Time-resolved PIV measurements with CAVILUX HF diode laser

Similar documents
9.9 Coherent Structure Detection in a Backward-Facing Step Flow

Particle Image Velocimetry for Fluid Dynamics Measurements

PARTICLE IMAGE VELOCIMETRY (PIV) AND VOLUMETRIC VELOCIMETRY (V3V) SYSTEMS

Measurement Techniques. Digital Particle Image Velocimetry

Technical Specifications for High speed PIV and High speed PIV-PLIF system

Module 3: Velocity Measurement Lecture 14: Analysis of PIV data. The Lecture Contains: Flow Visualization. Test Cell Flow Quality

Particle Image Velocimetry Part - 3

Human beings are extremely interested in the observation of nature, as this was and still is of utmost importance for their survival.

Hydrodynamic Instability and Particle Image Velocimetry

Lecture # 11: Particle image velocimetry

Laser speckle based background oriented schlieren measurements in a fire backlayering front

Introduction to Modern Measurement Technology

Particle Image Velocimetry Part - 1

EXPERIMENTAL INVESTIGATION OF THE FLOW PATTERN BEHIND CYLINDER. Ing. Rut Vitkovičová, Ing. Vladislav Skála, Ing. Jan Čížek Ph.D.

The Elimination of Correlation Errors in PIV Processing

PIV and LDV measurements behind a backward facing step

Particle Velocimetry Data from COMSOL Model of Micro-channels

Hui Hu Department of Aerospace Engineering, Iowa State University Ames, Iowa 50011, U.S.A

IMAGE PROCESSING IN PIV

Application of fluorescent particles for particle tracking velocimetry in wind tunnels

Turbulencja w mikrokanale i jej wpływ na proces emulsyfikacji

Three-dimensional measurement of micro- multiphase flow using digital holographic microscopy

FLOW STRUCTURE AROUND A HORIZONTAL CYLINDER AT DIFFERENT ELEVATIONS IN SHALLOW WATER

INVESTIGATION OF FLOW BEHAVIOR PASSING OVER A CURVETURE STEP WITH AID OF PIV SYSTEM

ADVANCED MEASUREMENT TECHNIQUES IN HYDRODYNAMICS. Chittiappa Muthanna

Volumetric 3-Component Velocimetry (V3V)

Dispersion of rod-like particles in a turbulent free jet

FLOW VISUALISATION OF POLYMER MELT CONTRACTION FLOWS FOR VALIDATION OF NUMERICAL SIMULATIONS

Flow structure and air entrainment mechanism in a turbulent stationary bore

Influence of number of cameras and preprocessing for thick volume Tomographic PIV. Yuichi Fukuchi

GLASGOW 2003 INTEGRATING CFD AND EXPERIMENT

Recent Progress of NPLS Technique and Its Applications. in Measuring Supersonic Flows

APPLICATION OF WAVELET VECTOR MULTI-RESOLUTION TECHNIQUE TO PIV MEASUREMENTS

Particle Image Velocimetry on a Turbulent Jet

Flow Field of Truncated Spherical Turrets

FLOW CHARACTERISTICS AROUND A CIRCULAR CYLINDER NEAR A PLANE BOUNDARY

Measurement Principle What is VidPIV? An Overview of the VidPIV Interface Data Management

SprayMaster. Advanced Spray Analysis based on Laser Light Sheet Imaging

Direct Measurements of Reynolds Stresses and Turbulence in the Bottom Boundary Layer

Characterisation of the interaction between a boundary layer and a cavity using Digital Particle Velocimetry with Optical Flow

Characterizing drift velocity for two-phase flow using particle image velocimetry

POWERSIGHT LASER DOPPLER AND PHASE DOPPLER MEASUREMENT SYSTEMS

Pulsating flow around a stationary cylinder: An experimental study

THE INTERACTION OF A COLD ATOMISED SPRAY WITH A CIRCULAR CYLINDER

FlowMaster. Advanced PIV / PTV Systems for Quantitative Flow Field Analysis

Particle Velocimetry Data from COMSOL Model of Micro-channels

THE INFLUENCE OF ROTATING DOMAIN SIZE IN A ROTATING FRAME OF REFERENCE APPROACH FOR SIMULATION OF ROTATING IMPELLER IN A MIXING VESSEL

