Golden Dog Manual. Golden - Dog. Manual

Similar documents
QMaster- Senior Automatic Temperature Control

OK - Functions of the buttons. = "Arrow up" = ON / OFF. = Enter. = Temperature. ="Arrow down" = Preset time / Start time.

Operation manual for

SITC 15 Temperature Controller Operator s Manual

Athena Series RMC Hot Runner Controller Configuration and Operation Manual

OPERATION INSTRUCTIONS

Basic control panel. Features. Control panels 75

Instruction Manual HID-2

ExactLogic BACnet Communicating Thermostat EXL01716 Sequence Datasheet Duel Deck VAV

Venstar Thermostat Adapter

Analyzer/Sensor to measure UV Spectral Absorbance

Digital Air Velocity Meter DC580. The Value Leader TM

SMTmax SMT-6000 IR Preheating Plate

Gavita Master Controller EL1

4801P ph/orp controller

Model: Available in : Sapphire Black and Glacier White

ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet

Manual. Meter for BlueSolar DUO 12/24V-20A For RVs, Caravans and boats

MicroTrans EQ Signal Processor. Operation & Maintenance Manual

Gavita Master Controller EL1F

ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet

Model: Available in : Sapphire Black and Glacier White

Series SD-3PB Digital THERMOSTAT + TIMER

PosiTector DPM. Dew Point Meter. INSTRUCTION MANUAL v Simple. Durable. Accurate.

ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

CR-40ATA - CR-60ATA CR-40ATAV CR-40AT CR-60AT CR-40ATV

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

Operation Guide CT100

Class 220 KISTOCK. KT 220, KH 220 and KTT 220

Athena RMB/6 and RMB/12 Non-Modular Hot Runner Controller Configuration and Operation Manual

How to Electrical Calibration

AmegaView Software Release Notes

User Manual Version

FilterQuick/OCF Statistics Check and Error Log

Dresser * MeterWare Software Manual

Touchscreen Programmable temperature and humidity controller. OYO9256P WEWON Users Operating Instructions

ReefKeeper Lite User Guide 1.10+

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart.

Digital Controller Instructions

BASIC OPERATION OF L&L KILNS WITH A DYNATROL

Factory Packaged Controls. MODGAS-X Controller Field Technical Guide

Operations Manual EcoSense ph100a

Operations Manual. Solstice I12 Cooking Computer. Covering. Single Vat (P/N ) and Dual Vat (P/N )

C F MAX MIN TEMP:-20 C~ 60 C -4 F~140 F HUMIDITY: 0 ~ 100RRH HOLD TIMER T2 T1 RS-232 DC9V. h:m:m:s HUMIDITY TEMPERATURE METER POWER - UP OPTIONS

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

USER GUIDE. Differential Thermometer Datalogger. Model HD200

SERIES C 1ZC 16C 18C 19C 25C

INSTRUCTION PACKAGING CONTENTS

AE25-DPP OPERATION INSTRUCTIONS

ThermoPad Reference Manual

IMPROVED HARDWARE FEATURES

GENERAL INSTRUCTION GUIDE HONEYWELL UDC 1200 & 1700 PROCESS & 120L LIMIT CONTROLLERS


Electrical & Controls. September 28, 2017

Gavita Master Controller EL2

Model Instruction Manual. Heat Stress Meter. reedinstruments. www. com

FLAMEBOSS 300 MANUAL

EHC-WF. User/Technical Manual. Contents subject to change without notice

INSTALLATION & USER MANUAL

ULTRASTAT23 Operating Instructions For the MEC-110 with ENHANCED SMS 10-Product Cooking Controller

HI HI N HI HI

USER MANUAL AD 3000 EC/TDS/Temperature Bench Meter

Contents. 1. Safety information 1 2. Description 2 3. Specifications 6 4. Operating instruction 8 5. Accessories 12

Instruction Manual HI 2550 Multiparameter ph/orp/ C EC/TDS/NaCl Bench Meter

SPECIFICATIONS Temperature Setting Range: Ambient Temperature Humidity Display Range: Screen lock & configuration password:

Copyright [W.L. Walker Co., Inc.]. All Rights Reserved

WDC Series Dual Condensate Conductivity Monitor. Instruction Manual

Operation 6035 ENGLISH PROG MENU

Loup Electronics Planter Monitor LPM II. User Guide

INSTRUCTION MANUAL CONTAINS: MOUNTING DIMENSION: For RVs,Caravans,and boats METER for duo-battery charging solar controller,

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8

2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.

Operation Guide CT101

Table of Contents Introduction Specifications Power supply: Operating temperature: Size: Display Data: Resolution: Ranges:

BITMAIN. S2 Server Manual

AirPatrol WiFi Version 2 Full Manual V4.2

Clipsal HomeMinder Home Automation System

ReefKeeper Elite v2. v2.0+ USER GUIDE (Draft)

IR Crop Temperature/ External Soil Temperature Meter PRODUCT MANUAL

HAND-HELD THERMOCOUPLE THERMOMETER SERVICE MANUAL. CATALOG NUMBERS , and , and PROPRIETARY

Operation Guide CT32 ENGLISH

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

BACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL

PRODUCT FAMILY: SOLO Controllers Number: AN-LC-009

SRS10 (SRS11/SRS13/SRS14) Series Programming Function Instruction Manual

24h TEMPERATURE MONITOR CONTINUOUS TEMPERATURE MONITOR USER INSTRUCTIONS. Model KD-2300 CE 0118

Mercury T Controller Installation & User Guide

INCOE I Series IC-15A Temperature Control Module Quick Start Manual

idevices Connected App Manual

AirPatrol WiFi Version 2 Full Manual. for ios V4.2

IN5132/IN5142/IN5134/IN5134a IN5144/IN5144a/IN5135/IN5145 User's Manual (detailed) Instant Stack Guide

CompX elock. Manual Programming Guide

User's Guide. Dual Input RTD Thermometer. Model Washington Street Melrose, MA Fax TestEquipmentDepot.

