RC701/RC702-FE series Ethernet over SDH devices User Manual

Similar documents
RC702-FX Ethernet over SDH User Manual

OPCOM STM-1 High Capacity Terminal Multiplexer USER MANUAL. Raisecom Technology Co., Ltd (4/2005)

RC315/316-FE (Rev. A) 10/100M Auto-negotiation Copper-to-Fiber Media Converter. User Manual. Raisecom Technology Co., Ltd.

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd.

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

User Manual. RC511/RC512 Series SNMP Manageable, Bandwidth Control, 10/100 Mbps Auto-Sensing Ethernet Copper to Fiber Media Converter

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

RC414 Universal Optical Converter/Repeater User Manual

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

RCMS Modular Optical Multiplexer Manual

Gigabit Ethernet Media Converter. User Manual

E1/10&100Base-T Bridge (VLAN)

FB-10/100MMC Series Managed/Unmanaged. 10/100Mbps Fiber Media Converter User Manual

Connector and Cable Specifications

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

TRP-C41 User s Manual

Installation Guide. 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC. -1-iIiNC-200FT/FC P/N:

4 E1-4 x 10/100 Ethernet converter with VLAN

GYM Bilgi Teknolojileri

RC832-30(-BL) User Manual

F9-480 Series 4/8/16E1 Plus Ethernet Multi-service Multiplexer User Manual

ETHERNET FIBER OPTIC CONVERTERS

Datasheet RCMS2801 FE Series Multi-service PDH Optical Multiplexer

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

D9408 Advanced ATM Adapter

Datasheet RCMS2802 FE Series Multiservice PDH Optical Multiplexer

Cable Pinouts. SRP I/O Module

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

RC E User Manual

T3 Interface Converters

Atrie WireSpan 620. User's Manual

RC801-60B-FV35, RC803-60B-FV35, RC805-60B-FV35 Series Standalone V.35+E1 Dual Interface Fiber Optic Modem. User Manual REV.N

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

F Series 10/100Mbps to 4E1 Converter F User Manual (Version: 3.2)

16E1 + 1Ethernet Fiber Optical Multiplexer

16 x E1 G x Ethernet optical multiplexer

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

Switched Uplink Modules

Read me first User's Manual Release Note

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH. Product Brochure. Copyright: Valiant Communications Limited U.K. INDIA U.S.A.

Appendix A Cable Pinouts

Industrial Ethernet Optical Fiber Link Adapter FIB-IE-S User Manual

V C ALIANT OMMUNICATIONS. Product Brochure & Data Sheet

RC905-EE1. Ethernet to E1 Interface Converter (REV.B) User Manual

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS. KC-300DM Series. Installation Guide

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

F /100Mbps Ethernet to 8E1 Converter. Standalone/Module/Chassis User Manual

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide

The specifications for the Cisco 7304 router are listed in Table A-1.

Metrodata WAN-in-a-CAN WC-155 LAN Extender Installation Guide

High performance access device

Overview. Port Adapter Overview CHAPTER

RS-232 Connector Pin Assignments

Optimux-4T1 Four-Channel T1 Multiplexer

Fast Ethernet Converter. User Guide MICROSENS

IES615-2D Series. Industrial Ethernet Switch. User Manual. Summarize. Panel layout. Packing list. Features. Shenzhen 3onedata Technology Co., Ltd.

Preface. Managed Media Converter Chassis System

RION ORION TELECOM NETWORKS INC. TELECOM NETWORKS. Optical Multiplexer Product Brochure. Orion Telecom Networks Inc.,

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS

Loop-O 9300 Fiber Optical Mux

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

IES308-2F. Introduction: Packing List: Features: 8-port Unmanaged Industrial Ethernet Switch Hardware Installation Guide

Preface. Media Converter

Compliant with ITU-T G.8262 (SyncE) for frequency synchronization; Compliant with IEEE (PTP) for phase and frequency synchronization

10/100/1000Base-T to 1000Base-FX Fiber Optic Media Converter OP-ECxx3xxx-xx

100Base-FX to 10/100Base-TX. PoE. Media Converter. FCU-1802Px. User s Manual

FE1&10/100BASE-T Bridge

Manual. Preface. XSNet 3100MC

FSW-1609TFX FSW-2409TFX

Media Conversion. Media Conversion. Extend Network Distance via Fiber Optic. > OAM Remotely Managed Media Converter...

FE1/10&100Base-T Bridge

KIS-MC M Media Converter

10/100Base-TX to 100Base-FX Media Converter

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

IES1024 series. Industrial Ethernet switch. User manual

V C ALIANT OMMUNICATIONS. VCL-Ethernet over SDH (Ethernet over STM-1) Product Brochure. Copyright: Valiant Communications Limited U.K.

