EKI-7526I 16 Port Unmanaged Industrial Ethernet Switch. User Manual

Similar documents
EKI-2528PAI 8-port Industrial Unmanaged Ethernet Switch with 4-port PoE. User Manual

EKI-7529MI, EKI-7529MI/ST FX Port Unmanaged Industrial Ethernet Switch. User Manual

User Manual EKI-2728I. 8-port Industrial Unmanaged Gigabit Ethernet Switch

User Manual EKI-6528TI/ 6528TPI. EN port M12 Unmanaged/ PoE Switch with Wide Temperature

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

SE200 Series Switches. User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

User Manual ADAM-6100EI Series. EtherNet/IP I/O Modules

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

User Manual IDS-3206 Series. 6.5" Industrial Panel Mount Monitor

User Manual MIOe port CAN-bus PCIE/MIOe Module with Isolation Protection

User Manual VEGA K HEVC/H.265 Real-time PCIe Encoder Card

User Manual IDS-3106 Series. 6.5" Industrial Open Frame Monitor

User Manual ECU-P1524PE HSR/PRP Module

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

User Manual IDS-3119 Series. 19" Industrial Open Frame Monitor

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

User Manual PCL channel Isolated Digital Output Card

User Manual PCM Port CAN-Bus Mini PCIe Module with Isolation Protection

MIC-3002A Series. 3U 6-slot CompactPCI Enclosures with Rear I/O and 6" LCD. User Manual

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

Manual Elinx EIR408-T. 8 Port-10/100/1000 Unmanaged Din Rail Ethernet Switch

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

User Manual TPC-8100TR. 10.4" EN50155 Railway Panel Computer

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

PCM PC/ bit Digital I/O Module. User Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

User Manual PPC-IPS. Intelligent Power System for PCs

User Manual IDS-3217 Series. 17" Industrial Panel Mount Monitor

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

LNX-1002C-SFP Series

LNX-0702G-SFP Series

AMAX-2750SY Series. 32-ch AMONet RS-485 Isolated Digital I/O Slave Modules. User Manual

User Manual PCIE ch Digital I/O PCI Express Card

User Manual EKI-1221IEIMB EKI-1221IPNMB. Modbus TCP to PROFINET EtherNet/IP Protocol Gateway

User Manual DSD-5028 Series. 28" Industrial Stretched Signage Display Monitor

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

MDI/MDIX) FEP-32005T-2

User Manual ARK-6610/6620. Compact Mini-ITX Chassis

ADAM-6520 Series. 5-port 10/100 Mbps Industrial Ethernet Switches. Features. Introduction. Specifications. Ordering Information.

User Manual IDS-3118W Series. 18.5" Industrial Open Frame Monitor

User Manual. IDS-3215 Series. 15" Industrial Panel Mount Monitor

User Manual. FPM-7181W Series. 18.5" Industrial Monitor with Projected Capacitive Touchscreen, Direct-VGA and DVI Ports

User Manual PCL ch Isolated Digital I/O ISA Cards

LNP-0501 Series. User Manual. 5-Port Industrial PoE+ Unmanaged Ethernet Switches with 4*10/100Tx (30W/Port) + 1*10/100Tx

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

Industrial 3-Port Fast Ethernet Media Converter Switches

FPM-5151G/5171G/ 5191G Series

PCLD-8751 PCLD User Manual

USB Channel Isolated Digital I/O USB Module. User Manual

Industrial Slim Type Fast Ethernet Rail Switch

gigabit industrial ethernet user manual Models , ,

KFC-200. Installation Guide

UNO-1140/F. Advantech EVA x86 SoC Fanless Box PC with 1 x LAN, 8 x Isolated COM. User Manual

User Manual ITM-5117 Series. 17" Industrial LED Touch Monitor

User Manual PCM-27D24DI. 24-ch Isolated Digital I/O and 2-ch Counter PCI Express Mini Card

