Software for HOBO loggers

Similar documents
Onset Computer Corporation 470 MacArthur Blvd. Bourne, MA Part #: MAN-BHW-GS Doc #: B. 28 HOBOware Getting Started Guide

BoxCar Pro 4.3 for Windows

HOBOware User s Guide 1

Contacting Onset. Copyrights and Trademarks

Contents. Contents... 1 Introduction... 4 An Overview of HOBOware... 4

Contents. Onset Computer Corporation 470 MacArthur Blvd. Bourne, MA Contents Introduction... 3 An Overview of HOBOware...

HOBOware User s Guide

Getting Started. onset computer corporation. Software for HOBO Data Loggers & Devices

HOBOware User s Guide

Getting Started: Using HOBOware with HOBO Data Loggers

Contents. 2 Getting Started: Using HOBOware with HOBO Data Loggers

Contents. 2 Getting Started: Using HOBOware with HOBO Data Loggers

For HOBOware Pro Software. User s Guide

Wind Speed and Direction Logger Kit

USB-5100 Series Multi-Channel Data Loggers

USB-5100 Series Multi-Channel Data Loggers

HOBO Waterproof Shuttle (U-DTW-1) Manual

onset computer corporation Lite HOBOware Software for HOBO Data Loggers & Devices User s Guide Doc #: C

PRODUCT CATALOG. Data Loggers External Sensors Software Accessories

HOBO Temp Data Logger (UX ) Manual

HOBO Temp/RH 3.5% Data Logger (UX ) Manual

HOBOlink User s Guide

Technology Primer. HOBO Data Nodes: Advanced Technology for Wireless Energy and Environmental Monitoring

HOBO State Data Logger (UX90-001x) Manual

HOBO State Data Logger (UX90-001x) Manual

HOBO Temp/RH 2.5% Data Logger (UX ) Manual

Logger Pro 3. Quick Reference

GS828-H. GPRS Data Logger

For HOBOware Pro Software. User s Guide

SensIT Test and Measurement Version Software Manual

FUTEK USB Software Version User s Manual

Automatic Reporting. Real-Time and Wireless Recording and Alarming

PC APPLICATION SOFTWARE WEATHER OS (MODEL: WMR100 / WMR200 / WMRS200 / I300 / I600 / EMS100 / RMS300 / RMS600) USER GUIDE IMPORTANT: LAUNCH SOFTWARE

Software.

HOBO Motor On/Off Data Logger (UX90-004x) Manual

HOBO External Temp/RH Data Logger (UX ) Manual

HOBO Light On/Off Data Logger (UX90-002x) Manual

HOBO Occupancy/Light Data Logger (UX90-005x/-006x) Manual

HOBO Occupancy/Light Data Logger (UX90-005x/-006x) Manual

HOBO MX1101 Temperature Data Logger

Mobile High-Speed Internet. Quick Start Guide. Motorola w100 4G USB Data Card Windows/Mac compatible

A subscription determines what BaseManager and Mobile Access features a controller has access to.

HOBO U-Shuttle (U-DT-x) Manual

3-Axis G-Force Datalogger

BESANTEK USB Data Logger Instructional Manual (BST-DL10, BST-DL13, BST-DL14)

Product Specifications

HOBO MX1101 Temperature Data Logger

BoxCar Pro 4.3 User s Guide

Procédés, Test et Mesure, Métrologie, Automation

Patrol Management Online Report System

Temperature/Rh Data logger. Users Manual. USB Datalogger IP 65 Water Proof

testo Comfort Software Basic 5

Standard Model Digital Force Gauge ZTS series

HOBO Energy Monitoring. Product Selection Guide

SITE-LOG LFVB. Product Specifications

ilive Editor V1.54 Release Notes November 2009

System Requirements Operating System Windows XP, Windows Vista >512 MB RAM CPU speed >2,5 GHz CD-ROM drive USB or parallel interface Important

GS828. GPRS Data Logger

Copyright 2009 by Scholastic Inc. All rights reserved. Published by Scholastic Inc. PDF0090 (PDF)

HOBO U-Shuttle (U-DT-x) Manual

Its 16-bit ADC makes ilog data loggers well suited for science and laboratory applications where precise and accurate measurements are critical.

HH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual

TSM - Temperature Sensor Meter

SUMMARY. Minimum required configuration... Software installation... User logo customisation... Software Un-installation... Launching application...

