Draft sensor KMB series 30

Similar documents
Draft sensor KMB series 30

Position sensor PO1 series 20

BODAS DCT Display Configuration Tool

BODAS Color Video Camera

BODAS-design. RE 95112/ /8 Replaces: Data sheet. Version 3.0. Contents. Features

Electronic Control Unit RC

BODAS Controller RC Series 21

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Mating connectors and cable sets for valves and sensors in hydraulics

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

EMC-Compatible Installation of the Electric Cabinet

Safety modules. 8/4 inputs PROFIsafe S20-PSDI8/4

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

Operating Instructions

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

Operating Instructions Differential Pressure Transducer PS27

Redundancy unit CP-A RU

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301

Operating instructions. Speed monitor D / / 2014

Installation instructions Inclination sensor EC2019 EC / / 2013

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

B63/ NS MS. EtherNet/IP LINK

Operating instructions. Switching amplifier DN0210 DN / / 2015

NOVOHALL Transducer 5 up to 50 mm touchless. Series TFD-4000

Operating instructions. Standstill monitor A / / 2011

Instruction Manual PU/PI and PS10 Differential Pressure Transducers

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Manual. Guardian Series Safety Compliant Melt Pressure Transducer

TEMPERIX S Clamp. FAFNIR GmbH Schnackenburgallee 149 c Hamburg Germany

Rexroth Controller Installation & Operations Manual

TRIO-DIODE/12-24DC/2X10/1X20

Instruction Manual. EXDC Turbomolecular Pump Drive Modules. Item Number

VARAN-INTERFACE VAC 012

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Industrial Hydraulics FAQs

MAXIMA+ Series Rotary Level Indicator

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

MAXIMA + Series ROTARY LEVEL CONTROL

Operating Instructions VEGAMET 381

BODAS Display DI3. RE 95270/ /12 Replaces: Data sheet. Series 10, " multifunction color display for mobile applications.

Level sensor Stainless steel version Model RLT-1000, for industrial applications

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

igus motion Plastics dryve D3, DC-Motor Control System

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

BNI IOL K023 BNI IOL K023. User s Guide

Mating connectors and cable sets for valves and sensors in hydraulics

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Original operating instructions Safety relay with relay outputs G1501S / / 2016

C9900-P223 and C9900-P224

BTL6-A_10-M -A1-S115. Data Sheet. english

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Temposonics Magnetostrictive Linear Position Sensors

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Inductive sensor BI1.5-EG08-Y1-H1341

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

LS 6600 Technical Datasheet

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

C9900-P208 and C9900-P209

Operating instructions Evaluation system for flow sensors VS / / 2013

MDM 011-Z1 Regen Resistor

Operating Instructions

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

User's Manual. english

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

Light Control SLS ADRIA

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

STEP-PS/1AC/24DC/1.75

BNI IOL K023 BNI IOL K023. User s Guide

RTU500 series Data Sheet Power Supply CP-E 24/2.5

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Operating instructions RFID evaluation unit DTE / / 2016

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90

Inductive sensor with analog output BI15-M30-LI-EXI

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042

Technology modules. 1 SSI interface for absolute encoders, 1 analog output S20-SSI-AO-1/1

Thomson Max Jac Electric Linear Actuator

Operating Instructions for Digital Thermometers. Model: DTM

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

Transcription:

Draft sensor KMB series 0 RE 95170 Edition: 07.2017 Replaces: 07.2017 Sensor for draft measurement Features Draft sensor according to Category rear three-point attachment (ISO 70-1) Sensor element with magnetoelastic measuring principle Integrated electronics Output signal ratiometric and proportional to draft Zero point and sensitivity are calibrated Contents Ordering code 2 Description Technical data 4 Characteristics 4 Dimensions 5 Connector 5 Cable versions 6 Installation instructions 7 Safety instructions 7 RE 95170/07.2017, Bosch Rexroth AG

