Corrosion detection and measurement improvement using advanced ultrasonic tools

Similar documents
Measurement of Residual Thickness in Case of Corrosion Close to the Welds with an Adaptive Total Focusing Method

ULTRASONIC NONDESTRUCTIVE TESTING OF COMPLEX COMPONENTS WITH FLEXIBLE PHASED-ARRAY TRANSDUCERS

Applications of Phased Array Techniques to NDT of Industrial Structures

PORTABLE PHASED-ARRAY ULTRASOUND FULL-FEATURED SYSTEM

High Resolution Phased Array Imaging using the Total Focusing Method

M2M GEKKO. State-of-the-art phased-array flaw detector with TFM

VALIDATION OF THE SIMULATION SOFTWARE CIVA UT IN SEPARATED TRANSMIT/RECEIVE CONFIGURATIONS

UT phased array inspection of turbines

Fast total focusing method for ultrasonic imaging

High Resolution Phased Array Imaging using the Total Focusing Method

Phased-array applications for aircraft maintenance: fastener-hole inspection

REAL-TIME ADAPTIVE IMAGING FOR ULTRASONIC NONDESTRUCTIVE TESTING OF STRUCTURES WITH IRREGULAR SHAPES

A FLEXIBLE PHASED ARRAY TRANSDUCER FOR CONTACT EXAMINATION OF COMPONENTS WITH COMPLEX GEOMETRY

NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE

NEW FEATURES FOR PHASED ARRAY TECHNIQUES INSPECTIONS : SIMULATION AND EXPERIMENTS

Advanced ultrasonic 2D Phased-array probes

ULTRAVISION 3.7R21. Product Bulletin. UltraVision, a complete UT and Phased Array inspection package!

Developments in Ultrasonic Phased Array Inspection III

Sizing and evaluation of planar defects based on Surface Diffracted Signal Loss technique by ultrasonic phased array

ARIA Software. Total Focusing Method. - Real-Time TFM Imaging - Acquire all FMC data - FMC/TFM Wizard - TFM Viewer - Analysis Mode

Validation of aspects of BeamTool

SIZING THE HEIGHT OF DISCONTINUITIES, THEIR CHARACTERISATION IN PLANAR / VOLUMETRIC BY PHASED ARRAY TECHNIQUE BASED ON DIFFRACTED ECHOES

Advanced Ultrasonic 2D Phased-Array Probes

ADVANCED PHASED ARRAY TECHNOLOGIES

Development of a robotic nozzle inspection with a flexible transducer array

UMASIS, an analysis and visualization tool for developing and optimizing ultrasonic inspection techniques

MANTIS Compact Phased Array Ultrasonic (PAUT) Flaw Detector featuring TFM, TOFD and Conventional UT

Research on Correction and Optimization of Post-processing Imaging of Structure with Non-planar Interface Using Full Matrix Data of Ultrasonic Array

RECENT MODELLING ADVANCES FOR ULTRASONIC TOFD INSPECTIONS

APPLICATION OF ULTRASONIC BEAM MODELING TO PHASED ARRAY

DEVELOPMENT AND VALIDATION OF A FULL MATRIX CAPTURE SOLUTION. Patrick Tremblay, Daniel Richard ZETEC, Canada

Plane Wave Imaging Using Phased Array Arno Volker 1

Robot-Based Solutions for NDT Inspections: Integration of Laser Ultrasonics and Air Coupled Ultrasounds for Aeronautical Components

Real-time full matrix capture with auto-focussing of known geometry through dual layered media

Application of the Total Focusing Method for Improved Defect Characterization in the Production of Steel Tubes, Pipes and Plates

Probability of Detection Simulations for Ultrasonic Pulse-echo Testing

Simulation platform for NDE

GENERIC GTD-KIRCHHOFF SCATTERING MODEL FOR THE ULTRASONIC RESPONSE OF PLANAR DEFECTS

INSPECTION USING SHEAR WAVE TIME OF FLIGHT DIFFRACTION (S-TOFD) TECHNIQUE

Simulation in NDT. Online Workshop in in September Software Tools for the Design of Phased Array UT Inspection Techniques

Developments in Ultrasonic Phased Array Inspection IV

UMASIS, AN ANALYSIS AND VISUALIZATION TOOL FOR DEVELOPING AND OPTIMIZING ULTRASONIC INSPECTION TECHNIQUES

RECONSTRUCTION OF PHASED ARRAY TECHNIQUES FROM THE FULL MATRIX CAPTURE DATA SET

Automatic analysis and weld indications classification on TFM acquisitions

SAFT-Reconstruction in ultrasonic immersion technique using phased array transducers

Phased Array Assisted Manual Nozzle Inspection Solution with Data Archiving Capability