User Manual IPC U Industrial Rackmount Chassis for SHB and SBC

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

16/24-Port Gigabit Desktop Switch

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

User Manual APAX-5522PE. IEC Certified PAC with Marvel XScale CPU

IES308-2F. Introduction: Packing List: Features: 8-port Unmanaged Industrial Ethernet Switch Hardware Installation Guide

GSW-1657 GSW User's Guide. 16/24-port Gigabit Ethernet Switch. Ver

24-Port Gigabit Ethernet Switches

M727xSP. PoE Powered. Ethernet Media Converter 10/100BASE-TX TO 100BASE-SX/LX. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

IPC-611 Series 4U Rackmount Industrial Chassis User Manual

User Guide TL-SG1005D TL-SG1008D. 5/8-Port Gigabit Desktop Switch. alarm shop. Rev:

FWA-6280A User Manual 1. FWA-6280A User Manual

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

User Manual PPC Intel ATOM N2600 processor based microcomputer, with 15" color TFT LCD display

MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC:

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

User Manual PCIE-1730H. 32-ch Isolated Digital I/O with Digital filter PCI Express Card

ITA-1711 Series Fanless Compact Embedded IPC with Intel Celeron Dual Core CPU Startup Manual

Ether-FSH2400C 24-port 10/100Base-TX Switch

User Manual EBPC Embedded Industrial Computer Chassis for 3.5 Biscuit SBCs

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

Industrial Unmanaged Ethernet Switch

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

Transcription:

EKI-7526I 16 Port Unmanaged Industrial Ethernet Switch User Manual

Copyright The documentation and the software included with this product are copyrighted 2009 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. However, Advantech Co., Ltd. assumes no responsibility for its use, nor for any infringements of the rights of third parties, which may result from its use. Acknowledgements Intel and Pentium are trademarks of Intel Corporation. Microsoft Windows and MS-DOS are registered trademarks of Microsoft Corp. All other product names or trademarks are properties of their respective owners. Part No. Printed in China EKI-7526I_Manual_ed4 4th Edition October 2009 ii

Product Warranty (2 years) Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship for two years from the date of purchase. This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech, or which have been subject to misuse, abuse, accident or improper installation. Advantech assumes no liability under the terms of this warranty as a consequence of such events. Because of Advantech s high quality-control standards and rigorous testing, most of our customers never need to use our repair service. If an Advantech product is defective, it will be repaired or replaced at no charge during the warranty period. For out-of-warranty repairs, you will be billed according to the cost of replacement materials, service time and freight. Please consult your dealer for more details. If you think you have a defective product, follow these steps: 1. Collect all the information about the problem encountered. (For example, CPU speed, Advantech products used, other hardware and software used, etc.) Note anything abnormal and list any onscreen messages you get when the problem occurs. 2. Call your dealer and describe the problem. Please have your manual, product, and any helpful information readily available. 3. If your product is diagnosed as defective, obtain an RMA (return merchandize authorization) number from your dealer. This allows us to process your return more quickly. 4. Carefully pack the defective product, a fully-completed Repair and Replacement Order Card and a photocopy proof of purchase date (such as your sales receipt) in a shippable container. A product returned without proof of the purchase date is not eligible for warranty service. 5. Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer. iii

Declaration of Conformity CE This product has passed the CE test for environmental specifications. Test conditions for passing included the equipment being operated within an industrial enclosure. In order to protect the product from being damaged by ESD (Electrostatic Discharge) and EMI leakage, we strongly recommend the use of CE-compliant industrial enclosure products. FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Technical Support and Assistance Step 1. Step 2. Visit the Advantech web site at www.advantech.com/support where you can find the latest information about the product. Contact your distributor, sales representative, or Advantech s customer service center for technical support if you need additional assistance. Please have the following information ready before you call: - Product name and serial number - Description of your peripheral attachments - Description of your software (operating system, version, application software, etc.) - A complete description of the problem - The exact wording of any error messages EKI-7526I_Manual_ed4 iv

