. 2. Please make sure your adapter is set to obtain IP automatically

M-4132 Quick Start User Guide

Dell OpenManage Deployment Toolkit 5.3 for Embedded Linux Release Notes

USB2.0 LAN DISK User s Manual

Release Notes: SoundPoint/SoundStation IP - BootROM

Lab: Install a NIC in Windows XP

Stylitis-10+ WiFi Setup

CONFIGURING GRANDSTREAM IP PHONES AND GATEWAYS WITH THE 3CX PHONE SYSTEM

OpenSwitch OPX Installation Guide. Release 2.1.0

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Managing Modules. About Modules. Send documentation comments to CHAPTER

Com.X5 Getting Started Guide

AST2500 ibmc Configuration Guide

OpenSwitch OPX Installation Guide with Enhancement Package. Release 2.1.0

RG-MACC_2.0 Installation Manual

System Management Module User's Guide

Console Redirection on VMware ESX Server Software and Dell PowerEdge Servers

Decoder Firmware B1D-220-V AC User s Manual Decoder Firmware B1D-220-V AC User s Manual

Upgrading a FAS2000-series system to an Active/Active Configuration

Transcription:

Microsoft RemoteFX Error Code 43 Identification and Workaround for the PowerEdge C410x Subject: Workaround, if Windows 2008 R2 SP1 Device Management identifies a code 43 device error. Document Version : 1.1 Release On : 2011.8.2 1

Document History item version description date 1 0.1 First release for RemoteFX workaround 2011.4.15 2 1.0 Add description: how to install and use ipmi utility for control each GPGPU power on/off under Linux & Windows 2011.4.28 3 1.1 Wording of some sentences correction 2011.8.2 2

Items Contents Page RemoteFX Setup 3 Device Error Code 43 Workaround Issue Description Steps to duplicate issue. Steps to clear "code 43" error. 4 5 5 IPMIUTIL Installation and Execution Under Windows OS IPMIUTIL Download IPMIUTIL Installation Use IPMIUTIL To Control C410x -Topology -Set Client LAN IP Address -Set C410x BMC IP Address -Verify IPMITOOL C410x Control Power GPGPU Slots On/Off To Clear Device Error 5 6 7 9 10 13 14 15 code 43 IPMITOOL Installation and Execution Under Linux OS IPMIUTIL Download IPMIUTIL Installation Start IPMITOOL Service Use IPMIUTIL To Control C410x -Topology -Set Client LAN IP Address -Set C410x BMC IP Address -Verify IPMITOOL C410x Control Power GPGPU Slots On/Off To Clear Device Error code 43 18 19 20 21 21 22 23 24 25 3

RemoteFX Setup: Refer to the following website links to obtain information on how to setup Windows 2008R2 SP1 RmoteFX service. (1) Install RemoteFX service http://technet.microsoft.com/en-us/library/ff817596(v=ws.10).aspx (2) Hardware Considerations for RemoteFX http://technet.microsoft.com/en-us/library/ff817602(v=ws.10).aspx#bkmk_vhserver Device Error Code 43 Workaround Issue Description If the host system connected to a C410x with a M2070Q is rebooted, it is possible for the M2070Q to have a device error code 43 in Device Manager. (See example below) 4

Steps to duplicate issue 1. Turn on C410x. 2. Turn on the host. 3. Check Device Manager. All the devices should be normal. 4. Reboot the host, C410x still keep power on status. 5. Check M2070Q in Device Manager. A Yellow Bang indicates a device error code 43. Steps to clear "code 43" error NOTE: An ipmi-utility loaded on a remote client is required to clear the "code43" error. IPMIUTIL Installation and Execution Under Windows OS IPMIUTIL Download IPMIUTIL Installation Use IPMIUTIL To Control C410x -Topology -Set Client LAN IP Address -Set C410x BMC IP Address Verify IPMIUTIL C410x Control Power GPGPU Slots On/Off To Clear Device Error code 43 5

1. Go to IPMIUTIL website. http://ipmiutil.sourceforge.net/ IPMIUTIL Download 2. Click Download ipmiutil-2.7.5-win32.zip (889 KB) to download. 3. Copy the installation package to USB flash. 6

IPMIUTIL Installation 1. Boot into Windows 2008 R2 SP1 x86_64. 2. Insert USB FLASH and open file manager. 3. Double click on ipmiutil-2.7.5-win32.zip and press Extract all files. 7

