SENTRON 3VL Molded Case Circuit Breakers

Benefits, offering and references

Overvoltage Protection Devices

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Miniature circuit breakers for all applications

Innovative features and solutions for SIVACON S8 siemens.com/sivacon-s8

Overvoltage Protection Devices

Solid-State Contactors

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager

Solid-State Switching Devices

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Lightning and Surge Arresters

Operating tunnels safely Overvoltage protection for critical systems in tunnels

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

Overvoltage Protection Devices

Solid-State Switching Devices

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

The complete universe of Industrial Controls. You have it at your fingertips. sirius

Miniature Circuit Breakers for Railway Applications

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

SECTION SWITCHBOARDS

Siemens Industrial s

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

Overvoltage Protection Devices

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1

SENTRON. Modular, Compact, Communication-Capable. Answers for industry. Switching, Protection and Measuring Devices for Low-Voltage Power Distribution

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium

MV Network Switchgear, Protection and Control

System solutions for your energy requirements

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

ATV630D15N4 variable speed drive ATV630-15kW/20HP V - IP21/UL type 1

ATV650D22N4 variable speed drive ATV650-22kW/30HP V - IP55

Digistart. Soft starters for 3 phase induction motors 7.5 to 800kW (18 to 1600A) 200V, 400V, 575V, 690V

ATV1200A kv kva

ATV1200A kv kva

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

SIMOCODE 3UF Motor Management and Control Devices

What fulfills the highest demands on the current and voltage quality?

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Package Substation. The efficient solution for your electrical distribution network

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Uniform parameterisation, operation, and monitoring of intelligent switchboards

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Switch Disconnectors, Main and EMERGENCY-STOP Switches

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Power Management System. Multifunction Measuring Instruments

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

Siemens tiastar TM Motor Control Center (MCC)

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

IEC & 2 standard. The reference for safe and reliable LV switchboards

Partner conference The digital revolution

Reliable Switchgear from One Proven Supplier

ATV650C13N4F. ATV650C13N4F variable speed drive ATV kW V - IP54 - disconnect switch. Product data sheet Characteristics.

Innovation for MV distribution

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

New Functions and Integrated Communication Capability. The new SENTRON 3VL ETUs SENTRON 3VL. Answers for industry.

MINI-PS AC/10-15DC/8

L.V. Systems & Solutions

ATV680C45Q4X1 Low Harmonic Drive System ATV /355kW V - IP23

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

ATV650C16N4F variable speed drive ATV kW V - IP54 - disconnect switch

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Overvoltage Protection Devices

DC Substations / Supply Program

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Distribution Systems ALPHA. Answers for infrastructure and cities. Edition Catalog LV 51

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV630D30N4 variable speed drive ATV630-30kW/40HP V - IP21/UL type 1

ATV930D45N4 variable speed drive - ATV930-45kW - 400/480V - with braking unit - IP21

ATV71EXA2C71N4 enclosed variable speed drive ATV71 Plus kw - 400V - IP23

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

Easy, efficient and always up to date the SIRIUS modular system

SSW06. Soft Starters.

Converter SINAMICS G150. Type 6SL37102G

Now even more application possibilities In all facets of semiconductor protection

ALLTEC PROTECTION PYRAMID TM FOR PHOTOVOLTAIC SOLAR FIELD

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Transcription:

Power Distribution

Safety and protection for wind turbines Perfectly coordinated components for low-voltage power distribution

Our world is changing Global warming Global greenhouse gas emissions Global average temperature 0.7 0.5 0.0 + 0.76 C Industry (direct primary energy consumption) 22 % Forestry 14 % 40Gt CO2e Industry (electricity) 11 % Buildings (electricity) 13 % Buildings (direct primary energy consumption) 8 % -0.5 1850 1900 1950 2000 Agriculture/waste 18 % Transportation 14 % Rising energy costs US$ / Barrel crude oil 60 50 40 30 20 10 0 1960 1970 1980 1990 2000 2010 by www.tecson.de Solutions for the more efficient use of energy must be put into action Siemens AG 2012. All rights reserved.

