Installation Note. Agilent Technologies Firmware Upgrade Kit E for ESA-L1500A Spectrum Analyzer

Similar documents
Installation Note. Agilent Technologies ESA-E Series Spectrum Analyzers High Stability Frequency Reference (Option 1D5) Retrofit Kit

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers

QUICK GUIDE FOR. Installing Nokia Connectivity Cable Drivers

Installation Note. Agilent ESG and ESG-D Series Signal Generators Add Option 1E5 Upgrade Kit Kit Part Number E

factory field upgrade

User Manual. August 2008 Revision 1.0. SKH300 ibutton Reader Configuration Utility

Keysight E7515A UXM Firmware Update Tool

Keysight E6640A EXM Wireless Test Set

Installation Note. Agilent PSA Series Spectrum Analyzers Secure Memory Erase, Option 117

Agilent OpenLAB Chromatography Data System (CDS)

Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

Installation Note E Copyright 2006, Agilent Technologies Inc. Printed in the UK Revision Date: April 26, 2006

Keysight E6650AU-TRX Module Add

HP LaserJet MFP Analog Fax Accessory 300. Supplemental Information

MusicTel-Net/Net+ Installation and Operation Manual

Agilent Dissolution Tester Driver

Installation Guide. English. HP LaserJet 5, 5M and 5N Printer Duplex Printing Accessory (C3920A)

RemoteWare OS/2 Client

Installation Note ESG Vector Signal Generator E4438C Add Option 005 (Internal Hard Drive) Kit Part Number E

Agilent Flowmeter ADM2000

Agilent 86121A WDM Channel Analyzer

HP OmniBook DiagTools. User s Guide

IDEA. User s Guide. Part No IDE02 Issue 1-0, April 1995 Printed in U.S.A. (183)

EZ 135 Parallel Port Drive

Installation Note. Configurable Test Set Upgrade Kit. For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number

Agilent E2094M IO Libraries

HP StorageWorks Performance Advisor. Installation Guide. Version 1.7A

DPT - EN1 R1 Users Manual

hp l1619a smart attachment module

User's Guide. diskette drive. Rev. 6/1/97 Copyright 1997 Micro Solutions, Inc.

Setting up a LAN Instrument Network. Installation Guide

Analog & Digital Output Module Quick Start Guide

LaserJet Pro M501 Getting Started Guide

SymSYNC TM User s Guide

Keysight N5191A/93A UXG X-Series Agile Signal Generator

Agilent 89600B VSA. Software Installation Guide

Keysight Technologies N9020B MXA Signal Analyzer

System Manager Unit (SMU) Hardware Reference

Bluetooth wireless printing. hp deskjet 450 mobile printer

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Agilent OpenLAB Chromatography Data System

Agilent OpenLAB Chromatography Data System

Color LaserJet Pro M452dw Getting Started Guide

LI Automated Soil CO 2 Flux System. Configuring the Palm Tungsten C for use with the LI-8100

Installation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit

ESA Spectrum Analyzer Firmware Upgrade Procedure ** PC s with Windows 7 & 8 **

Modem Command Guidelines HP Notebook Series

x10data Smart Client 6.5 for Windows Mobile Installation Guide

For Powerful Digital Marketing and Total Multimedia Solution DV-66. User s Guide

Agilent G1701DA MSD Productivity ChemStation Software

Tutorial. Includes lessons on transferring music to ipod, playing music, and storing files on ipod

Hardware/Software Specifications for Ebix-Hosted Systems

VERITAS StorageCentral 5.2

Keysight Software. Installation Guide

ENCAD File Print Utility for Windows 95

HP Internet Usage Manager Software Release Notes

Rocket 133/133S/133SB User s Manual. Revision: 1.1 Date: Dec HighPoint Technologies, Inc.

USB Synchronizer Plug-in

Upgrading Firmware for the CETAC ASXPRESS PLUS Rapid Sample Introduction System

Agilent G1732AA MSD Security ChemStation

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures.

Firmware Loader. Software. For support mail to: tech mca.nl See also our website: mca.com. Software Manual. Revision 1.

OPERATING MANUAL. WINDOWS Temperature Controller. Digi -Sense

FX Tools Software Package - FX CommPro N2 User s Guide

Upgrading and Servicing Guide

Software User s Guide

Bluetooth 4.0 USB Adapter

Keysight Software

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

HP Classroom Manager. Software Installation and Setup Quick Start Guide. HP Part Number: NW281AA

PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL

Daniel MeterLink Software v1.40

LaserJet Pro MFP M426, M427 Getting Started Guide

A9890A RAID Smart Array 6402 Controller Quick Installation Guide

Software Upgrade Online Help

Issue 1 EN. Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

Agilent OpenLAB Chromatography Data System (CDS)

