Level monitoring system NT 2000 / 3500 series Selection list

Similar documents
Level monitoring system NT 3500 Technical information / Instruction manual

Nivotec 1. Table of contents. Level monitoring system NT 3500 Technical information / Instruction manual. Page

Level monitoring system NT 4500 Technical information / Instruction manual

Continuous level measuring system NB 3000 Selection list

Signal conditioning instruments VEGASCAN 693. Product Information

AC5160 SiPass integrated controller kit

Displays Transducers. Displays and transducers

MIC-2 Multi-instrument DATA SHEET

BMS Steam Station Solutions

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

with Backlight Graphic LCD Screen

Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG

VEGAMET 381 VEGAMET 624 VEGAMET 625

Product type designation. Display. Control elements

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016


Remote monitoring and display solutions

K44 Code lock. Technical manual

Efficient. Innovative. Sustainable.

Display. Control elements

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Operating Instructions VEGAMET 381

CHP GAS MONITOR GDR 1404

QUICK START. ATEQ F620 Version 1.0. Reference: MR-28300A-U. (Photo no contractual)

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Portable Data LOGGING SYSTEMS. for Professionals

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

SmartAir Master. The intelligent compressed air management system Developed by Compair to save your customers money

HART Density Gauge Datasheet

CHP GAS MONITOR GDR 1404

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Simplified information where and how you want it.

DS 500 Intelligent chart recorder for compressed air and gases

RealFlow Digital Oil Flow Meter for paper machines

MIC-2 MKII, Multi-instrument DATA SHEET

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

AUTARKIC PROCESS MANAGEMENT

DATA-COMMUNICATION-MODULE DATACONT DC 6000

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Condition monitoring systems. Vibration monitoring systems

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

VEGA SOFTWARE AND DISPLAY INSTRUMENTS

LUMIOS MkIII Luminance Photometer for Tunnels

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

MAS Monitoring system for pumps. Reliable operation Low LCC Easy handling

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Counting On Your Process Preset Counters

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Terminals. Spectrometer Probes. i::scan Ionselective. Probes. Physical Probes. Terminals. Software System. Configuration. Monitoring Stations

JUMO mtron T Measuring, Control, and Automation System

EGW1-IA3-MB User s Manual

horizontal and vertical bargraph channel display of a group with units and scalabled plus standardized measured values

Diode Array Process NIR Instrument. Reliable, Accurate, Real-time

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

Gas Controller System DGC-06

Presented By. NicolScales.com Contact Us

Continuous level measurement Ultrasonic controllers

MX 62 CONTROLLER. Certifications. Better detection. Better protection. Monitoring system for gas and flame detection

Micro Instruments price list All pricing excludes 15%

Millenium II +: general characteristics

General information. Display. Control elements

Online data sheet. C4C-EB10530A10000 detec SAFETY LIGHT CURTAINS

EXOcompact. Third generation freely programmable controllers

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

page A.0240 Full_Product_catalogue_ BM.indb 110

THYRO-S THYRO-A THYRO-AX THYRO-PX

SIMOCODE 3UF Motor Management and Control Devices

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Clear Benefits of the KRAL Electronic.

CMC-99 (RS ) multichannel CONTROLLERS data recorders

Endress Hauser CUM 740. Measuring Transmitter for Turbidity and Solids Content ISO The Power of Know How

Neon pr. ph/ ORP measurement. Applications. Description

InCos-P Pressure sensor 20 Pa Pa

Dupline Fieldbus Components

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

PQM - Power Quality Monitoring

Product type designation. Display. Control elements

Terminals. Spectrometer Probes. i::scan Ionselective. Probes. Physical Probes. Terminals. Software System. Configuration. Monitoring Stations

Compressed air management systems SIGMA AIR MANAGER SIGMA AIR MANAGER 16/8 F1 F2 F3 F4 F5 F6 next.generation

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

CLA-VAL Control Panel

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

Multifunction Transducer MT440

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Operating Instructions for Digital Thermometers. Model: DTM

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

mark150s mark150/485s DDC controllers Summary

Installation and configuration. WebAccess and its modules for ECL Comfort 200 / 300

GRASSO SYSTEM CONTROL

AC5160 Controller. Fire & Security Products. SiPass integrated

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Transcription:

Table of contents Page Overview 2 -------------------------------------------------------------------------------------------------------- NT 2000 4 Level monitoring via control cabinet visualisation -------------------------------------------------------------------------------------------------------- 6 Level monitoring via web server visualisation (via Ethernet) Subject to change. All dimensions in mm (inches). All prices in Euro, excluding VAT. Valid: From 01.04.2017 until 31.03.2018, unless otherwise agreed. By publishing this selection list all other lists become invalid. We assume no liability for typing errors. All prices are EXW Betzigau, excluding packaging costs. Different variations to those specified are possible. Please contact our technical consultants. NT 2000 / 3500 pl010417 page 1

