DATA SHEET DVI - HDCP Extension Cable

Similar documents
DATA SHEET DVI - HDCP Extension Cable

DATA SHEET DVI - HDCP Extension Cable

DATA SHEET. Optical Graphic Extension Module-Fibres Detachable

DATA SHEET. Optical Graphic Extension Module-Fibres Detachable

DATA SHEET. Optical DVI/USB/RS232/Audio Extender M5-1003

DATA SHEET. Two (2) PCs Switchable Dual-head DVI Optical KVM Extender, KVMX-100-TR

1-Fiber Detachable DVI module, DVFX-100

1-Fiber Detachable DVI module, DVFX-110

DATA SHEET. Optical HDMI Extension Module M1-2R2H-TR

2-Fiber Detachable Dual Link DVI module, DDFX-100

1-Fiber Detachable DVI module, DVFX-110

DATA SHEET. Dual-display supportable HDMI / DVI IP KVM Extender IPKVM-350-ED OPTICIS HQ. Headquarters

DATA SHEET. Wireless Extender for HDMI, Keyboard and Mouse HDWX-100-TR

DATA SHEET. 16x16 Multicast supportable HDMI/DVI IP KVM Extender IPKVM-310-ED

DATA SHEET. HDMI Active Optical Cable, HDFC-100

DATA SHEET. DisplayPort1.2 Active Optical Cable DPFC-200D. Contents

DATA SHEET. Contents. M2-100 (Ver. 3.3)

Stratos DVI Fiber Optic Extenders

DXF-200 DVI/HDMI Optical Extension System

Digital Video/Audio Optical Extender User s Manual

Digital Video/Audio and Serial I/O Optical Extender. User s Manual for the M5-2A2-TR. Manual Contents.

DVI Dual Link Extender via MPO Fiber Self-EDID Programming Up to 500m in one Multimode Fiber

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

DisplayPort Active Optical Cable (UPO) OVERVIEW

HDMI and Ethernet Extender via 2 Multimode Fibers LC Duplex Connector Extends HDMI+ 10/100M Ethernet Link Up To 800 Meters

Two (2) fibers Detachable HDMI Extender

DVI Extender via 4 fiber channel LC Duplex Connector Self-EDID Programming Extends DVI connection up to 500 meters

KVM Extender via 2 Multimode Fibers LC Duplex Connector Extends DVI + USB 2.0 Link Up To 200 Meters

Optical VGA/Audio/RS-232 Extender User s Manual AVFX-100-TR

DVI Extender over single LC Fiber with TMDS video and EDID data.

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 5 kilometers

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

ST-2FODVI-LC DVI Extender via Fiber Optic Cable Installation and Operation Manual

UHD-120 Owner s Manual 1 x 2 4K HDMI Distribution Amplifier

DVI Extender via Duplex LC Fiber Self-EDID programming Up to 1500m in single mode fiber & 500m in multimode fiber

Stretch FireWire TM. User s Manual M4-200 & 201. Manual Contents.

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

User s Manual. 2-Fiber Detachable Dual Link DVI module, DDFX-100. Manual Contents.

DVI Extender via 2 Multimode Fibers LC Duplex Connector Extends DVI + USB + Audio Link Up To 800 Meters

Stretch HDMI TM. User s Manual HDFC-100. Doc No. : OEC-H M1 / Rev1.1

Optical DVI Dual Link Extension Module

PDD-300 pulsed diode driver

H-series (Rectifier Module)

Express All-Fiber DVI. User s Manual (For M1-1000)

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

DVI/USB/RS-232 and Audio Optical Extender. User s Manual for the M Opticis Locations. Headquarters

ACE PLUS CORP. DVIE003. Description. Features. Application. Application

Kramer Electronics, Ltd. USER MANUAL. Models: 621T, DVI Optical Transmitter 621R, DVI Optical Receiver

Optical DVI Module. User s Manual M1-2R2-TR. Doc No. : OEB-D R2 / Rev2.6

SPECIFICATION. Preliminary. TFT-LCD Monitor TITLE. Signature Date Prepared by Date

Four (4) fibers Detachable HDMI Extender

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

ME to 30W Single Output External Power Medical Series. Features

Safety Standards. Model Number:

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

User s Manual. 2-Fiber Detachable Dual Link DVI module, DDFX-100. Manual Contents.