Microscan Barcode Reader

TrendSense. Instructions for Use. TrendSense and TrendSense Communicator

Nokia E61i support

Firmware/Bootloader Update Manual

Keysight M9393A PXIe Vector Signal Analyzer

TippingPoint Intrusion Prevention System Release Notes

Symantec ediscovery Platform

PC Connecting Kit. Operating Instructions

Veritas NetBackup for SQLite Administrator's Guide

86100 Series Infiniium DCA Oscilloscope

M-crew for HAR-D1000

NVM-Professional NVM-Server NVM-Server Desktop NVM-Server XL. Windows 2000 Platform Description and Installation Instructions

Upgrade Guide GateManager Version 5.x to 5.x

Teradici PCoIP Software Client for Windows

unisys Agile Business Suite How to Install Visual Studio 2013 for AB Suite 5.0 Applies to: Developer 5.0

x10data Smart Client 7.0 for Windows Mobile Installation Guide

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

Symantec Desktop and Laptop Option 8.0 SP2. Symantec Desktop Agent for Mac. Getting Started Guide

Reinstalling the Operating System on the Dell PowerVault 745N

User Guide for Accessing Cisco Unity Connection Voice Messages in an Application

Portable Data Collector Series Z-9000 ( Version 1.0) User s Manual ZEBEX INDUSTRIES INC.

Nokia 9300 and Nokia 9500 Communicator with BlackBerry Connect

Transcription:

Installation Note Agilent Technologies Firmware Upgrade Kit E4411-60005 for ESA-L1500A Spectrum Analyzer Part Number E4411-90026 Printed in USA June 2000

Notice. The information contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard to this material, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Copyright 1997-2000 Agilent Technologies, Inc. All Rights Reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. 1400 Fountaingrove Parkway, Santa Rosa, CA 95403-1799, USA

Firmware Upgrade Kit E4411-60005 for ESA-L1500A Spectrum Analyzer Product Affected:......................... Serial Numbers:.......................... Options:................................. To Be Performed By:...................... Estimated Installation Time:................ Estimated Verification Time:............... ESA-L1500A Spectrum Analyzer All All (X) Agilent Technologies Service Center (X) Personnel Qualified by Agilent (X) Customer 30 minutes 1 minute Introduction The firmware revision is changed by downloading the updated firmware files via a computer RS-232 interface. This installation note includes separate procedures for PC, Laptop, or Palmtop computers. Installation Kit Parts List Table 1 Firmware Upgrade Kit E4411-60005 Contents Item Quantity Description Part Number 1 1 Firmware upgrade (DOS disk) E4411-10002 2 1 HP Palmtop serial cable F1015A 3 1 Installation note E4411-90026 Equipment Required The computer controller may be a PC (IBM compatible), Laptop (HP OmniBook), or Palmtop (HP 200LX). Please note that the Palmtop must have 256KB available memory for DOS and a 5MB or larger flash disk. Installation Note E4411-90026 3

Installation Procedure: PC Version This procedure uses a PC (IBM-compatible computer) to download new firmware into an ESA- Series spectrum analyzer. 1. Connect the computer to the spectrum analyzer. a. Connect the dsub end of the HP Palmtop serial cable to the computer RS-232 port. b. Connect the other end of the HP Palmtop serial cable to the service connector on the rear panel of the spectrum analyzer. The logo should face the left side of the spectrum analyzer, as viewed from the front of the analyzer. Typically, you would use the COM2 RS-232 port, but COM1 is acceptable if it is available. No other program can make use of this port at any time during the procedure. 2. Insert the firmware upgrade disk into the floppy drive of the computer. a. Create an empty directory called esa_dnld on the C:\ drive to unpack the self-extracting archive. b. Using MS Windows, go to File Manager and select drive (A:\ or B:\). The file desa1500.exe should be present. c. Copy desa1500.exe, to the esa_dnld directory on the C:\ drive: A:\copy desa1500.exe C:\esa_dnld d. Change to the C:\esa_dnld directory e. In MS-DOS, type desa1500.exe and press Enter. In File Manager, double-click on desa1500.exe. 3. Verify that the following items were unpacked: readme.txt desa1500.bat split_dl.exe wait.exe esa1500.out desa1500.pif desa1500.ico these instructions script to perform the download the actual firmware image Windows 386 enhanced mode program information icon file for the program manager The directory may also contain files which are used for other operating systems. 4 Installation Note E4411-90026

