Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

Similar documents
Safety Switches CES-AR/CET-AR

INDUSTRY. Ongoing dialog. Communication at Industry 4.0 level

Non-Contact Safety System CES-AZ

Operating Instructions

Non-Contact Safety System CES-AZ

More than safety. Operating Instructions Non-Contact Safety Switch CES-AP-CR2-AH (Unicode) CES-AP-CL2-AH (Unicode)

More than safety. Operating instructions Non-contact safety system CES-A-AEA-02B/CES-A-AEA-04B (Unicode)

Safety Switches CES-AR/CET-AR

Product Overview Safety Engineering electronic

Magnetically Coded Safety Switches CMS

More than safety. Operating instructions Non-contact safety system CES-A-ABA-01/CES-A-ABA-01B (Unicode)

Non-Contact Safety System CES-AZ

Transponder-coded safety systems with external evaluation

Operating Instructions

Transponder-coded safety switches Interlocking devices and guard locking devices

Operating Instructions

Versatile and safe. Transponder-coded safety systems CES

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Transponder-coded. with guard locking

Operating Instructions

Operating Instructions

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

Non-Contact Safety System CMS. Magnetic Coding. More than safety.

Active face 57,5. Series Comment Version Order no. / item. Installation material 8-groove Bosch Installation material for CES-A-BSP

Safe switching and monitoring Non-Contact Safety Sensors

System family AR. Transponder-coded safety switch CET.-AR- With guard locking

More than safety. System Manual Safety System MGB-AR in combination with a locking module MGB-L1-AR-.../MGB-L2-AR-...

Online data sheet STR1-SASM03P5 STR1 NON-CONTACT SAFETY SWITCHES

Safety Switches with Separate Actuator, Metal Housing

Non-Contact Safety System CES-AZ

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Identification System CIS3A-Mini

Operating Instructions

Datasheet - CSS 11-30S-D-M-ST

Available coding options

More than safety. Operating Instructions Non-Contact Safety Switch CES-AR-CR2-AH (Unicode) CES-AR-CL2-AH (Unicode)

System family AP. Safety switch CET.-AP- With guard locking

Inductive proximity switches with long operating distance, series 500

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

Safety. Detection. Control. MAGNUS RFID ENG - REV

Online data sheet STR1-SAFM03P5 STR1 NON-CONTACT SAFETY SWITCHES

Datasheet - RSS 36-D-R-ST

More than safety. Operating Instructions Non-Contact Safety Switch CES-AR-C01-EH-SA (Fixcode)

Safe timer relay/contact expansion modules

Presentation. EUCHNER Multifunctional Gate Box MGB

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Safety coded magnetic sensor SR A series

Inductive sensor BI1.5-EG08-Y1-H1341

Non-Contact Safety Switch CMS. Magnetic Coding. More than safety.

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

More than safety. Product Overview. Safety Engineering

Online data sheet. TR4-SDM03P TR4 Direct NON-CONTACT SAFETY SWITCHES

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

ITEM ESM-BA301

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Technical Data. General specifications. Rated operating distance s n 3 mm

SR A series coded magnetic safety sensor

E-STOP relays, safety gate monitors

RoHS. High shaft load capacity. Shock / vibration resistant

E-STOP relay, safety gate monitor

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

SR B series coded magnetic safety sensors

Operating Instructions

Temperature Switches

Safety relays PNOZsigma

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Sensor boxes SRBG Key features

Connection of serial wired CTP-L1..-AR to Safety Relay ESM-BA..1

Online data sheet. IN30-E0407K IN3000 Direct NON-CONTACT SAFETY SWITCHES

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

Online data sheet. T40-E0101K T4000 Direct NON-CONTACT SAFETY SWITCHES

Inductive sensor BI1.5-EG08-Y1-H1341

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

E-STOP relays, safety gate monitors

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

PNOZ s1. Safety relays. Operating Manual EN-07

More than safety. Inductive Limit Switches

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

Two-hand control unit

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

PSEN 4.2a/b/p/M12. PSEN sensor technology. Operating Manual EN-02

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Safety module - PSR-SCP- 24DC/TS/S

MSR178DP. Description. Features. Specifications

Thread length (overall length) material

Safety switches for hinged doors

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Active Distributors AS-i Safety, Active Distributors AS-i

Inductive sensor NI3-EG08K-Y1-H1341

Technical Data Photoelectric Sensors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Rotary Measurement Technology Absolute Encoders, Singleturn

E-STOP relays, safety gate monitors

Transcription:

Non-contact safety system CES-FD- Evaluation of signals in the field Connection of CES read heads Connection to the ET200s and ET200pro Familiar EUCHNER AP interface Functional description Field evaluation units series CES-FD-AP make it possible to evaluate CES read heads in the field. The safety outputs on the field evaluation units are connected to the machine control. The system meets the following safety requirements: Safety category, PLe according to EN ISO 189-1 Redundant design of the circuit in the unit with self-monitoring This means that the safety system still functions even if an internal component fails The switch state of the semiconductor outputs is continuously monitored internally Short circuit detection at the safety outputs by clocked signals The following switch-on condition applies to the safety outputs FO1A and FO1B: Safety guard closed The system consists of three components: coded actuator (transponder), field evaluation unit and read head. The read head is connected to the field evaluation unit and reads the actuator code. Every EUCHNER actuator supplied has an electronic coding (unique coding) that is read by the read head. Only if a correct coding is detected does the system accept the actuator. The code in an actuator cannot be reprogrammed. Unlike systems with unique code detection, on multicode systems a specific code is not requested but instead it is only checked whether the actuator is of a type that can be detected by the system (multicode detection). There is no exact comparison of the actuator code with the code defined in the safety switch (unique code detection). The read head is fastened to the fixed part of the safety guard. The actuator attached to the movable part of the safety guard is moved towards the read head by closing the door. The read head is connected to the field evaluation unit. When the switch-on distance is reached, power is supplied to the actuator by the read head by induction and data can be transferred. If a permissible code is detected, the safety outputs are released. Due to the combination of dynamic polling of the actuator and the redundant, diverse design of the safety electronics with the two feedback safety outputs, the safety switch will enter the safe state with every detectable fault. When the safety guard is opened, the safety outputs switch off the safety circuit and the monitoring output OD is switched off. The state of the safety outputs is monitored internally by two microprocessors. If faults are detected, the safety circuit is switched off and the DIA LED illuminates. In case of devices with a monitoring output OI, the output is switched on. The field evaluation unit has a redundant switching design with selfmonitoring. This means that the safety system is still effective even if a component fails. The system is designed so that failures will not result in the loss of the safety function. The occurrence of failures is detected by cyclic selfmonitoring at the latest on the next demand to switch on the safety outputs (e.g. on starting). If the safety door with the actuator should settle over time, the actuator can drift out of the read head operating distance. The device recognizes this situation and indicates that the actuator is in the limit range. This allows the safety door to be readjusted in time. Your advantages Maximum safety with cat. /PLe Minimal wiring effort Small space requirement No additional DIN rail mounted evaluation unit required Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC decentralized periphery e.g. ET 200pro DI 2 1 5 UB 1 FO1A 2 0V FO1B X1: M12 plug-connector (5-pin) CES-FD-AP-...-.SI-... 1 n.c. 5 2 5 Connection example: Version for connection to decentralized peripheral equipment DO Connection to safe control systems or safety relays Do not use a control system or safety relay with pulsing for monitoring short circuits or switch off the pulsing function in these devices. The switch generates its own clock signals on the output lines FO1A/FO1B. A downstream device must tolerate these test pulses, which may have a length of up to 0. ms. The inputs on the downstream device must be suitable for positiveswitching devices (pnp outputs), as the two outputs on the safety switch deliver a level of +2 V in the switched-on state. CES-FD 77

Field evaluation unit 1 Cat. PLe CES-FD-AP-.-01-USI- No series connection Pulsing for short circuit detection Available in the unicode and multicode variants (see page 82) 78

Read head Actuator CES-A-LMN-SC Cylindrical design M12 M8 plug connector (see page 8) CES-A-BMB Cylindrical design M12 (see page 86) CKS-A-L1B-SC-1110 Key adapter for installation in control panels M8 plug connector (see page 87) CKS-A-BK1-RD-1161 Key for key adapter CKS (see page 87) 79

1161 FR Safety System CES-FD Component overview for the non-contact safety system CES-FD Extension cables Field evaluation unit Read heads Actuator Bolt CES-A-LMN-SC CES-A-BMB - CES-FD-AP-.01--USI- page 8 page 86 page 82 page 82 CKS-A-L1B-SC-1110 CKS-A-RD-1161 CKS - page 87 page 87 80

Possible combinations for CES components To give you a quick overview of which CES components can be combined with each other, there is a combination table for each evaluation unit and for each safety switch. The table will answer the following questions: Which actuator can be read by the selected safety switch? What is the operating distance of this combination? Which type of guard locking can be realized with the selected combination? Important: Only typical values are listed in the table. The minimum and maximum values are listed in the technical data for the related product. 15 Combination possible, typ. switch-on distance 15 mm Key to symbols Combination possible, guard locking for process protection Combination possible, guard locking for personal protection Combination not permissible Non-contact safety switches CES-FD Actuator Field evaluation unit Read head CES-A-BMB 077791 CKS-A-BK1-RD 1161 CES-FD-AP-.-01-USI- CES-A-LMN-SC 077790 CKS-A-L1B-SC 1110 5-81