2 KMB series 0 Draft sensor Ordering code Ordering code 01 02 0 04 05 06 07 KMB / 0 Type 01 Draft measurement pin KMB Load range 02 ±25 kn 025 ±40 kn 040 ±50 kn 050 ±60 kn 060 ±90 kn 090 ±110 kn 110 ±150 kn 150 ±160 kn 160 Supply voltage 0 5 ±0.5 V 05 8 to 12 V 10 Cable version 04 Cable without protective sleeve 1 Cable with spiral protective sleeve 2 Cable with metal protective sleeve Cable with plastic protective sleeve 4 Connector 05 AMP connector; -pin A DEUTSCH connector; -pin B Series 06 0 Cable length 07 800 mm 08 965 mm 09 1000 mm 10 1500 mm 15 1600 mm 16 1800 mm 18 2700 mm 27 Available variants Type Material number KMB 025 05 1 A / 0 15 R917007592 KMB 025 05 4 A / 0 08 R917008079 KMB 025 05 4 A / 0 15 R917008045 KMB 025 10 1 A / 0 15 R917000161 KMB 025 10 4 A / 0 08 R917000177 KMB 025 10 4 A / 0 10 R917000158 KMB 025 10 4 A / 0 15 R917000175 KMB 040 05 1 A / 0 15 R917008099 KMB 040 05 A / 0 15 R917008667 KMB 040 05 4 A / 0 18 R91700800 KMB 040 10 1 A / 0 15 R91700015 KMB 040 10 2 A / 0 27 R917000160 KMB 040 10 A / 0 15 R917000155 KMB 040 10 A / 0 15 R91700120 KMB 040 10 4 A / 0 08 R917000167 KMB 040 10 4 A / 0 16 R917000159 KMB 040 10 4 A / 0 18 R917000180 KMB 050 10 2 A / 0 08 R917000157 KMB 060 05 1 A / 0 15 R917008098 KMB 060 05 A / 0 15 R917008077 KMB 060 10 1 A / 0 15 R917000154 KMB 060 10 1 A / 0 15 R917000170 KMB 060 10 2 A / 0 27 R917000164 KMB 060 05 A / 0 15 R917008077 KMB 060 10 A / 0 15 R917000156 KMB 060 05 4 A / 0 18 R917008060 KMB 060 10 4 A / 0 08 R917000166 KMB 060 10 4 A / 0 15 R91700017 KMB 060 10 4 A / 0 16 R917000165 KMB 060 10 4 A / 0 18 R917000181 KMB 090 10 1 A / 0 15 R917000168 KMB 090 10 1 A / 0 15 R917000171 KMB 090 10 2 A / 0 27 R917001969 KMB 090 05 A / 0 15 R917008078 KMB 090 10 A / 0 15 R91700016 KMB 090 05 4 A / 0 18 R917008061 KMB 090 10 4 A / 0 15 R917000172 KMB 090 10 4 A / 0 18 R917000275 KMB 110 05 1 A / 0 15 R917005142 KMB 110 10 1 A / 0 15 R917000179 KMB 110 10 2 A / 0 08 R917000162 KMB 150 10 1 A / 0 15 R917A05986 Bosch Rexroth AG, RE 95170/07.2017

Draft sensor KMB series 0 Description Description The draft sensor is designed as a bearing bolt. Shearing Function principle stress occurs at the bearing position, which is evaluated as a magnetoelastic effect. In unloaded condition a symmetrical magnetic field is formed by the primary coil between the poles. If pulling or pressure drafts are induced, then the magnetic properties of the original isotropic material is altered. As a consequence, the magnetic field is rendered asymmetrical. This in turn induces a magnetic potential difference between the secondary poles. This causes a magnetic flux through the secondary circuit so that a voltage is induced in the secondary coils. This voltage is proportional to the acting draft. It is amplified and rectified in an integrated evaluation circuit. The sensor supplies a ratiometric voltage (25% to 75% of supply voltage). It is available with various measurement ranges and cable versions. This sensor is a typical part of an electro-hydraulic hitch control (EHC). This sensor is destined for the use in agricultural applications. A E A E A E 1 Primary coil 2 Secondary coil Primary pole surface 4 Secondary pole surface 5 Steel sleeve a Symmetrical magnetic field b Asymmetrical magnetic field Block circuit diagram F U 5 1 F 2 1 2 a F = O S N 4 Supply voltage U sup Signal voltage U sig b F O S N Ground GND RE 95170/07.2017, Bosch Rexroth AG

