Fiberoptic G.703 Codir - IEEE C37.94 converter, Technical manual. Technical Manual 90_20_0101_r2.doc

Similar documents
10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

EOS-6000 Series Optical A/B Switch User Manual DC Version

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Junos WebApp Secure 5.0 Hardware Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS. KC-300DM Series. Installation Guide

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

Accessories / 7XV5461

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

KFC-200. Installation Guide

Dell SC460 Expansion Enclosure Getting Started Guide

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

User Guide. Westermo Teleindustri AB 2004 REV.A SDW Industrial Ethernet 5-port Switch.

SCv360 Expansion Enclosure

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

DXF-200 DVI/HDMI Optical Extension System

Installation Job Aid for Ethernet Routing Switch 3600 Series

Industrial 3-Port Fast Ethernet Media Converter Switches

F271XA Fiber-Optic Telephone Modem Technical Manual

Installation Notes for the Cisco TwinGig and OneX Converter Modules

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Rugged MediaConverter

2260B-RMK-Series Rack Mount Kit

Fiber optic converter audio and CAN TA OPERATION MANUAL

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL

FL MC 2000E (SM40) LC

Installation Instructions

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Dell OptiPlex All-in-One. Stand Installation Guide

Accessories / 7XV5662

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

Single Channel Video Insert Unit with Bi-directional Data Channel for a Dual Redundant fibre ring

10/100 Ethernet Fiber Link Card System

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

PIX 520. PIX 520 Product Overview CHAPTER

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

Cisco ONS CL Shelf Assembly Hardware

TRC-190 User s Manual

Symantec S500 Network Interface Card Options and Installation

MC 11 EB-2 Power supply cabinet with external bus, AC version

Manual Fiber Optic Interfaces

Installation Instructions

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

Quick Start Installation Guide

Symantec S500 Network Interface Card Options and Installation

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

Quick Start Guide. C-100 Series Switches

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Installation Instructions

2 Wire Digital Phone Fiber Link Card System

Disclaimer. Note that the Midspan is designed for indoor use only.

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM

Metro-Optical Transport Access Nodes

POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

Hardened Web-Smart High Power PoE Ethernet Switch

TOA INTERCOM SYSTEM TELEPHONE LINE INTERFACE

USER MANUAL MODEL 570-R8/570-R R8/580-R Base-T (CAT-5) Surge Protectors

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

VCL-TP, Teleprotection Equipment

SER-4485-SI-M USER S MANUAL

Prisma II Platform. Optoelectronics

Dolphin DXE410 Expansion Chassis

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

TippingPoint Zero Power High Availability Installation Guide

Features and Benefits. Certifications

Installation Job Aid for VSP 4850GTS

crio PN Installation Instructions V0.2/ COMSOFT

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide

PHOENIX CONTACT - 10/2009

Replacing the Power Supply

F271XAD Fiber-Optic Telephone Modem with RS485 Data Technical Manual

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Model 7705 Control Module

High Power over Ethernet Midspans PD Port Model PD Port Model

HDMI Optical Extender USER MANUAL VE882 / VE892

Installation Guide Controller Series E130/E230/E430

PS3108C. 8-Port Web Smart GbE PoE+ Switch QUICK INSTALLATION GUIDE

Transcription:

Fiberoptic G.703 Codir - IEEE C37.94 converter, 21-216 Technical manual Technical Manual 90_20_0101_r2.doc

About this manual About the contents of this manual The information in this document may be changed at any time without notice.. Table of Contents About the contents of this manual Table of Contents i i Product 21-216 consists of: 4 Serial number. 6 Version and revision history. 1 Revision history for product: 1 Revision history for this document. 1 Functional 2 IEEE C37.94 2 G.703 Codirectional interface - Codir 2 Features 3 Fiberoptic and data transfer protocol 3 Power Supply. 3 Physical size 3 Environmental conditions 3 Unpacking. 4 Front Panel. 6 Back Panel. 6 Fiber Optic Port. 7 G.703 64kbit/s Codir Port. 7 Clock configuration switch. 8 Functional earth/ground. 8 Strappingarea. 9 Opening the 21-216. (If necessary!). 9 Channel configuration 11 Clock synchronization configuration 12 Ground select jumper 13 Reassemble. 13 Power on. 14 LED-status. 14 Clock synchronization configuration 15 CE - mark 16

