Guifré Molera, J. Ritakari & J. Wagner Metsähovi Radio Observatory, TKK - Finland

Similar documents
D77: Data Acquisition Prototype at Telescope

Test report of transparent local/remote application programming interface for storage elements

Mark 6: design and status update

MASSACHUSETTS INSTITUTE OF TECHNOLOGY HAYSTACK OBSERVATORY WESTFORD, MASSACHUSETTS May 2011

Mark 6 Next-Generation VLBI Data System

D Demonstration of integrated BoD testing and validation

Server Specifications

Lessons from EXPReS and the future of e-vlbi. 2nd Terena E2E Workshop, Amsterdam,

WaveView. System Requirement V6. Reference: WST Page 1. WaveView System Requirements V6 WST

LBA evlbi Developments. Chris Phillips evlbi Project Scientist 14 September 2007

HP ProLiant blade planning and deployment

IVTW - Auckland

Upgrading and Repairing: Build a PC with Scott Mueller

John Fragalla TACC 'RANGER' INFINIBAND ARCHITECTURE WITH SUN TECHNOLOGY. Presenter s Name Title and Division Sun Microsystems

No More Waiting Around

HARNESS THE POWER OF GAMING GAMING DESKTOP PC. Infokit

PoS(11th EVN Symposium)112

PoS(10th EVN Symposium)098

WP7. Mark Kettenis April 18, Joint Institute for VLBI in Europe

EVN/JIVE Technical developments. Arpad Szomoru, JIVE

Server Specifications

Enterprise Server Midrange - Hewlett Packard

Manual M5a99x Evo R x Sockel Am3+ Atx Ddr3

VLBI progress Down-under. Tasso Tzioumis Australia Telescope National Facility (ATNF) 25 September 2008

PoS(EXPReS09)036. e-vlbi Networking Tricks. Paul Boven, for the EXPReS team Joint Institute for VLBI in Europe (JIVE)

Mark 5C VLBI Data System

MegaGauss (MGs) Cluster Design Overview

Combat Model with Advanced I/O Design. Designed to support three legacy PCI Devices. Dual Intel I210AT Gigabit Ethernet

FPGA APPLICATIONS FOR SINGLE DISH ACTIVITY AT MEDICINA RADIOTELESCOPES

vstart 50 VMware vsphere Solution Specification

SecurOS Server / Workstation Specifications INTELLIGENT SECURITY SYSTEMS 1480 US 9 NORTH, SUITE 202 WOODBRIDGE, NJ v.2.1

PoS(EXPReS09)023. e-evn progress. 3 years of EXPReS. Arpad Szomoru 1

Voxco Command Center, Voxco Online, and Voxco Dialer - Technical specifications & Recommendations

NEXPReS WP8 Progress Meeting

IDENTIFICATION OF VOLATILE AND NON-VOLATILE STORAGE AND SANITIZATION OF SYSTEM COMPONENTS JUNIPER NETWORKS EX2300-C

THE VLBA SENSITIVITY UPGRADE

Robert Jamieson. Robs Techie PP Everything in this presentation is at your own risk!

SERVER RSV-S4 USER Manual

Requirements and Dependencies

Anthony Rushton. University of Manchester

Mark 6 16Gbps VLBI Data System

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

SANGFOR AD Product Series

Solving the Data Transfer Bottleneck in Digitizers

RocketStor 5315 Quick Installation Guide V1.0 Jan. 4, 2013

Gigabyte Ga-z77x-d3h Intel 7 Series Motherboard Specs

Demartek December 2007

Mark 6 16Gbps VLBI Data System

Pegasus 5 Series. Ernitec Smart Backup. Massive Power. Optimized for Surveillance. Battery Backed 12Gbps Raid Controller.

June 2004 Now let s find out exactly what we ve bought, how to shop a new system and how to speed up an existing PC!

ASN Configuration Best Practices

IDENTIFICATION OF VOLATILE AND NON-VOLATILE STORAGE AND SANITIZATION OF SYSTEM COMPONENTS JUNIPER NETWORKS EX P/24T/24T-DC

SANGFOR AD Product Series

Avaya Call Recording Solution Configuration

Long Baseline Array Status

STAGES HARDWARE. Recommended Hardware Specifications. Official Release Version 1.15 August 30, Secure Global Solutions

Upgrading the Mark5 motherboard to the SE7520BD2 Server Board

MCS - Data Recorder Preliminary Design & Verification

Enough speed? Specs and applications. Add 5GbE to NAS

Assessing performance in HP LeftHand SANs

Overview. About the Cisco UCS S3260 System

Quotations invited. 2. The supplied hardware should have 5 years comprehensive onsite warranty (24 x 7 call logging) from OEM directly.