4 KMB series 0 Draft sensor Technical data Technical data Type 025 040 050 060 090 110 150 Load range F ±25 kn ±40 kn ±50 kn ±60 kn ±90 kn ±110 kn ±150 kn Standard overload range ±80 kn ±160 kn ±220 kn Electrically measurable overload +1.2 F pressure to 1.5 F tensile Supply voltage U sup 8 to 10 V regulated voltage (no direct supply out of vehicle power (battery)) or 5 ±0.5 V Supply current I sup < 100 ma at 8 to 10 V; < 50 ma at 5 ±0.5 V Signal voltage U sig 25% to 75% U sup at 8 to 10 V; 15% to 85% U sup at 5 ±0.5 V Load resistance 10 kω Characteristic 1 2 Hysteresis See drawing Operating temperature range 5 C to +85 C Storage temperature range 40 C to +125 C (permanent); +10 C (max. 2 h) Type of protection with installed mating connector Vibration load Mating connector Electromagnetic compatibility EMC according to ISO 11452-5 2002-04 1 MHz to 2 GHz AMP DEUTSCH IP67 and IP69K IP66K 24 g -pin connector with single-wire seal 150 V/m ±0.5% U sup Characteristics Characteristic 1 (load range up to 50 kn or 5 V versions) Characteristic 2 (load range up to 60 kn) U sig Hysteresis, typical ±0.01 U sup Usig Hysteresis, typical ±0.005 U sup Characteristic with decreasing loading Characteristic with decreasing loading 100% 100% F tensile F tensile 100% F pressure 100% F pressure Characteristic with increasing loading Characteristic with increasing loading Bosch Rexroth AG, RE 95170/07.2017

Dimensions [mm] Draft sensor KMB series 0 Dimensions 5 Dimensions 10 +1 1 158 +1.5 10 +0.5 0.5 9 +0.8 0.8 +0.5 24 0.5 15 +0.4 +0.2 8.2 +0.5 0.5 Protection cap for mating connector 74± 0 Ø7 0.17 0.42 Ø5 L*±20 AMP Measurement zone DEUTSCH * see ordering code for cable length Connector AMP Pin assignment DEUTSCH Pin assignment 1 25 0.5 2 2 1 15 0.5 1 Ground GND 2 Signal voltage U sig Supply voltage U sup 1 Supply voltage U sup 2 Signal voltage U sig Ground GND The reversed polarity of U sup with ground accrues a short-circuit. The short-circuit protection may not exceed 1A. A current limitation in the is necessary. Mating connector R917000515 1) Designation Number Ordering code Housing 1 1928402579 2) Protection cap 1 128070022 2) Contacts 92999 ) Single-wire seal (wire size: 0.5 to 1.0 mm 2 ) 828 905-1 ) for FLK cable type 828 904-1 ) for FLKr, FLX cable Mating connector 1) Designation Ordering code Plug connector DEUTSCH DT 04-P 4) Wedge-lock DEUTSCH W P 4) Contacts DEUTSCH 0460-202-16141 4) 1) The mating connector is not included in the scope of supply. 2) Available from Bosch ) Available from AMP 4) Available from DEUTSCH RE 95170/07.2017, Bosch Rexroth AG

6 KMB series 0 Draft sensor Cable versions Cable versions Cable without protective sleeve 8.2 ±0.5 L±20 Protection cap for mating connector Ø15±0.5 Ø5 74± Cable with spiral protective sleeve 8.2 ±0.5 L±20 Protection cap for mating connector Ø15±0.5 Ø14±1 Ø5 74± Cable with metal protective sleeve 8.2 ±0.5 L±20 1.5 800±20 Fitting (WAF 1), rotating Ø5 Protection cap for mating connector Ø15±0.5 Ø10 A-thread, Pg 7 (WAF 15) Metal protective sleeve, movable 74± Cable with plastic protective sleeve 8.2 ±0.5 L±20 Protection cap for mating connector Ø15±0.5 Ø10 Ø5 74± Bosch Rexroth AG, RE 95170/07.2017

Draft sensor KMB series 0 Installation instructions 7 Installation instructions B-B B See installation drawing Y 80 04 22 to avoid measuring uncertainties Defined draft application, e.g., ball bushing Floating mount in radial direction with key plate B Manufacturer confirmation of KMB MTTF d -value The component was developed and series produced before both the currently applicable Directive on Machinery 2006/42/EC and the harmonized EN ISO 1849 standard applied. According to ISO 1849-2: 2008-09, the product meets the basic safety principles and the well-tried safety principles to the extent that they apply to the product. The KMB component is not a safety component in the sense of Directive on Machinery 2006/42/EC and has not been developed according to ISO 1849:2008. The MTTFd value was determined in accordance with ISO 1849-1:2008-12, Appendix D, Parts Count Method, and the specified temperature profiles below. The application and operating conditions are documented in data sheet RD95170. The MTTFd value for the KMB is 11 years. Operating time share [%] 0 10 0 0 0 40 0 50 0 60 0 70 0 80 100 85 0 100 Ambient temperature of control unit [ C] RE 95170/07.2017, Bosch Rexroth AG

