ASPEN Software - Introduction

Similar documents
ASPEN Software - Introduction

Tutorials. Tutorial: Creating a New Case Page 1 of 13

What s New in Version 14 of ASPEN OneLiner/ Power Flow

A guide on PowerWorld Simulator ver. 12.0

POWER WORLD LAB MANUAL

University of California, Santa Cruz Baskin Engineering School Electrical Engineering Department

System Protection and Control Subcommittee

Small Generator Interconnection System Impact Study Report. Completed For Q0047

ETAP PowerStation 4.0

Power*ToolsR for Windows V8.0 Tutorial

ASPEN OneLiner Version 14.6 Update

PRC Coordination of Protection Systems for Performance During Faults

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc

Introduction to PowerWorld Simulator: Interface and Common Tools

Revised Generation Interconnection Impact Study Report. For. Queue Position 31 ( Interconnection Customer )

EPRI Protection Settings Evaluation Tool (PSET)

EE 868: Digital Techniques for Power System Protection. Laboratory Assignment #2 (Feb. 8 (12pm)) Overcurrent Relay Coordination

Short-Circuit Calculation Methods

ETAP PowerStation 4.0

ELG4125: System Protection

Transient Stability Analysis with PowerWorld Simulator

1. Coordination of series-rated devices is permitted where indicated on Drawings.

Generation Interconnection Impact Study Report. For. Interconnection Customer Q0022

Distribution Management System Open++ Opera v.3.2. User Manual

PowerWorld Tutorial. Yen-Yu Lee The University of Texas at Austin Jan 18, Updated December 26, 2012, by Ross Baldick

Standard Development Timeline

Power System Protection Training

PROCEDURE FOR TESTING P122 THREE PHASE OVERCURRENT & EARTH FAULT PROTECTION RELAY S.E.P TRAINING CENTRE

PRC 001 R6 & R7.3 TFO s Notification Requirement

Utility Implements Communications- Assisted Special Protection and Control Schemes for Distribution Substations

SolidWorks Intro Part 1b

i-pcgrid Workshop 2014 PG&E Order No. 754 Analysis: Protection

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9

IBM Integration Bus. Pattern Authoring Lab 1. June, 2013

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

DISTRIBUTION FEEDER FAULT ANALYSIS TILLAMOOK PEOPLE S UTILITY DISTRICT

INTERCONNECTION FACILITIES STUDY REPORT

Microgrids: Building Blocks of the Smart Grid Adaptive Protection Schemes for Microgrids

OpenOffice.org impress tutorial

Adding LPR printers on MacOS MacOS

Requests for Clarifications And Responses Order No. 754 Data Request The Study of Single Point of Failure

EDS LONDON 33KV DISTRIBUTION NETWORK DESIGN AND CUSTOMER SUPPLIES

Simplifying Wide Area Coordination of Directional Time Overcurrent Relays Using Automatic Settings Selection

SolidWorks 2½D Parts

Exercise 2. Single Bus Scheme EXERCISE OBJECTIVE DISCUSSION OUTLINE. The single bus scheme DISCUSSION

Commission Testing Methods for Protection Systems

LAB1 INTRODUCTION TO PSS/E EE461: POWER SYSTEMS COLORADO STATE UNIVERSITY

Generator Interconnection Impact Study Report Pamlico County, NC 200 MW Wind Farm Queue #281

DTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field

Modeling and Simulation in XENDEE

Common Departures Interconnecting Facilities Requirements

CSC258H: Logisim-Evolution Reference

Busbar protection REB 670

Getting Started Tutorial

Smart Distribution Technology

WHAT IS A BUS? FUNDAMENTALS OF BUS PROTECTION. Kevin Wright Senior Protection Engineer Sacramento Municipal Utility District

Distribution Management System Open++ Opera v.3.3. User Manual

We will discuss two types of loss-of-potential (LOP) logic during this presentation:

Disturbance Monitoring and

Intermediate Word for Windows

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

Application Techniques CENTERLINE 2100 Motor Control Centers

EMT1250 LABORATORY EXPERIMENT. EXPERIMENT # 6: Quartus II Tutorial and Practice. Name: Date:

1 Description of Methodology for Volt / Var Optimization

RecordGraph Template Application Note

SWITCHYARD SYSTEM BC1-SS-11-SD TRAINING SYSTEM DESCRIPTION NRG ENERGY, INC. BIG CAJUN 1

EPT 331 Advanced Manufacturing Technology LAB 2: CAM MILLING (Catia) 2008/2009 LAB 2: CAM MILLING

WinIGS. Windows Based Integrated Grounding System Design Program. Structural Dynamic Analysis Training Guide. Last Revision: February 2017

This application note describes configuring automatic bus transfer (ABT) logic with two V57 relays.

