BACnet Protocol Implementation Conformance Statement (PICS)

Similar documents
DINGO-Stack, BACnet and BACnet/WS PICS

Swegon GOLD BACnet PICS Version E BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

ANNEX A - PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (NORMATIVE) (This annex is part of this Standard and is required for its use.

Modular Series BACnet Protocol Implementation Conformance (PIC) Statement A6V Building Technologies

BACnet protocol implementation conformance

PXC Compact Unitary Equipment Controller BACnet Protocol Implementation Conformance Statement

BACnet protocol implementation conformance statement (PICS)

BACnet protocol implementation conformance statement (PICS)

TRIDIUM NIAGARA AX 3.8

Universalgateway. BACnet Protocol Implementation Conformance Statement. Version: 2016, October 17

EC-Net AX /NIAGARA AX Framework 3.5 BACNET PICS

BACnet IP Enabled InFusion Controller Bacnet-IP-IC BACnet Protocol Implementation Conformance Statement

EC-Net AX 3.6 BACnet PICS

Climatix VVS11 BACnet Protocol Implementation Conformance Statement (PICS) Basic documentation

BCM-ETH BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

Additional BACnet Interoperability Building Blocks Supported (Annex K):

Functional Specifications Gateway

BACnet P.I.C.S. For RDT900 configurable controllers. Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement (PICS) Product Discription V1.0

IntesisBox BACnet KNX (V6)

Wireless Pneumatic Thermostat BACnet Gateway PICS. Document No rev 01

BACnet Protocol Implementation Conformance Statement

Protocol Implementation Conformance Statement (PICS)

Vitogate 300. BACnet Protocol Implementation Conformance Statement (PICS)

Manual Protocol Implementation Conformance Statement (PICS) Version

BACnet Protocol. Implementation Conformance Statement. Version: 2.0 Date:

EC-Net AX 3.6 BACnet PICS

Integration Specification Sheet

Distech Controls Application Specific Controllers PICS

BACnet PCD7.R560 BACnet PCD7.R562

BACnet Protocol Implementation Conformance Statement

Omni BEMS Controllers PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (PICS)

BACnet Protocol Implementation Conformance Statement

Protocol Implementation Conformance Statement (PICS)

BACnet Protocol Implementation Conformance Statement (PICS) MULTICAL 62/601/602/6L2/6M2/801

! BACnet Operator Workstation (B-OWS)! BACnet Advanced Operator Workstation (B-AWS)! BACnet Operator Display (B-OD)

BACnet Protocol Implementation Conformance Statement

Desigo V5 BACnet Protocol Implementation Conformance Statement (PICS) Basic documentation

BACnet Protocol Implementation Conformance Statement

Protocol Implementation Conformance Statement (PICS)

Desigo V5.1 BACnet Protocol Implementation Conformance Statement (PICS) Basic documentation

DS-RP-A AE-N-I-B DM-DCC-B DS-RP-B AE-ACK-B DM-PT-A DS-RPM-B AE-ASUM-B DM-PT-B DS-WP-A AE-INFO-B DM-TS-A DS-WP-B DM-DDB-B DM-UTC-B

MULTICAL 403 MULTICAL 603

Product Implementation Conformance Statement bcx1-r

BACnet Protocol Implementation Conformance Statement

Product Implementation Conformance Statement bcx-4040

Product Implementation Conformance Statement bcx1-cr

ENC/JACE/NXT G3 Release 3.6 Network Controllers

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

Input/Output Module (IOM) Series Protocol Implementation Conformance Statement

IntesisBox BACnet Server KNX TP-1. User Manual r1.0 eng

BACnet Protocol Implementation Conformance Statement

BACnet/IP Advanced Application Field Equipment Controllers Protocol Implementation Conformance Statement

BTL Listed March 2013

Advanced Application Field Equipment Controllers Protocol Implementation Conformance Statement Code No. LIT Issued December 5, 2014

IntesisBox BACnet Server Modbus RTU Master and Modbus TCP Client

Synergy Network Controller

IntesisBox BACnet Server M-Bus Meters

BACnet Protocol Implementation Conformance Statement Automated Logic Corporation LGR25, LGR250, LGR1000

Desigo V6.0 BACnet Protocol Implementation Conformance Statement (PICS) Basic documentation

ESAC ebacgw SNMP. Date: Mar 08,2009. Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3. Product Description:

BACnet RIB June 24, 2016

Terminal Equipment Controller (TEC) Protocol Implementation Conformance Statement

Application Program Description

BACnet RIB Jan

Zoning System TEC2647Z-2 and TEC2647Z-2+PIR Zone Controllers Protocol Implementation Conformance Statement