8 KMB series 0 Draft sensor Installation instructions Assessment of Safety Principles List of the safety principles that must be to take into account in the higher-level. Chapter Basic safety principles (SP) D.1.6 D.1.7 D.1.12 Application of the principle of energy separation (GS-BGIA-M1: Off-load current principle, spring, return spring) Suppression of voltage peaks Protection from unexpected restarting after restoring the energy supply Remarks Technology Area of use Implemented in product A safe condition is achieved by separating all important equipment from the energy source, e.g. by using a normally closed (NC) contact for inputs (contact and position switches) and a normally open (NO) contact for relays [see also EN 292-2:1991 (ISO/TR 12100-2:1992),.7.1]. There can be exceptions in some cases, e.g. if a failure of the electrical supply represents an additional hazard. Timedelaying functions may be necessary to ensure that a safe status of the is achieved [see EN 60204-1:1997 (IEC 60204-1:1997), 9.2.2]. A set up for suppressing voltage peaks (an RC element, a diode or a varistor) must be used parallel to the applied load but not parallel to the contacts. NOTE: A diode increases the switching off time. Avoiding unexpected start-up, e.g. after restoring the energy supply [see EN 292-2:1991 (ISO/TR 12100-2:1992),.7.2, EN 107 (ISO 14118), EN 60204-1 (IEC 60204-1)]. Special applications, e.g. maintaining the energy for clamping devices or securing a position, need to be considered separately. Electrical Electrical Electrical If the energy supply is disconnected, the sensor does not deliver any more values. There is no substantial capacity, which means that shut-off is below 1 ms. The higher-level must detect a cable break. A fault in the electronic that leads to a plausible value is not detected. Measurement of radiated emissions was not carried out. The result is below the values that the standards require. The operating parameters defined inside TKU must be ensured by the higher-level. Assuming that the sensor is supplied with a supply voltage according to the specification, a ratiometric output signal is present. The higher-level (control unit) must always ensure that the sensor signal is interpreted correctly. Bosch Rexroth AG, RE 95170/07.2017

Draft sensor KMB series 0 Installation instructions 9 Chapter Well-tried safety principles (SP) A.2.2 D..5 D..8 Using components with a defined failure behavior Limiting electrical parameters Status orientation in the case of failures Remarks Technology Area of use Implemented in product The most frequent failure behavior of a component is known in advance and is always the same, see EN 292-2:1991 (ISO/TR 12100-2:1992),.7.4. Limiting of the voltage, current, energy or frequencies to avoid an unsafe status, e.g. by torque limitation, offset/time-limited running and reduced speed. If possible, all equipment/circuits should enter a safe condition or be safe to operate. D.2.9 Multiplication of parts Reduction in the impact of defects by using several parts of the same type; in this connection, for example, a fault that occurs on one spring (of many) does not lead to a dangerous condition. D..9 Directed failure If it is possible to implement, components or s should be used whose types of failure are known in advance [see EN 292-2:1991 (ISO/TR 12100-.2:1992),.7.4]. Mechanical Electrical Electrical Mechanical Electrical If the pin is operated outside the specification, this can result in a zero shift or breakage. The higher-level must detect this and evaluate it. The upper and lower limit of the supply voltage are defined. Outside of these limits, the sensor reaches a clamping voltage that the higher-level must interpret. In general, the higher-level must be able to interpret the ratiometric signal. From 4.2 V to 18 V, the sensor works on a ratiometric basis. Above and below the voltage limit, the output voltage becomes zero and is detected by the control unit as a cable break. From 4.2 V to 18 V, the sensor works on a ratiometric basis. Above and below the voltage limit, the output voltage becomes zero and is detected by the control unit as a cable break. If the pin is operated outside the mechanical specification, this can result in a zero shift or breakage. The higher-level must detect faulty operating status conditions of the sensor and appropriate remedies must be defined and implemented. Irrelevant for components, since the only mechanical part of the pin itself is known (application-specifically) and the status orientation is known in the case of failures, see D..8. From 4.2 V to 18 V, the sensor works on a ratiometric basis. Above and below the voltage limit, the output voltage becomes zero and is detected by the control unit as a cable break. The higher-level must detect faulty operating status conditions of the sensor and appropriate remedies must be defined and implemented. RE 95170/07.2017, Bosch Rexroth AG