Version and revision history. Revision history for product: Revision P1 (Prototype 1). Valid for serial number: FS-02434 and FS-02435 (2004-03-18). Revision R1. Product released for serial production. 2004-08-13. Revision R2. Internal strappingarea function is added with a rotary switch on frontpanel. Valid from serial number: 55032252 (2004-12-17). Revision history for this document. Revision AK0. 2004-03-17, AnNy, document created. Revision AK1. 2004-05-05, AnNy, description of LED-indications, and more. Revision R1. 2004-08-08, AnNy, Product released for serial production. Pinning of Codir-port corrected. Revision R2. 2004-12-16, AnNy, Product revision R2 released for serial production. Rotary switch for configuration. Document properties. Last saved: 2004-12-17 14:35 Filename: Technical Manual 90_20_0101_r2.doc Author. Created by Anders Nyström. Last saved by Anders Nyström. 1

General description Functional The 21-216, Fiberoptic G.703 Codir IEEE C37.94 converter is intended to extend distance and galvanic isolate the teleprotection equipment for substations connection to multiplexers. IEEE C37.94 The standard IEEE C37.94-2002, IEEE Standard for N times 64 Kilobit per Second Optical Fiber Interfaces between Teleprotection and Multiplexer Equipment describes a fiberoptic intra-substation communication links between teleprotection equipment and multiplexers. G.703 Codirectional interface - Codir The standard G.703 64kbit/s codirectional interface describes a galvanic interface commonly used by teleprotection equipment for connection to multiplexers. 2

Features Fiberoptic and data transfer protocol Data speed Optical data Wavelength Fiber optical connector Optical System budget 2.048Mbit/s 820nm ST 13dB with multimode fiber, (62.5/125 um) 9dB with multimode fiber, (50/125 um) Typical distance 2km (6dB systemmargin for 62.5/125 and 3dB margin for 50/125). Power Supply. 48V DC to 250V DC, + 20% 110V AC to 230V AC, 50Hz, + 20%. AC connector IEC 320, 3 pin. Power consumption <20W. Physical size The unit is intended to be mounted in a 19 rack. By adjusting, the rack mount brackets, the unit can also be mounted on a wall or similar. Height Width Depth Weight 45 mm 483 mm (380 mm without rack mount brackets). 173 mm (from front to back, connectors excluded). 3 kg Environmental conditions Operating temperature Storage temperature -25 to +55 o C -40 to +85 o C 3

Unpacking. Check that all packing material has no damage. If damages are discovered on packing material, contact your shipping company, before unpacking. The delivered product consists of several parts. Check that all part are present according to list, and have no damage. Product 21-216 consists of: Quantity Part number Description 1 1 21-216 Fiberoptic G.703 Codir IEEE C37.94 converter (Part number includes all parts in this list). 2 2 60-00-5387 Rack Mounting Bracket 3 8 50-65-1673 Screw, MFX-H M3x5 FZB 4 1 50-65-0106 Power cord, 1.8m European connector. 5 4 50-65-5030 Rubber feet 6 1 90-20-0101 This manual 21-216, (Part number includes all parts in list above). 21-216 revision 2, (Part number includes all parts in list above). 4

Power cord. 2 Rack mounting brackets 8 screws for rack mounting brackets 4 Rubber feet 5

Installation. Serial number. The products serial number is the best way for Fibersystem to identify the product. If the serial number is not noted on your delivery notes, please add the serial number to your own product documentation. This will be useful at future contact with Fibersystem. Front Panel. Power Supply IEC 320 connector Functional ground Fiber Optic Ports G.703 port 21-216 revision 1. Status LEDs Clock configuration rotary switch 21-216 revision 2 Back Panel. There are no connections or indications on the back panel. 6