32-bit Windows XP / Vista / 7 / 8 / Server bit Windows 7 / 8 / Server 2008 R2 / Server Core 2 Duo E4400, 2.00 GHz

Infokit. Harness the Power of Gaming GAMING DESKTOP PC

T-CAP (Converged Appliance Platform)

Real-Time E-VLBI with the SFXC Software Correlator. Mark Kettenis Aard Keimpema JIVE

USB 3.0 / esata 8-Bay Hot-Swap 2.5/3.5 SATA III Hard Drive Enclosure with UASP 8-Bay SATA 6 Gbps Enclosure for HDD / SSD

High Performance Computing

GV-600B, GV-650B, GV-800B

WHITE PAPER AX WAIT, DID WE JUST BUILD A WIRELESS SWITCH?

SMART SERVER AND STORAGE SOLUTIONS FOR GROWING BUSINESSES

Input/Output. Today. Next. Principles of I/O hardware & software I/O software layers Disks. Protection & Security

The Missing Piece of Virtualization. I/O Virtualization on 10 Gb Ethernet For Virtualized Data Centers

ASR 5500 Hardware Platform Overview

Virtual Environment For Yemen Mobile

evlbi Research in the European VLBI Network Steve Parsley, JIVE

inettest a 10 Gigabit Ethernet Test Unit

Extreme I/O Expandability with High VR Power Efficiency

TCP offload engines for high-speed data processing

SETTING UP A GB-X3 LINK FOR 2 or 3 Gbps OPERATION

IBM and HP 6-Gbps SAS RAID Controller Performance

PPC-F-Q370 SERIES AI Ready Panel PC Based on Intel OpenVINO toolkit

System Requirements. PREEvision. System requirements and deployment scenarios Version 7.0 English

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme

STOREONCE OVERVIEW. Neil Fleming Mid-Market Storage Development Manager. Copyright 2010 Hewlett-Packard Development Company, L.P.

Vess A2000 Series. NVR Storage Appliance. Milestone Surveillance Solution. Version PROMISE Technology, Inc. All Rights Reserved.

E-VLBI Development in NICT

EXPReS SA1: at the half-way mark. Arpad Szomoru JIVE

10GE network tests with UDP. Janusz Szuba European XFEL

IP Audio Conference Solution

Vess A2000 Series NVR Storage Appliance

Cisco MCS 7825-I1 Unified CallManager Appliance

MSc-IT 1st Semester Fall 2016, Course Instructor M. Imran khalil 1

HW SCREAMER! Video Editing and Gaming Computer Built with love but raging with power. Owner's Manual

Hewlett Packard Enterprise HPE GEN10 PERSISTENT MEMORY PERFORMANCE THROUGH PERSISTENCE

Analysis of high capacity storage systems for e-vlbi

Streamlined feature-rich ATX UP serverboard. The most scalable I/O expandability

Solution Recipe: Increase Data Protection Using Intel vpro Technology

(Please refer "CPU Support List" for more information.)

StoneGate IPS. Hardware Requirements for Version 5.2.0

Transcription:

European 4-Gbps VLBI and evlbi Click to edit Master subtitle style Guifré Molera, J. Ritakari & J. Wagner Observatory, TKK - Finland 1

Outline Introduction Goals for 4 Gbps Testing Results Product Conclusions and future 2

Introduction During this year 2009 Metsähovi has been special active in e-vlbi opportunities: We participated in IYA 2009 demo, 100 hrs of Astronomy demo and the e-vlbi ToO sessions (May/June/July). In addition last geo-vlbi session ( EURO99 in May) was also done with real-time streaming to Bonn. PC-EVN + Tsunami UDP. With a new 10 Gigabit card installed in Mark5A we have to perform 1024 Mbps soon with the EVN community. 3

Introduction Ø But we always look for further transfer rates Ø A real astronomical data at 4 Gbps streamed from Onsala and locally recorded at Metsähovi has succesfully been demonstrated. (Q3 2008) Ø A 8 Gbps live demonstration was performed during last 7th International evlbi workshop at Shanghai. Data was streamed from Metsähovi to Onsala. No packets were lost. No crash on the network. 4

Introduction But we always look for further transfer rates Ø Ø A real astronomical data at 4 Gbps streamed from Onsala and locally recorded at Metsähovi has succesfully been demonstrated. (Q3 2008) Ø A 8 Gbps live demonstration was performed during last 7th International evlbi workshop at Shanghai. Data was streamed from Metsähovi to 5

Goals for 4 Gbps Test the limits of commercial off-the-shelf computers. Test the new 10 Gbps devices: switches, Ethernet boards or FPGA devices as ibob. Test the performance of plain old Internet in high-speed transfers. Use of simple UDP transfers protocols: Tsunami-UDP, VDIF UDP packetizer, VSIB Multicast. Test the performance of hard disks, RAID disk controllers and Port Multipliers (PMP). Detailed analysis at http://www.metsahovi.fi/en/vsib-docs/yebes_presentation.pdf Build a Data Acquisition System capable of streaming and recording at 4 Gbps. Compatible and interactive with current Mark5 A/B/C. 6