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

CWGE2SFP. Commercial Grade 10/100/1000BASE-T(X) to 1000BASE-FX Gigabit Ethernet Media Converter INSTALLATION AND OPERATION MANUAL

TCF-142-RM Series Hardware Installation Guide

RC954 Series Modular Inverse Multiplexer User Manual

FOM-FXO32 / FOM-FXS32 32 Voices (FXS/FXO) POTS Fiber Multiplexer

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

VCL-TP, Teleprotection Equipment

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

RC552-FE (A) User Manual

PTC-101 Quick Installation Guide

Connector and Cable Specifications

Overview. Features CHAPTER

8 Chanel HD SDI Over Fiber. Transmitter and Reciever Extender. User Manual L-8SDI-FE-HD-TX/RX

Copyright PLANET Technology Corp Contents subject to revision without prior notice.

Datasheet. RC3000E Multi Service Access Node. Chassis. Uplink Cards. Specification. Downlink Cards. Raisecom Technology Co., Ltd.

PS3108C. 8-Port Web Smart GbE PoE+ Switch QUICK INSTALLATION GUIDE

VDTU2-B110 VDSL2 LAN Extender

Transcription:

RC701/RC702-FE series Ethernet over SDH devices User Manual Raisecom Technology Co., Ltd

1. Cautions Warning: Only trained and qualified personnel should be allowed to install, replace or service this equipment. RC702 is integrated equipment. Move carefully and do not disassemble or mend it without the guidance of Raisecom technical engineer with the anti-static procedures. The equipment must be grounded. Do not disassemble the equipment by yourself. It may cause unrecoverable damage. Raisecom will not be responsible for the damage by this. 1

Contents 1. Cautions...1 2. Overview...3 2.1. Introduction...3 2.2. Main features...3 2.3. Part number explanation:...3 3. Parameters...5 3.1. Optical interface module...5 3.2. Electric interface module...5 3.3. Power supply...5 3.4. Dimensions...5 3.5. Basic components...6 3.6. Extended card interface properties...6 3.7. Properties of Ethernet interface...6 3.8. Properties of CONSOLE interface RC702-FE only...6 3.9. Properties of SNMP network management interface RC702-FE only...6 3.10. Power supply conditions...7 3.11. Operating environment:... 4. How to use...8 4.1. Front view and explanation...8 4.1.1. Front view and explanation of RC701-FE...8 4.1.2. Front view and explanation of RC702 FE...8 4.2. Explanation of front view indicators...9 4.3. Rear view and explanation...10 5. Applications...12 6. Installation...13 6.1. Preparation...13 6.2. Installation...13 6.2.1. Prepare cables...13 6.2.2. Install extension card...14 6.2.3. Connect 100M Ethernet interface...14 6.2.4. Connect 155M SDH interface...14 6.2.5. Connect CONSOLE interface (RC702-FE only...14 6.2.6. Connect network management interface RC702-FE only...15 6.2.7. Power on...15 7. Q&A...16 8. Appendix How to make CONSOLE cable...17 8.1. Appendix 1 cable of CONSOLE interface...17 2

2. Overview 2.1. Introduction RC702-FE is an Ethernet over SDH device developed by Raisecom Technology Co., Ltd, it provides a 155M SDH interface (optical or electronic) and a 100M Ethernet interface (electronic), and encapsulates Ethernet data packets to SDH/SONET payload, so remote Ethernets can be connected through SDH transmission network at a high speed. This device is available in all the operating networks such as: China Telecom, China Unicom, China Mobile, China Netcom and China Broadcast & Television, meanwhile it accords with X.85/X.86 of ITU-T, YD/T 1179-2002 of Ministry of Information Industry and related standards of SDH/SONET. RC702-FE provides network management and it is very convenient to manage. 2.2. Main features Provide a 100M Ethernet electronic interface and an extended slot in which a 155M SDH optical or electronic interface module can be put. In SDH/SONET optical interface mode, the longest transmission distance is 120km. RC702-FE provides Console interface and SNMP network management interface. RC702-FE provides SNMP network management function, and accords with the standard specifications of SDH/SONET network management. Provide local and remote alarm indicators so it can be installed and maintained conveniently. RC702 does not specify the size of Ethernet frame, and the transmission for Ethernet protocols is transparent. Inside power supply, both 220V AC and -48V DC are available, so it supports two power supplies redundancy. Device power : 15W 2.3. Part number explanation: Model RC701-FE Explanation Transmitting 100M Ethernet data on SDH network without network management. 3

RC702-FE Transmitting 100M Ethernet data on SDH network with network management. 4