MicroTech II Multiple Air Handler Controller

Neutrino-GLT Server BACnet TM Protocol Implementation Conformance Statement (PICS) Version 3

BACnet Gateway for VRF System UTY-VBGX

IntesisBox BACnet MS/TP Server & BACnet IP Server Daikin Air Conditioning

Keywords: PcVue, BACnet, PICS. Last Revision Date: 30 March 2011

Climatix BACnet Protocol Implementation Conformance Statement (PICS)

HMS-1655 BACnet MS/TP Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement OEMPrtl Pro

homelynk/spacelynk BACnet Protocol Implementation Conformance Statement

IntesisBox BACnet IP Server Notifier ID3000 and Morley DXc fire panel series. User Manual r1.1 eng

Desigo PXC3 and DXR2 Automation Stations BACnet Protocol Implementation Conformance Statement (PICS) Basic documentation

IntesisBox BACnet MS/TP Server & BACnet IP Server Daikin Air Conditioning

Building Operation. Vendor ID 10

IntesisBox BACnet MS/TP Server & BACnet IP Server Mitusbishi Heavy Industries Air Conditioning

Delta Control Unit (DCU) 3.30 BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

entelibus CPU Engine (eb-eng) Firmware

MatrixBBC. Protocol Implementation Conformance Statement (PICS) Product Description: BACnet Standardized Device Profile:

DDC4200 BACnet TM Protocol Implementation Conformance Statement (PICS) Version 1

Delta Controller Engine (DCE) Firmware

PXC Compact Series on BACnet/IP

Sales and Engineering Data Sheet ED

BACnet Protocol Implementation Conformance Statement Automated Logic G5RE

BACnet RIB July 1, 2014

BACnet Protocol Implementation Conformance Statement

SUBMITTAL MACH-Pro1 DIMENSIONS

Public Review Draft. ASHRAE Standard

NS Series CO 2 Network Zone Sensors Protocol Implementation Conformance Statement

Delta ORCAview Date: August 5, 2009 Vendor Name: Delta Controls Inc. Product Name:

Field Equipment Controllers Protocol Implementation Conformance Statement

Date: Vendor Name: Product Name: Product Model Number: Applications Software Version: Firmware Revision: BACnet Protocol Revision:

Transcription:

BACnet Protocol Implementation Conformance Statement (PICS) Version..0

2 General Copyright 200 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 D-32423 Minden Phone: +49 (0) 57/8 87 0 Fax: +49 (0) 57/8 87 69 E-Mail: info@wago.com Web: http://www.wago.com/ Technical Support Phone: +49 (0) 57/8 87 7 77 Fax: +49 (0) 57/8 87 87 77 E-Mail: tcba@wago.com Every conceivable measure has been taken to ensure the correctness and completeness of this document. However, as errors can never be fully excluded, we always appreciate any information or suggestions for improving the documentation. E-Mail: documentation@wago.com

Content 3 Content BACnet Protocol Implementation Conformance Statement... 4. Product Description...4.2 List all BACnet Interoperability Building Blocks Supported (Annex K) 5.2. Data-Sharing BIBBs... 5.2.2 Alarm and Event BIBBs...5.2.3 Scheduling BIBBs... 5.2.4 Trending BIBBs... 5.2.5 Device Management BIBBs...6.3 Segmentation Capability...6.4 Standard Object Types Supported...7.4. Accumulator...7.4.2 Analog Input...8.4.3 Analog Output... 9.4.4 Analog Value... 0.4.5 Averaging....4.6 Binary Input...2.4.7 Binary Output...3.4.8 Binary Value...4.4.9 Calendar... 5.4.0 Command... 6.4. Device... 7.4.2 File... 9.4.3 Group...20.4.4 Life Safety Point...2.4.5 Life Safety Zone...22.4.6 Multi State Value...23.4.7 tification Class...24.4.8 Pulse Converter...25.4.9 Schedule... 26.4.20 Trend Log... 27.5 Data Link Layer Options... 28.6 Networking Options...28.7 Character Sets Supported...28

4 BACnet Protocol Implementation Conformance Statement PICS BACnet Protocol Implementation Conformance Statement Date: 2.05.200 Vendor Name: WAGO Kontakttechnik GmbH & Co. KG Product Name: BACnet/IP Controller Product Model Number: 750-830 Applications Software Version: --- Firmware evision: 0.04.27(03) BACnet Protocol evision: ev. 6. Product Description The BACnet Controller provides access to BACnet-networks acting either as a BACnet-Client or as a BACnet-Server. BACnet Standardized Device Profile (Annex L): BACnet Operator Workstation (B-OWS) BACnet Building Controller (B-BC) BACnet Advanced Application Controller (B-AAC) BACnet Application Specific Controller (B-ASC) BACnet Smart Sensor (B-SS) BACnet Smart Actuator (B-SA)