Download Center Windows downloads Update to Windows 8.1 Free Downloads Internet Explorer Office downloads Drivers (sound, printer, USB, more).

CENTER 521 INSTRUCTION MANUAL 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S)

DataFlow. DataFlow. Electronics & Software. Quality Monitoring System. DataFlow Statistics. Type 2805A...

Vaisala Veriteq VL 2000 Temperature Humidity Loggers

Humidity & Temperature Datalogger

Hand-Held Thermometer Model CTH 6200

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151

zloggmanager User Guide Release /12/2018

12-Bit 0-5 Volt Input Adapter (Part # S-VIA-CM14)

KeyTag Manager User Guide. Release /02/2017

w w w. z i g s e n s e. c o m. a u

HDT-318 Thermo-Hygrometer with Data Logger. (Air Humidity/Temperature) Instruction Manual

Handheld hydraulic readouts & dataloggers

HOBOmobile User s Guide

Hand-held thermometer Model CTH6200

Standard Model Digital Force Gauge ZTS series

USB Temperature and Humidity Data Logger Instruction Manual

SITE-LOG LPTH-1. Product Specifications. recognizes it and handles the configuration, downloading, graph viewing and more OVERVIEW

Specifications FEATURES

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

2YL-T15-4M & 2YL-T16-4M Thermocouple Loggers. 2YL-M36-4M & 2YL-M37-4M Multi Terminal Input Loggers. 2YL-M61-4M & 2YL-M62-4M Lux Loggers

Handheld hydraulic readouts & dataloggers

Remote Water Level Monitoring Technical Note Product: HOBO RX3000 Station

3-Axis G-Force Datalogger

User s Guide. OM-EL-WiFi-TH. Temperature/ Humidity. Data Logger. Shop online at omega.com OM-EL-GFX-DTC. Dual Channel Thermocouple Data Logger

Thank you for choosing Loadstar Sensors. Need additional help? Call us at or us at

Part Numbers SNAP-IT-EMU1

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC

User s Guide. OM-EL-WiFi-TH. Data Logger. Shop online at omega.com. Temperature Data Logger With Graphic Screen

Manual Internet Explorer 8 For Windows Xp Sp2 32 Bit

USB-5100 Series. USB Data Loggers for Windows and Mac. Software Help

Full HD WDR Mini Dome IP Camera

Specification for temperature sensor calibration setup

CS200 DIGITAL MFC SOFTWARE 2.0

Temperature & Humidity Datalogger

INDOT PAVEMENT SUBSURACE CONDITION EVALUATION SOFTWARE MANUAL. Version 1.0

Transcription:

Measurement, Control, and Datalogging Solutions Software for HOBO loggers HOBOware Software Pro and Lite versions HOBOware Pro is available for both for Windows and MAC and is Onset's most powerful software for logger management, data graphing, data analysis, and data export. Data Assistants such as Conductivity, Barometric Compensation, Linear Scaling, Pulse Scaling, kwh Assistant, Growing Degree Days, and Grains Per Pound are supported by HOBOware Pro software. HOBOware Pro software supports 21 CFR Part 11 compliance (see below). Data Assistants and Alarm & Readout Tool provide advance data analysis and monitor/notify out-of-range conditions. Lower-cost HOBOware Lite software is available for applications that don't require all the features of HOBOware Pro, but does not support HOBOware Data Assistants. A HOBO Base Station may be required to launch/download certain HOBO loggers. HOBOware Pro Software Setup & Status Checks Launching a logger is easy with HOBOware Pro software's launch screen. Launch parameters include: Which channels to record Logging interval (customizable from 1 second to over 18 hours) Immediate start, delayed start, start at interval, or triggered (push-button or coupler) start Set up linear scaling to user-defined units for 0 2.5V or 4 20mA inputs (U-series loggers only) Battery level indication Synchronizes logger's clock to computer's clock Check Logger Status Verify logger set-up before launch Verify logger operation while logging Display real-time sensor readings Display memory used and battery voltage MAC screen version shown D200/1