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

RT12-240V/2.4kW Rectifier Specification

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

TM221CE24R controller M IO relay Ethernet

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Wireless HDMI Extender, HDWX-100-TR

Safety Standards. Model Number:

DisplayPort+HDMI Extender via Single Multimode Fiber SC Connector Extends DisplayPort + HDMI Link Up To 500 Meters

LPS. ME20 20W Single Output External Power Medical Series. Features

TM221CE40T controller M IO transistor PNP Ethernet

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

User s Manual. Multi-format to 1-fiber DVI converter, OMVC-200. Manual Contents.

Media Converters. Media Converters. Product Selection Guides

User s Manual. VGA to 1-fiber DVI converter, VGDF-200. Manual Contents. dpd

Safety Standards. Model Number:

Safety Standards. Model Number: Unit Weight:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

HDMI Extender SET over Single Fiber Optic Cable with EMI Shielding

DVI Single-link Extender via 4 Multi-mode fibers 4xLC Connector Extends DVI Single-link Video+Full-Duplex RS232+Audio up to 500 meters

2x8 HDMI 1.3 over Single CAT5 Distribution Amplifier

Optical DVI Dual Link Extension Module

All-Optical Cable for Electrical Isolation. User s Manual (For M1-1000) Doc No. : OEC-D M / Rev2.3

Safety Standards. Model Number:

User s Manual (For M1-201SA-TR)

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: 622T Dual Link DVI Optical Transmitter. 622R Dual Link DVI Optical Receiver. P/N: Rev 4

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

Constant Voltage Mode

48V 1.5KW 1U AC-DC Power Supply Electrical Specification for: Telkoor Model: 0/ 7 SHEET 1 OF 1

EXTENDER ELE8081. INSTALLATION Manual. Made in Taiwan

Safety Standards. Model Number:

TO65DS. 65" TOTEM Displays

1-Fiber Detachable DVI module, DVFX-100

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

TM221M16R controller M IO relay

USER MANUAL. 621T DVI Optical Transmitter. 621R DVI Optical Receiver MODEL: P/N: Rev 8

Universal Power Supplies

CompuScope Ultra-fast waveform digitizer card for PCI bus. APPLICATIONS. We offer the widest range of

SP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan

TCF-142 Quick Installation Guide

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

Transcription:

M1-100x (Ver. 1.3) DATA SHEET DVI - HDCP Extension Cable M1-100x-xx Contents Description Features Absolute Maximum Ratings Recommended Operating Conditions Electrical Power Supply Characteristics Receiver Electrical Interface Specifications of fiber-optic cables Drawing of transmitter and receiver modules DVI Pin Description Reliability Test of Modules Terminology OPTICIS HQ Opticis Co., Ltd. # 16Fl, Kins Tower Jeongja 331, 8 Sungnam-daero, Bundang-gu Sungnam-si, Gyunggi-do, 463-782 South Korea Te l: +82 (31) 719-8033 Fax: +82 (31) 719-8032 tosales@opticis.com Copyright 2015, All rights reserved, Opticis Co., Ltd. 02, Jan. 2015

