USB-BASED 8-CHANNEL DATA ACQUISITION MODULE

Similar documents
USB-Based 14-Channel Data-Acquisition Module

USB-Based 20-Channel Data-Acquisition Module

USB-Based 14-Channel Data-Acquisition Module

Evaluation Boards for the DLP-USB245M USB Adapter

The DLP-USB232R is available in a lead-free (RoHS compliant), compact 18-pin, 0.1-inch standard DIP footprint.

USB-Based Temperature & Humidity Sensor

BASIC FEATURES APPLICATIONS ** PRELIMINARY DOCUMENT-SUBJECT TO CHANGE **

VINCULUM-BASED TEMPERATURE / HUMIDITY / VOLTAGE DATA LOGGER FEATURES:

FEATURES: 1.0 INTRODUCTION

DLP-FLASH USB-Based FLASH Programmer

FEATURES: 1.0 INTRODUCTION

PRELIMINARY Prototyping Platform for the DLP-RF2 Transceiver

TTL-232R-PCB. TTL to USB Serial Converter PCB. Datasheet

FERROELECTRIC MEMORY-BASED MICROCONTROLLER MODULE

QSFP Breakout. Data Sheet. Datasheet QSFP Breakout. 1 Overview. Table of Contents. 2 Features

Shown here with the TI G2 LaunchPad (Sold Separately)

TTL-232R-PCB. TTL to USB Serial Converter PCB. Datasheet

Future Technology Devices International Ltd. USB to RS422 Serial Converter Cable. Datasheet

Future Technology Devices International Limited

UB232R. USB Mini-B FT232R Evaluation Module. Datasheet

DLP-245SY-G *LEAD-FREE*

SFP+ Breakout 2. Data Sheet. Datasheet SFP+ Breakout. 1 Overview. Table of Contents. 2 Features

USB-I2C USB to I2C Communications Module Technical Specification

USB485 USB to RS485 Converter Card

FT4232H-56Q Mini Module. USB Hi-Speed FT4232H Evaluation Module. Datasheet

Phocos CX-I. Installation Guide

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

USB485. USB to RS485 Converter Card. User Manual for connecting with Windows Vista Version 1.01

Future Technology Devices International Ltd. FTDI Drivers Installation guide for. Windows 7

Future Technology Devices International Ltd USB TO RS485 UART SERIAL CONVERTER PCB. Datasheet

Fox Thermal Instruments, Inc.

USB to RS-422 / 485. US USB To Serial Operation Manual

USB / Microcontroller Module

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

NHD-0216K3Z-NS(RGB)-FBW-V3

NHD-0220D3Z-FL-GBW-V3

8K X 8 BIT LOW POWER CMOS SRAM

Flex Series User Guide

What is NXTCam. NXTCam Feature List. What you will need before using NXTCam. NXTCam v2 User Guide

GRAVITECH GROUP

Preliminary. PACKAGE - 28-pin MLP (5mm X 5mm) Example Circuit Diagram CP V. 48MHz Oscillator. USB Function Controller 512B EEPROM

MCCMDB-16SIL. Description of change

Command Processor For MPSSE and MCU Host Bus Emulation Modes

I2C-AO112DIx I2C-Bus 4-20mA Analog Output Boards Din-Rail supports

USB / Microcontroller Module

Nuvoton Touch Key Series NT1160 Datasheet

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

SC2004MBS 20x4 Characters MODBUS RTU Slave LCD

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

Fox Thermal Instruments, Inc.