Expected changes of the energy mix a scenario Coal Petroleum Nuclear energy Gas Savings and energy efficiency Water Wind Sun Biomass Energy consumption

Market development of the wind turbine market Market development (worldwide) Annual total installation in MW BTM Consult 03.2011 +16% 72.475 81.350 39.404 46.000 53.875 60.475 2010 2011 2012 2013 2014 2015 Americas Europe SEA OECD-Pacific RoW

Increasing performance capacity and costs higher risk Increase in capacity: In just 20 years, the yield from wind turbines has increased 50-fold. With the current 6 MW turbines and the 10-15 MW turbines which are already in the development phase, this yield will again increase many times over. Rotor diameter Hub height 1990 2012 Rated power Rotor diameter Hub height 250 kw 30 m 50 m 1,500 kw 70 m 100 m 3,000 kw 90 m 105 m 6,000 kw 126 m 135 m Annual yield 400,000 kwh 3,500,000 kwh 6,900,000 kwh approx. 20.000.000 kwh

Design of wind turbines Main circuit Additional system components Auxiliary Circuit

LV products designed to ensure the electrical availability & reliability of Wind turbines SENTRON circuit protection/ monitoring devices SENTRON Control and Switch disconnectors Gen ~ Aux ~ SENTRON protection and measuring devices SIVACON busbar trunking systems

Safe power distribution in the main circuit The main circuit is responsible for the basic function of a wind turbine, i. e. the generation of electric power and the grid-compliant infeed of this power into the grid. Highlights Comprehensive product portfolio for safe power distribution in the main circuit Maximum availability of the wind turbine thanks to high product quality Coordinated products satisfy requirements even under extreme conditions Reliable components support grid-compliant power quality

SIVACON 8PS busbar trunking system Advantages compared to cables: Pre-installation in the factory simplifies the on-site installation process Only little space required, even in case of complex installations inside the nacelle High protection against ingress of water for vented system with IP34 and IP54 (sprincler-suitable) High protection of all conductor surfaces due to non-ageing coating Sheet steel enclosure to reduce EMC effects to a minimum

SIVACON 8PS busbar trunking system Advantages for protection against fires Advantages for protection against fires: Significantly lower combustive energy due to sheet steel enclosure (Reduction of combustible materials acc. VdS 3523) Maximum short-circuit strength High short-circuit strength of the tap-off units High thermal loading capacity with regards to effects of a lightning strike (Halogen free)

Switching and protecting the main circuit Effective protection of the main circuit in case of overload or short circuits Safe disconnection from the grid during maintenance Locking mechanism against unauthorized switching-on for maximum protection of the maintenance personnel Communication-capability for optional connection to the electrical management system of the wind turbine Metering Generator Power supply company

3WL air circuit breaker Maximum system availability thanks to the rapid replacement of devices and preventive maintenance Simple diagnostics for the con-tact condition in order to deter-mine the service intervals Voltage range 690 V +/- 20% to 1,150 V and cold climate capability possible Modular design and same complete range of standard accessories, e.g. remote control due to motorized operating mechanism Externally controlled 3WL air circuit breaker for use with variable frequencies

Effective protection concept for the converter Protection of the power semiconductors against uncontrolled failure due to short circuit and overload High operational reliability due to super-quick disconnection characteristic Increased system availability thanks to optional fuse monitoring and integration into superordinate communication systems of the wind turbine DC AC Var. frequency AC Grid frequency to the generator to the grid Rectifier Inverter Converter

SITOR semiconductor fuses Effective protection of the sensitive power semiconductor with SITOR semiconductor fuses Super-quick disconnect characteristic of SITOR semiconductor fuses Increased system availability thanks to optional fuse monitoring Flexible installation thanks to a range of designs and mounting options

Safe power supply for the auxiliary circuits Electrical equipment guarantees the vital functions of the wind turbine, e. g. pitch and yaw control systems and ventilation or hydraulic systems. Equipment of this kind must be fitted with coordinated components in order to ensure effective protection against overvoltages, overloads and short circuits. Highlights A safe power supply guarantees maximum functionality Reliable protection against over-voltage, overload and short circuits Interruption-free operation thanks to a comprehensive protection concept for electrical operating mechanisms Products certified worldwide for the standardcompliant installation of protection concepts

High infeed protection for the auxiliary circuits Optimal overload and short circuit protection by the 3VL molded-case circuit breaker and the 3NP1 fuse switch disconnector.

