JUN 2016 Rev B

Similar documents
Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

E. Numbering and Labeling Pathway components. In general, pathway components are not labeled.

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

April 2017 Rev 1

M204SMB Surface Mount Box Instructions

SUBCON 15 HD (High-density) D-Subminiature Connectors

LANmark Snap-In Toolless connector. screened, with rear cover CAT7 GG45 INSTALLATION GUIDE

Installing a Power over Ethernet injector

ipod Classic Headphone Jack & Hold Switch Replacement

MacBook Pro 15" Core 2 Duo Models A1226 and A1260 SSD Dual Drive Installation

E1135C PDU and Pod Upgrade Procedure

Rack Installation Instructions

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

Cat.8 Shielded Field Termination Plug Description

Wall Mounted Building Entrance Enclosure Instructions

Service Manual (LS40, LS50) LG Electronics

CDRPan. Installation. Instructions for Siemens OP-10 FOR PANORAMIC SYSTEMS

RCC45 ➁ Overview / /

Closet Connector Housings (CCH)

Rack Installation Instructions

HD Flex Zero RU Cassette Holder and Bracket

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

SYSTIMAX 360 PATCHMAX Modular Panel Instructions

TDM To MiniMech conversion ProceDure

MacBook Core 2 Duo Display Replacement

CDRPanP. Installation. Instructions for Instrumentarium OP-100 FOR PANORAMIC SYSTEMS. Schick Technologies, Inc. Avenue

Solarlok PV BAR Junction Box Assemblies

The University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS

Installation Instructions

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

Megatouch FORCE Monitor Chassis Board Replacement

7403 K321. Display Wall Mount. Kit Instructions. Issue A

CDRPan. Installation. Instructions for Siemens / Sirona Orthophos 3 FOR PANORAMIC SYSTEMS

Encore XT Manual Gun Upgrade Kit

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

CDRPan. Installation. Instructions for Planmeca / PM 2002 CC / EC FOR PANORAMIC SYSTEMS

3M Indoor Protected Building Entrance Terminal 4788V-QCS Series

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

CDRPan FOR PANORAMIC SYSTEMS

HP ProLiant MicroServer

MacBook Core 2 Duo Clutch Cover

To connect the AC adapter:

TravelMate 6493 Series Disassembly Instruction

Microscope with original illuminator. Microscope with Nanodyne replacement illuminator.

Cable Routing Procedures for Dell PowerEdge R630 Systems

3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)

IBM. Rack Installation Instructions

Rack Mount Cabinet with Fiber Mgmt System, accepts up to 3 Adapter Plates. Rack Mount Cabinet with Fiber Mgmt System, accepts up to 6 Adapter Plates

Assembly Instructions for #5630 Medication PalWOW

Modular plugs, accessories and tooling

MacBook Pro 15" Core 2 Duo Models A1226 and A1260 SSD Installation

4888 and 4988 Outdoor Protected Entrance Terminals

SYSTIMAX imvision impower Power Extender Installation

3M Indoor Protected Building Entrance Terminal 4588V-QCS Series

SYSTIMAX 360 ipatch 96F LC Upgrade Kit

Single cable kit for the FCB1010

2 PIECE BOARD-TO-BOARD

Print Mechanism Maintenance Kit

AMP-TWIST* 6S Series SL Jack

Dell Wyse Client VESA Mounting Bracket for Dell P Series Monitor Installation Instructions

ww.battery-adapter.com

Description of parts Panel mounting Insert mounting without/with Carrier element Plastic housings

Schick Technologies Schick Technologies, Inc th Ave., Long Island City, NY (718) Fax: (718)

FP 00C GS0 FP 00C HS0 FP 00C TS0 Crimpless Connector for Plastic Optical Fiber Data Sheet

ipod Classic Click Wheel Replacement Written By: irobot ifixit CC BY-NC-SA Page 1 of 25

Written By: senordingdong

DXE Technical Note: Importance of Correct Termination of Shielded Cat5 Networking Cables. By Scott MacDonald, KD8BDX. Parts list:

Removing and Replacing Parts

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Cat.8 Shielded Keystone Jack Description

ExpressCard Instant Issuance Card Personalization System Ethernet Jack Replacement Procedure. September 22, 2014

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Closet Connector Housings (CCH)

Control Box Setup - PRSalpha

QUICK REFERENCE. Using the Battery

Dell Inspiron N5110 Service Manual

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

Replacement Instructions

Removal and Installation 8

AMP- LATCH* Universal

WINSTA. Full Line Catalog 2008/2009

Plasma Panel Replacement Guide DU-42PX12X

ODU AMC HIGH-DENSITY RECEPTACLE STYLE 6 ASSEMBLY INSTRUCTION

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

Rack Mount Interconnect Center (RIC3)

CLIPLINE complete. The modular terminal block system for all applications

Written By: Andrew Bookholt

Hardware Installation. In this chapter... Custom Labels EMI Noise Filter Installation Mounting DIN Clip Mounting Connections and Wiring

Field Service Guide Supplement for the NS 7000/030

Fibre Enlosures and Splicing

INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS)

MacBook Pro 15" Core 2 Duo Model A1211 Speakers Replacement

3: Handles. 3.1 Fluted Handles C 3_ Rigid-Mounted Unit Handles C 3_ Ejector Handles acc. to IEC C 3_4

Nabi Big Tab HD24 Speakers Replacement

MPS-Lite. A range of Blank and Connectorized panels in 3 standard widths to fit a 2RU / 3.50 vertical space, plus Adapters to accommodate them.