3. Parameters 3.1. Optical interface module Module type SC-OP /M SC-OP /S1 SC-OP /S2 SC-OP /S3 Conn ector SC/ Multimode SC/ Single -mode SC/ Single -mode SC/ Single -mode line coding wavel ength nm TX power db Rx sensiti vity db Estimated transmission distance Km NRZ 1310-18 -14 <-29 0 2 3 NRZ 1310-15 -8 <-34 0 25 0.5 NRZ 1310-5 0 <-34 10 60 0.5 NRZ 1550/ DFB Optical loss db/km -5 0 <-36 15 120 0.25 3.2. Electric interface module Module type: SC-EP/CC3 Port type: 75Ω Coaxial cable port Line coding: CMI Peak-to-peak value: Comply with ITU-T G.703 3.3. Power supply Model RC700-PWR-AC RC700-PWR-DC Explanation 220V AC -48V DC 3.4. Dimensions This device adopts the international standard 19 inches chassis, delicate appearance and convenience installation. RC701/702-FE: 440mm W *43.6mm* H *200mm D 5

3.5. Basic components Extended card interface: 155.52Mbps SDH/SONET optical or electronic interface Ethernet interface: 100Mbps electronic interface Power supply modules: 220V AC or 48V DC Management interface: CONSOLE interface, Ethernet interface and SNMP network management interface (only for RC702-FE). 3.6. Extended card interface properties SDH optical interface:155.52mbps, line coding : NRZ, more information of available optical interface type is in the table of Explanation of extended card Type of optical interface: SC port SDH electronic interface: line coding CMI, signal peak-to-peak value 0.9 1.1V, and accords with ITU-T G.703 Electronic interface type: 75Ω coaxial cable port Support the ITU-T G series suggestions. 3.7. Properties of Ethernet interface Interface: electronics port, 100Mbps, full-duplex Interface type: RJ-45 Support IEEE802.3 standards 3.8. Properties of CONSOLE interface RC702-FE only Interface type: RJ-45 Comply with RS232 Rate 9600bps 3.9. Properties of SNMP network management interface RC702-FE only Interface type: RJ-45 Support IEEE802.3 standards 10/100M auto negotiation 6

3.10. Power supply conditions Voltage: -48V DC, range of tolerance 36V 72V 220V AC, range of tolerance 180V 260V Device power: less than 15W 3.11. Ambience Temperature:0 +45 Humidity: 90% (35 ) 7

4. How to use 4.1. Front view and explanation 4.1.1. Front view and explanation of RC701-FE Electronic extended card is in figure 4-1, and optical extended card is in figure 4-2 4.1.2. Front view and explanation of RC702 FE Electronic extended card is in figure 4-3, and optical extended card is in figure 4-4 8

4.2. Explanation of front view indicators Type Description Extended card interface (SDH optical or electronic interface) PWR Power supply indicator light, system is powered on when light is on and not powered on when off. ALM Alarm indicator light, indicates alarms of device LOF Alarm of receiving frame not synchronously when light is on LOS Alarm of receive-signal loss when light is on OFF Switch, and default status is OFF. ON (numbers sequence is from left to right) 1234 First number OFF: Ethernet interface is in auto negotiation status; ON: Ethernet interface is in 100M full-duplex status Second RESERVED(must be OFF) 9

number Third RESERVED(must be OFF) number Fourth RESERVED(must be OFF) number Ethernet interface Indictor of receiving and transmitting status, data is been ACT transmitting when light is on and no data transmitting when off. Indicator of Ethernet connection status, connect successfully when LNK light is on and unsuccessfully when off. Indicator of Ethernet interface rate, rate of Ethernet interface is 100M 100M when light is on and 10M when light is off. (note 1) Indicator of full-duplex, Ethernet interface is in full-duplex mode FDX when light is on and in half-duplex mode when light is flicking. (note1) SNMP network management interface ACT Indictor of receiving and transmitting status, data is been transmitting when light is on and no data transmitting when off. LNK Indicator of network management interface connection status, connect successfully when light is on and unsuccessfully when off. 100M Indicator of Ethernet network management interface rate, rate of Ethernet network management interface is 100M when light is on and 10M when light is off. FDX Indicator of full-duplex, Ethernet network management interface is in full-duplex mode when light is on and in half-duplex mode when light is flicking PWR Power supply indicator light, system is powered on when light is on and not powered on when off. SYS System indicator, flicking means CPU works regularly. Power supply card 1/ Power supply card 2 Power supply indicator light, power on when light is on and not PWR power on when off Note 1: This device only supports 100M full-duplex mode, and it will not work normally if Ethernet interface can not negotiate to 100M full-duplex mode. 4.3. Rear view and explanation When use AC power supply, there is 220V standard three-phase plug, as figure 2-5: 10

When use DC power supply, there is -48V power supply plug. Note: there three connections of DC power supply: -48V, ground, 0V, and they connect to -48 power supply cable, protection ground -48V G 0V and 0V power supply cable. Remember that protection ground connection is very important for safe use of the device. 11