GPU ACCELERATED TOTAL FOCUSING METHOD IN CIVA

Full-Matrix Capture with a Customizable Phased Array Instrument

SIMULATION OF THE UT INSPECTION OF PLANAR DEFECTS USING A GENERIC GTD-KIRCHHOFF APPROACH

Influence of Stress Corrosion Crack Morphology on Ultrasonic Examination Performances

Adaptive Focusing Technology for the Inspection of Variable Geometry. Composite Material

Ultrasonic Multi-Skip Tomography for Pipe Inspection

ULTRASONIC TESTING AND FLAW CHARACTERIZATION. Alex KARPELSON Kinectrics Inc., Toronto, Canada

Developments in Ultrasonic Phased Array Inspection II

Applications Group; Zetec, zndt Solutions, Québec; Phone: ;

HUMAN FACTOR IMPROVEMENT IN NDE WITH FMC IMAGING METHODS

Recent advances in aerospace inspection with ultrasonic phased arrays

Comparison Corrosion Mapping Solutions using Phased Array and Conventional UT Techniques

A Study of Time-of-Flight Diffraction Technique Using Photoelastic Visualisation

True Advancements for Longitudinal Weld Pipe Inspection in PA

June 16-18, Toronto, Ontario

Recent achievements in sizing and characterization of weld defects with Pulse echo, TOFD and Phased Array in the frame of ASME and EN standards

Ultrasound Phased Array Imaging on Curved Surface for Weld Inspection of Elbow Pipe as a Replacement for Radiographic Inspection

EXPERIMENTAL VALIDATION OF AN 8 ELEMENT EMAT PHASED ARRAY PROBE FOR LONGITUDINAL WAVE GENERATION

Simulation of NDT Inspection in 3D Elastic Waveguide Involving Arbitrary Defect

Plane Wave Imaging for ultrasonic non-destructive testing: Generalization to multimodal imaging

Application of a 3D Laser Inspection Method for Surface Corrosion on a Spherical Pressure Vessel

John R. Mandeville Senior Consultant NDICS, Norwich, CT Jesse A. Skramstad President - NDT Solutions Inc., New Richmond, WI

Robot-based real-time ultrasonic tomography for industrial NDT applications

Comparison Corrosion Mapping Solutions using Phased Array, Conventional UT and 3D scanners

MULTI-MODE TFM IMAGING WITH ARTEFACT FILTERING USING CIVA UT FORWARD MODELS

Evaluation of the imaging performance of a CFRP-adapted TFM algorithm

Influence of seamless pipes wall thickness variation for the effectiveness of Automated Ultrasonic Testing

Developing an Ultrasonic NDE System for a Research Reactor Tank

(Part ##) SWA

UltraVision TOUCH 3.8R11

NDE Inspection FMC and TFM

Sizing in Phased Array Technique using Diffraction and Amplitude Displacement

Mentor UT. The power of ultrasonic phased array inspection meets everyday use. gemeasurement.com

Ultrasonic imaging of steel-adhesive and aluminum-adhesive joints using two dimensional array

Vajira Jayasinghe, Chris Eaton, & Brian Millejours. Application of Flexible PAUT probes for small diameter FAC elbow inspection II

Minimize your cost for Phased Array and TOFD

Use of Water Immersion UT techniques to assist with data capture and analysis. Dr. N. R. Pearson (Speaker), S. Marshall, M. Kircough, W.

Enhanced Defect Detection and Characterisation by Signal Processing of Ultrasonic Array Data

SAFT DATA PROCESSING APPLIED TO LASER-ULTRASONIC INSPECTION

Imaging the Weld Volume Via the Total Focus Method. Ray TEN GROTENHUIS, Andrew. HONG, Ontario Power Generation Inc., Canada

ULTRAVISION 3.8R13. Technical Guidelines. UltraVision, a complete UT and Phased Array inspection package!

KAUNAS UNIVERSITY OF TECHNOLOGY DETERMINATION OF POSITION OF DEFECTS IN RAILS USING ULTRASONIC PHASED ARRAYS

High-End Ultrasonic Phased-Array System for Automatic Inspections

PRISMA SERIES AS SIMPLE AS YOU WANT AS CAPABLE AS YOU NEED STEP UP FROM CONVENTIONAL UT TO PHASED ARRAY. Ultrasonic Phased Array Flaw Detector Series

QUALIFICATION OF A BUTT-WELD INSPECTION USING PHASED ARRAY IN LIEU OF RADIOGRAPHY

SHEAR WAVE WEDGE FOR LASER ULTRASONICS INTRODUCTION

A THREE-DIMENSIONAL PHASED ARRAY ULTRASONIC TESTING TECHNIQUE

Simulation of ultrasonic guided wave inspection in CIVA software platform

Next Generation Technology for Pipeline AUT TFM/FMC

Modelling I SPECIFIC REQUIREMENTS ON COMPUTER MODELING OF RADIOGRAPHIC INSPECTIONS OF NUCLEAR COMPONENTS

Phased Array inspection system applied to complex geometry Carbon Fibre Reinforced Polymer parts

RA Y -MODELING FOR COMPUTER SIMULATION OF ULTRASONIC TESTING

ADVANCED ULTRASOUND WAVEFORM ANALYSIS PACKAGE FOR MANUFACTURING AND IN-SERVICE USE R. A Smith, QinetiQ Ltd, Farnborough, GU14 0LX, UK.