Description Optical DVI - HDCP Extension Cable * Point-to-point optical fibre cable * The reality of gigabit high-speed digital graphic interconnections mandates products that maintain front-of-screen video quality. Optical technology extends the ability to transmit digital graphic data beyond the physical limits of copper wires by, i) providing pure signal integrity over long distances for the optimum visual experience, ii) no EMI/RFI transmission or reception, iii) light weight, rugged cabling and connectors, iv) very cost effective per foot/metre, v) low power consumption, and vi) plug and go installation ease no software requirements. The M1-100x consists of a transmitter and a receiver, connected by all fiber-optic distribution cables with male DVI-D connectors at each end. The Transmitter and Receiver modules are respectively implemented by Opticis designed and manufactured 850nm VCSEL and PIN-PD arrays. The M1-100x product makes DDC / HDCP interconnection over pure fibers as well as transmission of the Red, Green, Blue, and Clock TMDS graphic data over fibers. The cable can be any length up to 100m (328ft) for 2K resolution or 500m (1640ft) for WUXGA (1,920x1,200) 60Hz data. An external power is required for the receiver module, while most video cards, at least 500mA of +5V voltage can provide DC power to the transmitter module. The shipping group is as follows; 1) One DVI / HDCP cable: M1-100x-yyy, where x = C, 0 (Zero), and y = length in metres. x = C : Designed to send DDC clocks not only from PC, but also from display, having capability generating DDC clocks for a special purpose (like DDCAB : Access Bus) 0 : Designed to send DDC clock in unidirectional from PC to display 2) Factory will stock standard lengths of 10m, 20m, 30m and 50m. 3) User Manual - 1 -

Feature Supports all VESA resolutions up to 2K or WUXGA (1920x1200), at 60Hz refresh rate with 1 pixel/clock mode. Embeds pure fiber distribution cable with 8 strands Multimode Glass of fibers not only for the TMDS video interface and but also to support the DDC2B/HDCP, which offers perfect electrical isolation. Extends up to 500 meters (1,640 feet). Applicable of both powers from graphic cards and an external adaptor for the transmitter while powering the receiver from an external +5V adaptor. Compact end connector design easily allows direct connect to the host video card and display peripheral. No software to install; just plug and go. Data security with negligible RFI/EMI emissions\ Certifications: FCC / CE Applications Digital display system integration for medical, military, aerospace, factory automation, and traffic control platforms. Digital FPD, PDP and projector installation in conference rooms, auditoriums and for kiosk systems LED signboards for large scale information display and stadiums Home Theatre Systems - 2 -

Absolute Maximum Ratings Parameter Symbol Minimum Maximum Units Storage Temperature T stg - 30 + 70 C Supply Voltage V CC - 0.3 + 6.0 V Transmitter Differential Input Voltage V d - 1 V Humidity RH 10 85 % Lead Soldering Temperature & Time - - 260 C, 10 sec Recommended Operating Conditions Parameter Symbol Minimum Typical Maximum Units Ambient Operating Temperature T A 0 + 50 C Data Output Load R LD 50 Ω Power Supply Rejection (Note1) PSR 50 mv p-p Supply Voltage V CC + 4.5 + 5.0 + 5.5 V Graphic Supply Voltage (Note2) GV CC + 3.0 + 3.3 + 3.6 V Note1. Tested with a 50mV p-p sinusoidal signal in the frequency range from 500 Hz to 500 MHz on the V CC supply with the recommended power supply filter in place. Typically less than a 0.25 db change in sensitivity is experienced. Note2. Graphic Supply Voltage is only for the Graphic Signal Interface, which is generated by regulator in the Transmitter and Receiver Electrical Power Supply Characteristics (T A = 0 C to +50 C, unless otherwise noted) Parameter Symbol Minimum Typical Maximum Units Supply Voltage V CC 4.5 5 5.5 V Supply Current TX I TCC - 180 200 ma RX I RCC - 180 200 ma Power Dissipation TX P TX 0.9 1.1 W RX P RX - 0.9 1.1 W - 3 -

Specifications of Fibre-Optic Cables Parameter Value Parameter Value Core Diameter 62.5±3.0um Cladding Diameter 125±2.0um Coating Diameter 245±15um Outside Diameter 5.5±0.2mm Proof Test Level > 100kpsi Drawing of transmitter and receiver modules Dimension [mm] - 4 -