Blackstart Hardware-in-the-loop Relay Testing Platform

Simulating a Design Circuit Using Qsim

SAP Favorites. You can manage your own SAP menu Favorites in multiple ways: 1. From the SAP menu bar click on Favorites to display your options:

ADVANCED. Protection Co-ordination. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW

Standard Development Timeline

Power systems 5: Protection

Microsoft Word 2011 Tutorial

Tower Drawing. Learning how to combine shapes and lines

The Digital Substation: resilient and Cyber Secure Protection and Control

FINIST OPERATOR TRAINING SIMULATOR QUICK START REVISION 2.0 OF 01/18/2011

What s New in Version 5.00 Compared to Version 4.52

Field Device Database Editor User Guide <Virtual Environment> 5.9

DW DIGs Model Windows Tricks

How To Help Electronic Equipment Survive The Storm

General Guidance, Secondary Injection

Identify and understand the operation of common bus. After this presentation you will be able to: Identify common bus arrangements

STEP OUT OF THE ARC FLASH HAZARD ZONE

POWER FLOW ANALYSIS AND PROTECTION COORDINATION OF REAL TIME SYSTEM

GETTING STARTED TABLE OF CONTENTS

SIEMENS POWER SYSTEM SIMULATION FOR ENGINEERS (PSS/E) LAB2 INTRODUCTION TO SLIDER BINARY (*.sld) FILES

Equipment Short-Circuit Current Rating and Available Fault Current

Tutorial 8: Actual Market Data

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

Transmission Register PTO Admin User Manual. Version 1.0

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

Talking Sage 200. talkingsage200.wordpress.com Sage 200 Navigating the Desktop

CASE STUDY : Transient Stability Simulation Package

ECSE-323 Digital System Design. Lab #1 Using the Altera Quartus II Software Fall 2008

Auto-Sectionalizing Firmware Product Description, Information and Specification

IEEE PES Swiss Chapter Workshop: Microgrids Evolution and Integration in Modern Power Systems

Transcription:

ASPEN Software - Introduction ASPEN is a very user-friendly software package that is capable of doing load-flow and shortcircuit studies, as well as relay application and coordination. Its simple graphical user interface allows you to quickly draw the system one-line on the screen, and supply system parameters by simply clicking on the bus, generator, line, transformer, fuses, or circuit breaker of interest. Relays are associated with circuit breakers. One or more relays can be added on either side of the circuit breaker they monitor current flow through the circuit breaker and the voltage at that side of the circuit breaker. One of my graduate research assistants has recently learned ASPEN from scratch. His instructions for first-time users are given on the following page. A sample screen of a 9-bus system (Aspen9.olr) is given below.

Note: Aspen 2001 (academic version released June 2002) has been installed in the PCs in the 7 th floor computer lab and in the relay lab (SB19). Quick Start - Basic Procedure: 1. The shortcut icon may not appear on your desktop. Via Windows Explorer, locate C:\aspen01\OneLine and drag/create a shortcut on your desktop. Before running your first simulation, click on C:\aspen01\cfg1lpf.exe to configure Aspen. Leave all Library paths as-is, but choose HASP Key; Network Access for Key Type and Method of Access. After saving this setup, you are then ready to use the ASPEN OneLiner program by clicking OneLine shortcut that you have created on your desktop. 2. Help topics are available both in the manual and in the software, the ASPEN OneLiner manual (from earlier 1999 version) is on the shelf in the Edison lab in the sub-basement. On-line help is most up to date and easiest to use. Click on Help OneLiner Help Contents 2.8 One-Liner Quick Tutorial to learn how to draw and edit the one-line diagrams and use the GUI to enter parameters and run simulations. 3. All command references are at page 3-1 in the printed manuals, which will provide you with step-by-step instructions for drawing a system and editing parameters. On-line help is found in Section 3 of the help menu. Two sample systems can be opened and examined: Aspen9.olr and IEEE09.olr. 4. To begin a simple OneLiner diagram, we start with drawing a bus. Right click once and select the new bus commands input value on the bus names the nominal kv and choose real bus. ( pg. 3-33) 5. To add a generator on the bus, right click on the bus, choose new then generator. Enter the parameters of the generator, click ok and done. ( pg. 3-34 ) 6. Adding a line would require at least two buses. Click on one of the buses then with the Shift key held down, right click on the terminal bus. You will see a popup menu, choose new line. Input the parameter of the line, then click ok. You can always change the properties by double click on it. ( pg. 3-39 ) 7. Right click on the transmission line, choose new relay group. Depends on what kind of relay you want to insert to the line, OC for overcurrent relay and DS is for distance relay. ( pg. 3-49 ) 8. A fault can be placed on the transmission line. Right click on the relay that is connected with the desired fault location, the relay should be highlighted in red. Note that you shouldn t include the line when highlighting. Then choose Specify fault. You should have a menu of fault specification. Enter the desired fault, then click simulate.( pg. 3-119 ) 9. We can view currents and voltages in sequence or phase by clicking on the icons at the tools bar.