USB RS485 High Isolated Industry Converter Box for DIN Rail - product #248

Sigma DeviceNet Tool Change Systems USER S GUIDE Rev 05

Future Technology Devices International

Logosol Joystick Node LS-731

CP2102-EK CP2102 EVALUATION KIT USER S GUIDE. 1. Kit Contents. 2. Software Setup Virtual COM Port Driver Installation

1320 Electronics LLC USB-ALDL Cable User s Guide Electronics LLC. User s Guide for: USB-ALDL Cable

RF RF 433MHz Transceiver Module

NHD-0220D3Z-FL-GBW-V3

TTL-234X. TTL234X Series Range of Cables. Datasheet

1. General Description

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 2 Art. no.:

NeoLoch. Inquisitor 4116 DRAM Blade Manual. Overview. Preliminary Release

SENSYLINK Microelectronics Co., LTD. (CT1820S) Single-Wire Digital Temperature Sensor

DS2756EVKIT+ High Accuracy Battery Fuel Gauge With Programmable Suspend Mode Evaluation Kit

NATIONAL CONTROL DEVICES Push Notification - Serial Quick Start Guide

OEM-MICODE (MIFARE ICODE)

Cytron USB to UART Converter UC00A

Futaba MDM166A display

EE870 Modular CO 2 Transmitter

Dual Serial Shield User Manual

FT2232H Mini Module. USB Hi-Speed FT2232H Evaluation Module. Datasheet

Figure 1: TSSOP-24 ( Top View ) Figure 2: TQFN 4x4-24 ( Top View )

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

I/O232-A User s Guide

OEM-ORP ORP. Reads mV mV. Range. 1 reading every 420ms. Response time. Any type & brand. Supported probes. Single point.

TTL-232R. TTL to USB Serial Converter Range of Cables. Datasheet

Model 6813 THERMO-ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA. (800) Fax: (973)

Table 1. RS232 Serial Adapter DEBUG Connector Pin Descriptions

RS485 MODBUS Module 8I8O

USB-1208LS Specifications

Installation Operation & Specifications Manual. General Description

USB-COM485-PLUS1. Datasheet

TS2043 Preliminary CMOS IC

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

ED1021 I/O Expander with UART interface & analog inputs

HMC1022 Digital Compass

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

[WIR-1286]868MHz LORA Wireless Module. Page 1. LORA 868MHz Wireless serial link [WIR-1286]

udrive-usd-g1 Embedded DOS micro-drive Module Data Sheet

Programming and Evaluation Tool for Serial EEPROMs

AU5017. General Description

ATtiny104 Xplained Nano. Preface. AVR 8-bit Microcontrollers USER GUIDE

USER GUIDE. Atmel OLED1 Xplained Pro. Preface

SY89645L. General Description. Features. Block Diagram. Applications. Markets. Precision Low Skew, 1-to-4 LVCMOS/LVTTL-to-LVDS Fanout Buffer

RangeWizard User Guide v1.0. User Guide. v1.0. Summerour Robotics Corp ( RangeWizard Copyright

D8000 SERIES QUICK START GUIDE

ED1021 I/O Expander with UART interface & analog inputs

Quick Start Installation Guide

NHD 0216K3Z FL GBW. Serial Liquid Crystal Display Module

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

Transcription:

DLP-IO8-G *LEAD-FREE* USB-BASED 8-CHANNEL DATA ACQUISITION MODULE Features: 8 Channels: Digital I/O, Analog In, Temperature USB Port Powered USB 1.1 and 2.0 Compatible Interface Small Footprint; Easily Fits on Desktop Easy to Use with Single-Byte Commands - Can Utilize a Simple Terminal Emulator to Control All Functions Applications: Data Acquisition Industrial/Process Control Process Monitoring 1.0 INTRODUCTION The DLP-IO8 Data Acquisition Module is a low-cost, easy-to-use data acquisition system for measuring voltages, controlling and monitoring processes, and acquiring temperature data. Each of the 8 available channels can be configured for any of the digital, analog, or temperature modes via single-byte commands. All operational power is taken from the host PC via the USB port. The mode of each I/O is automatically changed with each command sent. For example, if an I/O is set to Digital Output High and then the Digital Input Mode is selected, the I/O is first changed to Input Mode and then the high/low state is read and returned to the host. 2.0 SPECIFICATIONS The DLP-IO8 is a 5-volt system that derives its power from the host USB port. Each channel has the following capabilities: Digital Output: Set high, or clear to low. (The actual high/low voltage depends upon sink/source current.) Digital Input: Read the high/low state. Analog In: Read and return the voltage on each I/O pin using a 10-bit A/D: 0-5 volt range. Temperature: Measure temperature using a DS18B20+ digital temperature sensor (purchased separately) in the range of 67 to 257 F (-55 to 125 C). Rev. 1.6 (March 2013) 1 DLP Design, Inc.