DVI Pin Description Pin Symbol Functional Description 1 CH2- TMDS Data Signal Channel 2 Negative 2 CH2+ TMDS Data Signal Channel 2 Positive 3 GND TMDS Data Signal Channel 2 Shield 4 5 6 DDC Clock DDC Clock line for DDC2B communication 7 DDC Data DDC Data line for DDC2B communication 8 N.C. 9 CH1- TMDS Data Signal Channel 1 Negative 10 CH1+ TMDS Data Signal Channel 1 Positive 11 GND TMDS Data Signal Channel 1 Shield 12 13 14 5 V 5 V Input for Transmitter from Host 5 V Output for Monitor from Receiver 15 GND Ground 16 Hot plug Detect 17 CH0- TMDS Data Signal Channel 0 Negative 18 CH0+ TMDS Data Signal Channel 0 Positive 19 GND TMDS Data Signal Channel 0 Shield 20 21 22 GND TMDS Clock Signal Shield 23 CLK+ TMDS Clock Channel Positive 24 CLK- TMDS Clock Channel Negative Note: Channels 3, 4 and 5 dual-link data signal pins are not used Signal is driven by monitor to enable the system to identify the presence of a monitor - 5 -

Reliability Test Opticis utilizes three types of test criteria for a reduction of variability and a continuous improvement of the process by its FEMA (Failure Mode and Effective Analysis) program. 1) Mechanical test (vibration, shock) 2) Temperature & humidity tests 3) EMC test (FCC class B and CE Verification) Mechanical and Temperature & Humidity Test Data Heading Test Conditions Duration Operating Test Storage Test Mechanical Test Operating at each Temperature (See Note) * -10 ~ 70 C (Interval: 10 C) 30 Min (Each Temperature) Sample Size Failure n =3 0 Remarks Note: Visual Test on the Display Low Temperature * T S = -30 C 96 HR n=3 0 1. TS: Storage Temperature High Temperature * T S = 80 C 96 HR n=3 0 2. RH: Relative Humidity High Humidity High Temperature Mechanical Shock Mechanical Vibration * T S: 85 C * RH: 85% * Pulse: 11 ms * Peak level: 30 g * Shock pulse: 3 times/axis * Peak acceleration: 20 g * Frequency: 20~2000 Hz * Sweep time: 30 Minutes * 4 Times/Axis 96 HR n=3 0 - n=2 0 - n=2 0-6 -

EMC Test Data 1) EMI: Meet FCC class B (ICES-003) and CE class B STANDARDS CONDITIONS EN 55 022 (CISPR22) CE (Conducted Emission) & FCC; PART 15 SUBPART B RE (Radiated Emission) Meet Class B EN 61000-3-2 (IEC 61000-3-2) Harmonics Meet Class B EN 61000-3-3 (IEC 61000-3-3) Flickers Meet Class B 2) EMS: Meet CE standards (EN 55024) and CISPR24 equivalents STANDARDS CONDITIONS EN 61 000-4-2:1995 Electrostatic Discharge Immunity (Air: 8kv, Contact: 4kv) Meet Criterion A EN 61 000-4-3:1996 Radiated RF E-Field (80~1000 MHz) 3V/m (AM 80%, 1kHz) Meet Criterion A EN 61 000-4-4:1995 Fast Transients (5kHz, 60Seconds) Meet Criterion A EN 61 000-4-5:1995 Surge Transients Meet Criterion A EN 61 000-4-6:1996 Conducted Susceptibility (CS) Radiated Susceptibility (RS) Meet Criterion A EN 61 000-4-11:1994 Voltage Dips, Interruption & Variation Meet Criterion A and C Terminology DDC DVI-D EDID EMI EMS HDCP PDP RFI TFT-LCD TMDS VCSEL VESA Digital Display Channel. Latest specification is DDC2B. Digital Visual Interface. Digital connection only no analog. Extended Display Identification Data. EDID parameters are sent over the DDC link. Electro Magnetic Interference. Electro Magnetic Susceptibility. High Definition Content Protection. These parameters are part of the 2002 High Definition Multimedia Interface (HDMI) specification for Consumer Electronics. Plasma Display Panel. Large HDTV panels up to 63 use this display technology. Radio Frequency Interference. Thin Film Transistor Liquid Crystal Display the technology of most computer display panels with VESA resolutions up to 1600x1200 pixels. Transmission Minimized Differential Signalling is the Silicon Image Inc. protocol for the digital signals. Vertical Cavity Surface Emitting Laser transmitter diode. The receiver diode is the PIN-Photo Diode. These components are designed and manufactured by Opticis. Video Electronics Standards Association. - 7 -