Thermal Design and Management of Servers

Similar documents
Beat the Heat in Notebooks with Software

Product Press Release. Taipei, Taiwan November, 2007

Gigabyte Technology. 3D Rocket II Cooler PCU23-VE Media kit. Rev:1.0

ASUS X-Mars CPU Cooler

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Advanced Thermal Solution Dynamic Heat Conduction System (DHCS) Introduction

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

Extreme Weatherproof in Surveillance Cameras

Conduction Cooling for Stackable SBCs

TEMPERATURE CONTROL AND MOUNT SELECTION

Liebert DCW CATALOGUE

Dominick Lovicott Enterprise Thermal Engineering. One Dell Way One Dell Way Round Rock, Texas

Electronics Cooling Using Conduction Convection Radiation from Heat Sinks to Heat Pipes - CFD Consulting Services

Temperature Analysis of Intel Server by using CFD and Experimentation

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS

ENCLOSURE HEAT DISSIPATION

QSFP-DD: Enabling 15 Watt Cooling Solutions

Innovative Technologies Realizing Compact PRIMERGY TX120 Server

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server

Rear Door Heat Exchanger

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy

NREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions

HIGH DENSITY RACK COOLING CHOICES

The discussion of energy conservation of data center from the evaporative cooling technology of HPC

Total Modular Data Centre Solutions

Cooling of. Offering a safe & reliable way to cool semiconductor equipment & applications SOLUTIONS GUIDE

Efficiency of Data Center cooling

Gigabyte Technology. 3D Galaxy II LCS Cooler. Media kit GH-WIU02. Rev. 0.1

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Thermal Performance Analysis of Intel workstation Server using CFD

Liquid Cooling Package LCP Cooling Systems

IT Air Conditioning Units

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Tutorial to simulate a thermoelectric module with heatsink in ANSYS

OPENVPX COOLING SOLUTIONS. An Elma White Paper

Next Generation Cooling

Ben Zandi, Ph.D. TES International LLC

19 Rack-mount Rugged Fanless HPS+GPU

Best Engineering Practice to Extend the Free Air-Cooling Limit in Tablet Hand Held Devices AMD TFE 2011

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

BOARD LEVEL POWER SEMICONDUCTOR HEAT SINKS

BIOS PCB COVER ( ) ( )

E105 1/2-ATR Short Fan cooled VME Enclosure

19 Rack-mount Rugged Fanless HPS+GPU

Reliable Direct Liquid Cooling for the world's most demanding Data Centers.

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Server Thermal Considerations to enable High Temperature Ambient Data Center Operations

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

COOLING OF POWER ELECTRONICS

The Role of CFD in Real Life Designs

Liquid Cooling Package LCP Cooling Systems

LCS Value Proposition November 2014

FREEING HPC FROM THE DATACENTRE

Overcoming the Challenges of Server Virtualisation

Rack cooling solutions for high density racks management, from 10 to 75 kw

Thermal management. Thermal management

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

(12) Patent Application Publication (10) Pub. No.: US 2016/ A1

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

MasterAir Maker 8. Sales Kit

INSIDE THE PROTOTYPE BODENTYPE DATA CENTER: OPENSOURCE MONITORING OF OPENSOURCE HARDWARE

Multi-layer Architecture Synergy-Cooling Masterpiece

Thermal solutions for MMIC line amplifiers in CATV systems

Taking The Heat Off University of East Anglia Data Centre

THERMAL MANAGEMENT THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

FlexATX Thermal Design Suggestions. Version 1.1

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

Data centers control: challenges and opportunities

GP SERIES Packaged Chillers

Technology for Constructing Environmentally Friendly Data Centers and Fujitsu s Approach

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

Switch to Perfection

12 Reasons to and Use the CLP Family

Ultra Micro Cooling Device

Close-coupled cooling

JUNXY Series DC Load Banks

Increasing Energy Efficiency through Modular Infrastructure

Planning for Liquid Cooling Patrick McGinn Product Manager, Rack DCLC

High-performance, low-cost liquid micro-channel cooler

Cooling Solutions & Considerations for High Performance Computers

Google s Green Data Centers: Network POP Case Study

MPBS1 12V DC-DC Power Supply Rev B

INNOVATE DESIGN APPLY.

