SAMPLE HEAT PUMP WIRING DIAGRAMS

Similar documents
9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.

Installation Instructions

Specification and Design Catalog. Waterside Economizer

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits

Indoor Unit Controller (IUC) Quick Reference and Fault Diagnosis

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Product Family: Electro Mechanical Relays Number: AN-LC-008

FOR SERVICE TECHNICIAN S USE ONLY

INDOOR UNIT CONTROLLER (IUC) Operation Manual

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

Modular Room Control (MRC) Series Expansion Board

FOR SERVICE TECHNICIAN S USE ONLY

289H LSS Installation & Operations Manual Overview

FX 2 Instruction Manual

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

A4988 Stepper Motor Driver Carrier, Black Edition

-----other notes This picture was taken from here:

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

Progressive Industries, Inc. EMS Electrical Management System

SAVE THESE INSTRUCTIONS

UNIT CONTROLLER 7 (UC7) Operation & Installation. Hydronic Units

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

Abstract. GLV User Manual 1

CORE BASICS COMPETENCY EXAM README RICOH GROUP COMPANIES

SS2200 Remote Controller

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit.

LCMM024: DRV8825 Stepper Motor Driver Carrier,

ELECTRICAL CONTROL SYSTEMS 1

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Air Conditioning Technical Data FVA-A > FVA71AMVEB > FVA100AMVEB > FVA125AMVEB > FVA140AMVEB

A4988 Stepper Motor Driver Carrier with Voltage Regulators

Digital Fan Controller Unit Troubleshooting

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Wiring Diagrams INDEX. UNIT DESCRIPTION DRAWING NUMBER FIG. NO. 09DK Field Wiring 09DK DK054,064

High Frequency Power Supply Board IS200HFPRG_A

SPIRIT. Phase 5 Analog Board Computer and Electronics Engineering

2. Site Planning lists the prerequisites and physical requirements for installing the 289H M LSS monitor.

Basic Electricity 10 Hour - Part 1 Student Workbook Issue: US140/10/2a-IQ-0402A. Written by: LJ Technical Dept

MP6500 Stepper Motor Driver, Digital Current Control

CONTROL PANEL WIRING SPECIFICATIONS

Models: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506

Safety Switches with Separate Actuator, Metal Housing

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

Starzone 4000 Master Control Panel Figure 2.1 Master Control Panel

Checking the compatibility with IT (ungrounded) and corner-grounded delta systems. EMC filter +E200 (690 V drives and drive modules)

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL. Basic Outline of Operation for Distro Controllers

CLIPLINE complete. The modular terminal block system for all applications

Operating instructions. Speed monitor D / / 2014

Operating instructions. Switching amplifier DN0210 DN / / 2015

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q

AutoRanging Digital MultiMeter

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Lecture 6 Contactors and Motor Starters

72In LED Lit Nutcracker Item # CAUTION: IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Commercial Controls. Advanced control for saving time and money

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

A4988 Stepper Motor Driver Carrier

EMS Electrical Management System

For Powerstax D2000 DC-DC Power Cartridges Used in Powerstax S6000 Power Shelves

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

Robocolor II System. users guide

ETM-2050/ETM-2051 Service Manual

OPERATION MANUAL.

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA181, WA241. Contents. General Notes. Important

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

RTK3 Logic Controller User Manual Revised

AUDIO AMPLIFIER PROJECT

SAVE THESE INSTRUCTIONS

MX1 Reversible AC Motor Controller. Supplementary Wiring Examples

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

ELECTRICIANS REGULATIONS EXAMINATION 21 November 2015 QUESTION AND ANSWER BOOKLET

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

OPERATING AND SERVICE MANUAL. Universal Interface Device 45

P216 Series Condenser Fan Speed Controller

Installation Instructions

Blueprint Drawings & Wiring Diagrams. for branch circuits

4X4 Driver Shield Manual

IOA and IOB Inputs and Outputs Expansion Module

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

CENTERLINE 2100 Motor Control Center with IntelliCENTER Technology Using an EtherNet/IP Network