BACnet Protocol Implementation Conformance Statement PICS 5.2 List all BACnet Interoperability Building Blocks Supported (Annex K).2. Data-Sharing BIBBs Data Sharing ead-property-a Data Sharing ead-property-b Data Sharing ead-property-multiple-a Data Sharing ead-property-multiple-b Data Sharing Write-Property-A Data Sharing Write-Property-B Data Sharing Write-Property-Multiple-B Data Sharing COV-A Data Sharing COV-B Data Sharing COVP-B Data Sharing COV-Unsolicited-A Data Sharing COV-Unsolicited-B DS-P-A DS-P-B DS-PM-A DS-PM-B DS-WP-A DS-WP-B DS-WPM-B DS-COV-A DS-COV-B DS-COVP-B DS-COVU-A DS-COVU-B.2.2 Alarm and Event BIBBs Alarm and Event tification-internal Alarm and Event Acknowledge-B Alarm and Event Information-B Alarm and Event Alarm Summary-B Alarm and Event Enrollment Summary-B AE-N-I-B AE-ACK-B AE-INFO-B AE-ASUM-B AE-ESUM-B.2.3 Scheduling BIBBs Scheduling-Internal-B Scheduling-External-B SCHED-I-B SCHED-E-B.2.4 Trending BIBBs Trending Viewing and Modifying Trends Internal-B Trending Viewing and Modifying Trends External-B Trending Automated Trend etrieval-b T-VMT-I-B T-VMT-E-B T-AT-B

6 BACnet Protocol Implementation Conformance Statement PICS.2.5 Device Management BIBBs Device Management Dynamic Device Binding-A Device Management Dynamic Device Binding-B Device Management Dynamic Object Binding-B Device Management DeviceCommunicationControl-B Device Management TimeSynchronization- B Device Management UTCTimeSynchronization- B Device Management einitializedevice-b Device Management Backup and estore-b Device Management List Manipulation-B DM-DDB-A DM-DDB-B DM-DOB-B DM-DCC-B DM-TS-B DM-UTC-B DM-D-B DM-B-B DM-LM-B.3 Segmentation Capability Segmented requests supported Window Size 6 Segmented responses supported Window Size 6

BACnet Protocol Implementation Conformance Statement PICS 7.4 Standard Object Types Supported.4. Accumulator ne Tab. -: Accumulator Present_Value Unsigned 50 Device_Type CharacterString O W ISO/ANSI: 0 50 Status_Flags BACnetStatusFlags Event_State BACnetEventState eliability BACneteliability O W Out_Of_Service BOOLEAN W Scale BACnetScale W Units BACnetEngineeringUnits W Prescale BACnetPrescale O Max_Pres_Value Unsigned Value_Change_Time BACnetDateTime O 2 Value_Before_Change Unsigned O 2,3 Value_Set Unsigned O 2,3 W Logging_ecord BACnetAccumulatorecord O - Logging_Object BACnetObjectIdentifier O - Pulse_ate Unsigned O,4 High_Limit Unsigned O 4 W Low_Limit Unsigned O 4 W Limit_Monitoring_Interval Unsigned O 4 W tification_class Unsigned O 4 W Time_Delay Unsigned O 4 W Limit_Enable BACnetLimitEnable O 4 W Event_Enable BACnetEventTransitionBits O 4 W Acked_Transitions BACnetEventTransitionBits O 4 tify_type BACnettifyType O 4 Event_Time_Stamps BACnetAAY[3] of O 4 BACnetTimeStamp 2 3 4 This property is required to be writable when Out_Of_Service is TUE. These properties are required if either Value_Before_Change or Value_Set is writable. Either Value_Before_Change or Value_Set may be writable, but not both. These properties are required if the object supports intrinsic reporting.

8 BACnet Protocol Implementation Conformance Statement PICS.4.2 Analog Input ne Tab. -2: Analog Input Present_Value EAL 50 Device_Type CharacterString O W ISO/ANSI: 0 50 Status_Flags BACnetStatusFlags Event_State BACnetEventState eliability BACneteliability O W if OoS = true Out_Of_Service BOOLEAN W Update_Interval Unsigned O Units BACnetEngineeringUnits W Min_Pres_Value EAL O Max_Pres_Value EAL O esolution EAL O COV_Increment EAL O 2 W Time_Delay Unsigned O 3 W tification_class Unsigned O 3 W High_Limit EAL O 3 W Low_Limit EAL O 3 W Deadband EAL O 3 W Limit_Enable BACnetLimitEnable O 3 W Event_Enable BACnetEventTransitionBits O 3 W Acked_Transitions BACnetEventTransitionBits O 3 tify_type BACnettifyType O 3 W Event_Time_Stamps BACnetAAY[3] of O 3 BACnetTimeStamp 2 3 This property is required to be writable when Out_Of_Service is TUE. This property is required if the object supports COV reporting. These properties are required if the object supports intrinsic reporting.