HOBOware specification continued Graphing HOBOware Pro software's powerful graphing features let you plot and filter data. View multiple parameters from one or more loggers on one graph Combine data from multiple deployments on one graph Overlay data from different time periods to compare month-to-month, or before and after Copy and paste data from one plot onto another Save and recall graphs saves all modifications including added data series and derived data such as barometrically compensated water levels Import text data files in BoxCar Pro format Zoom and axis-control tools to focus on data of interest Use cursor to display specific plot value Display series data and details such as launch parameters and series statistics Add limit lines to the graph Control axes, series, legend, and title properties Optional display of recorded events such as button push/release, host computer connection, and/or low battery in graphs or file exports Analysis Analysis functions can be used to extract key information from logged data. These functions actually create new data series, which can be graphed or exported. These functions filter data over user-specified intervals that can be in seconds, minutes, hours or days. The Subset Statistics tool (included) calculates statistics over a user-defined interval. Analysis functions for interval-based logger data: Min, max, and average values per interval Total rainfall or counts per interval Analysis functions for On/Off and State logger data: Run-time and off-time (closed time and open time) in seconds Percent on and percent off(percent closed and percent open) Number of on s and off s (number of opens and closes) Analysis functions for Event logger data: Number of events Cumulative event totals Subset Statistics Tool (HOBOware Pro only) get basic statistics for any subset of data within a graph The Subset Statistics Tool allows the user to select a range of data in a graph. The tool displays the maximum, minimum, average, and standard deviation for the measurements in that range. D200/2

HOBOware Data Assistants Onset is continuing to develop user-friendly Data Assistants to make analysis of your data even easier. Most Data Assistants are included with standard releases of HOBOware Pro, such as Conductivity, Barometric Compensation, Linear Scaling, Pulse Scaling, kwh Assistant, Growing Degree Days, and Grains Per Pound. Conductivity The Conductivity assistant provides easy conversion to specific conductance and salinity and enables start/end-point calibration to compensate for any fouling.. Growing Degree Days Growing Degree Days is a measurement of growth potential given historical temperature data. It can be a measure of crop or pest maturity, given the input parameters. Grains per Pound Also known as Humidity Ratio or Mixing Ratio, Grains Per Pound is a measure of the mass in grains of H 2 O in otherwise dry air. Barometric Compensation The Barometric Compensation Assistant compensates water level measurements for barometric pressure using HOBOware or text barometric files. Linear Scaling Linear scaling allows you to convert raw logger data to measurement units or to calibrate sensor readings. Two raw values and the corresponding measurement values are entered to obtain the linear scaling relationship. This is useful for third-party sensors that output voltage or current, as well as calibration of leaf wetness and soil moisture sensors. Pulse Scaling Pulse scaling allows you to convert data recorded from a third-party pulse output sensor to the actual measurement units. This is useful for third-party rain gauges, flow meters, etc. kwh Assistant The kwh Assistant uses a pulse series to produce one or more of the following: Energy used per interval (in kwh), Average Power per interval (in kw), and Usage Cost. The assistant requires knowledge of the type of Energy Transducer and Current Transformer (CT) used. D200/3

HOBOware Lite Software Entry-level software for HOBO USB loggers, offering easy logger launch, readout, and data plotting. Compare Software Features Pro Lite HOBOware Lite does not support any of Onset's data assistants or data shuttles. Setup & Status Checks Launching a logger is easy with HOBOware Lite software Launch parameters include: Which channels to record Logging interval (1 second to over 18 hours) Immediate start, delayed start, start at interval, or triggered (push-button or coupler) start Set up linear scaling to user-defined units for 0 2.5V or 4 20mA inputs (U-series loggers only) Battery level indication Synchronizes logger's clock to computer's clock Check Logger Status: Verify logger set-up before launch Verify logger operation while logging Display real-time sensor readings Display memory used and battery voltage Software Information 21 CFR Part 11 Systems Requirements using HOBOware Pro Software (Version 2.3 or above) and customers computer systems and internal procedures. Support for HOBO U-Series Loggers * * File support for HOBO H-Series Loggers * Support for HOBO Weather Station, HOBO Micro Station, and HOBO Energy Logger * Pro loggers Support for HOBO Conductivity Logger * Configure HOBO FlexSmart modules * Support for HOBO U-Shuttle and HOBO Waterproof Shuttle * Launch supported loggers * * Launch time-saving options * Graphing and analysis with ability to view multiple data files on one graph * * Cropping a series * Merging data files * * Readout and open-file time-saving options * Filters to extract key series information * * Subset Statistics Tool * Save (Project) Changes * * Import ASCII text data * Export ASCII text data * * Export to directly to.xls (Excel) format * * Check Logger Status and view current readings * * Data Assistants for Grains per pound, Growing degree days, Linear Scaling, Pulse * Scaling, and kwh(included with software) HOBOware Setup Assistant * Bulk Export Tool * Alarm Readout Tool * Ability to add other plug-in tools * Access remote loggers through Ethernet (requires supported Ethernet server) * 21 CFR Part 11 Regulation Reference Sec. 11.10 Controls for closed systems - Persons who use closed systems to create, modify, maintain, or transmit electronic records shall employ procedures and controls designed to ensure the authenticity, integrity, and, when appropriate, the confidentiality of electronic records, and to ensure that the signer cannot readily repudiate the signed record as not genuine. Such procedures and controls shall include the following: (a) Validation of systems to ensure accuracy, reliability, consistent intended performance, and the ability to discern invalid or altered records (b) The ability to generate accurate and complete copies of records in both human readable and electronic form suitable for inspection, review, and copying by the agency. (c) Protection of records to enable their accurate and ready retrieval throughout the records retention period. Provided by: Onset HOBOware Pro Customer systems Notes (HOBOware Pro Software only) NIST-traceable temperature accuracy certification available for loggers for an additional fee. Test files are included with HOBOware Pro that can be used to verify it is properly detecting files that have been altered. Electronic records produced by HOBOware Pro can be viewed with HOBOware Pro or HOBOware Lite, and can be printed from either of these as well. Secure electronic copies of files can be made and shared by e-mail or other electronic transfer methods. HOBOware Pro stores the electronic records in the location specified by the user. The customer systems must ensure that these files are backed up regularly, and that the data files are stored in a location where they can be readily available on request. The computer system must have sufficient redundancy to prevent loss of data. D200/4