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT. Test Code: 5936 Version: 01

IEC Cord-Sets IEC CONNECTORS

Thermoelectric Cooler Controller TED1000

P522 Signal Processor

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

EMS Electrical Management System

Building the Communication Cable

SECTION DISCONNECT SWITCHES

Network Design and Setup

Transcription:

When multiple switches are connected in series with each other, they all must be in the closed position for current to travel through the circuit, thereby energizing the load. Safety switches, for example, are always connected in series. The current in a series circuit is the same at all points. Parallel circuits operating with the same power supply have the same voltage applied to them. Parallel circuits operating with the same power supply can (and normally do) have different currents flowing through each branch. Loads connected in parallel can be (and often are) controlled by different switches and controls. Electric current always follows the path of least resistance. The last point listed above is very important when considering safe working practices. service technician is always at risk when working with energized power circuits you must make sure that you never become the path of least resistance for electric current! HET PUMP WIRING DIMS variety of wiring diagrams is used in the HVCR industry. Each plays an important role in the troubleshooting process. The basic diagrams used are the component arrangement (or pictorial ) diagram, the point-to-point schematic diagram, the ladder diagram, and the type of combination diagram that contains both the component arrangement diagram and the ladder diagram in the same document. ll other wiring diagrams are basically variations of one of these types of drawings. Unless otherwise noted, all wiring diagrams depict switches and contacts in the deenergized or normal mode. This means that they are shown as they are when the power to the equipment is off. normally open switch or contact is open when power to the unit is off, and a normally closed switch or contact is closed when power to the unit is off. Supplying power to the coil of a will result in a reversal of position for all switches or contacts in the. Normally open contacts will close when the coil is energized, and normally closed contacts will open. Component arrangement diagram component arrangement diagram (sometimes called a pictorial diagram) is used to determine the physical location of all of the components in a control cabinet. Components are identified using either their full descriptive names or abbreviations spelled out in the legend. The component arrangement diagram for a three-phase heat pump is shown in Figure - on the next page. Connecting wires are not shown HET PUMP ELECTRICL SYSTEMS 9

in this particular diagram. It is common for inexperienced technicians to attempt to use the component arrangement diagram for troubleshooting purposes, especially when the wiring is drawn on the diagram. This is an unwise practice it is very difficult to determine the functions of individual circuits and system components using a component arrangement diagram. ladder diagram more clearly shows which switches control specific loads in the equipment. Use the ladder diagram to troubleshoot a system, and the component arrangement diagram to locate the physical component that needs to be checked. Point-to-point schematic diagram point-to-point schematic diagram is intended to provide the field technician with a detailed representation of the actual wiring in a specific system. Each wire in the circuit is depicted and, when necessary, the color of each wire is provided. Factory wiring and field wiring are identified. Component placement and location within the control panel also are shown on some diagrams. The point-to-point schematic diagram shown in Figure - illustrates the electrical wiring for a 00/0-V indoor air handler unit that is controlled by a -V circuit. You can 08/0-0- L L L Thermostat Fused disconnect switch (provided by installer) VR V R M F Y Use copper conductors only Equipment ground Compressor contactor junction box Defrost clock timer ypass 7 9 8 F F Control fuses Outdoor fan and defrost High-voltage junction box R O Y Timed-off control Figure -. Component arrangement diagram Resistor Transformer ypass delay Outdoor fan contactor Control mbient thermostat Indoor blower 0 CHPTER SIX