4. Execute the desa1500.bat script with the selected RS-232 port as the parameter. For example, if you are using COM1 and working in DOS, the commands are: C:\ cd\esa_dnld desa1500.bat com1 If you are using Windows, you must execute desa1500.pif rather than directly executing desa1500.bat. Type com1 in the parameter message box. See the Appendix for a DOS directory setup example. 5. Follow the instructions as they are presented. When the following prompt appears, you must respond within five seconds to avoid a synchronization problem: Turn on the instrument NOW. When asked to press Return, this refers to the PC keyboard Enter key, not the Enter key on the ESA-Series spectrum analyzer. 6. Once the download starts, be patient. It will take several minutes to complete and requires no further user interaction. While the download is in progress, desa1500.ksh will show the communication that is taking place with the spectrum analyzer. What appear to be several (nonhighlighted) prompts will appear on the screen. These will be automatically answered by the desa1500.bat program. 7. When desa1500.bat completes and the spectrum analyzer is running the new firmware, disconnect the RS-232 cable. If the procedure fails (due to loss of synchronization, accidental loss of power, etc.), repeat the procedure, starting with Step 4. 8. On the spectrum analyzer, press System, Alignments, Align, Now, All. Wait for the alignments to complete. Troubleshooting Hints If the spectrum analyzer is in the wrong mode (for instance, bootrom mode), the download program will not detect this condition. If this occurs, you must reboot the computer by pressing the following three keys: Ctr Alt Del and repeat the procedure from Step 4. Installation Note E4411-90026 5

Installation Procedure: HP OmniBook PC Version This procedure uses an HP OmniBook PC to download new firmware into an ESA- Series spectrum analyzer. 1. Connect the computer to the spectrum analyzer. a. Connect the dsub end of the HP Palmtop serial cable to the computer RS-232 port. b. Connect the other end of the HP Palmtop serial cable to the service connector on the rear panel of the spectrum analyzer. The logo should face the left side of the spectrum analyzer, as viewed from the front of the analyzer. Typically, you would use the COM2 RS-232 port, but COM1 is acceptable if it is available. No other program can make use of this port at any time during the procedure. 2. Insert the firmware upgrade disk into the floppy drive of the computer. a. Create an empty directory called esa_dnld on the C:\ drive to unpack the self-extracting archive. b. Using MS Windows, go to File Manager and select drive (A:\ or B:\). The file desa1500.exe should be present. c. Copy desa1500.exe, to the esa_dnld directory on the C:\ drive: A:\copy desa1500.exe C:\esa_dnld d. Change to the C:\esa_dnld directory. e. In MS-DOS, type desa1500.exe and press Enter. In File Manager, double-click on desa1500.exe. 3. Verify that the following items were unpacked: readme.txt desa1500.bat split_dl.exe wait.exe esa1500.out desa1500.pif desa1500.ico these instructions script to perform the download the actual firmware image Windows 386 enhanced mode program information icon file for the program manager The directory may also contain files which are used for other operating systems. 6 Installation Note E4411-90026

4. Execute the desa1500.bat script with the selected RS-232 port as the parameter. For example, if you are using COM1 and working in DOS, the commands are: C:\ cd\esa_dnld desa1500.bat com1 If you are using Windows, you must execute desa1500.pif rather than directly executing desa1500.bat. Type com1 in the parameter message box. See the Appendix for a DOS directory setup example. 5. Follow the instructions as they are presented. When the following prompt appears, you must respond within five seconds to avoid a synchronization problem: Turn on the instrument NOW. When asked to press Return, this refers to the PC keyboard Enter key, not the Enter key on the ESA-Series spectrum analyzer. 6. Once the download starts, be patient. It will take several minutes to complete and requires no further user interaction. If the procedure fails (due to loss of synchronization, accidental loss of power, etc.), repeat the procedure, starting with Step 4. 7. When desa1500.bat completes and the spectrum analyzer is running the new firmware, disconnect the RS-232 cable. While the download is in progress, desa1500.ksh will show the communication that is taking place with the spectrum analyzer. What appear to be several (nonhighlighted) prompts will appear on the screen. These will be automatically answered by the desa1500.bat program. 8. On the spectrum analyzer, press System, Alignments, Align, Now, All. Wait for the alignments to complete. Troubleshooting Hints If the spectrum analyzer is in the wrong mode (for instance, bootrom mode), the download program will not detect this condition. If this occurs, you must reboot the computer by pressing the following three keys: Ctr Alt Del and repeat the procedure from Step 4. Installation Note E4411-90026 7