TOPAZ 32 FULLY INTEGRATED PHASED ARRAY UT DEVICE WITH MULTI-TOUCH SCREEN PERFORMANCE AND PRODUCTIVITY REDEFINED

Transcription:

19 th World Conference on Non-Destructive Testing 2016 Corrosion detection and measurement improvement using advanced ultrasonic tools Laurent LE BER 1, Grégoire BENOIST 1, Pascal DAINELLI 2 1 M2M-NDT, Les Ulis, France 2 Institut de Soudure Industrie, Villepinte, France Contact e-mail: l.leber@m2m-ndt.com, p.dainelli@isgroupe.com Abstract. Accurate and reliable ultrasonic measurements on corroded areas still remain a challenge. In some cases, the accurate residual thickness measurement can be very difficult to achieve: strong corrosion, fast variation of thicknesses, shallow pits... Total Focusing Method (TFM) has been recently made available in portable Phased-Array Ultrasonic Instrument. Portable industrial equipment with full-parallel capabilities allows handling of matrix-array probes, 3D imaging and advanced techniques for optimal focusing. In the case of 2D corrosion mapping, the Total Focusing Method presents some advantages in comparison with standard Electronic scanning: limitation of the dead zone, improvement of the accuracy, detection and visualization of slopes between areas parallel to the surface. Advantages and drawback of the methods are discussed, and performances are shown on strongly corroded pipes. Introduction Corrosion measurements represent a major application of ultrasonic inspections. In addition to the usual thickness measurement with single or dual element probes, full corrosion mapping is more and more demanded by end-users to ensure that an eventual corrosion degradation process is not missed by a point like measurement technique. Corrosion mapping has led to significant improvements in this topic where proof of coverage, always the biggest issue with thickness testing, can be easily demonstrated through a Cscan image. Phased array techniques have been extensively used for several years demonstrating its capability to cover large corroded area and providing a good mapping resolution (typical resolution is mm). Recently, advanced processors and advanced computation capabilities made possible techniques such as Full Matrix Captures and Total Focusing Methods in real time and within portable equipments. These new techniques are now available in the corrosion mapping market and the advantages of these technics are discussed in this paper. License: http://creativecommons.org/licenses/by-nd/3.0/ 1 More info about this article: http://ndt.net/?id=19240

1. Phased array and corrosion mapping Phased arrays have been extensively associated to corrosion mapping since it has the capability of full coverage thanks to their electronic scanning capabilities. Thickness gages are providing punctual measurements. They are providing an idea on the corrosion but make unrealistic the extension to a 100% full coverage. For example a rather small area of 100mm by 100mm with a grid of 1mm measurement step (10 000 measurements) requires 2.7 hours to be fully covered assuming one second per measurement. In phased array corrosion mapping, the same area can be covered in a few seconds [1]. Nowadays, most of the corrosion mapping inspections are performed using electronic scanning and few are combining electronic scanning and angular scanning as described later in this paper. 1.1 Electronic scanning and corrosion mapping In electronic scanning mode, a group of elements of a phased array is activated and electronically moved along the phased array probe. The probe is then, mechanically moved perpendicularly to the electronic scanning direction and a C-scan view can be produced at a high inspection speed. A typical configuration corrosion mapping configuration managed with a 5MHz phased array probe, 64 elements, with a pitch of 0.6mm placed on a 10mm Rexolite wedge. For a typical 10 khz pulse repetition frequency (PRF), the electronic scanning speed is 6m/s (21 km/h). Replacing this electronic displacement by hand probe motion is in the field not feasible. This explains the success of corrosion mapping with phased array. In addition, at a single probe position, this inspection provides a high resolution description of the back wall as thickness measurements can be provided by the phased-array at 57 positions assuming an aperture of 8 elements without moving the probe. A result of a simulated corroded area case study of is shown in the following figure. 57 pixels speed of 6m/s Fig. 1. Electronic Bscan of a corroded area at one specific position (simulation through CIVA software) Another advantage of corrosion mapping with phased array is their capability to provide Cscan pictures in real time. Again, proof of coverage can be easily demonstrated through a Cscan image: 2