Fiber Optic Port. The fiber optic connector is of ST type. Confirm that the attenuation of the fiber optic cable, including splices and patch cables, doesn t exceed the system budget. Don t forget to add a safety margin. Minimum safety margin is 3dB. Make sure that the local fiber optic transmitter, marked Tx, is connected to the remote units fiber optic receiver, marked Rx. And local Rx shall be connected to remote Tx. G.703 64kbit/s Codir Port. Shield (Metal house) Pin 1 Pin 8 Pinning of Codir port: RJ45 pin Name Direction 1 Tx+ (TIP-out) From 21-216 to multiplexer 2 Tx- (RING-out) From 21-216 to multiplexer 4 Rx+ (TIP-in) From multiplexer to 21-216 5 Rx- (RING-in) From multiplexer to 21-216 Metalhouse Shield Cables shield must be connected Use a cable with twisted pairs and a high quality shield. Only foil shielding is not enough. Rx+ and Rx- should form one twisted pair - Tx+ and Tx- another twisted pair. A Cat5 S/FTP-cable, (Shielded/Foil Twisted Pair) used for example in Ethernet communication is a good cable. The outer shield is a braided mesh around the cable. In addition every twisted pair has a foil-shielding. 7

If a S/FTP patchcable for Ethernet is used, be aware that a cross-connected cable has only the pairs on pin 1-2 and 3-6 cross-connected, the two remaining pairs are not cross-connected. Clock configuration switch. From 21-216 revision 2 and later, a rotary switch is added to the front panel, to ease installation and testing. Functional earth/ground. To the left of the IEC 320 power supply connector, a reference ground/earth screw is available. Protective ground shall be connected to the IEC 320 power supply connector. Chassis ground and internal signalground, can be connected together with an internal jumper. 8

Configuration Strappingarea. The 21-216 can be used for several applications and situations. The different applications need to be configured. For product revision 1, this is done with a strapping area inside the unit has to be configured. From 21-216 product revision 2, some configuration also can be done with a 16 position rotary switch on the front panel. WARNING High Voltage! WARNING: When you remove the cover you will expose live parts and accessible terminals, which can cause death. Disconnect mains cable before opening the 21-216. Opening the 21-216. (If necessary!). At the backpanel 4 screws has to be removed. Slide the top lid backwards. Front 9

Lift lid in back. If necessary, disconnect protective earth cable. Strapping area Strappingarea P2 Ground jumper 10

CAUTION ESD sensitive parts! Electrostatic charges, and their resulting discharges (ESD - electrostatic discharge), present severe risks to the life of electronic equipment in general, and to semiconductor components in particular. Use conductive wrist straps or similar protective aids, to prevent any risk for electrostatic discharges. On the strapping area P2, there are 10 jumper positions. 0 9. Channel configuration Position 0 3, selects the IEEE C37.94-channel for data, (fiber). There are 12 channels available. The four jumpers form a hexadecimal number corresponding to the channel. Jumper 0 Jumper 1 Jumper 2 Jumper 3 Selected channel LSB MSB Empty Empty Empty Empty 0 Not used! Jumper Empty Empty Empty 1 Empty Jumper Empty Empty 2 Jumper Jumper Empty Empty 3 Empty Empty Jumper Empty 4 Jumper Empty Jumper Empty 5 Empty Jumper Jumper Empty 6 Jumper Jumper Jumper Empty 7 Empty Empty Empty Jumper 8 Jumper Empty Empty Jumper 9 Empty Jumper Empty Jumper 10 ( 0A Hex ) Jumper Jumper Empty Jumper 11 ( 0B Hex ) Empty Empty Jumper Jumper 12 ( 0C Hex ) Jumper Empty Jumper Jumper 13 Not used! Empty Jumper Jumper Jumper 14 Not used! Jumper Jumper Jumper Jumper 15 Not used! 11