WH/ WH/ WH/ WH/ WH/ WH/ 00/0//0 power supply per local codes CF YL C IFM* ir flow selection: Terminal = Low speed Terminal = Medium speed Terminal C = High speed *Thermally protected internally CN- WH / / Line-voltage wiring wiring NOTES I-PM I-PF NOTE / / WH/J WH/ WH/ WH/. For 00-V operation, swap red transformer lead and insulated cap on 00-V center transformer terminal.. When heaters are used, discard I-PM with attached leads and connect I-PF to the mating plug in the heater control box.. For replacement fuse, use - automotive style for all models. I-PF I-PM 0 V 00 V COM NOTE V TNS NOTE FU FRC F F WH/J field connection LEGEND CF Fan capacitor CN Wire connector FRC Fan coil FU Fuse IFM Indoor fan motor PF Polarized plug (female housing) PM Polarized plug (male housing) TNS Transformer Wire colors lack lue Green Red WH White YL Yellow Figure -. Point-to-point schematic diagram HET PUMP ELECTRICL SYSTEMS

make the following observations about the indoor section of this heat pump by examining Figure -:. The indoor fan motor (IFM) is equipped with a permanently connected run capacitor (CF, see item on the drawing), which means that it can be properly identified as a permanent split-capacitor (PSC) motor.. The indoor fan motor is controlled by fan contacts - (see item on the drawing).. The indoor fan motor is controlled by a -V circuit that connects to the fan coil (FRC) at terminals - (see item on the drawing).. The transformer (TNS) is protected with a - automotive-type fuse (see item and Note on the drawing). Note that dashed lines are used to draw boxes around some components. This indicates that the component is itself made up of several parts that are internally connected, either mechanically or electrically, with each other. Notice also that the colors of individual wires are given, and that the actual point-to-point connections made at the factory are shown. close study of the diagram reveals that power wiring is shown in the upper portion of the drawing and control wiring is shown in the lower portion of the drawing. The legend explains the meaning of the abbreviations used to identify various components in the drawing. Notes also are provided to convey important installation requirements. For example, Note informs you that a wiring change must be made at the transformer when the unit is not supplied 0-V power. Obviously, a close reading of this diagram is necessary for installers and service technicians working with this equipment. Ladder diagram ladder diagram is designed to allow a technician to isolate various electric circuits in a system, making it easier to understand the functions of the different switches and loads that may be present in each circuit. Unlike the previous diagram, the ladder schematic does not illustrate the actual point-to-point wiring connections. Rather, the ladder diagram utilizes the least number of lines possible to describe the operating functions of each circuit. The ladder diagram illustrated in Figure - is a representation of the same circuit shown in Figure -. s you can see, the vertical lines identified as L and L represent the power supply to the unit and are located on the far left and right sides of the diagram. Individual CHPTER SIX

circuits are represented by horizontal lines drawn from L to L like rungs on a ladder. Loads and components are represented by symbols placed on the horizontal rungs. This basic construction remains the same as circuits are added to the system. ladder diagram is read by tracing power supplied on L to switches and loads, and back to the source on L. If either side of a circuit supplying power to a load is open, the load cannot operate. The control part of the system is drawn in the same way. It is often the lower portion of the diagram, as in Figure -, or it may be drawn as a separate diagram in some cases. Wire colors usually are not identified on a ladder diagram. L PM Polarized plug (male housing) The purpose of this type of TNS Transformer diagram is to show clearly how each circuit in a system operates. Figure -. Ladder diagram Notice that it is a simple matter to read the controlling function of each circuit when using a ladder diagram. For example, you can quickly determine that fan contacts - (F) are used to control the indoor fan motor, while fan contacts - (F) are used when resistive heaters are installed in this particular air handler. When a low-voltage circuit is completed between points and at the polarized plug, the fan coil (FRC) will be energized (at -), thus causing contacts - and - to close. When the fan contacts - close, the indoor fan motor operates on medium speed (because motor terminal is connected to the contacts). F FRC 00/0--0 C 00 V V ac IFM TNS F To resistive heat plug field connection LEGEND CF FU CF Fan capacitor CN Wire connector FRC Fan coil FU Fuse IFM Indoor fan motor PF Polarized plug (female housing) L HET PUMP ELECTRICL SYSTEMS