10 KMB series 0 Draft sensor Safety Instructions Safety Instructions General Instructions Before finalizing your design, request a binding installation drawing. The proposed circuits do not imply any technical liability for the on the part of Bosch Rexroth. It is not permissible to open the sensor or to modify or repair the sensor. Modifications or repairs to the wiring could result in dangerous malfunctions. Connections in the hydraulic may only be opened in depressurized state. The sensor may only be assembled/disassembled in depressurized and deenergized state. System developments, installation and commissioning of electronic s for controlling hydraulic drives must only be carried out by trained and experienced specialists who are sufficiently familiar with both the components used and with the complete. While commissioning the sensor, the machine may pose unforeseen dangers. Before commissioning the, you must therefore ensure that the vehicle and the hydraulic are in a safe condition. Make sure that nobody is in the machine s danger zone. No defective or incorrectly functioning components may be used. If the sensor should fail or demonstrate faulty operation, it must be replaced. Despite every care being taken when compiling this document, it is not possible to take into account all feasible applications. If instructions for your specific application are missing, you can contact Bosch Rexroth. Sensors do not fall under the scope of EMC-RL 2004/108/EC or 2014/0/EU. A declaration of conformity and the CE marking for individually sold sensors is not required, since the sensors are only sold to machine manufacturers (OEM) or to companies with the necessary expertise (i.e. certified Bosch Rexroth partners or companies with trained and qualified service personnel). Furthermore, the responsibility of the above mentioned companies for machine EMC testing remains unaffected in principle. The use of sensors by private users is not permissible, since these users do not typically have the required level of expertise. Notes on the installation location and position Do not install the sensor close to parts that generate considerable heat (e.g. exhaust). Lines are to be routed with sufficient distance from hot or moving vehicle parts. A sufficiently large distance to radio s must be maintained. The connector of the sensor is to be unplugged during electrical welding and painting operations. Cables/wires must be sealed individually to prevent water from entering the device. Notes on transport and storage Please inspect the device for any damages which may have occurred during transport. If there are obvious signs of damage, please immediately inform the transport company and Bosch Rexroth. If it is dropped, the sensor must not be used any longer as invisible damage could have a negative impact on reliability. Notes on wiring and circuitry Lines to the sensors must be designed as short as possible and be shielded. The shielding must be connected to the electronics on one side or to the machine or vehicle ground via a low-resistance connection. The sensor should only be plugged and unplugged when it is in a de-energized state. The sensor lines are sensitive to radiation interference. For this reason, the following measures should be taken when operating the sensor: Sensor lines should be attached as far away as possible from large electric machines. If the signal requirements are satisfied, it is possible to extend the sensor cable. Lines from the sensor to the electronics must not be routed close to other power-conducting lines in the machine or vehicle. The wiring harness should be fixated mechanically in the area in which the sensor is installed (spacing < 150 mm). The wiring harness should be fixated so that in-phase excitation with the sensor occurs (e.g. at the sensor mounting points). If possible, lines should be routed in the vehicle interior. If the lines are routed outside the vehicle, make sure that they are securely fixed. Bosch Rexroth AG, RE 95170/07.2017

Draft sensor KMB series 0 Safety Instructions 11 Lines must not be kinked or twisted, must not rub against edges and must not be routed through sharpedged ducts without protection. Intended use The sensor is designed for use in mobile working machines provided no limitations/restrictions are made to certain application areas in this data sheet. Operation of the sensor must generally occur within the operating ranges specified and released in this data sheet, particularly with regard to voltage, temperature, vibration, shock and other described environmental influences. Use outside of the specified and released boundary conditions may result in danger to life and/or cause damage to components which could result in consequential damage to the mobile working machine. More detailed information Further information about the sensor can be found at www.boschrexroth.com/mobile-electronics. The sensor must be disposed according the national regulations of your country. Improper use Any use of the sensor other than that described in chapter Intended use is considered to be improper. Use in explosive areas is not permissible. Damages which result from improper use and/or from unauthorized, interference in the component not described in this data sheet render all warranty and liability claims with respect to the manufacturer void. Use in safety-related functions The customer is responsible for performing a risk analysis of the mobile working machine and determining the possible safety-related functions. In safety-related applications, the customer is responsible for taking suitable measures for ensuring safety (sensor redundancy, plausibility check, emergency switch, etc.). Product data that is necessary to assess the safety of the machine can be provided on request or are listed in this data sheet. RE 95170/07.2017, Bosch Rexroth AG

12 KMB series 0 Draft sensor Bosch Rexroth AG Mobile Applications Robert-Bosch-Straße 2 71701 Schwieberdingen, Germany Tel. +49 9 52 40 50 60 info.bodas@boschrexroth.de www.boschrexroth.com Bosch Rexroth AG 2017. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights. The data specified within only serves to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. Bosch Rexroth AG, RE 95170/07.2017