Field evaluation unit CES-FD-AP- Evaluation of signals in the field Connection of CES read heads Connection to the ET200s and ET- 200pro Familiar EUCHNER AP interface Field evaluation unit CES-FD-AP- Dimension drawing Connection cable for control system with M12 plug connector, 5-pin Connection cable for read head with M8 plug connector, -pin Cat. PLe Cable length: 1,000 mm 0 12-0,2 Cable length: 200 mm For possible combinations see page 81 6,5 95 LED status indication,5 Fastening lug with reinforcement plate Short circuit monitoring The switch generates its own clock signal on the output lines FO1A/FO1B. Pay attention to this aspect when connecting to control systems and relays. Z 11 19,5 0 X Available coding options (see page 5) Unicode evaluation Multicode evaluation Category according to EN ISO 189-1 Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for: Category / PL e according to EN ISO 189-1 Important: To achieve the stated category in accordance with EN ISO 189-1, both safety outputs (FO1A and FO1B) must be evaluated. LED indicator STATE Status LED DIA Diagnostics LED M12 plug connector 5-pin 2 Coding lug 1 5 5,5 75 +0,5 85 0 Pin Designation Description Wire color 1 H1 Data wire BN H2 Data wire WH SH Screen - 5-pin Pin 5-pin, pin 5 not used 6 M8 plug connector, -pin 1 Designation Description Wire color 1 1 UB Power supply DC 2 V BN 2 2 FO1A Safety output, channel 1 WH 0V Ground DC 0 V BU FO1B Safety output, channel 2 BK 5 - OD Monitoring output GY +UB 0V FO1A FO1B OD X1.1 X1. X1.2 X1. X1.5 +UB 0V FO1A FO1B n.c. X1.1 X1. X1.2 X1. X1.5 Safety screws see page 89. Connection cables see page 156 ff. Ordering table Series CES-FD-AP-U-01- Unicode CES-FD-AP-M-01- Multicode Connection cable with M12 plug connector, 5-pin Category and PL acc. to EN ISO 189-1 / PL / PL Extension for read head cable with M8 plug connector, -pin Version Connection cable with M12 plug connector, pin 5 not assigned Connection cable with M12 plug connector, pin 5 not assigned Order no./item 119865 CES-FD-AP-U-01-USI-119865 1155 CES-FD-AP-M-01-USI-1155 5 m, PVC 10018 10 m, PVC 10018 20 m, PVC 100185 0. m, PUR 1156 82

Technical data for field evaluation unit CES-FD-AP- Parameter Value min. typ. max. Unit Housing material Plastic PBT Dimensions 95 x 0 x 12 mm Mass 0.0 kg Ambient temperature at U B = DC 2 V - With connection cable with M12 plug connector - Connection cable laid rigidly -20 - +65 - Connection cable movable -0 - +65 Storage temperature -20 - +70 Degree of protection IP67 Safety class III Degree of contamination Installation position any Connection - Evaluation - Read head Operating voltage U B (reverse polarity protected, regulated, residual ripple < 5%) Connection cable with plug connector M12x1, 5-pin Connection cable with plug connector M8x1, -pin 2 ± 15% (PELV) V DC Current consumption 5 ma Switching load according to DC 2 V, class 2 External fuse (operating voltage) 0.25-1.5 A Safety outputs FO1A/FO1B Semiconductor outputs, p-switching, short circuit-proof - Output voltage U(FO1A)/U(FO1B) 1) HIGH U(FO1A) U B -1.5 - U HIGH U(FO1B) B V DC LOW U(FO1A)/U(FO1B) 0 1 Switching current per safety output 1-150 ma Utilization category according to EN 6097-5-2 DC-1 2 V 150 ma Caution: outputs must be protected with a free-wheeling diode in case of inductive loads. Off-state current I r 0.25 ma Monitoring output OD 2) Semiconductor output p-switching, short circuit-proof - Output voltage 0.8 x U B - U B V DC - Max. load - - 50 ma Rated insulation voltage U i - - 75 V Rated impulse withstand voltage U imp - - 1.5 kv Resilience to vibration acc. to EN IEC 6097-5-2 Switching frequency - - 1 Hz Repeat accuracy R 10 % EMC protection requirements according to EN 6097-5- Reliability values according to EN ISO 189-1 Category Performance Level (PL) e PFH d.5 x 10-9 / h Mission time 20 years 1) The device tolerates voltage interruptions of up to 10 ms. 2) Values at a switching current of 50 ma without taking into account the cable lengths. C 8