BACnet Protocol Implementation Conformance Statement PICS 9.4.3 Analog Output ne Tab. -3: Analog Output Present_Value EAL W W 50 Device_Type CharacterString O W ISO/ANSI: 0 50 Status_Flags BACnetStatusFlags Event_State BACnetEventState eliability BACneteliability O W if OoS = true Out_Of_Service BOOLEAN W Units BACnetEngineeringUnits W Min_Pres_Value EAL O Max_Pres_Value EAL O esolution EAL O Priority_Array BACnetPriorityArray elinquish_default EAL W COV_Increment EAL O W Time_Delay Unsigned O 2 W tification_class Unsigned O 2 W High_Limit EAL O 2 W Low_Limit EAL O 2 W Deadband EAL O 2 W Limit_Enable BACnetLimitEnable O 2 W Event_Enable BACnetEventTransitionBits O 2 W Acked_Transitions BACnetEventTransitionBits O 2 tify_type BACnettifyType O 2 W Event_Time_Stamps BACnetAAY[3] of O 2 BACnetTimeStamp 2 This property is required if the object supports COV reporting. These properties are required if the object supports intrinsic reporting.

0 BACnet Protocol Implementation Conformance Statement PICS.4.4 Analog Value ne Tab. -4: Analog Value Present_Value EAL 4 W 50 Status_Flags BACnetStatusFlags Event_State BACnetEventState eliability BACneteliability O W Out_Of_Service BOOLEAN W Units BACnetEngineeringUnits W Priority_Array BACnetPriorityArray O elinquish_default EAL O W COV_Increment EAL O 2 W Time_Delay Unsigned O 3 W tification_class Unsigned O 3 W High_Limit EAL O 3 W Low_Limit EAL O 3 W Deadband EAL O 3 W Limit_Enable BACnetLimitEnable O 3 W Event_Enable BACnetEventTransitionBits O 3 W Acked_Transitions BACnetEventTransitionBits O 3 tify_type BACnettifyType O 3 W Event_Time_Stamps BACnetAAY[3] of O 3 BACnetTimeStamp 2 3 4 If Present_Value is commandable, then both of these properties shall be present. This property is required if the object supports COV reporting. These properties are required if the object supports intrinsic reporting. If Present_Value is commandable, then it is required to be writable. This property is required to be writable when Out_Of_Service is TUE.

BACnet Protocol Implementation Conformance Statement PICS.4.5 Averaging ne Tab. -5: Averaging Minimum_Value EAL Minimum_Value_ BACnetDateTime O W Timestamp Average_Value EAL Variance_Value EAL O Maximum_Value EAL Maximum_Value_ BACnetDateTime O W Timestamp 50 Attempted_Samples Unsigned W W Valid_Samples Unsigned Object_Property_eference BACnetDeviceObject- W Propertyeference Window_Interval Unsigned W W Window_Samples Unsigned W W If any of these properties are written to using BACnet services, then all of the buffer samples shall become invalid, 'Attempted_Samples' shall become zero, 'Valid_Samples' shall become zero, 'Minimum_Value' shall become INF, 'Average_Value' shall become NaN and 'Maximum_Value' shall become -INF.

2 BACnet Protocol Implementation Conformance Statement PICS.4.6 Binary Input ne Tab. -6: Binary Input Present_Value BACnetBinaryPV 50 Device_Type CharacterString O W ISO/ANSI: 0 50 Status_Flags BACnetStatusFlags Event_State BACnetEventState eliability BACneteliability O W if OoS = true Out_Of_Service BOOLEAN W Polarity BACnetPolarity W Inactive_Text CharacterString O 2 W ISO/ANSI: 0 50 Active_Text CharacterString O 2 W ISO/ANSI: 0 50 Change_Of_State_Time BACnetDateTime O 3 Change_Of_State_Count Unsigned O 3 W only 0 (zero) allowed for Write; count at least up to 65535 Time_Of_State_Count_eset BACnetDateTime O 3 Elapsed_Active_Time Unsigned32 O 4 W only 0 (zero) allowed for Write Time_Of_Active_Time_eset BACnetDateTime O 4 Time_Delay Unsigned O 5 W tification_class Unsigned O 5 W Alarm_Value BACnetBinaryPV O 5 W Event_Enable BACnetEventTransitionBits O 5 W Acked_Transitions BACnetEventTransitionBits O 5 tify_type BACnettifyType O 5 W Event_Time_Stamps BACnetAAY[3] of O 5 BACnetTimeStamp 2 3 4 5 This property is required to be writable when Out_Of_Service is TUE. If one of the optional properties Inactive_Text or Active_Text is present, then both of these properties shall be present. If one of the optional properties Change_Of_State_Time, Change_Of_State_Count, or Time_Of_State_Count_eset is present, then all of these properties shall be present. If one of the optional properties Elapsed_Active_Time or Time_Of_Active_Time_eset is present, then both of these properties shall be present. These properties are required if the object supports intrinsic reporting.