Software Information HOBOware 3.2.1 is built with Java 1.6.0_25 on Windows and on OS X. While HOBOware may run using a previous or later version of the Java JRE, version 1.6.0_25 is recommended as a baseline. Use of Java v1.4.x and Java 5 are specifically no longer supported. HOBOware 3.2.1 on Mac is built for OS X 10.5 as a minimum. While HOBOware may run using a previous version of OS X, earlier versions of OS X are specifically no longer supported. Regardless of the Java runtime version in use, it is up to every user to ensure that their Java installation is up to date regarding the Olson Timezone Database for their locale. Please review the following website: www.oracle.com/technetwork/java/javase/timezones-137583.html ***Disk Space Defining the disk space requirements for HOBOware depends on the proposed use. The table above describes the disk space needed for a traditional desktop user, allowing for installation of the program and storage of data files. For users of HOBO nodes the space requirements depend on a variety of factors, including the number of nodes, the number of sensors, the frequency of data sampling, the longevity of deployments, and other factors. Please review the following website: www.onsetcomp.com/support/knowledgebase System Requirements PC: Windows 7 (Pro, Ultimate and Home Premium), Windows XP Pro, Windows XP Home, Vista Business, Vista Home Premium Mac: OS X Versions 10.5.x and 10.6.x. Java Runtime Environment (JRE) 1.6 (32-bit or 64-bit on Windows). Please note that version 1.6, also known as Java 6, is officially supported on OS X only on Intel Core 2 Duo processors or newer. See the time zone note below. One of the following Internet browsers (version number listed is the highest major version we tested): Safari 4 or greater, Firefox 3 or greater, Microsoft Internet Explorer 8.0. Minimum screen resolution of 1024x768 256+ colors Processor Speed, Memory and Disk Space High End Mid Range Low End Lowest End 1.8 CPU 2.9 GHz dual 2.0 GHz dual 1.8 GHz single GHz core core core single core RAM 3 GB 2 GB 1.5 GB 1 GB Disk Space User Model 300 MB 4 3 2 1 The User Model row suggests some guidelines for using the Processor Speed and Memory table: User Model 1 - Using HOBO Data loggers only, no data nodes traditional desktop user User Model 2 - Using HOBO Data loggers and up to 5 data nodes, 20 sensor User Model 3 Using HOBO Data loggers and up to 50 data nodes, 100 sensors User Model 4 Using HOBO Data loggers and up to 100 data nodes, 200 sensors Ordering Information: HOBOware Pro Software for Windows/MAC (CD-Rom) HOBOware Lite Software for Windows/MAC (CD-Rom) USB interface cable for U-series Loggers to PC (Supplied with BHW-PRO-CD and BHW-LITE-CD software) Part No BHW-PRO-CD BHW-LITE-CD CABLE-USBMB D200/5