Overview Silo plant with continuous level measurement technology, level limit sensors and shut off valves in the filling pipes. Modbus RTU 4-20mA/HART or countig pulses from UWT-lead systems Digital level limit signals 4-20mA Digital level limit signals NT 2000 Ethernet Remote data enquiry page 2 pl010417 NT 2000 / 3500

Overview NT 2000 System Control cabinet system for display and monitoring of contents with digital instrumentation and LEDs for level limits. Control cabinet system for display and monitoring of contents and levels. The self contained system works with visualisation software on a web server. Number of silos Max. 10 (more are possible on request) Max. 50 (more are possible on request) Software Not available Licence free visualisation software in HTML form. Password-protected access on alle Ethernet PCs. Control cabinet Standard equipment Standard equipment or pre-mounted on cap rail Input signal Analogue inputs (4-20mA) - Modbus RTU of Nivobob 3000 - Analogue inputs (4-20mA) - Counting inputs (from electromechanical lead systems) - Profibus available on request Alarm signal Silo- full Display in the control cabinet door Remote data request Optional - Full signal available as a flashing light with buzzer - Digital display for silo level - LED for full and empty signal Not available Optional - Full signal available as a buzzer - Touch panel 10", 4 or 15" - Digital display for silo level - LED for full and empty signal Via Internet (VPN tunnel) or GSM Modem Trend data Not available The recording of the level data is made internal as a ring buffer. These can be exported and processed as.csv. Optional - Silo Mounting - Display Silo "full" via LED and flashing light with buzzer - Reset by push button Optional - Silo Mounting equipment - Display Silo "full" via LED and flashing light with buzzer - Reset by push button Pinch valve control Not available Optional - Automatic in case of silo full detection - Release via key switch / PC / Touchpanel Interfaces Not available - Modbus RTU - Ethernet - Profibus on request Technical data Dimensions Material, degree of protection, ambient temperature Supply voltage Supply power Depending on the number of silos Control cabinet: steel plate, IP54, 0..50 C : steel plate, IP65, -25..+60 C Terminal box NT50: steel plate, IP65, -25..+60 C 230V 50Hz Depending on the number of silos and connected sensors NT 2000 / 3500 pl010417 page 3

NT 2000 Features - Fill level indication on an LED display in percentage, height, volume or weight - Simple and easy handling of the various display elements - Evaluation of the analogue 4-20 ma signals of any sensors - Fill control via full alarm signal - Separate truck module for comfortable monitoring during silo filling NT 2000 control cabinet The NT 2000 offers the level indication modules and monitoring functions integrated in a control cabinet. The fill level is displayed via the Nivotec NT 4900 digital display, the level limits via full and empty LEDs. 4-20 ma signals are evaluated. It is possible to integrate an alarm signal with a buzzer which signals when the silo becomes full during filling. The buzzer can be mounted directly on the silo. The NT 2000 is a complete system which also provides the supply voltage for the sensors. It is delivered with project specific electrical plans. UWT electro mechanical lead system: measurement start and indication "upper stop position" For use with one silo. Mounting directly on the silo frame. Indication of empty and full level with LEDs. Reset of alarm "Silo full". Example: with full/empty LEDs, push button for reset of alarm "Silo full" page 4 pl010417 NT 2000 / 3500

NT 2000 Nivotec NT 2000 pos. 1 Basic configuration Price including monitoring of the first silo Extra price for each additional silo monitoring NT 2000... pos. 2 pos. 3 pos. 4 Measurement technology With use of electro mechanical lead systems: supply voltage lead system 230V AC A 4-20mA (active or passive)... B 4-20mA from NB 3000/4000 incl. start button for measurement, display "upper stop position" and "failure"... Integration of level limit sensors LED display in control cabinet Level limit sensor supply / signal output as follows: 0 without... 1 Full level sensor (230V AC / floating)... 2 Full and empty level sensor (230V AC / floating)... 3 Full level sensor (24V DC / floating or PNP)... 4 Full and empty level sensor (24V DC / floating or PNP)... Alarm "silo full" 1x buzzer, 1x reset button Alarm "silo full" (for outside mounting): with Pos.5 0 buzzer delivery in loose parts (reset button inside a surface mounting housing) with Pos.5 L buzzer delivery in loose parts (reset button mounted in the truck module) 0 without... A with... pos. 5 (only with pos.4 A) Delivery of one separate truck module per silo 0 without... L with... pos. 7 Number of vessels / silos (max. 10, more are possible on request) Basic configuration Position NT 2000 0 Order code 1 2 3 4 5 6 7 NT 2000 / 3500 pl010417 page 5