Doppler Global Velocimetry: A Potential Velocity Measurement Method for General Aviation Applications

Lecture # 16: Review for Final Exam

Multi-Scale Stereoscopic PIV measurements of a Jet in a Cross-Flow

SMART SOFTWARE FOR IMAGING SOLUTIONS. Complex Tasks Made Easy With DynamicStudio

VISUALIZATION OF MULTI-SCALE TURBULENT STRUCTURE IN LOBED MIXING JET USING WAVELETS

Measurements of Three-Dimensional Velocity Fields Under Breaking Waves

Advanced PIV algorithms Why and when advanced PIV algorithms?

THREE DIMENSIONALITY IN THE NEAR FIELD OF A ROUND JET

FLUOSTAR Rhodamine B- encapsulating microspheres are seeding particles optimized for Particle Image Velocimetry. Technical handbook ver.

Industrial applications of image based measurement techniques in aerodynamics: problems, progress and future needs

Measurement of Spatially Resolved Mean Velocities in a Transient Spray using Statistical Image Correlation Velocimetry

U k i E i, j,k, INTRODUCTION PHYSICS OF FLUIDS VOLUME 14, NUMBER 7 JULY 2002

Comparison between Optical Flow and Cross-Correlation Methods for Extraction of Velocity Fields from Particle Images

THREE DIMENSIONAL FLOW FIELD WITHIN A FOUR- VALVE COMBUSTION ENGINE MEASURED BY PARTICLE-IMAGE VELOCIMETRY

4th International PIV Challenge cases C and D Contents

Flow Visualization around Generic Bridge Shapes using Particle Image Velocimetry

Optimized Design of 3D Laser Triangulation Systems

FlowMaster. Advanced PIV/ PTV Systems for Quantitative Flow Field Analysis. La Vision We count on Photons

The Role of 3D Measurements in the Understanding of Turbulent Boundary Layers

PIV Uncertainty: Computational & Experimental Evaluation of Uncertainty Methods

AP* Optics Free Response Questions

SMART IMAGE PROCESSING OF FLOW VISUALIZATION

Rapid Imaging of Microstructure using Spatially Resolved Acoustic Spectroscopy

4D-PIV advances to visualize sound generation by air flows

Measurement of a laser-induced underwater shock wave by the optical-flow-based background-oriented schlieren technique

3D Dynamics of Vortex Structures in a Quasi Two-dimensional Jet

DEVELOPMENT OF A VOLUMETRIC 3D PARTICLE TRACKING VELOCIMETRY SYSTEM AND ITS APPLICATION TO MIXING IN A STIRRED TANK YE CHENG

FLOW VISUALISATION AROUND A SOLID SPHERE ON A ROUGH BED UNDER REGULAR WAVES

Development of automated ultraviolet laser beam profiling system using fluorometric technique

Performances of motion tracking enhanced Tomo-PIV on turbulent shear flows

Particle Image Velocimetry for Measuring Water Flow Velocity King Kuok Kuok, Po Chan Chiu

1.5µm lidar for helicopter blade tip vortex detection

Agricultural spray measurement by high-speed shadow imagery

ScienceDirect. Physical Modeling of Flow around the Underwater Tidal Power

Particle Image Velocimetry measurements on a birdlike airfoil

Wake Vortex Tangential Velocity Adaptive Spectral (TVAS) Algorithm for Pulsed Lidar Systems

High Resolution Planar Doppler Velocimetry Using a cw Laser

The time-resolved stereoscopic digital particle image velocimetry up to 26.7 khz

FEATURES BENEFITS 1024 x 1024 Imaging Array High resolution imaging and spectroscopy

Optical Flow Profiling Methods Used for Visualization and Evaluation of Flow Disturbances in Agricultural Pneumatic Conveyance Systems.