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

INNOVATE DESIGN APPLY.

Power and Cooling Innovations in Dell PowerEdge Servers

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

Power On. In the Negative Space.

Nokia open edge server

BGA THERMAL SOLUTIONS MATRIX

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

Application of TileFlow to Improve Cooling in a Data Center

Transcription:

White Paper Thermal Design and Management of Servers

Thermal Design and Management of Servers P.1 Overview With the exponential growth of knowledge development, data needs to be stored, processed and secured so users can access the data quickly. Servers engage in a major role in this type of dataintensive business applications. The progressions in hardware, software and miniaturization technologies, along with the information development, has led to a huge increase in servers power densities and computing power. By developing thermal management in servers to remove the heat generated by the devices, it will improve the reliability and enhancement performance. Green Data Centers A data center is complied of computer servers usually controlled and maintained by an operation to accomplish server needs much greater than the capability of one machine. These centers run extremely scaled software applications with million of users. The demand for bigger and better data centers increase as they become the nerve centers of business and society. There is a rising need to generate the most computing power per square foot at the lowest possible cost in energy and resources, all of which is bringing new level of attention and challenges. A green data center is essentially a repository for the storage, management, and dissemination of data. In the center, the mechanical, lighting, electrical and computer systems were developed to optimize energy efficiency and environmental impact. The operational scope of a green data center design for the IT industry must minimize the carbon footprints of buildings and use alternative energy technologies. A green data center focuses on two primary objectives, energy conservation and environmental safety. This is achieved through optimizing the performance of cooling systems using real-time sensing technology. To resolve this issue, green data centers perform sensor-based optimal cooling. Thermal Challenges in Servers The growth in power densities, performance, and reliability constraints will generate major obstacles for the thermal management of servers. These thermal challenges will change with different products and requirements. Such challenges faced in the servers consist of very high

Thermal Design and Management of Servers P.2 power dissipation, high ambient temperature, stringent thermal requirements, harsh environment, meeting strict standards and compliances, miniaturization, product design cycle time reduction, minimizing the thermal cost, and feasibility solution using available resources. The electronics cooling industry has put into consideration these challenges and has come up with path breaking innovative solutions time after time. Innovative Cooling Solutions Due to thermal challenges, it has led to solutions in thermal management. The latest technologies in the thermal management arena function in and around the basic heat transfer modes. The development has reached a point where the technologies overlap the fundamental functional industrial domains. The development of technologies is moving from single-phase heat transfer to multi-phase heat transfer, which has led to the design of advanced cooling solutions. Different technology types require different cooling techniques. Conduction Cooling Conduction: An important cooling technique where more heat will be transferred to surrounding ambient through the conduction heat transfer. Advanced Cooling Technologies Refrigerant Cooling: Hybrid Cooling: Cold Plate Technologies: Smart Cooling Technologies Spot Cooling: Heat Pipes/ Heat Super Conductors: Used when sub-cooled temperatures are required in a system. More than one coolant will be used. Cooling will achieved through more than two different modes of heat transfer. High conductive material with the flow passes will be in contact with the power dissipated components. Low melting point liquid will flow trough the passes and remove heat from the chip. During this process, a cold fluid will be blown across the spots wherever hot spots are present, and cooling will be attained. This can be achieved directly or indirectly through a fan. The hollow tubes are filled with a low melting point liquid, with tube wall and liquid separated by a wick. The highly conductive material will help disburse the heat with low resistance. It is a very effective, noise-free technique which will remove heat from the processor chips.