4. Provide the path name where you want to extract the files and click the Extract button. 8

Use IPMITOOL to Control C410x TOPOLOGY Titanium BMC LAN port connect to switch BMC LAN port IP:192.168.0.120 Server LAN port 0 connect to switch LAN port 0 IP:192.168.0.1 9

1. Log in W2K8R2SP1. 2. Start Control Panel Set Client LAN IP Address 3. Choose View network status and tasks under Network and Internet. 10

4. Click Change adapter settings. 5. Right-click LAN Area Connection Properties. 11

6. Double-click Internet Protocol Version 4 (TCP/IPv4). 7. Fill IP address 192.168.0.1 and Subnet mask 255.255.255.0 and then press OK. 12

Set C410x BMC IP Address (Front Panel Button) 1. Change BMC IP address using front panel buttons. Front System LEDs 2. Hold down the ID button for 5 seconds. 3. While pressing the ID button, press and hold the power button for 5 seconds. 4. Release the power button, and then the ID button. 5. It will take ~30 seconds to change the configuration. 6. The ID light indicates which mode has been selected: - Solid for 5 seconds indicates static IP - Flashing for 5 seconds indicates DHCP 7. The static mode default IP address is 192.168.0.120. 13

Verify IPMIUTIL C410x Control On HOST server end: 1. Log in W2K8R2SP1. 2. Press +R to call Run and type cmd and then press OK. 3. Switch folder to ipmiutil which you extracted before. 4. Type "ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 18 01" Verify whether BMC feedback is "respdata [len=15]: 20 01 01 21 02 ff a2 02 00 00 00 00 00 00 00". See example below. 14

Power GPGPU Slots On/Off To Clear Device Error "code 43" The following table lists the IPMIUTIL raw command to switch on/off each GPGPU. Port Map Configure Command NetFn CMD Slot power control OEM command c0h F0h Slot power control OEM command Byte Data Field Request Data 1 Bit7 : Slot 8 Bit6 : Slot 7 Bit5 : Slot 6 Bit4 : Slot 5 Bit3 : Slot 4 Bit2 : Slot 3 Bit1 : Slot 2 Bit0 : Slot 1 2 Bit7 : Slot 16 Bit6 : Slot 15 Bit5 : Slot 14 Bit4 : Slot 13 Bit3 : Slot 12 Bit2 : Slot 11 Bit1 : Slot 10 Bit0 : Slot 9 Response Data 1 Completion code Example1. If GPGPU slot1 get code 43 error GPGPU SLOT 01 to switch on/off 1. Power off GPGPU cards by ipmiutil command. # Type ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0 01 00 2. Power on GPGPU cards by ipmiutil command,type the same command again will switch current status. # Type ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0 01 00 3. Reboot the HOST by ipmitool command or other method of Remote control. #./ipmitool -I lanplus -H HOST IP address -U root -P root chassis power reset. 4. The code 43 error will be disappeared after HOST reboot. Example2. If GPGPU slot9 get code 43 error GPGPU SLOT 09 to switch on/off 15

1. Power off GPGPU cards by ipmiutil command. # Type ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0 00 01 2. Power on GPGPU cards by ipmiutil command, type the same command again will switch current status. # Type ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0 00 01 3. Reboot the HOST by ipmitool command. #./ipmitool -I lanplus -H HOST IP address -U root -P root chassis power reset. 4. The code 43 error will disappear after HOST reboot. Example3. If GPGPU slot16 get code 43 error GPGPU SLOT 16 to switch on/off 1. Power off GPGPU cards by ipmiutil command. # Type ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0 00 80 2. Power on GPGPU cards by ipmiutil command, type the same command again to switch current status. # Type ipmiutil cmd -N 192.168.0.120 -U root -P root 00 20 c0 F0 00 80 3. Reboot the HOST by ipmitool command or other method of Remote control. #./ipmitool -I lanplus -H HOST IP address -U root -P root chassis power reset. 4. The code 43 error disappears after HOST reboot 16

IPMITOOL Installation and Execution Under Linux OS IPMIUTIL Download IPMIUTIL Installation Start IPMITOOL Service Use IPMIUTIL To Control C410x -Topology -Set Client LAN IP Address -Set C410x BMC IP Address -Verify IPMIUTIL C410x Control Power GPGPU Slots On/Off To Clear Device Error code 43 17