FlowMaster. Time-Resolved Particle Image Velocimetry Systems

Figure 1. Schematic representation of the flow past a finite-height square prism mounted normal to a ground plane and partially immersed in a flat-pla

Measurement of droplets temperature by using a global rainbow technique with a pulse laser

A three-dimensional velocimetry approach using a combination of tomographic reconstruction and triangulation for double-frame particle tracking

PI-MAX 4: 1024 EMB. Applications:

LAGRANGIAN VISUALIZATIONS and. EULERIAN DIAGNOSTICS of VORTEX BREAKDOWN

Spectral Improvement of Time Resolved PIV by FTEE in Homogeneous Isotropic Turbulence

Vortex Generator Induced Flow in a High Re Boundary Layer

Shock-Induced Instability Experiments on Gas Interfaces Featuring a Single Discrete Perturbation

Volumetric Velocimetry via Scanning Back-Projection and Least-Squares-Matching Algorithms of a Vortex Ring

LASERS FOR ANALYTICAL INSTRUMENTATION

AP Physics Problems -- Waves and Light

Experimental and Numerical Analysis of Near Wall Flow at the Intake Valve and its Influence on Large-Scale Fluctuations

Transcription:

Time-resolved PIV measurements with CAVILUX HF diode laser Author: Hannu Eloranta, Pixact Ltd 1 Introduction Particle Image Velocimetry (PIV) is a non-intrusive optical technique to measure instantaneous 2D velocity fields in fluid flows. As a state-of-the-art measurement technique in fluid dynamics R&D, PIV provides several advantages over traditional measurement techniques such as Laser Doppler and Hot Wire Anemometry. PIV is a whole-field technique which is able to capture instantaneous velocity fields over a 2D domain. This kind of data reveals flow topology, i.e. coherent flow structures such as vortices. Thus, besides providing accurate quantitative information of the flow field, PIV is also a very effective tool for studying physical phenomena contributing to the turbulence kinetic energy and other statistical measures of turbulent flows. Especially, PIV performed with high-speed imaging system creates new insight into the dynamics of turbulent motions. This paper presents time-resolved PIV experiments utilizing a high-speed camera and CAVILUX HF diode laser. CAVILUX diode lasers provide many attractive properties for PIV. Desired pulse sequences with accurate control of pulse energy and temporal spacing of consecutive pulses can be obtained easily. Furthermore, the laser unit is coupled to fiber optics, which allows a robust and flexible guidance of light to the measurement volume. The laser unit is very compact, which allows easy installation and mobility also in challenging industrial environment. 2 The measurement equipment Tracer particles are illuminated by CAVILUX HF diode laser equipped with a special light sheet generating fiber optics. The wavelength of the laser is 808 nm and the pulse energy ~0.5mJ at 20 khz. The pulse energy can be increased linearly as the pulse frequency is decreased. For example, at 1 khz pulsing rate the pulse energy can be about 10 mj. CAVILUX control unit can be programmed to produce single pulses or bursts of pulses at desired frequency and duration. However, in these measurements the laser is used as a slave, which delivers pulses with user defined duration according to external synchronization signals provided by the camera. The light sheet is created by using a fiber optic light guide with individual fibers arranged to a line at the output end. The width of the light sheet is determined by the width of the line in which the fibers are laid. Also the beam divergence affects the sheet width at the measurement plane. The thickness of the light sheet as well as the focus distance can be changed by adjusting the position of the fiber output with respect to a cylindrical lens, which is the only lens in the setup. With present design, a light sheet with a thickness of less than 1 mm is obtained at the distance of 100 mm from the lens. It is estimated that approx. 50 % of light provided by the laser is transmitted through the optics in the present design. Figure 1 presents the laser head and the light sheet optics.

Figure 1. Laser head and light sheet optics. Particle images are recorded with a Photron FASTCAM SA1.1 high-speed camera equipped with a Nikon 105mm f/# 2.8 lens and a narrow optical band-pass filter to block ambient illumination. Originally 12bit images are stored as 8bit grayscale bitmaps with 2bit shift. Details of the image recording parameters are given in Section 3. The PIV data analysis exploits a rather standard procedure. Since there is no need for image preprocessing, the recorded images are directly sent to the cross-correlation analysis. This analysis utilizes a multi-pass correlation technique with an interrogation area refinement from 64 pix to 32 pix. The data is smoothed with a 3x3 unit filter after the first pass. The final pass is not filtered. After the PIV computation, a post-processing algorithm is used to detect spurious vectors. This algorithm utilizes two criteria to detect erroneous velocity vectors. The first criterion is based on setting predefined physical limits for the allowed velocities. Actually, the pixel displacements are limited to a user defined window. The other criterion is based on the local median filtering and the comparison of each velocity vector with the median of its 3x3 neighborhood. In the case that a vector is identified as a spurious one, it is removed and the hole is filled by a Gaussian weighted interpolation from the 3x3 neighborhood.