3.0 ABSOLUTE MAXIMUM RATINGS Stresses above those listed here may cause permanent damage to the DLP-IO8: Operating Temperature: 0-70 C Voltage on I/Os with Respect to Ground: -0.3V to +5.3V Sink/Source Current on Any I/O: 25mA 4.0 WARNINGS Unplug from the host PC before connecting to the DLP-IO8. Isolate the bottom of the board from all conductive surfaces. Observe static precautions to prevent damage to the DLP-IO8 module. 5.0 USB DRIVERS USB drivers for the following operating systems are available for download from the DLP Design and FTDI websites: Windows 8 Windows 7 Windows Server 2008 R2 Windows Vista Windows XP Mac OSX Windows Server 2003 Mac OS9 Windows 2000 Mac OS8 Windows 98, ME Linux NOTE: If using the dual mode drivers from FTDI (CDM2.00.00) and you want to use the Virtual COM Port (VCP) drivers then it may be necessary to disable the D2XX drivers first via Device Manager. Right click on the entry under USB Controllers that appears when the DLP-232PC is connected, select Properties, select the Advanced tab, put a check in the option for Load VCP and click OK. Unplug and replug the DLP-232PC and a COM port should appear in Device Manager under Ports (COM & LPT). 6.0 USING THE DLP-IO8 Simply connect the DLP-IO8 to the PC to initiate the loading of drivers. Once the drivers are loaded, the DLP-IO8 is ready for use. All commands are single-byte commands. You can either utilize a simple terminal emulator program, or write your own program in your language of choice. Begin by opening the COM port, set the baud rate to 115200, and send single-byte commands as shown in Table 1. The Ping command can be used to locate the correct COM port used for communicating with the DLP-IO8, or you can look in Device Manager to see which port was assigned by Windows. TABLE 1 Channel 1 Commands ASCII Character Hex Value Description Return / Comments 1 0x31 Dig Out High Nothing returned Q 0x51 Dig Out Low Nothing returned Rev. 1.6 (March 2013) 2 DLP Design, Inc.

A 0x41 Digital Input Returns 0 or 1 (See Note 1) Z 0x5A Analog In Returns measured voltage (See Note 1) 9 0x39 Temperature Returns current temperature (See Notes 1 and 2) Channel 2 Commands 2 0x32 Dig Out High W 0x57 Dig Out Low S 0x53 Digital Input X 0x58 Analog In 0 0x30 Temperature Channel 3 Commands 3 0x33 Dig Out High E 0x45 Dig Out Low D 0x44 Digital Input C 0x43 Analog In - 0x2D Temperature Channel 4 Commands 4 0x34 Dig Out High R 0x52 Dig Out Low F 0x46 Digital Input V 0x56 Analog In = 0x3D Temperature Channel 5 Commands 5 0x35 Dig Out High T 0x54 Dig Out Low G 0x47 Digital Input B 0x42 Analog In O 0x4F Temperature Channel 6 Commands 6 0x36 Dig Out High Y 0x59 Dig Out Low H 0x48 Digital Input N 0x4E Analog In P 0x50 Temperature Channel 7 Commands 7 0x37 Dig Out High U 0x55 Dig Out Low J 0x4A Digital Input M 0x4D Analog In [ 0x5B Temperature Channel 8 Commands 8 0x38 Dig Out High I 0x49 Dig Out Low K 0x4B Digital Input, (Comma) 0x2C Analog In ] 0x5D Temperature Rev. 1.6 (March 2013) 3 DLP Design, Inc.