The jumper positions correspond to the LED-area CHANNEL on the frontpanel. Jumpers 4, 5 and 6 are not used for configuration. (Can be used for spare jumpers). Clock synchronization configuration Jumpers 7, 8 and 9 configures the clock selection. A jumper on position 9 selects clock from codir interface. A jumper on position 8 selects clock from fiber interface. A jumper on position 7 inverts the clock received from fiber.. In some applications it is necessary to adjust the phase between the received clock on fiber and the galvanic clock. This is done, by inverting the clock received from fiber. If both position 8 and 9 are left empty the internal clock in the 21-216 is selected. For 21-216 R2, (revision 2), or later also a rotary switch on the frontpanel can be used for clock synchronization configuration. The rotary switch has 16 positions, (HEX-switch). At position 0 the switch s arrow, visible through the adjusting hole, points strait down. Position Function 0 Jumpers 7,8 and 9 configure clock selections 1 Jumpers 8 and 9 configure clock source selections, inverts the clock received from fiber, (overrides setting of jumper 7). 2 Internal clock is selected, (overrides settings of jumpers 8 and 9). 3 Internal clock is selected, inverts the clock received from fiber (overrides settings of jumpers 7, 8 and 9). 4 7 Reserved for future use 8-15 Reserved for factory testing When a not used channel is selected or if both codir and fiber clock are selected, the ERR LED on the frontpanel is lit. 12

Ground select jumper P4 The strappingarea/jumper P4 selects how internal signalground and chassisground are referenced together. With a jumper between P4 s terminals chassieground and signalground are directly tied together. Without a jumper on P4 chassisground and signalground are connected together with a 100kOhm resistor in parallel with a 100nF capacitor. Reassemble. After jumper selecting, reassembling is done in the reverse order as described above. Don t forget to reconnect protective earth cables. 13

Start and usage. Power on. Connect the power cord to the 21-216 and then connect to mains. If the link doesn t work, try to cross-connect the fibers at one end. LED-status. There are 12 LED-indicators at the front panel. Power A green LED lit when power is connected to the unit. CHANNEL Four yellow LED s representing the channel chosen by jumpers at installation. The channel is calculated by adding the lit LED s. For example if LED 1 and LED 2 are lit 1+2=3 Channel 3 is chosen. This means that data to/from G.703 codir-port is sent and received on the IEEE C37.94 protocol on the fiber. The fiber protocols bits for N, named p,q,r,s in the IEEE37.94 standard are always set to N=1, (0,0,0,1). This means that 21-206 will send 1 channel and active data will be sent on channel 3. The remaining 11 channels will have idle data - all ones. 21-206 will also accept data on channel 3. RA Remote Alarm. A red LED indicating that the remote unit has encounter a fault condition and has set the Yellow Alarm bit in the IEEE C37.94 protocol. LA Local Alarm. A red LED indicating that the 21-206 has encounter a fault in the received IEEE C37.94 protocol LOS Loss Of Signal. The Yellow Alarm bit is set in the outgoing IEEE C37.94 protocol. ERR Error. A red LED indicating that the 21-216 has detected an internal error. The ERR-LED also indicates that a not allowed setting of jumpers is made. LF Link Fiber. A green LED indicating that the 21-216 receives correct IEEE C37.94 frames, (no LOS). 14

LT Link Twisted pair/g.703 codir. A green LED indicating that 21-216 receives G.703 codir 64kbit/s protocol. RxF Receive data on Fiber. A green LED indicating that 21-216 receives data in IEEE C37.94 format. RxT Receive data on Twisted pair/g.703 codir.. A green LED indicating that 21-216 receives data in G.703 codir protocol. Clock synchronization configuration Clock synchronization configuration can be done on the fly with the rotary switch on the frontpanel. Se chapter Configuration. 15

Technical support Before contacting technical support, we beg you to first read the manual once again.. If you still have problems or questions, don t hesitate to contact help desk. Please gather all relevant information, including serial number, about your installation before contacting help desk. Our technical support can be reached at: Fibersystem AB Gardsfogdevagen 18B S-16866 Bromma Sweden Telephone: +46-8-564 828 80 telefax: +46-8-28 33 50 Web: http://www.fibersystem.se/ E-mail addresses can be found on our web-site. CE - mark The product described in this manual, is designed to apply to the specifications of the EMC directive 89/336/EEC and to low voltage directive 73/23/EEC -:- 16