Safety Instructions 1. Read these safety instructions carefully. 2. Keep this User's Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6. Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage. 7. The openings on the enclosure are for air convection. Protect the equipment from overheating. DO NOT COVER THE OPENINGS. 8. Make sure the voltage of the power source is correct before connecting the equipment to the power outlet. 9. Position the power cord so that people cannot step on it. Do not place anything over the power cord. 10. All cautions and warnings on the equipment should be noted. 11. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage. 12. Never pour any liquid into an opening. This may cause fire or electrical shock. 13. Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel. 14. If one of the following situations arises, get the equipment checked by service personnel: a. The power cord or plug is damaged. b. Liquid has penetrated into the equipment. c. The equipment has been exposed to moisture. d. The equipment does not work well, or you cannot get it to work according to the user's manual. e. The equipment has been dropped and damaged. f. The equipment has obvious signs of breakage. 15. DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW -40 (-40 ) OR ABOVE 85 (185 ). THIS COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT. v

Safety Precaution - Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage. 1. To avoid electrical shock, always disconnect the power from your PC chassis before you work on it. Don't touch any components on the CPU card or other cards while the PC is on. 2. Disconnect power before making any configuration changes. The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components. EKI-7526I_Manual_ed4 vi

Chapter 1 Contents Overview...2 1.1 Introduction... 2 1.1.1 High-Speed Transmissions... 2 1.1.2 Dual Power Input... 2 1.1.3 Flexible Mounting... 2 1.1.4 Advanced Protection... 2 1.1.5 Wide Operating Temperature... 2 1.1.6 Easy Troubleshooting... 2 1.2 Features... 3 1.3 Specification... 4 1.4 Packing List... 6 1.5 Safety Precaution... 6 Chapter 2 Installation...8 2.1 LED Indicators... 8 Table 2.1: EKI-7526I LED Definition...8 2.2 Dimensions (units: mm)... 9 Figure 2.1: Front View of EKI-7526I...9 Figure 2.2: Side View of EKI-7526I...10 Figure 2.3: Rear View of EKI-7526I...11 Figure 2.4: Top View of EKI-7526I...11 2.3 Mounting... 12 2.3.1 Wall mounting... 12 Figure 2.5: Combine the Metal Mounting Kit...12 2.3.2 DIN-rail Mounting... 13 Figure 2.6: Installation to DIN-rail Step 1...13 Figure 2.7: Installation to DIN-rail Step 2...14 2.4 Network Connection... 15 2.5 Power Connection... 15 Figure 2.8: Pin Assignment of the Power Connector..15 Chapter 3 Troubleshooting...17 Appendix A Pin Assignment & Wiring...19 Figure A.1: RJ-45 Pin Assignment...19 Figure A.2: EIA/TIA-568B...19 Figure A.2: EIA/TIA-568A...19 vii Contents

EKI-7526I_Manual_ed4 viii

CHAPTER Overview Sections include: Introduction Features Specifications Packing List Safety Precaution 1 Chapter1

Chapter 1 1.1 Introduction Overview Aside from 16 x 10/100Base-TX fast Ethernet port, the long MTBF (Mean Time Between Failures) ensures that the EKI-7526I is a cost-effective solution and meets the high reliability requirements demanded by industrial applications. 1.1.1 High-Speed Transmissions The EKI-7526I includes a switch controller that can automatically sense transmission speeds (10/100 Mbps). The RJ-45 interface can also be auto-detected, so MDI or MDI- X is automatically selected and a crossover cable is not required. All Ethernet ports have memory buffers that support the store-and-forward mechanism. This assures that data is properly transmitted. 1.1.2 Dual Power Input EKI-7526I redundant power input design is with power reserve protection to prevent the switch device broken by wrong power wiring. When one of power input is fail, P- Fail LED will turn on and send an alarm through a relay output for notifying user. 1.1.3 Flexible Mounting EKI-7526I is extremely compact (79 x 152 x 105 mm) and can be mounted on a DINrail or a panel, so it is suitable for any space-constrained environment. 1.1.4 Advanced Protection EKI-7526I supports up to 3,000 V DC EFT protection for power line, and also supports 4,000V DC ESD protection for Ethernet ports. With these 2 strong protections, it can secure equipment against unregulated voltage and make systems safer and more reliable. Further, EKI-7526I provides currency overload protection with a resettable fuse to ensure that the device component won t be damaged by overload current. 1.1.5 Wide Operating Temperature The operating temperature of the EKI-7526I is between -40 ~ 75. With such a wide range, you can use the EKI-7526I in some of the harshest industrial environments that exist. 1.1.6 Easy Troubleshooting LED indicators make troubleshooting quick and easy. Each 10/100 Base-TX port has 2 LEDs that display the link status, transmission speed and collision status. Also the three power indicators P1, P2 and P-Fail help you diagnose immediately. EKI-7526I_Manual_ed4 2