Installation, Start-up and Operating Instructions

idevices Connected App Manual

TC41-Thermocouple Thermometers User Manual

Series 8L Alarm Aux Setpoint Configuration

CONTENT. Check up. Brief. 1.Before use. 2.Operation. 3.Others

Dieter Wirth, Mess & Regeltechnik Neidlingen

Transcription:

Golden - Dog Manual 1

Table of Contents Displays P. 3 Buttons P.4 Menus P.5 P.8 Troubleshooting P.9 Restoring to default P.10 2

Displays There are two LCD displays and they are labeled PV / SV. PV is a read out and SV is your input. The LED display is located below the LCD displays. RUN: This green colored LED will blink very rapidly when manual mode and blink slowly when the fan is in auto mode. NOTE: In manual mode you will see - - - - on the SV display. Hi: This red colored LED is the high temperature alarm light. Lo: This red colored LED is the low temperature alarm light. 3

Buttons The controls are located below the LED display and they consist of four buttons: This button is used to activate your three menus. This button scrolls left with every click, it is used to easily enter large numbers without having to do it sequentially. This button will also set auto to manual mode. This is used to lower the current number on the SV display. This is used to raise the current number on the SV display. 4

Menus Menu #1 - activated by pressing. Menu #2 - activated by pressing and holding the button down. Menu #3 - activated by continuing to hold the button down while it is in Menu #2. 5

Menu #1 (Single Click): This will cycle you through the 4 stage temperature setting. Each button click will move you through the menu starting at SC1 and ending at AH4. SC1 SC2 SC3 SC4 RC1 RC2 RC3 RC4 AL1 AL2 AL3 AL4 AH1 AH2 AH3 AH4 Legend: SC= Desired pit temperature. RC= Timing at desired pit temperature. e.g. 0060 = 1 hour AL= Low temp alarm, to turn this off set it at a temperature that will never be reached; e.g. 0001. AH= High temp alarm, to turn this off set it at a temperature that will never be reached; e.g. 0600. 1-4= This number represents the stage. If you want only one temperature stage, simply set SC2 to 0000, it will now ignore the remaining stages. You can also do this for SC3 and SC4. 6

Menu #2 (Press and Hold): This will bring you to the second menu, a single click will cycle through the menu and pressing and holding the button will bring you out of the menu. F C (default SV value 0000 set to Celsius)= Changing the value to 0001 sets it to Fahrenheit. SL1 (default SV value 1111)= Internal parameter to define mode of alarm. For BBQ use, leave at default value. SL2 (default SV value 1011)= Internal parameter to define mode of alarm. For BBQ use, leave at default value. HdC (default SV value 0100)= Maximum Fan speed > This is represented in a percentage(0001-0100). e.g. If you have a 10 CFM fan and set it to 0050 = 10CFM * 50% = 5CFM will be the maximum speed the fan will spin. This is mainly used in respects to the size of your cooker, the bigger the cooker the more of the fan you want to utilize and vice versa for smaller cookers. 7

Menu #3 (Continuing to hold the button while in Menu #2): This will bring you to the third menu, a single click will cycle through the menu and pressing and holding the button will bring you out of the menu. P (default SV value 0030)= PID setting. Google PID controllers for a detailed explanation. I (default SV value 0240)= PID setting. Google PID controllers for a detailed explanation. D (default SV value 0060)= PID setting. Google PID controllers for a detailed explanation. To manually adjust these settings set I and D to 0000 while adjusting P to fine tune the responsiveness of the controller. The larger the value of P the less responsive it will be and the smaller the value the P the more responsive it will be. e.g. 0001 = very responsive, 9999 = less responsive, try any number in between until you find your ideal setting. AR (default SV value 0100)= use default, function not used. T (default SV value 0000)= use default, function not used. Pb (default SV value 0000)= used to calibrate the temperature probe change the value until the unit is calibrated. Ice water should read 0C/32F and boiling water should read 100C/212F. UdC (default SV value 0000)= Minimum fan speed, used to define the minimum fan speed. Use a higher value if you do not want your fan spinning at the lower speeds or leave at default. LCK (default SV value 0000)= use default, this locks the controllers internal parameters 8

Q: My PV display is showing - - - - Golden Dog Manual Troubleshooting A: This means you have either a loose or bad probe and will need to reconnect the probe wire or replace the probe. Q: My Hi/Lo is red LED is blinking A: This means you have exceeded your temp ranges set in Menu #1. Q: My PV display is blinking A: This means that the temp has exceeded readable temperatures. Q: My SV display is blinking - - : - - A: This signifies your TC timer set in Menu #1 has expired. Q: My temps get way too hot when I open my lid A: The Dog is a memory based PID controller, to counter act temp spikes when you need to open the lid simply switch the controller off and turn it back on after you have replaced the lid. Q: But I don t want to use all 4 temperature stages! A: Set SC2, SC3 or SC4 to 0000 to cancel the remaining stages. Q: My PV display is showing ERR A: Please restore to default settings. Please refer to page 10 for directions. 9

Restoring to default settings: 1. Turn off the power switch for 3 seconds. 2. Press and hold. 3. Turn the power switch on, it will now show 8888, 1111, 2222 and then 3333. 4. Now release. 10