Remote Calibration. Connect the WireScope/FrameScope 350 and DualRemote 350 per either of the configurations below.

Similar documents
Agilent Technologies N2600A WireScope 350. User s Manual. Agilent Technologies. Version 3.0

ScopeData Pro User s Guide

Field-testing procedure. LANmark-6

Agilent N2640A WireScope Pro

WireScope 155 SCOPE. Agilent Wirescope 155 Specs Provided by The Performance Leader in Hand-Held Network Tools

Psiber Data WireXpert P R O F E S S I O N A L N E T W O R K T E S T I N G & P R O T O C O L A N A L Y S I S

Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved.

CL600 SIMPLE LOGGER RMS CLAMP-ON MODULE E N G L I S H. User Manual

Keysight U1610/20A Handheld Digital Oscilloscope. Quick Start Guide

Appendix 1 to the R&Mfreenet Warranty Program

Basic Setup for the Current Probes Input Option

Ball Probe Moisture Meter With Bluetooth

EN Series / EXN. Telephone Entry & Access Control System. Quick Start Guide (EN-2A4) ( EXN )

SPRINT 4510 Release Note

Wireless keypad PRF-LCD-WRL

Net-Ritef Continuity and Wiremap Tester Trace-Ritef Tone Generator and Amplified Tone Tracer User's Guide.

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

TRIPLETT WireMaster Mapper

Net Prowler TM Identify, Monitor & Test LAN Issues

L610 L620 L630 SIMPLE LOGGER THERMOCOUPLE MODULE E N G L I S H. User Manual

AquaController Apex Probe Module 2

TDR Cable Fault Locator Operating Instructions

Operating Instructions. LSP-KONSTANTER Series 32K Laboratory Power Supply 8/10.13

Gazer VI700A-NTG45 and VI700W-NTG45 INSTALLATION MANUAL

Using SIMDIS Expert 9 (Separation Systems) with Clarity

BiPAC 8501/8521. SHDSL.bis (VPN) Firewall Bridge/Router. Quick Start Guide

CH2 Performance Verification Manual For the CH2 using easy-wire software version 2009 or higher

USB 2.0 DIGI-USB2 1-Port USB m Category 5e/6/6a/7 Extender Set with Flexible Power. User Manual. Revision

Supplied with. Calibration certificate. TM 200 Thermometer

HypotULTRA. Quick Start Guide SAFETY CHECKLIST. Survey the test station. Make sure it is safe & orderly.

User's Manual IDAX Support Software Version Megger Sweden AB. Released in

Micro-Ohmmeter Model 6292

Thermal Transient Test

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Agilent Technologies VQT Phone Adapter J1996A

AirCheck Wi-Fi Tester Evaluation Guide

Windows System. Cannot connect the Internet or open the website

AC/DC Current Probe Model SL201

Mini Digital Multimeter

KNX USB INTERFACE UIMtp

User Manual EzLogger WiFi Ver 02

FLEX Ex Spring Clamp Terminal Base

OPERATION AND USE OF THE ANIMATICS EXTERNAL LCD DISPLAYS LCD2X20 (two line x twenty character display) LCD4X20 (four line x twenty character display)

Thermal Transient Test Installation and Operating Manual

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

Pointing Devices and Keyboard User Guide

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

DS1000B Series Digital Oscilloscope

USER S MANUAL. E6 POKEYS MOTION CONTROLLER CNC INTERFACE DB25 Rev.1

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

SEI DC-UPS Power Management Package Users Manual

Quick Installation Guide

DVG-6008S FXO VoIP Router

Net Prowler TM. Identify, Monitor & Test LAN Issues Quick Start Guide TNP700 TNP800 TNP850K1

User's Guide. Extech AM A AC Analog Clamp Meter

mini USB ISDN TA128 User s Manual

9040/9040UK. Users Manual. Phase Rotation Indicator

HI ma Simulator

AquaController Apex Probe Module 2

Getting Started Guide

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

GigaStor Upgradeable 2U. User Guide

BiPAC 8501 R3/ 8521 R3

The MSM335 is a Wi-Fi Alliance authorized Wi-Fi CERTIFIED product. The Wi-Fi CERTIFIED Logo is a certification mark of the Wi-Fi Alliance.

Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

USER MANUAL Bluetooth Wireless Stereo Headphones with Headset Functionality

Operating instructions. Switching amplifier DN0210 DN / / 2015

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

BEC 5200 Series. (802.11g) ADSL2+ Router. Quick Start Guide


GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

HI ma Simulator

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

HT-1A Dual Band CW QRP Transceiver. User Manual

SGE-3G/GPRS INSTRUCTION MANUAL (M179B A)

TA330 HAND HELD AUTOMOTIVE SINGLE CHANNEL OSCILLOSCOPE AND MULTIMETER

Copper Certification Testing Best Practices Pocket Guide

3081 Test Leads Test Leads Test Leads

What can the DD700 Do

AVANT REM Speech Manual Rev. 1 Effective 10/05

Features: DS54 v1.0 DIN rail mounted switch 5-port DS54 for 4 IP cameras without power supply