BACnet Protocol Implementation Conformance Statement PICS 3.4.7 Binary Output ne Tab. -7: Binary Output Present_Value BACnetBinaryPV W W 50 Device_Type CharacterString O W ISO/ANSI: 0 50 Status_Flags BACnetStatusFlags Event_State BACnetEventState eliability BACneteliability O Out_Of_Service BOOLEAN W Polarity BACnetPolarity W Inactive_Text CharacterString O W ISO/ANSI: 0 50 Active_Text CharacterString O W ISO/ANSI: 0 50 Change_Of_State_Time BACnetDateTime O 2 Change_Of_State_Count Unsigned O 2 W only 0 (zero) allowed for Write; count at least up to 65535 Time_Of_State_Count_ BACnetDateTime O 2 eset Elapsed_Active_Time Unsigned32 O 3 W only 0 (zero) allowed for Write Time_Of_Active_Time_ BACnetDateTime O 3 eset Minimum_Off_Time Unsigned32 O W Minimum_On_Time Unsigned32 O W Priority_Array BACnetPriorityArray elinquish_default BACnetBinaryPV W Time_Delay Unsigned O 4 W tification_class Unsigned O 4 W Feedback_Value BACnetBinaryPV O 4 W Event_Enable BACnetEventTransitionBits O 4 W Acked_Transitions BACnetEventTransitionBits O 4 tify_type BACnettifyType O 4 W Event_Time_Stamps BACnetAAY[3] of O 4 BACnetTimeStamp 2 3 4 If one of the optional properties Inactive_Text or Active_Text is present, then both of these properties shall be present. If one of the optional properties Change_Of_State_Time, Change_Of_State_Count, or Time_Of_State_Count_eset is present, then all of these properties shall be present. If one of the optional properties Elapsed_Active_Time or Time_Of_Active_Time_eset is present, then both of these properties shall be present. These properties are required if the object supports intrinsic reporting.

4 BACnet Protocol Implementation Conformance Statement PICS.4.8 Binary Value ne Tab. -8: Binary Value If option. or W Property ange Present_Value BACnetBinaryPV W 50 Status_Flags BACnetStatusFlags Event_State BACnetEventState eliability BACneteliability O W Out_Of_Service BOOLEAN W Inactive_Text CharacterString O 2 W ISO/ANSI: 0 50 Active_Text CharacterString O 2 W ISO/ANSI: 0 50 Change_Of_State_Time BACnetDateTime O 3 Change_Of_State_Count Unsigned O 3 W only 0 (zero) allowed for Write; count at least up to 65535 Time_Of_State_Count_eset BACnetDateTime O 3 Elapsed_Active_Time Unsigned32 O 4 W only 0 (zero) allowed for Write Time_Of_Active_Time_eset BACnetDateTime O 4 Minimum_Off_Time Unsigned32 O W Minimum_On_Time Unsigned32 O W Priority_Array BACnetPriorityArray O 5 elinquish_default BACnetBinaryPV O 5 W Time_Delay Unsigned O 6 W tification_class Unsigned O 6 W Alarm_Value BACnetBinaryPV O 6 W Event_Enable BACnetEventTransitionBits O 6 W Acked_Transitions BACnetEventTransitionBits O 6 tify_type BACnettifyType O 6 W Event_Time_Stamps BACnetAAY[3] of O 6 BACnetTimeStamp 2 3 4 5 6 If Present_Value is commandable, then it is required to be writable. This property is required to be writable when Out_Of_Service is TUE. If one of the optional properties Inactive_Text or Active_Text is present, then both of these properties shall be present. If one of the optional properties Change_Of_State_Time, Change_Of_State_Count, or Time_Of_State_Count_eset is present, then all of these properties shall be present. If one of the optional properties Elapsed_Active_Time or Time_Of_Active_Time_eset is present, then both of these properties shall be present. If Present_Value is commandable, then both of these properties shall be present. These properties are required if the object supports intrinsic reporting.