3 Experiments Air flow from a circular slit nozzle is measured to study vortex generation in the shear layers. These vortices are expected to result in noise at high flow rates. A schematic drawing of the experimental setup is presented in Fig. 2. The PIV measurement plane is adjusted to extend over both shear layers. Measurement plane Air flow y z x Figure 2. A schematic drawing of the measurement setup. The nozzle is installed to a closed air circulation which is driven by a centrifugal fan. The maximum velocity of the air leaving the nozzle is about 20 m/s and the slit height is about 8 mm. With these experimental parameters, the imaging area is selected as 15x15 mm 2 and the imaging frequency as 20 khz. This combination allows sequential PIV correlation to be computed, i.e. two consecutive frames are correlated to obtain a velocity map. Thus, the sampling rate for the velocity data is 20 khz as well. This high imaging rate limits the camera resolution to 512x512 pix 2. Also the laser pulse duration is limited to 1 μs as a result of the maximum duty cycle of 2 %. The seeding is generated with an ultrasound droplet generator which is immersed in a dedicated seeding water tank. Before entering the measurement section, the air is circulated through the seeding tank. Small water droplets (<20μm) are mixed in the air flow and carried to the measurement plane where they are used as flow tracers. At high velocities the droplets are expected to follow the flow adequately. In total 20 000 images are collected for PIV processing. Examples of images captured in the measurement plane are presented in Fig. 3. The image quality is very good; only a few large particles are over exposed and the gray scale distribution of the image occupies the full dynamic range of the image.

Figure 3. Examples of particle images. 4 Results Figure 4 portrays an example of velocity field obtained from the PIV computation. The lack of seeding particles in the middle of the vortices causes some additional uncertainty in the velocity estimates. In general, the PIV interrogation successfully predicts the velocities also in the high-gradient regions. The flow field is characterized by the high-speed jet out of the slit and vortices developing in the shear layers. Figure 5 presents the mean velocity field and the velocity RMS field indicating active shear layers. The data is further analyzed by computing spectral estimates in various locations in the flow field. This is done by establishing point-wise velocity time-traces at desired locations over the set of 20'000 velocity fields. A short piece of such a time-trace is given in Figure 6 as an example. This data in sent to the 1D spectral estimation yielding the traditional PSD estimate presented in Fig. 7. There are two dominant peaks below 1 khz, which are clearly related to the vortex dynamics. The salient feature of the HS-PIV data is the inherently dense spatial grid of data which allows detailed analysis of the bulk flow, shear layers and the jet without any a priori information of their actual location.

Application notes Industrial monitoring solutions - Process industry Figure 4. An instantaneous flow field. Figure 5. Mean and RMS fields of the flow. Figure 6. Time-trace of the velocity y-component in the lower shear layer.

Figure 7. Spectrum estimated for the velocity y-component in the lower shear layer. 5 Conclusions The application of diode lasers to PIV measurements offers very attractive possibilities. Compact and robust equipment, freely programmable bursts of pulses, flexible guidance of light to the measurement volume and affordability are the most important features of diode lasers. This work demonstrated that although the power provided by a diode laser does not match the power provided by pulsed solid-state lasers, the diode lasers present an adequate choice even for high-speed PIV. About the author Hannu Eloranta (Dr.Tech.) has been working as a researcher in the Group of Experimental Fluid Dynamics at Tampere University of Technology. His research topics include several aspects of flow dynamics, such as turbulence, fluid-structure interactions and flow control. In addition he has been developing optical measurement techniques and analysis methods for fluid mechanics. Currently he is working in Pixact Ltd - a company specialized in developing optical measurement techniques. Pixact Ltd Postitorvenkatu 14 33840 Tampere FINLAND www.pixact.fi