Assignment #6: Two time-overcurrent relays protect adjacent sections of a radial system. Bus 3 is at the end of the radial line. Approximately 7000 amps of fault current will flow for a close-in fault at point A and approximately 5000 amps of fault current will flow for a line-end fault at point B. Load current at bus 2 is 100A and load current at bus 3 is 350A. Both load currents are at unity power factor. Model this situation using ASPEN One Liner software and simulate the aforementioned faults. Observe the relay curves and the trip times. Investigate the phase and sequence voltages and currents for each bus and line after simulating both faults. Procedure: Setup: - In the file menu, choose New to start a new project. Choose 100 MVA as the system base. - Right click in the workspace and choose New Bus. The Bus Info pop-up menu should appear. Fill in the Name as Bus 1, the Bus no. as 1, the Nom. KV as 41.6, choose Real Bus for Bus Type and leave the rest the same. The buses can be moved by dragging them a round the workspace. Do this again for buses 2 and 3. - Click on Bus 1, hold down the shift key, and right click on Bus 2. Choose New Line. The Transmission Line Data menu should appear. Fill in the following spaces: Name=Line 1 Length=10 mi X=0.10025 X0=0.1. Leave everything else the same. Repeat this for the line between buses 2 and 3, which will be called line 2. However, use X=0.0774. Everything else should be the same as line 1. - Right click on line 1 near Bus 1 and choose New Relay Group. On the menu that appears, click on the Add OC Phase Relay button. Fill the spaces as follows:

ID=Relay 1 CT ratio=120 Time dial=4 Tap unit=gc2 Tap=4 Curve=CO-9 Make sure the directional option is NOT selected. Click OK, then Done. Do the same for line 2 near Bus 2, except for the following. ID=Relay 2 CT ratio=80 Tap unit=gc2 Time dial=0.5 Tap=5 Curve=CO-9 - Make sure directional option is NOT selected. - Right click on Bus 1. Choose new, then generator. The parameter menu for the generator will automatically appear. Use R=0 and X=0.1 for each impedance, include neutral impedance. The unit rating should be 100 MVA and the scheduled generation should be 100 MW. Leave the rest the same. Click OK, then Done. - Right Click on Bus 2. Choose New, then Load. The parameter menu for the load will automatically appear. Enter 0 MW for constant power, 7.2 MW for constant current, and 0 MW for constant Impedance. Repeat for Bus 3, except use 25.22 MW of constant current. Simulation: - Right click on the relay 2 and choose Specify Fault. Choose Close-in-Fault, no outage. Choose the 3LG phase connections. Deselect all other phase selections, since here we are only interested in a balanced 3-phase fault. Click Simulate. - On the toolbar, click on the clock icon to see the relay operating time and the fault current. - Repeat this for a line end fault with no outage. Make sure to de-select close-in-fault. Analysis: - By holding down the control key and double clicking on a line or bus, a graphical representation of the voltages and currents can be seen. - To see a text file of simulation results, click on TTY icon on the toolbar. - After simulating a fault, right click on the relay near Bus 1. Choose View Relay Curves and click OK. A graph of the time-overcurrent curve for relay 1 should appear. On the curve graph, click on the Add menu and select Relay Curves in Vicinity. Select Relay 2 from the window that appears and hit OK. The overcurrent curve for both relays should now be on the same graph. To see when the relays tripped, go into the Show menu and select Relay Operations for All Faults.