Datasheet. Fiber Optic Modular Patch Panel Features

Test Procedure for I8, I9 Probe Wiring Verification

Installing MacBook Pro 15" Unibody Mid 2009 Dual Hard Drive

STANDARD FOR ELECTRICAL CONTACTS, RETENTION CRITERIA

Transcription:

Application Specification 4-907 0 JUN 06 Rev B Sigma-Link Quick-Fit Cable Assembly. INTRODUCTION This specification describes the assembly procedure for Sigma-Link Quick-Fit pre-terminated cable bundle. Read these instructions thoroughly before starting installation.. DESCRIPTION Sigma-Link Quick-Fit Cable Assemblies are designed to be installed into Universal Connectivity Panel (UCP), part numbers -67590- or -67594-0, according to Instruction Sheet 4-7007 (UCP Panel). The patch panels are designed to be mounted onto a standard 9-inch Electronics Industries Alliance (EIA) rack or equipment cabinet.. REFERENCE DOCUMENTS DESCRIPTION CommScope drawings are available from the CommScope network. The information contained in customer and product drawings takes priority if there is any conflict with this specification or with any other technical documentation supplied by CommScope. Instr. sheet (UCP Panel) Packaging spec. (specific.) Packaging spec. (general for labelling) Instr. Sheet (Jack/Plug) Process spec. QC doc. 4-7007 07-70 07-9008 Refer to section 4. 8-904 / 8-906 (*) 08-7000 4. ASSEMBLY INSTRUCTION 4.. Termination Guidelines (Depending on the connector to be used) System Performance Product PN Instruction Sheet Termination tool STP Class FA-PL Jack 747-4-90 7550- STP Class EA-PL Jack 776-4-906 7550- UTP Class EA-PL Jack 9476-408-0470 7550- UTP Class E-PL Jack 9748-408-8858 7550- Tool view (for ref. only) Scale Foil cutter Cable strip hole STP(*) Class EA-PL Mod. Plug 499598- / Boot 994-8-907 Sentinel Hand tool ref. 90009 N/A Cable assembly lengths according to drawing PN 674; 0-PN- to 9-PN-9 meaning from to 99 meters. (*) Specifically for Consolidation Points. 05 CommScope, Inc. All rights reserved of 5

4.. Product Versions (Depending on configuration type) Configuration type / System Housing with POF Jack Open end Plug (*) STP - Class FA-PL X X X -- STP - Class EA-PL X X X X UTP - Class EA-PL X X X -- UTP - Class E-PL X X X -- 4.. Assembly Instruction (Pictures shown are for reference only) Connectors have been terminated according to paragraph 4.. Perform 00% Fluke testing for each single element before assembly jacks into metal frame (According to process spec.- section - ) 4 Assembly Jacks into metal frame by means of pivoting the jack while pushing it toward the bottom to allow the top latch to enter into the top rib of the metal frame 5 ( Click is the conformity sign) This is the sub-assy metal frame. Add number ID labels for each individual cable. Refer to relevant product drawing. Strain relief must clamp on braid and cable jacket. 6 (The metal mesh should be covered by the number ID labels). - POF preparation- Strip the Plastic jacket of the Optical Fiber Apply LOCTITE instant adhesive to one of the substrates to be bonded. Insert the POF through hole and hold firmly by hand for about 0 s. until fixture. (table continued) Rev B of 5

7 8 9 Handling strength is achieved within a few minutes. 0 Allow up to 4 h. for full bond strength to develop. Use in well ventilated areas. Avoid use of naked flames or other sources of ignition. The 4 bottom tabs of the metal frame has to fit into 4 slots of the holder (this will be the rotation Cut POF with a hot knife Pre-insert the sub-assy. metal frame (as shown in fig.) into the holder. 4 edge) Once pre-inserted, pivot the subassy metal frame while pushing it toward the top surface of the holder 5 assembly the grounding spring clip into the Front Cover (Repeat this process - depending on the configuration type - on both ends of the cable assembly. Refer to paragraph 4.). to allow the metal frame subassy. profile to enter into the holder slots. ( Click is the conformity sign). 6 7 Once cassettes are already available is time to 8 Insert the label, label cover and port ID label into Front Cover slots. by means of sliding the spring clip into the right slot on Front Cover (back side/bottom area). Ensure that spring is right placed & oriented (table continued) Rev B of 5

9 0 When POF is used (if any), perform lighting test check (00%) by using the light identifier device (or other method approved by Engineering) Insert and press in the cassette into the Front Cover. Once the cassette in completely inserted into the Front Cover, then two side latches should remain fixed. ( Click is the conformity sign). 4 Switch on the light and check that on other end cassette light is viewable Cables shall be bundled using approved taping method. (view shown as reference only) Cable bundle is finished and ready to be packed. (Black tape for reference only). (Refer to packaging specs. shown on section.) 4.4. Disassembly Instruction: Cassette (Cassette from Front Cover) Detail of Side tabs to allow unlocking process (disassembly cassette from Front Cover ) Press laterally out the Side tabs with the fingers (as shown) at same time that hand is pushing back the cable bundle to allow unlocking cassette from Front Cover. Cassette is completely out from Front Cover. Rev B 4 of 5

4.5. Disassembly Instruction: Jack (Individual Jack from Cassette) Cassette is populated with Jacks. In order to remove one specific jack from cassette, you can use the help of related top openings to 4 insert the screwdriver through the selected opening and press the jack latch at same time that rotates it then, jack is unlocked from metal frame by pushing back the cable. The single cable assembly is completely out. 5. INSTALLATION PROCEDURE For installation of Sigma-Link Quick-Fit Cable Assemblies into Universal connectivity Panel (UCP), please refer to Instruction Sheet 4-7007 (UCP Panel). 6. REVISION SUMMARY This paragraph is reserved for a revision summary of changes and additions made to this specification. Updated format and Company name. Rev B 5 of 5