3VL molded-case circuit breaker 3NP1 fuse switch disconnector A safe and requirement-based power supply for the control and auxiliary circuits Flexible adaptation to the required tripping characteristic High current carrying capacity with associated low derating Increased system transparency thanks to integration into the communication systems of the wind turbine

Perfect protection for auxiliary circuits Effective line protection and protection of electrical equipment against overload and short circuits with miniature circuit breakers Optimized personal safety and fire protection against dangerous residual currents with UC sensitive RCCBs 5SM2 RC unit for personal safety and protection against electrically ignited blazes 5SY miniature circuit breaker, 4-pole 5ST3 remote-controlled operating mechanism for remote switching of the MCB 5ST3 undervoltage releases protect downstream loads in the circuit against risks from undervoltage 5ST3 auxiliary switches and 5ST3 fault signal contacts for displaying switching state or protective tripping

Miniature circuit breakers RCCBs Maximum safety thanks to line protection against overload and short circuits UC-sensitive residual current operated circuit breaker for maximum personal safety Increased system availability thanks to remote reconnection with the assistance of motorized operating mechanisms Early detection and signaling of residual currents prevents system downtimes

Requirement-based motor protection concepts A modular system consisting of standard components is available to switch, protect and start the various electrical operating mechanisms. The components are perfectly coordinated and can be combined with ease. Highlights Extensive modular system for controlling, protecting and monitoring the operating mechanisms Integrated soft starting and speed-variable operation for requirement-based control Diverse diagnostics functions and integration of these into the wind turbine s communication systems Use of SITOR semiconductor fuses to achieve type 2 co-ordination

Motor protection concepts Circuit diagram Product combination Application Function Single-phase small loads, e. g. fans in control cabinets Miniature circuit breaker with motor protection characteristic C for protection against overload and short circuits Insta contactor for normal switching duty Pump motors, e. g. for cooling water or gear oil without requirements for speed-variable operation Motor-protective circuit breaker for protection against short circuits Alternative cost-effective solution: fused motor starter combination, especially for use for motor feeders SIRIUS contactors for normal switching duty Overload relays for protection against overloading of the motor Siemens AG 2012. All rights reserved.

Motor protection concepts Circuit diagram Product combination Application Function Motors which are operated with soft starters, e. g. service crane Motor-protective circuit breaker with overload relay function for protection against short circuit and overload in jus one device Soft starter for the soft, protective starting of motors Protection of motors which are operated with soft starters, e. g. tower elevator when there are special requirements in order to achieve type 2 coordination Switch disconnector with fuses for semiconductor and line protection through SITOR semiconductor fuse in order to achieve type 2 coordination Door-coupling rotary operating mechanism allows isolation outside the control cabinet for maintenance purposes Soft starter for the soft, protective starting of motors Overload relay for overload protection of the motor Siemens AG 2012. All rights reserved.

Motor protection concepts Circuit diagram Product combination Application Function Speed-variable operation of e. g. cooling fan motors which are control-led in accordance with the ambient temperatures inside the nacelle SITOR semiconductor fuse for the cost-effective protection of the power semiconductors of the frequency converter Achieving type 2 coordination Contactor for normal switching duty Frequency converter for gene-rating variable motor speeds. The protective function against over-load is covered by the frequency converter Control of e. g. soft-starting yaw operating mechanisms Compact feeders combine a circuit breaker, solid-state overload relay and contactor in just one device Low variance of devices thanks to wide setting ranges Soft starter for the soft, protective starting of motors Siemens AG 2012. All rights reserved.

Motor protection concepts Circuit diagram Product combination Application Function It is important that motors can be put back into operation as quickly as possible following a fault, especially in the case of motors which relate to safety functions Repair switch for manual isolation, e. g. for maintenance purposes or for the emergencystop function SITOR semiconductor fuse to protect the semiconductor of the high-quality frequency converter against short circuits. Achieving type 2 coordination. Rapid putting back into operation following a fault bay replacing the fuse Decentralized frequency converter for generating variable motor speed. The protective function against overload is covered by the frequency converter. The device is suitable for use in harsh ambient conditions Siemens AG 2012. All rights reserved.

Optimal cabinet air conditioning and lighting The control cabinet air conditioning ensures constant operating temperatures in all control cabinets, no matter what the weather. The control cabinet lighting offers maintenance staff optimal visibility for maintenance and repair work. Optimum and long air duct for cabinet air-conditioning Highlights Operation-compatible climate in the control cabinet in every type of weather Effective protection against overheating and mold formation Wide-ranging portfolio of air-conditioning equipment for the most varied requirements Optimal visibility thanks to compact cabinet lights 35 C Warm air from control system 55 C Cold air return 25 C Control cabinet