IPMITOOL Download 1. Go to IPMITOOL website. http://sourceforge.net/projects/ipmitool/files/ 2. Click Download ipmitool-1.8.11.tar.gz (770.0 KB) to download. Download will start automatically, if not you need to press direct link to download it. 3. Copy the installation file to USB flash. 18

IPMITOOL Installation 4. Boot into RHEL 5u3 later version. 5. Mount USB flash (ex device sdb1) for using. #mount /dev/sdb1 /mnt 6. Copy ipmitool installation package to the system from mounted folder. #cp /mnt/ipmitool-1.8.11.tar.gz / 7. Uncompress the ipmitool package #tar zxvf /ipmitool-1.8.11.tar.gz 8. Swich folder to ipmitool installation where we extracted. #cd /ipmitool-1.8.11 9. Configure config file at first, if complete you can see interface information. #./configure 10. Compile ipmitool file. #make && make install 19

Start IPMITOOL Service 1. Start the ipmitool service. #service ipmi start 2. Check ipmitool installation correct, IPMITOOL will show you installation version #ipmitool V 20

Use IPMITOOL To Control C410x TOPOLOGY Titanium BMC LAN port connect to switch BMC LAN port IP:192.168.0.120 Server LAN port 0 connect to switch LAN port 0 IP:192.168.0.1 21

Set Client LAN IP Address 1. Log in RHEL5. 2. Check your LAN hardware device, eth0 and eth1 would show in list. #ifconfig a 3. Set LAN IP address. #ifconfig eth0 192.168.0.1 netmask 255.255.255.0 up 4. Check if IP is set on eth0, IP and mask will be set and enabled. #ifconfig 22

Set C410x BMC IP Address (Front Panel Button) 1. Change BMC IP address using front panel buttons. Front System LEDs 2. Hold down the ID button for 5 seconds. 3. While pressing the ID button, press and hold the power button for 5 seconds. 4. Release the power button, and then the ID button. 5. It will take ~30 seconds to change the configuration. 6. The ID light indicates which mode has been selected: - Solid for 5 seconds indicates static IP - Flashing for 5 seconds indicates DHCP 7. The static mode default IP address is 192.168.0.120. 23

Verify IPMITOOL C410x Control On HOST server end: 1. Log in RHEL. 2. Execute ipmitool to check if C410x information is displayed. # ipmitool I -lanplus -U root -P root -H 192.168.0.120 fru 24

Power GPGPU Slots On/Off To Clear Device Error code 43 The following table lists the IPMIUTIL raw command to switch on/off each GPGPU. Example1. If GPGPU slot1 gets code 43 error GPGPU SLOT 01 to switch on/off 1. Power off GPGPU cards by ipmiutil command. # Type ipmitool -I lanplus -H 192.168.0.120 -U root -P root raw 0x30 0xf0 01 00 2. Power on GPGPU cards by ipmiutil command, typing the same command again will switch current status. # Type ipmitool -I lanplus -H 192.168.0.120 -U root -P root raw 0x30 0xf0 01 00 3. Reboot the HOST by ipmitool command or other method of Remote control. #./ipmitool -I lanplus -H HOST IP address -U root -P root chassis power reset. 4. The code 43 error disappears after HOST reboot. 25

Example2. If GPGPU slot9 gets code 43 error GPGPU SLOT 09 to switch on/off 1. Power off GPGPU cards by ipmiutil command. # Type ipmitool -I lanplus -H 192.168.0.120 -U root -P root raw 0x30 0xf0 00 01 2. Power on GPGPU cards by ipmiutil command, typing the same command again switchs current status. # Type ipmitool -I lanplus -H 192.168.0.120 -U root -P root raw 0x30 0xf0 00 01 3. Reboot the HOST by ipmitool command. #./ipmitool -I lanplus -H HOST IP address -U root -P root chassis power reset. 4. The code 43 error disappears after HOST reboot. Example3. If GPGPU slot16 gets code 43 error GPGPU SLOT 16 to switch on/off 1. Power off GPGPU cards by ipmiutil command. # Type ipmitool -I lanplus -H 192.168.0.120 -U root -P root raw 0x30 0xf0 00 80 2. Power on GPGPU cards by ipmiutil command, typing the same command again switchs current status. # Type ipmitool -I lanplus -H 192.168.0.120 -U root -P root raw 0x30 0xf0 00 80 3. Reboot the HOST by ipmitool command or other method of Remote control. #./ipmitool -I lanplus -H HOST IP address -U root -P root chassis power reset. 4. The code 43 error will be disappeared after HOST reboot. 26