Features - Fill level visualisation via HTTP-web server - Visualisation via standard Internet browser software on all Ethernet PCs - Password protected - Worldwide remote enquiry of the level password protected - on request - Software operation addtional via a touch panel in the control cabinet or via fill level LEDs - Data in percentage, height, volume or weight - Trend display, data storage, export via.csv - Evaluation of the analogue 4-20 ma signals of any sensors, as well as Modbus RTU of the UWT-systems - Different input signals within the same system is possible - Fill control via full alarm signals and shut off valves - Separate truck module for safe and comfortable monitoring during silo filling control cabinet The heart of the is a web server module, which the visualisation software uses. All fill level control and display functions can be operated via the visualisation on a PC or a Touch panel with backlight. An Ethernet interface ensures that the visualisation can be simultaneously operated from all PCs which are connected to the interface. Access is password protected. Additionally the control cabinet can be equipped with operating and display elements. Either the 10.4" or 15" touch panel or the digital level display with full and empty LEDs can be choosen. The electromechanical lead system can be started by the visualisation or by a push button. A buzzer for alarm "silo full" can be mounted directly on the silo. Control for pinch valves to stop the filling is available. The NT 3500 is a complete system which also provides the supply voltage for the sensors. The system is delivered with project specific electrical plans. Selection pos.5 B: Display, LED Selection pos.5 D,E: Display on Touchpanel Functionality of alarm"silo full" and control of the pinch valves: 1. The filling (opening of the pinch valve) is enabled eihter via the hose coupling when connecting the filing hose, via a key switch on the cabinet or on the truck module or via PC/Touch panel. 2. In case of an alarm "silo full" the pinch valve closes, the LED "silo full" and the buzzer is switched on, the reset button is blinking. After reset of the alarm the pinch valve opens for ca. 5 min to enable the expulsion of the filling pipe, then it is closed again. Independend from this control the pinch valve can be opened or closed by an authorized user at any time. - One module for a defined number of silos (depending on the project) - Mounting directly at the silo frame - Display silo full/empty and pinch valve status with LEDs - Reset of alarm "silo full" - Key switch for pinch valve control Example: page 6 pl010417 NT 2000 / 3500

Nivotec Price for the first silo Extra price for each additional silo... Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 5 Visualisation system - HTTP web server incl. 24V DC power supply (used also for supply of the level limit sensors) A Completely wired in a control cabinet max. 25 silos/vessels... B No control cabinet, pre-wired on a top hat rail max. 25 silos/vessels... C Completely wired in a control cabinet max. 50 silos/vessels... D No control cabinet, pre-wired on a top hat rail max. 50 silos/vessels... Input signals of level sensors With use of NB 3000/ 4000: supply voltage of NB 3000/4000= 230V AC 1 Modbus RTU (NB 3000/ 4000)... 2 4-20mA active (NB 3000/ 4000)... 3 Counting pulses (NB 3000)... 4 4-20mA / 2-wire (NivoRadar NR 3000)... Integration of level limit switches incl. alarm "silo full" 1x buzzer, 1x reset button alarm "silo full" (for outside mounting): with Pos.4 0 buzzer delivery in loose parts, reset button inside a surface mounting housing with Pos.4 1 buzzer delivery in loose parts, reset button mounted in the truck module Level limit sensor supply / signal output as follows: 0 without... A Full level sensor (230V AC / floating) wired on NB / Modbus... B Full level sensor (24V DC / floating or PNP)... C Full and empty level sensor (24V DC / floating or PNP)... D Full level sensor (230V AC / floating)... E Full and empty level sensor (230V AC / floating)... 0 without... 1 with... Visualisation at control cabinet only with pos.1 A, C 0 without... B Digital level display and LED full or full/empty (only with pos.2. 4)... C Digital level display and LED full or full/empty (only with pos.2. 2) for NB 3000/4000, incl. start button, display "upper stop position" and "failure"... D 10.4" 800x600 Touch panel... E 15" 1024x768 Touch panel... Pos. 6 Pinch valve control (only with pos.4 1) Shut off in case of silo full detection, possibility of expulsion of the filing pipes Display and operating elements located on the truck module 0 without... 1 Filling enabled via mouse click on the PC and on Touch panel... 2 Filling enable by key switch on the truck module... 3 Filling enable by key switch on the cabinet... Pos. 7/8 Number of vessels / silos (max. 25/50) Pos. 9 Remote enquiry A via Internet (with furnished VPN tunnel)... B via GSM Modem... on request Pos. 10 Hose coupling switch 0 not present... 1 connected to NB 3000/4000 (terminal 24/26)... 2 connected to Nivotec... Basic configuration Position 1 2 3 4 5 6 7/8 9 10 Order code NT 2000 / 3500 pl010417 page 7

Further options (on request) Ethernet gateway Radio-relay system Connection with only one Ethernet line between silo areas which are far located from each other. Connection by radio communication between silo areas which are far located from each other (max. 1800m). page 8 pl010417 NT 2000 / 3500