5. Applications RC702/701-FE use SDH transmission network for long distance transmission of Ethernet data. And there must be a VC4 channel in SDH/SONET before using this device. Both of ends of this channel have a RC701/702-FE device to connect Ethernet and SDH. Typical topology is as follows: 12

6. Installation 6.1. Preparation First check the type and amount of the device with packing list, and the appearance. There must be drying process if the device is affected with damp. To make sure the device will work normally, pleas follow the steps: Read this guide carefully Prepare optical fiber or 75Ω coaxial cable Fix and install access device. Connect fiber or cable. Configure EOS device RC702-FE only, more information is available in configuration guide. Work normally. 6.2. Installation 6.2.1. Prepare cables The required cables are in table 6-1: Table 6-1 interface cable specifications of RC701/702-FE EOS Interface Specification 100Mbps Ethernet interface and SNMP UTP of 100Base-T, the longest distance is 100m, network management interface CONSOLE cable 155Mbps SDH optical interface 155Mbps SDH electronic interface Power supply interface Available in appendix Single mode or multi mode optical fiber of SC depends on users. 75Ω coaxial cable, for short distance connection. Use SYV-75-2-2 communication cable. AC mode, 220V/10A power supply cable DC mode, -48V/10A power supply cable 13

6.2.2. Install extension card Extension cards of same type devices can be exchanged, for example: extend cards of two RC701-EF can be changed. You must use jumper to exchange extended cards of different type devices. Crossover cable differences of extension cards between RC701-FE and RC702-FE, table 6-2 and 6-3 Table 6-2 Jumper settings of electronic extended card of RC701/702-FE Type RC701-FE RC702-FE jumper JP1 Connect with a short N/A JP2 N/A Connect with a short JP3 N/A Connect pin 2 and 3 with a short Table 6-3 Jumper settings of optical extension card of RC701/702-FE type RC701-FE RC702-FE jumper JP1 Connect with a short N/A JP2 Connect pin 1 and 2 Connect pin 2 and 3 with a short with a short JP3 N/A Connect pin 2 and 3 with a short Note: this is the default settings. 6.2.3. Connect 100M Ethernet interface One end of Ethernet cable connects to router or switch, and the other end connects to Ethernet interface of EOS device. Usually, Ethernet interface is in 100M full-duplex mode. 6.2.4. Connect 155M SDH interface Connect one end of SDH optical fiber to the SDH interface on EOS device. Connect the other end of SDH optical fiber to STM-1 interface of SDH device. Under normal condition, indicator lights of LOS and LOF are off. 6.2.5. Connect CONSOLE interface (RC702-FE only Connect the RJ45 connector of CONSOLE cable to CONSOLE interface 14

on front panel of EOS device. Connect the DB9 connector to PC serial interface. Run Hyper terminal program, and configure the baud rate as 9600. Configure RC702-FE, more information is available in configuration guide. 6.2.6. Connect network management interface RC702-FE only Connect SNMP network management interface to related network. 6.2.7. Power on When connect power supply cable, first connect the cable to POWER plug on rear panel of EOS device, and than connect to power supply. If you use the -48 DC power supply, first connect protection ground, then -48V connection to low electron cable and finally 0V to high electron. Make sure of firm installation and no short-cut, turn on power supply. If you use 220V AC power supply, the cable described in appendix is available. After being powered on, the power supply indicator lights of power supply card, device and extended card work normally. 15

7. Q&A If you have problems during the installation or application, please try to solve them through the following suggestions. And if it does not work, please contact the sellers to get technical supports. PWR light of power supply card off Check the power supply cable first, if power supplied normally there must be error of power supply card. There is LOS or LOF alarm of SDH optical interface or electronic interface. That is to say, there is receiving signal loss or frames receiving not synchronously of SDH optical or electronic interface. First, check whether the fiber or cable is connected correctly; secondly, self-loop the fiber (perhaps optical loss is needed) or cable, if there are still alarms, then there is something wrong with device. Indicator light of Ethernet interface or SNMP network management interface is off. First, check whether the cable works normal or not; then, check whether the devices connect to Ethernet interface or SNMP network management interface works normal or not. It is recommended that use rollover cables to connect switch or hub and use crossover cables t o connect router or NIC. Line is disconnecting. Check whether Ethernet interface is in 100M full-duplex, and it must be in that mode, otherwise it will not work. 16

8. Appendix How to make CONSOLE cable 8.1. Appendix 1 cable of CONSOLE interface Signaling and Pinouts of CONSOLE of RJ45 plug: Pin number of RJ45 Signal Correspond PC serial port pin number 1 NC - 2 DSR# 6 3 RxD 3 4 GND 5 5 GND 5 6 TxD 2 7 DTR# 4 8 NC - 17

@2005 Raisecom Technology Co., Ltd. All trademarks are the property of their respective owners. Technical information may be subject to change without prior notification. 18