Read head CES-A-LMN-SC Cylindrical design M12 M8 plug connector (snapaction and screw terminals) Read head CES-A-LMN-SC M8 plug, -pin Dimension drawing Read distance s 5 in inserted state 17 2 1) 19,7 M 12x1 m For possible combinations see page 81 Attention: The operating distance may vary depending on the substrate material and installation situation. Center offset 5 1) 8 0 M8x1 Active face Important: Actuators must be ordered separately! See page 86. 1) Metal-free zone 7 For connection cable see page 82 Terminal assignment Typical operating distance Y 8 Screen BN WH H11 H12 SH1 CES-AZ 1 Read head 8 6 2 6 8 X 6 2 6 2 6 8 Z 8 A minimum distance of s = 1.2 mm must be maintained. Ordering table Series Connection Version Order no./item CES-A-LMN-SC SC M8 plug connector Housing M12 077790 CES-A-LMN-SC 8

Technical data for read head CES-A-LMN-SC (in combination with CES-FD) Parameter Value Unit min. typ. max. Housing material Nickel-plated CuZn housing sleeve Plastic PBT GF20 cap Dimensions M12 x 1, length 8 mm Mass 0.2 kg Ambient temperature C - CES-A-LMN-SC -20 - +70 Ambient pressure (only of active face in installed condition) - - 10 bar Degree of protection IP67 Installation position Any Method of operation Inductive Power supply Via evaluation unit Cable length - - 0.7 m In combination with actuator CES-A-BMB Operating distance for center offset m = 0 1) - Assured switch-off distance S ar - - 10 Cable length l = 0 to 15 m - Switch-on distance - 5 - - Assured switch-on distance S ao. - - - Switching hysteresis 0.05 0.2 - Connection M8 plug connector (snap-action and screw terminals), -pin 1) These values apply to surface installation of the read head in steel. mm 85

Actuator CES-A-BMB Cylindrical design M12 x 0.75 Actuator CES-A-BMB Dimension drawing 0,80 M12x0,75 11 6 Active face For possible combinations see page 81 Insertion tool 12, +0,12-0,06 Insertion tool With the aid of the insertion tool, the actuator CES-A-BMB (cylindrical design) can be screwed into a prepared M12 x 0.75 thread in the safety door. t = 0,6 11,1 +0,12-0,06 1,5 15 Ordering table Series Comment Version Order no./item CES-A-BMB 077791 CES-A-BMB Insertion tool For actuator CES-A-BMB 07662 Technical data Value Parameter Unit min. typ. max. Housing material Stainless steel Dimensions M12 x 0.75, depth 6 mm Mass 0.002 kg Ambient temperature -25 - +70 C Ambient pressure (only applies if the pressure acts on all sides of the actuator) - - 10 bar Degree of protection Installation position Power supply IP67 Active face opposite read head Inductive via read head 86

Key adapter CKS Key adapter with integrated CES read head LED indicator Simple connection via M8 plug connector High degree of protection IP67 Key adapter CKS Dimension drawing 0 LED Key adapter 70,5 max. mm Plug connector M8 8 75 76 67 For possible combinations see page 81 8 M 1,5 (Rubber seal) Screw clamp element 50 10 8 2 Cable outlet, angled plug connector For connection cable see page 82 Key CKS Important: Key adapter CKS must not be used as a lockout mechanism in combination with multicode evaluation. The key is not included with the key adapter and must be ordered separately. Dimension drawing 0 1161 CKS FR 25, 1 Active face (front and rear sides) 5 Wiring diagram BN WH 1 H11 H12 SH1 View of M8 plug connector of key adapter Evaluation unit CES Ordering table Series Version Order no./item CKS-A-L1B-SC-1110 CKS-A-BK1-RD-1161 Key adapter CKS (including screw clamp elements) Key CKS (color red) 1110 CKS-A-L1B-SC-1110 1161 CKS-A-BK1-RD-1161 87

Technical data for key adapter CKS (in combination with CES-FD) Parameter Value min. typ. max. Unit Key adapter Housing material Plastic (PA 6 GF0) Mass 0.1 kg Ambient temperature -20 - +70 C Degree of protection according to IEC 60529 IP67 (in installed state) Installation position On the front Mounting cut-out according to DIN 700 x 68 mm Operating distance 1) Assured switch-off distance s ar - - 5 mm Assured switch-on distance s ao 2 - - Switching hysteresis - 1 - Connection to evaluation unit Plug connector M8 (male socket, -pin) Cable length - - 0.7 m LED indicator white: valid key detected Key Housing material Plastic (PC) Mass 0.00 kg Degree of protection according to IEC 60529 IP67 Ambient temperature -20 - +70 C Power supply Inductive via read head 1) Referred to the stop of the inserted key 88

Safety screws Ordering table Fixing material/ screw size Safety screws M x 1 (large head) Version/usage Field evaluation unit CES-FD-AP-M-01-USI-1155 Packaging unit [qty.] Order no. 100 08622 89