Thermal Design and Management of Servers P.3 Compact Heat Exchangers: With the miniaturization in the place, heat will be removed from the system to ambient through compact heat exchangers. etecs (Embedded TECs): With multi-core processors where some of the cores may be very hot and the temperature must be brought down to allowable limit, TECs will be inscribed at a certain portion of the die, and these will take care of the die temperature. Thermal Management of High End Server A high end server comprises of as many as 13 sublevel nodes packed in a compact chassis in two rows. Each sublevel node consists of six IO cards, 32 DIMM cards, four multi-core processors, one voltage transformation module and two DCA channels. The total power dissipation of each node is 2.4kW and the total power dissipation of full high end server is 32.1kW. Providing a thermally feasible optimal solution to this high end server is very difficult and challenging. Thermal Challenges Multi-Core Processors Cooling Less space available and preheated air will flow across the processors, making the design more challenging Advanced cooling technologies is needed from the industry to cool these next generation processors Total power dissipation = 920W

Thermal Design and Management of Servers P.4 DIMMs Cooling Less flow rate availability Space constraint between DIMMs Total power dissipation = 736W Voltage Transformation Module (VTM) Channel Cooling Has one of the critical flow path designs in the server VTMs are placed in a narrow flow channel through which fluid enters the modules this is one of the geometric constraints for the thermal design Second constraint is available flow rate to cool the modules Total power dissipation = 370W System Pressure Drop Optimization Since it is a very high power dissipating system, there is a need to optimize the system in such a way that maximizes the heat transfer and minimizes the pressure drop. Innovative Thermal Solutions Multi-Core Processing Cooling Designed and optimized a customized heat sink fulfilling the thermal requirements. Heat sink has been designed so that it minimizes the weight and decrease the cost. Base and center fins of the heat sink were designed as copper, and extreme fins were made up of aluminum. Heat pipes were used to connect through the aluminum fins and the base of the heat sink. This combination of different heat sink materials and heat pipes is providing allowable temperature limit for processor This innovation design added value to the customer DIMMs Cooling Nova chip which controls the DRAMs cooled with custom made optimized heat sink Nova chip heat sink was designed with a constraint on the height of the heat sink (distance between any two respective DIMMs was less) and the less available flow rate across the DIMMs The innovative design of Nova chip heat sinks across all DIMMs made thermal cooling possible for high dissipating DIMMs

Thermal Design and Management of Servers P.5 Voltage Transformation Module Channel Cooling Two different innovative concepts were proposed for VTM channel cooling One is a generic solution with innovative optimized individual heat sinks for each VTM within a narrow flow channel. These new heat sinks were fully custom made. The other is a novel concept in which we achieved a thermal solution with the available flow rate within a narrow flow channel. This is achieved fully wit conduction cooling and partly through convection cooling Optimal pressure drop is achieved to maximize the flow rate through the channel System Pressure Drop Optimization From the start of the thermal solution, emphasis has been on the pressure drop for each and every module across the system Pressure drop optimization helped to reduce the acoustic related problems with fully utilizing the available flow rate across the system Thermal Management of Rack Mount Server A typical rack mount server consists of a power supply unit, hard disk, IO board, motherboard, network switching board, and a power distribution board. It contains 1U, 2U, 3U, and 4U rack.

Thermal Design and Management of Servers P.6 Thermal Challenges High ambient temperature Cooling HDDs Fan locations were fixed, most of the flow is taking the path of least resistance Providing a solution at high altitude conditions Meeting the strict compliances and standards of the product Smart Cooling Solutions Flow deflectors/ducts were used to utilize the available flow across the unit Four dedicated flow channel were designed to control the flow behavior inside the system. o HDD air flow channel HDDs were cooled with a flow duct, which will direct the flow from the fan to HDD without any preheat in the air o Network switch board and PDB flow channel Custom made heat sinks were designed to cool the components on these two boards o CPU flow channel Processor was cooled with a custom made heat sink with a heat pipe and hear sink advanced cooling option o IO Board flow channel Conclusion As servers are very important in data centers, thermal management of servers in data centers and green data centers was also highlighted with descriptions of the innovative cooling technologies which have evolved in the industry. Present thermal challenges faced by servers and the innovative solutions which emerged from the industry were discussed.