1.2 Features Provides 16 x 10/100 Mbps Ethernet ports with RJ45 connector Supports full/half duplex flow control Supports store and forward transmission Supports auto-negotiation Supports MDI/MDI-X auto crossover Provides broadcast storm protection Supports surge protection (EFT) 3,000 V DC for power line Supports 4,000 V DC ESD protection for Ethernet Supports +12 ~ 48 V DC power input Provides flexible mounting: DIN-rail, Wall Mounting Supports Wide range operating temperature from -40 ~ 75 (EKI-7526I) 3 Chapter1

1.3 Specification Communications Compatibility IEEE 802.3, 802.3u, 802.3x LAN 10/100Base-TX, 100Base-FX Transmission Distance Ethernet : Up to 100 m (Cat.5e, Cat.6 RJ-45 cable suggested for Gigabit port) Transmission Speed Ethernet : Up to 100 Mbps Interface Connectors LED Indicators 16 x RJ-45 6-pin removable screw terminal (power & relay) Unit: PWR1, PWR2, P-Fail TX port: Link/Active, Duplex/Collision Power Power Consumption Power Input Fault Output Inrush Current Max. 5.28 Watts 2 x Unregulated +12 ~ 48 V DC 1 Relay Output 200% @ 24V DC Mechanism Dimensions (WxHxD) Enclosure Mounting 79 x 152 x 105 mm IP30, Metal shell with solid mounting kits DIN-rail, Wall Protection ESD (Ethernet) Surge (EFT for power) 4,000 V DC 3,000 V DC Environment Operating Temperature -40 ~ 75 Operating Humidity 5% ~ 95% (non-condensing) Storage Temperature -40 ~ 85 MTBF 261542 hours EKI-7526I_Manual_ed4 4

Certifications Safety UL 508*, Class 1 Division 2* EMC U.S.A.: FCC Part 15 CISPR 22 EU: EN55011 EN55022 EN61000-3-2/3 EN55024 IEC61000-4-2/3/4/5/6/8 EN61000-6-2/4 Free Fall IEC60068-2-32 Shock IEC60068-2-27 Vibration IEC60068-2-6 * Future Release 5 Chapter1

1.4 Packing List 1 x EKI-7526I 16 Port Unmanaged Industrial Ethernet Switch 1 x eautomation Industrial Communication CD-ROM with User manual 2 x Wall Mounting Bracket and Screws 1 x DIN-rail Mounting Bracket and Screws 1 x EKI-7526I Startup Manual 1 x DC Jack Cable 2.0/150mm 1.5 Safety Precaution Attention IF DC voltage is supplied by an external circuit, please use a protection device on the power supply input. EKI-7526I_Manual_ed4 6

CHAPTER Installation Sections include: LED Indicators Dimensions Mounting Network Connection Fiber Optic Network Connection Power Connection 7

Chapter 2 Installation In this chapter, you will be given an overview of the EKI-7526I hardware installation procedures. 2.1 LED Indicators There are few LEDs display the power status and network status located on the front panel of EKI-7526I, each of them has its own specific meaning as the table below. Table 2.1: EKI-7526I LED Definition LED Color Description PWR1 Green On Off Power input 1 is active Power input 1 is inactive PWR2 Green On Off Power input 2 is active Power input 2 is inactive P-Fail Red On Off Power input 1 or 2 is inactive Power input 1 and 2 are both active, or no power input On Connected to network Link/Active (1~16) Green Flashing Networking is active Off Not connected to network On Ethernet port full duplex Duplex/Collision (1~16) Yellow Flashing Collision of packets occurs Off Ethernet port half duplex or not connect to network EKI-7526I_Manual_ed4 8