BACnet Protocol Implementation Conformance Statement PICS 5.4.9 Calendar ne Tab. -9: Calendar 50 Present_Value BOOLEAN Date_List List of BACnetCalendarEntry W

6 BACnet Protocol Implementation Conformance Statement PICS.4.0 Command ne Tab. -0: Command 50 Present_Value Unsigned W W In_Process BOOLEAN All_Writes_Successful BOOLEAN Action BACnetAAY[N] of BACnetActionList W Action_Text BACnetAAY[N] of CharacterString O W ISO/ANSI: 0 50

BACnet Protocol Implementation Conformance Statement PICS 7.4. Device ne Tab. -: Device WAGO Property ange System_Status BACnetDeviceStatus Vendor_Name CharacterString Vendor_Identifier Unsigned6 Model_Name CharacterString Firmware_evision CharacterString Application_Software_Version CharacterString Location CharacterString O W ISO/ANSI: 0 50 50 Protocol_Version Unsigned Protocol_evision Unsigned Protocol_Services_Supported BACnetServicesSupported Protocol_Object_Types_Supported BACnetObjectTypesSupported Object_List BACnetAAY[N]of BACnetObjectIdentifier Max_APDU_Length_Accepted Unsigned Segmentation_Supported BACnetSegmentation Max_Segments_Accepted Unsigned O VT_Classes_Supported List of BACnetVTClass O 2 - Active_VT_Sessions List of BACnetVTSession O 2 - Local_Time Time O 3,4 Local_Date Date O 3,4 UTC_Offset INTEGE O 4 W Daylight_Savings_Status BOOLEAN O 4 W APDU_Segment_Timeout Unsigned O W APDU_Timeout Unsigned Number_Of_APDU_etries Unsigned W List_Of_Session_Keys List of BACnetSessionKey O - Time_Synchronization_ecipients List of BACnetecipient O 5 - Max_Master Unsigned(..27) O 6 - Max_Info_Frames Unsigned O 6 - Device_Address_Binding List of BACnetAddressBinding Database_evision Unsigned Configuration_Files BACnetAAY[N] of O 7 BACnetObjectIdentifier Last_estore_Time BACnetTimeStamp O 7 Backup_Failure_Timeout Unsigned6 O 8 W Active_COV_Subscriptions List of BACnetCOVSubscription O 9 Slave_Proxy_Enable BACnetArray[N] of BOOLEAN O 0 - Manual_Slave_Address_Binding List of BACnetAddressBinding O 0 - Auto_Slave_Discovery BACnetArray[N] of BOOLEAN O - Slave_Address_Binding List of BACnetAddressBinding O 2 -

8 BACnet Protocol Implementation Conformance Statement PICS 2 3 4 5 6 7 8 9 0 2 equired if segmentation of any kind is supported. If one of the properties VT_Classes_Supported or Active_VT_Sessions is present, then both of these properties shall be present. Both properties are required if support for VT Services is indicated in the PICS. If the device supports the execution of the TimeSynchronization service, then these properties shall be present. If the device supports the execution of the UTCTimeSynchronization service, then these properties shall be present. equired if PICS indicates that this device is a Time Master. If present, this property shall be writable. These properties are required if the device is an MS/TP master node. These properties are required if the device supports the backup and restore procedures. This property must be present and writable if the device supports the backup and restore procedures. This property is required if the device supports execution of either the SubscribeCOV or SubscribeCOVProperty service. This property shall be present and writable if the device is capable of being a Slave-Proxy device. This property shall be present if the device is capable of being a Slave-Proxy device that implements automatic discovery of slaves. This property shall be present if the device is capable of being a Slave-Proxy device.

BACnet Protocol Implementation Conformance Statement PICS 9.4.2 File ne Tab. -2: File 50 File_Type CharacterString File_Size Unsigned W Modification_Date BACnetDateTime Archive BOOLEAN W W ead_only BOOLEAN W File_Access_Method BACnetFileAccessMethod 2 ecord_count Unsigned O 2-2 If the file size can be changed by writing to the file, and File_Access_Method is STEAM_ACCESS, then this property shall be writable. This property shall be present only if File_Access_Method is ECOD_ACCESS. If the number of records can be changed by writing to the file, then this property shall be writable.