Testing - equipment Motherboard Processor RAM memory SATA controller System 1 Asus L1N-SLI WS Rampage Extreme II Two dual-core AMD Pentium Quadcore Native ports HighPoint RR 2522 4 GB 10 Gbps card Chelsio 10 Gbps Max capacity 24 TB (12 disks) Hard disks System 2 Samsung F1 750GB 4 GB Myrinet 10Gbps Samsung F1 1TB 40 TB (20 disks) 7

Testing - equipment Extra RAID controllers tested: Hewlett-Packard SC44Ge Addonics 4 x esata card ADSA3GPX8-4 Addonics 5 internal SATA PMP (24h x 4Gbps) 8

Results 4 Gbps recording is achievable with carefully selected equipment 10 Gbps streams + disks recording are CPU-limited Multi-core processors and threads to divide the load are needed. Only the newest and fastest Samsung hard disks were fast enough, expect the new 2TB disks to be even faster Native ports are faster than RAID controllers. None of the on-board chipset controllers supports FIS-based switching in PMP RAID disk controller ->more disks and good performance Port Multipliers (PMP) allow multiple disks connections. Higher amount of disks might require to divide the disk pack in 2 RAID s set and two UDP streams. TBD Sustained 4 Gbps transfer from 10GBE to disks 9

Results 4 Gbps recording is achievable with carefully selected equipment Only the newest and fastest Samsung hard disks were fast enough, expect the new 2TB disks to be even faster Native ports are faster than RAID controllers. None of the on-board chipset controllers supports FISbased switching in PMP RAID disk controller ->more disks and good performance 10 Gbps streams + disks recording are CPU-limited Multi-core processors and threads to divide the load are needed. Port Multipliers (PMP) allow multiple disks connections. Higher amount of disks might require to divide the disk pack in 2 RAID s set and two UDP streams. TBD Sustained 4 Gbps transfer from 10GBE to disks 10

Results 11

Results II Eight Gbps continuous streaming over production network, no errors, no packet loss Plain old Internet seems to work better than light paths FPGA-generated traffic is even safer than PCtraffic Don t forget to notify the network people before ;). e-vlbi at high rates matches with new FPGA based devices: dbbc, ibob, ibob2, ROACH 100 Gbps Ethernet announced, demos Q3 2009, deployment 2010 12

Product A dedicated equip based on system 2 spec s has been built to clone Mark5 capabilities. An alternative diskpack with 20 disks capacity and 4 PMP has been designed and built. A Mark5C emulator software is being written @ Mh to emulate all possible calls from the Field System. www.metsahovi.fi/en/vlbi/4gexpres An external 500 W PSU and CX4 cable to connect RAID controller and the module is needed. A fan rack shelf cools down the diskpack by blowing the air through the disks. 13

Product A dedicated equip based on system 2 spec s has been built to clone Mark5 capabilities. An alternative diskpack with 20 disks capacity and 4 PMP has been designed and built. A Mark5C emulator software is being written @ Mh to emulate all possible calls from the Field System. www.metsahovi.fi/en/vlbi/4gexpres An external 500 W PSU and CX4 cable to connect RAID controller and the module is needed. A fan rack shelf cools down the diskpack by blowing the air through the disks. 14

Product A dedicated equip based on system 2 spec s has been built to clone Mark5 capabilities. An alternative diskpack with 20 disks capacity and 4 PMP has been designed and built. A Mark5C emulator software is being written @ Mh to emulate all possible calls from the Field System. www.metsahovi.fi/en/vlbi/4gexpres An external 500 W PSU and CX4 cable to connect RAID controller and the module is needed. A fan rack shelf cools down the diskpack by blowing the air through the disks. 15

Product II A full new equipment won t be necessary. The new diskpack system could be compatible with the current Mark5 units that each station. Minor upgrade is needed to have extra PCI-E ports. www.metsahovi.fi/en/vlbi/10gbps/mark5_upgrade.html Ø Mark5 could switch easily between both modes. 16

Conclusions 4 Gbps real-time observations already possible with the current networks. 4 Gbps recording possible with COTS. Non-real-time VLBI transfer also possible. An evlbi demonstration at 4 Gbps with several stations will be perform soon. evlbi becomes easy with 100 Gbps trunk network. 2010 100 Gbps link Finland-Estonia 17

Future work New applications: Kurtosis spectrometer for RFI mitigation Estimates which parts of signal are RFI and removes them First results extremely promising Bit compression for high data rates streams. VLBI spectroscopy and VLBI space satellite tracking. 18