2.2 Dimensions (units: mm) Figure 2.1: Front View of EKI-7526I 9

Figure 2.2: Side View of EKI-7526I EKI-7526I_Manual_ed4 10

Figure 2.3: Rear View of EKI-7526I Please refer to page 19 for pin assignment. Figure 2.4: Top View of EKI-7526I 11

2.3 Mounting The EKI-7526I supports two mounting methods: DIN-rail & Wall. 2.3.1 Wall mounting EKI-7526I can be wall-mounted by using the included mounting kit. Then, hang on the EKI-7526I to the nails on the wall. First, use the screws included in the package to combine the EKI-7526I and metal mounting kit. And then you can install the device firmly via the components, please see Figure 2.5 as below. Figure 2.5: Combine the Metal Mounting Kit EKI-7526I_Manual_ed4 12

2.3.2 DIN-rail Mounting You can also mount EKI-7526I on a standard DIN-rail by below steps. The DIN-rail kit is screwed on the industrial switch when out of factory. If the DIN-rail kit is not screwed on the industrial switch, please screw the DIN-rail kit on the switch first. First, hang the EKI-7526I to the DIN-rail with angle of inclination. See figure 2.6. Figure 2.6: Installation to DIN-rail Step 1 13

Then, let the device down straight to slide over the rail smoothly. See Figure 2.7 Figure 2.7: Installation to DIN-rail Step 2 EKI-7526I_Manual_ed4 14

2.4 Network Connection The EKI-7526I has 16 x RJ-45 ports that support connection to 10 Mbps Ethernet, or 100 Mbps Fast Ethernet, and half or full duplex operation. EKI-7526I can be connected to other hubs or switches via a twisted-pair straight-through or crossover cable up to 100m long. The connection can be made from any TX port of EKI-7526I (MDI-X) to another hub or switch either MDI-X or uplink MDI port. EKI-7526I supports auto-crossover to make networking more easy and flexible. You can connect any RJ-45 (MDI-X) port on the switch to any device such as a switch, bridge or router. 2.5 Power Connection The EKI-7526I supports dual +12 ~48 V DC power inputs and power-fail relay output. Figure 2.8: Pin Assignment of the Power Connector You can connect an alarm indicator, buzzer or other signaling equipment through the relay output. The relay opens if power input 1 or 2 fails ( Open means if you connect relay output with an LED, the light would be off). 15

CHAPTER Troubleshooting EKI-7526I_Manual_ed4 16

Chapter 3 Troubleshooting 1. Power Input Verify that is using the right power cord/adapter 48 V DC, please don t use the power adaptor with DC output voltage higher than 48V, or it will burn this converter down. 2. Cable Select the proper UTP cable to construct user network. Please check that is using the right cable. Use Unshielded Twisted-Pair (UTP) or Shielded Twisted-Pair (STP) cable for RJ-45 connections: 100 Category 3, 4 or 5 cable for 10 Mbps connections or 100 Category 5 cable for 100 Mbps connections. Also, be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet). 3. Diagnosing LED Indicators The switch can be easily monitored through panel indicators, which describes common problems user may encounter and where user can find possible solutions, to assist in identifying. If the power indicator does not light up when the power cord is plugged in, user may have a problem with power cord. Then check for loose power connections, power losses or surges at power outlet. If user still cannot resolve the problem, contact the local dealer for assistance. If the Industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit, please check your system s Ethernet devices configuration or status. 17

APPENDIX Pin Assignment & Wiring EKI-7526I_Manual_ed4 18

Appendix A Pin Assignment & Wiring It is suggested to adopt ELA/TIA as the wiring of the RJ-45. Figure A.1: RJ-45 Pin Assignment Figure A.2: EIA/TIA-568B Figure A.2: EIA/TIA-568A 19