20 BACnet Protocol Implementation Conformance Statement PICS.4.3 Group ne Tab. -3: Group 50 List_Of_Group_Members List of eadaccessspecification W Present_Value List of eadaccessesult

BACnet Protocol Implementation Conformance Statement PICS 2.4.4 Life Safety Point ne Tab. -4: Life Safety Point Present_Value BACnetLifeSafetyState Tracking_Value BACnetLifeSafetyState O 50 Device_Type CharacterString O W ISO/ANSI: 0 50 Status_Flags BACnetStatusFlags Event_State BACnetEventState eliability BACneteliability W Out_Of_Service BOOLEAN W Mode BACnetLifeSafetyMode W W Accepted_Modes List of BACnetLifeSafetyMode W Time_Delay Unsigned O 2 W tification_class Unsigned O 2 W Life_Safety_Alarm_Values List of BACnetLifeSafetyState O 2 W Alarm_Values List of BACnetLifeSafetyState O 2 W Fault_Values List of BACnetLifeSafetyState O 2 W Event_Enable BACnetEventTransitionBits O 2 W Acked_Transitions BACnetEventTransitionBits O 2 tify_type BACnettifyType O 2 W Event_Time_Stamps BACnetAAY [3] of O 2 BACnetTimeStamp Silenced BACnetSilencedState Operation_Expected BACnetLifeSafetyOperation Maintenance_equired BACnetMaintenance O W Setting Unsigned8 O W Direct_eading EAL O 3 W Units BACnetEngineeringUnits O 3 W Member_Of List of O W BACnetDeviceObjecteference 2 3 These properties are required to be writable when Out_Of_Service is TUE. These properties are required if the object supports intrinsic alarming. If either of these properties is present, then both must be present.

22 BACnet Protocol Implementation Conformance Statement PICS.4.5 Life Safety Zone ne Tab. -5: Life Safety Zone Present_Value BACnetLifeSafetyState Tracking_Value BACnetLifeSafetyState O 50 Device_Type CharacterString O W ISO/ANSI: 0 50 Status_Flags BACnetStatusFlags Event_State BACnetEventState eliability BACneteliability W Out_Of_Service BOOLEAN W Mode BACnetLifeSafetyMode W W Accepted_Modes List of BACnetLifeSafetyMode W Time_Delay Unsigned O 2 W tification_class Unsigned O 2 W Life_Safety_Alarm_Values List of BACnetLifeSafetyState O 2 W Alarm_Values List of BACnetLifeSafetyState O 2 W Fault_Values List of BACnetLifeSafetyState O 2 W Event_Enable BACnetEventTransitionBits O 2 W Acked_Transitions BACnetEventTransitionBits O 2 tify_type BACnettifyType O 2 W Event_Time_Stamps BACnetAAY [3] of O 2 BACnetTimeStamp Silenced BACnetSilencedState Operation_Expected BACnetLifeSafetyOperation Maintenance_equired BOOLEAN O W Zone_Members List of W BACnetDeviceObjecteference Member_Of List of O W BACnetDeviceObjecteference 2 These properties are required to be writable when Out_Of_Service is TUE. These properties are required if the object supports intrinsic alarming.

BACnet Protocol Implementation Conformance Statement PICS 23.4.6 Multi State Value ne Tab. -6: Multi State Value Present_Value Unsigned W 50 Status_Flags BACnetStatusFlags Event_State BACnetEventState eliability BACneteliability O 2 W no-fault-detected not allowed when Present_Value = Fault_Value Out_Of_Service BOOLEAN W Number_Of_States Unsigned State_Text BACnetAAY[N] of CharacterString Priority_Array BACnetPriorityArray O 3 elinquish_default Unsigned O 3 W Time_Delay Unsigned O 4 W tification_class Unsigned O 4 W Alarm_Values List of Unsigned O 4 W Fault_Values List of Unsigned O 4 W Event_Enable BACnetEventTransitionBits O 4 W Acked_Transitions BACnetEventTransitionBits O 4 tify_type BACnettifyType O 4 W Event_Time_Stamps BACnetAAY[3] of O 4 BACnetTimeStamp O W ISO/ANSI: 0 50 per entry 2 3 4 If Present_Value is commandable, then it is required to also be writable. This property is required to be writable when Out_Of_Service is TUE. This property shall be required if Fault_Values is present. If Present_Value is commandable, then both of these properties shall be present. These properties are required if the object supports intrinsic reporting.