Safe disconnection from the network during maintenance The high-quality switch disconnectors for safe and reliable disconnection from the network. Highlights Reliable protection of maintenance staff against unauthorized reconnection Safe disconnection of the auxiliary circuits and loads from the network Further options, e. g. as an EMERGENCY-STOP switch for increased safety in hazardous situations

Lightning/overvoltage protection Owing to their exposed locations, wind turbines are subject to a highended risk of being struck by lightning. Therefore they require extensive lightening- and overvoltage protection matching the respective type of turbine. The necessary risk assessment must be based on the maximum risk possible (risk level I) in accordance with IEC 62305/IEC61400-24. It must take account of the possible lightning paths, e. g. from the rotor blade, hub and the nacelle via the tower down to the foundation. In addition to the lightning partial currents which can be expected, switching surges must also be taken into consideration.

Protection against lightning and overvoltage By using our graded portfolio, you can protect not only the supply circuit equipment, but also the data lines. Highlights Prevention of system failures through graded lightning and overvoltage protection High level of protection thanks to remote signaling of the device condition and simple replacement of the modules Control technology protection thanks to overvoltage protection for data lines

Risk zones (LPZ) in wind turbines LPZ Area Risk Wind turbine parts affected 0a Area at risk of a direct light-ning strike Lightning Rotor blades Building 400/690 V power supply/ transformer station 0b Protection area in which the system is not exposed to a direct lightning strike High-energy unattenuated electro-magnetic fields Nacelle Externally attached sensors (wind speed/ direction; climate) Hazard lights (aviation lights) or 1 Inside the nacelle/tower Transients triggered by: electromagnetic fields, switching operations (SEMP) Protection devices and switchgear Generator Converter Motorized operating mechanisms/frequency converter Air conditioning systems 2 Shielded components inside the nacelle or tower Lower-energy transients triggered by: Switching operations (SEMP) Control components (e. g. pitch) Communication components Electrostatic discharge (ESD) Siemens AG 2012. All rights reserved.

Graded portfolio for overvoltage protection from medium voltage to data networks Protection of the main circuit Energy Data Protection of data and measuring systems Special arrester versions for use in close proximity to the generator and the converter. They are leakagecurrent-free and insensitive to operational voltage peaks. Surge protection devices for the protection of analog signal circuits and the lines of digital status signals. Special arresters for resistance-based temperature measuring systems (e.g. Pt100) are available. Protection of auxiliary circuits Suitable surge protection devices for a range of mains types and applications. Protection of communication interfaces Suitable surge protection devices for all common fieldbus systems, such as Profibus, CAN, CANopen and DeviceNet. Suitable arresters with RJ11, RJ12, RJ45 sockets for the protection of phone and ISDN systems. Protection of sensitive loads Protection for Industrial Ethernet Surge protection devices with ultra strong voltage limitation for the protection of sensitive loads, such as UPS systems, measuring instruments and the power supply lines of controls. Surge protection devices for communication systems based on Gigabit Ethernet, such as Profinet, EtherCAT, EtherNet/IP and EthernetPOWERLINK. Protection of medium- voltage systems Protection for serial interfaces in the base of the tower at the medium-voltage transformer in the incoming-feeder cabinet 3EK4 and 3K7 surge arresters offer the best protection against overvoltages in medium-voltage distribution grids up to a maximum system voltage of 72.5 kv. Surge protection devices for serial interfaces RS232 and RS485 with the correct Sub-D9 connection.

High system transparency with measuring devices Increased system transparency thanks to measuring, providing and communicating of consumption data and electrical characteristics Measuring of the current quality of the main circuit Measuring of the internal consumption of the control and auxiliary circuits within the wind turbine Integration into the communication systems of the wind turbine Recording of measured data and querying via the wind park control rooms

7KM PAC measuring devices Early information about critical system states increases safety Graphical LCD, intuitive operation with text display in ten languages and 4 control keys Expandable due to optional communication modules for integration into superordinate communication systems Connection to the wind park control rooms Comfortable configuration software included in scope of delivery

Optimal availability thanks to communication Integrated communication makes diagnostics and control an easier process and increases the availability of wind turbines. Highlights Optimal system transparency thanks to communication-capable products Increased system availability thanks to preventive maintenance and diagnostics functions Flexible adaptation to requirements thanks to graded communication classes Fully informed thanks to intelligent measurement technology

Flexible adaptation through graded communication classes Basic functions: Forwarding of data to other systems via bus system PROFIBUS Modbus Ethernet Measurement function in the circuit breaker Further processing of measured values and diagnostics/status signals in process control systems