Installation Procedure: HP Palmtop Version This procedure uses an HP 200LX Palmtop computer to download new firmware into an ESA- Series spectrum analyzer. Table 2 Quantity Description Part Number 1 10 MB flash disk F1013C 1 HP connectivity pack (includes HP Palmtop serial cable, HP FL015A null modem adapter, and connectivity pack software, p/n 5181-6639. F1021B/C 1. Insert the firmware upgrade disk into a PC compatible computer disk drive. a. Create an empty directory called esa_dnld on the C:\ drive to unpack the self-extracting archive. b. Using MS Windows, go to File Manager and select drive (A:\ or B:\). The file desa1500.exe should be present. c. Copy desa1500.exe, to the esa_dnld directory on the C:\ drive: A:\copy desa1500.exe C:\esa_dnld d. Change to the C:\esa_dnld directory. e. In MS-DOS, type desa1500.exe and press Enter. In File Manager, double-click on desa1500.exe. When connecting the connectivity pack serial cable to the palmtop, make sure that the logo on the plug faces up. 2. Using the Palmtop connectivity pack software and hardware, download the upgrade firmware files from the C:/ drive of the PC to the Palmtop flash disk, into a directory named A:/esa_dnld. See the Appendix for a DOS file copy example. Refer to the HP Palmtop owner s manual for this procedure. 3. Verify that the following items were copied: readme.txt desa1500.bat split_dl.exe wait.exe esa1500.out desa1500.pif desa1500.ico these instructions script to perform the download the actual firmware image Windows 386 enhanced mode program information icon file for the program manager The directory may also contain files which are used for other operating systems. 8 Installation Note E4411-90026

4. Connect the Palmtop to the spectrum analyzer: a. Connect the dsub ends of the two HP Palmtop serial cables to the null modem adapter. (One cable is supplied with the firmware upgrade kit, and one with the connectivity pack.) b. Connect the remaining ends of the serial cables to the service connector of the spectrum analyzer rear panel, and to the HP Palmtop serial port. When connecting to the Palmtop serial port, make sure the logo faces up. When connecting to the service connector, make sure the logo faces the left side of the analyzer (as viewed from the front of the analyzer). Use the COM1 RS-232 port. No other program can make use of this port at any time during the procedure. 5. Use the following procedure to set up the HP Palmtop application manager: a. Press the Palmtop MENU key. b. Press A for application. c. Press A for add (The Add Application window appears). d. In the Name box, type ESA Download, and then press tab. e. In the Path box, type a:esa_dnld\desa1500.bat com1 250, and then press tab. (To type the symbol, hold down the Shift key and press \). f. In the Comments box, type (Fn, 3) and (Fn, Filer) then tab to the ICON box. These settings prevent the system manager from interfering with the download. The 250 entry in the path box provides sufficient DOS memory for the programs. 6. Within the Icon box, scroll by using the up arrow key to select the spectrum analyzer icon.if everything is correct, press F10 OK on the screen. This will activate the applications manager screen. The new application icon should be present. 7. To start the download program, select the spectrum analyzer icon and press enter. 8. Follow the instructions as they are presented. When the following prompt appears, you must respond within five seconds to avoid a synchronization problem: Turn on the instrument NOW. When prompted to press Return, this refers to the Palmtop keyboard ENTER key, not the similarly-labeled key on the ESA-Series Spectrum Analyzer. 9. Once the download starts, be patient. It will take 15 minutes to complete, and requires no further user interaction. While the download is in progress, desa1500 will show the communication that is taking place with the spectrum analyzer. What appear to be several (nonhighlighted) prompts will appear on the screen. These will be automatically answered by the desa1500.bat program. 10.When desa1500.bat completes and the spectrum analyzer is running the new firmware, disconnect the RS-232 cables. If the procedure fails (due to loss of synchronization, accidental loss of power, and so forth), repeat the procedure starting with Step 7. 11. On the spectrum analyzer, press System, Alignments, Align Now, All. Wait for the alignments to complete. Installation Note E4411-90026 9

Troubleshooting Hints If the spectrum analyzer is in the wrong mode (bootrom mode, for example), the download program will not detect this condition. If this occurs, you must reboot the computer by pressing the following three keys: Ctr Alt Del and repeat the procedure from Step 4. 10 Installation Note E4411-90026

Appendix Copying Files to a Directory Using DOS The PC MS-DOS command line example below shows how to create a new file directory on the PC hard drive and move the necessary files from the firmware upgrade disk into the new directory. 1. Go to MS-DOS and create this directory on the PC hard drive. a. C:\>md esa_dnld (make the directory called esa_dnld) b. C:\>cd esa_dnld (change to the esa_dnld directory) c. C:\esa_dnld> 2. Copy files into the esa_dnld directory. Press enter on the PC to transfer files. a. C:\esa_dnld> copy a: split_dl.exe b. C:\esa_dnld> copy a: desa1500.bat c. C:\esa_dnld> copy a: wait.exe d. C:\esa_dnld> copy a: esa1500.out e. C:\esa_dnld> copy a: desa1500.pif f. C:\esa_dnld> copy a: desa1500.ico Deleting Files Using MS Windows and DOS When the self-extracting archive is unpacked, the individual files might be marked as read-only. If you attempt to delete these files in MS Windows, the File Manager will warn you that the files are read-only, hidden, or system files. You will still be permitted to delete the files. In DOS, you must toggle off the read-only attribute before the files can be deleted. To do this, change to the directory containing the files to be deleted, then type ATTRIB -R *.* and press Enter. The files may then be deleted using the del command. Installation Note E4411-90026 11