24 BACnet Protocol Implementation Conformance Statement PICS.4.7 tification Class ne Tab. -7: tification Class 50 tification_class Unsigned Priority BACnetAAY[3] of Unsigned W Ack_equired BACnetEventTransitionBits W ecipient_list List of BACnetDestination W

BACnet Protocol Implementation Conformance Statement PICS 25.4.8 Pulse Converter ne Tab. -8: Pulse Converter 50 Present_Value EAL Input_eference BACnetObjectPropertyeference O W Status_Flags BACnetStatusFlags Event_State BACnetEventState eliability BACneteliability O W Out_Of_Service BOOLEAN W Units BACnetEngineeringUnits W Scale_Factor EAL W Adjust_Value EAL W W Count Unsigned Update_Time BACnetDateTime Count_Change_Time BACnetDateTime 2 Count_Before_Change Unsigned 2 COV_Increment EAL O 3 W COV_Period Unsigned O 3 W tification_class Unsigned O 4 W Time_Delay Unsigned O 4 W High_Limit EAL O 4 W Low_Limit EAL O 4 W Deadband EAL O 4 W Limit_Enable BACnetLimitEnable O 4 W Event_Enable BACnetEventTransitionBits O 4 W Acked_Transitions BACnetEventTransitionBits O 4 tify_type BACnettifyType O 4 W Event_Time_Stamps BACnetAAY[3] of O 4 BACnetTimeStamp 2 3 4 This property is required to be writable when Out_Of_Service is TUE. These properties are required if Count_Before_Change is writable. These properties are required if the object supports COV reporting. These properties are required if the object supports intrinsic reporting.

26 BACnet Protocol Implementation Conformance Statement PICS.4.9 Schedule ne Tab. -9: Schedule WAGO Property ange Present_Value Any Description CharacterString O W ISO/ANSI: 0 DBCS, UCS- 2, JIS: 50 Effective_Period BACnetDateange W Weekly_Schedule BACnetAAY[7]of BACnetDailySchedule O W Exception_Schedule BACnetAAY[N]of BACnetSpecialEvent O W Schedule_Default Any W List_Of_Object_ List of BACnetDeviceObjectPropertyeference W Property_eferences Priority_For_Writing Unsigned(..6) W Status_Flags BACnetStatusFlags eliability BACneteliability Out_Of_Service BOOLEAN W At least one of these properties is required.

BACnet Protocol Implementation Conformance Statement PICS 27.4.20 Trend Log ne Tab. -20: Trend Log If option. or W Property ange 50 Log_Enable BOOLEAN W W Start_Time BACnetDateTime O,2 W Stop_Time BACnetDateTime O,2 W Log_DeviceObjectProperty BACnetDeviceObjectPropert O W yeference Log_Interval Unsigned O,2 W COV_esubscription_Interval Unsigned O W Client_COV_Increment BACnetClientCOV O W Stop_When_Full BOOLEAN W Buffer_Size Unsigned32 W Log_Buffer List of BACnetLogecord ecord_count Unsigned32 W W Total_ecord_Count Unsigned32 tification_threshold Unsigned32 O 3 W ecords_since_tification Unsigned32 O 3 Last_tify_ecord Unsigned32 O 3 Event_State BACnetEventState tification_class Unsigned O 3 W Event_Enable BACnetEventTransitionBits O 3 W Acked_Transitions BACnetEventTransitionBits O 3 tify_type BACnettifyType O 3 W Event_Time_Stamps BACnetAAY[3] of O 3 BACnetTimeStamp 2 3 These properties are required to be present if the monitored property is a BACnet property. If present, these properties are required to be writable. These properties are required to be present if the object supports intrinsic reporting.

28 BACnet Protocol Implementation Conformance Statement PICS.5 Data Link Layer Options BACnet IP, (Annex J) BACnet IP, (Annex J), Foreign Device ISO 8802-3, Ethernet (Clause 7) ASTM 878., 2.5 Mb. ACNET (Clause 8) ASTM 878., S-485 ACNET (Clause 8) baud rate(s): MS/TP master (Clause 9), baud rate(s): MS/TP slave (Clause 9), baud rate(s): Point-To-Point, EIA 232 (Clause 0), baud rate(s): max. EIA 232 Point-To-Point, modem, (Clause 0), baud rate(s): max. modem LonTalk, (Clause ), medium: Other:.6 Networking Options outer, Clause 6 - List all routing configurations: Annex H, BACnet Tunneling outer over IP BACnet Broadcast Management Device (BBMD) Does the BBMD support registrations by Foreign Devices? (BTD, FDT summarized number limitation: max. 6) Yes.7 Character Sets Supported Indicating support for multiple character sets does not imply that they can all be supported simultaneously. ANSI X3.4 IBM? /Microsoft? DBCS ISO 8859- ISO 0646 (UCS-2) ISO 0646 (UCS-4) JIS C 6226 If this product is a communication gateway, describe the types of non-bacnet equipment/networks(s) that the gateway supports.

BACnet Protocol Implementation Conformance Statement PICS 29

WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 D-32385 Minden Hansastraße 27 D-32423 Minden Phone: 05 7/8 87 0 Fax: 05 7/8 87 69 E-Mail: info@wago.com Web: http://www.wago.com