Setup Commands (Remembered Until Power is Cycled) ` 0x60 Return ASCII Default setting; nothing returned (Accent Grave character just left of the 1 key) \ 0x5C Return Binary Nothing returned L 0x4C Set F Default setting; nothing returned ; 0x3B Set C Nothing returned Ping Command 0x27 Issue Ping Q (0x51) will be returned if the DLP-IO8 is found on the selected port (Apostrophe character just right of the ; key) Note 1 Data is returned in either the form of ASCII characters (ex: 1.25V, 78.2 F) or binary (raw data) depending upon the current mode. The power-up default mode is ASCII mode such that data is easily read using a terminal emulator program. Note 2 Requires DS18B20 digital temperature sensor (purchased separately). See Section 7.0 of this document for connection details. 7.0 TEMPERATURE Up to eight DS18B20+ digital temperature sensors can be connected to the DLP-IO8. For best performance, use Cat 5 type computer cable to connect the sensors to the DLP-IO8. Two pairs of wires in the Cat 5 cable are required for the connection. The first pair is for Power (5V) and Ground, and the second pair is designated as Data and Ground. In addition, a pull-up resistor is required for the data line of approximately 1.5K Ohms. Figure 1 shows an example of this connection using I/O Channel 1: 5 6 7 8 GND 5V 1 2 3 4 1.5K Ohm Pin 1 DS18B20 1. GND 2. DATA 3. VCC DLP-IO8 FIGURE 1 The first time temperature data is requested, a value of 999.99 (0xFF x 2 if in Binary Mode) is returned. Subsequent reads will return valid temperature data if a temperature sensor is properly configured and connected to the specified I/O port. If no sensor is connected, a Temperature command will always return 999.99. Note 3 Cat5 cable lengths of greater that 100 feet may require a pullup resistor value of less than 1.5K Ohms in order to achieve usable rise times at the sensor. The minimum safe resistance for the pullup resistor is 240 Ohms. Rev. 1.6 (March 2013) 4 DLP Design, Inc.

8.0 RETURN DATA TYPES By default, the DLP-IO8 returns data to the host PC in the form of ASCII text such that it can be easily displayed and read using a simple terminal emulator. Alternatively, data can be returned in binary form requiring the user s host app to calculate the voltage and temperature values. The commands used to set the return data types (0x60 and 0x5C) are shown at the end of Table 1. 9.0 MECHANICAL DIMENSIONS IN INCHES (MM) (PRELIMINARY) 74.0 typ (1.88m typ) 0.140x2 typ (3.6 typ) 0.34 typ (8.7 typ) 5 6 7 8 GND 5V 1 2 3 4 2.47 typ (62.7 typ) 0.89 typ (22.6 typ) Rev. 1.6 (March 2013) 5 DLP Design, Inc.

10.0 DISCLAIMER DLP Design, Inc., 2006-2013 Neither the whole nor any part of the information contained herein nor the product described in this manual may be adapted or reproduced in any material or electronic form without the prior written consent of the copyright holder. This product and its documentation are supplied on an as-is basis, and no warranty as to their suitability for any particular purpose is either made or implied. DLP Design, Inc. will not accept any claim for damages whatsoever arising as a result of the use or failure of this product. Your statutory rights are not affected. This product or any variant of it is not intended for use in any medical appliance, device, or system in which the failure of the product might reasonably be expected to result in personal injury. This document provides preliminary information that may be subject to change without notice. 11.0 CONTACT INFORMATION DLP Design, Inc. 1605 Roma Lane Allen, TX 75013 Phone: 469-964-8027 Fax: 415-901-4859 Email Sales: sales@dlpdesign.com Email Support: support@dlpdesign.com Website URL: http://www.dlpdesign.com Rev. 1.6 (March 2013) 6 DLP Design, Inc.