Flexible adaptation through graded communication classes Configuration examples: Forwarding of status signals via a configurable CubicleBus digital output module, e. g.: Ready-to-close status Connected position Limit violation signal (e. g. temperature, current...) Reason for tripping signal (e. g. short circuit, overload...) Collection of switching state data (e. g. ACB, SPD, LS, RCM) via DI to 7KM PAC4200 and forwarding the status information to PN (use of 7KM PAC in addition to the main measurement function)

Comprehensive and competent product offering We offer the world s most comprehensive portfolio of electrical and electronic drive solutions, automation and communication components and power distribution systems for wind turbines. In addition to this, we also offer fire detection and fire extinguishing systems. Highlights The widest portfolio for automation and power distribution in wind turbines Coordinated TIA and TIP system architectures Close proximity to customers thanks to a worldwide presence Many years of proven experience in the industry

Comprehensive and competent product offering Wind Turbine Generator Automation/SCADA/HMI Busbar trunking systems Protection devices Electrical operating mechanisms Generator/Converter Camera surveillance Medium-voltage transformer Medium-voltage switchgear Circuit breakers Control panel Busbar trunking systems Control room Automation Monitoring Controlling Infeed meter Operation and service Preventative maintenance Reconstruction Transformer station and high-voltage transmission lines

8DJH 36 Prepared for all requirements

8DJH 36 Prepared for all requirements

Windfarms secure the energy supply in the future

One switchgear for all requirements 8DJH 36 is a gas-insulated modular switchgear with high reliability for your distribution applications up to 36kV and 630A.

One switchgear for all requirements 8DJH 36 is a gas-insulated switchgear with a compact design which fits in the tower of wind turbines 8DJH 36 climatic independence enables worldwide application

8DJH 36 is the newest chapter of a long story of success

8DJH 36 is the newest chapter of a long story of success More than 30 years ago, Siemens laid the foundation for the gas-insulated medium-voltage switchgear 8DJH 36. It is the logical and consequent extension of the very successful 8DJH switchgear. Practical experience of more than 750,000 installed feeders in the secondary distribution level. More than 120,000 installed switchgear panels in primary distribution

8DJH 36 advantages Compactness Personal safety Maintenance-free design Climatic independence Modular construction

8DJH 36 today s answer to the questions of tomorrow

Main applications for 8DJH 36

8DJH 36: A reliable all-rounder 8DJH 36 is the ideal solution for today s and tomorrow s requirements in power distribution.

Overview Applications: substations customer transfer substations distribution and switching substations Users: power supply bureau public utilities public buildings (e.g. high-rise buildings, railway stations, hospitals) Industrial plants

Gas-insulated switchgear: our values

Technical Features Up to 36 kv, 20 ka/ 3 s Busbar 630 A, feeders up to 630 A Factory assembled, type tested switchgear acc. to IEC 62271-200 Metal-enclosed Single busbar Gas-insulated, sealed for life Flexible due to extension option and block formation Individual panels and block versions

Main Power Circuit Technical Concepts for Switchgears

Main Power Circuit Overview Infeed panel Generator Main power circuit (Converter ) Transformer 20 kv Transformer

Generator & Converter: Concepts Fixed Rotor Speed Variable Rotor Speed Gear ASG Directly coupled induction (asynchronous) generator Gear ASG ~ ~ Doubly fed induction generator (DFIG) Gear ASG ~ ~ Induction generator with full inverter system Gear SG ~ ~ Synchronous generator with full inverter system

Doubly fed induction generator (DFIG) Contactor Circuit Breaker Examples 2 Contactors 3RT14, each 690 A * 1,8 (Derating) = 1.200 A 1,6 MW Turbine 3 Contactors 3RT14, each 690 A * 2,5 (Derating) = 1.700 A 2,4 MW Turbine 3 Contactors 3TF69, each 910 A * 2,5 (Derating) = 2.300 A 3,0 MW Turbine Contactors are used parallel at 690V and AC1 Components Details

Full inverter system Circuit Breaker (non-automatic) Converter (sometimes several modules parallel) Contactor Circuit Breaker Examples 3 Contactors 3RT14, each 690 A * 2,5 (Derating) = 1.700 A 1,2 MW per Converter module 3 Contactors 3TF69, each 910 A * 2,5 (Derating) = 2.300 A 1,6 MW per Converter module Contactors are used parallel at 690V, AC1 [Details see at slide before (DFIG)]