SensoTrans DMS A 20220

OX 5022-CK OX 5042-CK

AquaController Apex Probe Module 1

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

EnerSure Installation Guide

Qualified Partner Programme QPP. Cat.6 Channel Meassurement Issues Felice Guarna

Demonstration Case BENNING DB 1

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

Serial PROFIBUS Interface

MobilePro Users Guide Page 1 of 35. MobilePro HPC. User's Guide. Notices Proprietary Notice and Liability Disclaimer Table of Contents

QUICK START GUIDE. Aleratec 1:15 DVD/CD Tower Publisher SLS. Part No

BiPAC 5200 Series. (802.11g) ADSL2+ Modem/Router. Quick Start Guide

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

Product User Guide PR2000. PR2000 Pressure Data Logger with LCD

USB 2.0 RG2304GE-LAN. 4-Port USB 2.0 Gigabit Ethernet LAN Extender System. User Guide

User Manual Fiber Certification Testing

Transcription:

The Autotest is the function users run most frequently. The Autotest function is designed to provide certification testing of installed cabling. Remote Calibration Before you run the Autotest, however, it is important to verify that you have properly prepared the WireScope/FrameScope 350 for your certification project. Before you begin testing, it is necessary to calibrate the WireScope/FrameScope and DualRemote pair that you will use. Remote calibration is a process that allows the WireScope/FrameScope to compensate for any slight anomalies in its measurement hardware or that of the companion DualRemote unit. Connect the WireScope/FrameScope 350 and DualRemote 350 per either of the configurations below. Channel Probe Link Probe OR Precision Calibration Cable If you are testing link configurations to Category 6 / Class E or higher, Agilent Technologies recommends that you use the precision calibration cable, as this produces the most accurate calibration. From the main menu screen, press Calibration. Follow the instructions to complete the calibration process. 1

Test Probes SmartProbe Interface SmartProbe Port Interface The WireScope/FrameScope 350 uses test probes to connect to the cabling runs that it certifies. All WireScope/FrameScope 350 test probes attach though the SmartProbe port at the top of the WireScope and DualRemote enclosures. The SmartProbe port provides high performance for test signal transmission, power to support active probes, and a two-way control interface between the tester and the test probe. A variety of test probes are available, including SmartProbes that track usage and configuration data. WireScope probe configuration warnings Because it is important to use the correct test probes in order to achieve optimal measurement results, particularly for category 6 installations, the WireScope 350 warns you whenever it detects a potential conflict between the detected probe and any of the test settings. This you to avoid wasting time testing with the wrong probes or with the wrong tester settings. If the WireScope detects an over-voltage condition at the SmartProbe port, it displays an error message An example of this warning is provided below: If the DualRemote detects an over-voltage condition at the SmartProbe port, the overvoltage LED is lit. CAUTION: Do not connect WireScope test probes or test cables to a voltage source, such a telephone jack. Excessive voltages can damage WireScope probes and/or the WireScope 350 analyzer and void your warranty. 2

Quick Start Guide You can use the WireScope/FrameScope 350 with basic settings. To do this for link or channel tests, insert the required Basic Link or Channel Adapters as required in both the WireScope 350 and DualRemote 350. Then, turn both units on and calibrate as previously directed. Software Version 3.0 and higher has two modes of user interface operation, normal and expert and supports both FrameScope 350 and WireScope 350. If your unit is a WireScope, tabs at the top of the screen will not be present. The normal mode is shown on the left below and expert mode is shown on the right. To change from one mode to the other tap System, which brings up the System settings screen, where you will tap User interface and Edit to bring up the User Interface Setup screen. Tap Expert Mode to turn on and off Expert Mode, then OK and Main Menu. Note that the software Contrast setting may not be available on your unit depending on the version of hardware. 3

Normal Mode If your unit is in normal mode user interface, the Main Menu screen will have a button for either Class D/Category 5E or Class E/Category 6 testing unless a specific profile is selected. Before testing, tap Setup to bring up the Normal Mode Autotest Setup screen. Your setup choices in the normal mode are restricted to profile, standard, site, cable type, connector type, and cable pairing. If you are testing an unknown cable, you may leave them all at the default except for the standard choice, which should match your requirements. Testing is as simple as tapping the category or class you want to test. After the test is completed the Autotest result summary screen is displayed. At this point you can Save the test data, review Details of the test, or Start a new test by tapping the Start button on the summary screen. 4

Expert Mode Starting at the Main Menu, tap Autotest. This brings up the Autotest Setup screen. Tap Select Settings Profile. The Select Settings Profile screen is displayed, enabling you select a stored profile. For our example, select Default Cat 5e. Click OK to return to the Autotest Setup screen. Connect the WireScope 350 and the DualRemote 350 to the cable to be tested. Then tap Start to begin the test. The Autotest result summary screen is displayed. At this point you can Save the test data, review Details of the test, or Start a new test by pressing the Start button on the summary screen. 5 Pub # 5988-6951EN