Fig. 2. Experimental setup of a heavily corroded pipe (top picture) picture of an heavily corroded area (left bottom picture) Experimental amplitude Cscan of the heavily corroded area (bottom right picture) 1.2 Electronic and sector scan merged for a better mapping The previous Electronic scanning method is widely used but can sometimes missed measurement spots. This is typically the case for important corrosion where back wall slopes are presents. The next figure presents a simulated electronic scanning image superimposed with the back wall (represented by the black line). The important slope relatively to the surface echo tends to decrease the level of the back wall echo to an extent where some thickness can barely be extracted from these pictures. Safety considerations could assume the worst case scenario (i.e. through all corrosion) and lead to drastically anticipated shut down of still operational components [2]. 3

Surface signal Missed backwall through all corrosion? Fig. 3. Potential missed spots of an Electronic scanning (simulation) In some heavy corroded applications, electronic scanning and sector scan are sometimes merged to decrease the sensitivity to sloped back walls. Even if missed thickness measurement spots can still be observed, this technique greatly decrease missed measurement spots. In the next example, an electronic scanning is performed and for each aperture, a sector scan of -20, 0 and 20 is performed. Electronic scanning Electronic scanning Sector scan : -20 ;0 ; +20 Sector scan : -20 ;0 ; +20 Fig. 4. Electronic scanning merged with sector scan The combination (or merge) of these Electronic scanning and Sector scanning creates a better description of the back wall. Of course, as 3 shots are performed for each aperture, the inspection speed is divided by 3 compared to a simple electronic scanning. Fig. 5. Merged Electronic and Sector scanning (simulation) 4

2. Total focusing Method and corrosion mapping The relatively new Total Focusing Technique has been recently made available in real time in the Gekko field portable equipment. TFM is applied to a dataset recorded from a FMC (Full Matrix Capture) acquisition to produce an image in a region of the component [3]. The FMC presents the advantage of maximizing the information available from a given array composed of N elements by sending ultrasonic energy everywhere in the component; this way potential defects can be seen from multiple directions and, in particular, is able to improve the detection of sloped back wall [4]. The FMC acquisition consists in firing each element of the array in turn and recording the information reflected/diffracted in the component on all the elements. The result of the FMC is a NxN dataset composed of every emitter-receiver pair combination of elements in the array. The TFM algorithm consists in coherently summing all the signals s ij (t) from the dataset to focus at every points of a Region Of Interest (ROI) in a specimen. TFM is performed in the Gekko equipment at a rate of 27 pictures per second. This is a bit slower than an electronic scanning inspection but still consistent with a manual inspection. Despite this slight speed decrease, the ROI size is at the moment a 256x256 pixel zone providing an extremely better resolution than Electronic scanning (cf. Figure 2 where only 57 pixels are available). An example of TFM picture is provided below on the same corroded area showing a great improvement for heavily corroded areas. 256 pixels 256 pixels Fig. 6. Merge Electronic and Sector scanning (simulation) Potential advantages of TFM versus electronic scanning and electronic + sector scan are discussed in the next paragraphs. 3. Discussion on the advantages of TFM with simulated data In the next example, a back wall containing a triangular shape is taken as a synthetic example of corrosion. CIVA simulation software has been used to compute and accurately compare the different techniques (electronic scanning, electronic and merged sector scan, TFM). The simulated mock-up is a 9mm thick pipe with a corroded area which has the shape of a triangle. 5

9 mm 5.5 mm 35 10mm Fig. 7. Geometric description of the triangular shape 3.1 Linear scan When the corrosion mapping is operated through a linear scan, the diffraction from the top of the triangle can barely be seen. The 35 slopes are not visible as it can be observed in the figure below: Fig. 8. Electronic scanning of triangular shaped corrosion (simulation) 3.2 Linear scan and merged sector scan (-20, 0, 20 ): When the corrosion mapping is operated through a merge of linear and sector scan, the slopes can be detected thanks to the -20, 20 shots and the top of the triangle as well thanks to diffraction effect. But the detection is still extremely weak as one can see the relatively small amplitude of the defected areas compared to the back wall echo. Fig. 9. Merged Electronic and Sector scan of triangle shaped corrosion (simulation) 6

3.3 TFM reconstruction of FMC The next example shows the results of corrosion mapping operated through FMC and TFM process. The advantage of TFM is clearly visible in the B-scan view (see figure below), as slopes are very well reconstructed. Fig. 10. TFM reconstruction (simulation) This can be explained by the FMC acquisition scheme where the elements are fired one by one. Phased array elements are usually very small (pitch of 0.6mm in this example). Thus, the acoustic energy they radiate is very divergent: the almost spherical wave propagation increases the slopes reflectivity and enhances the TFM reconstruction. The same FMC acquisition scheme can explain a better sub-surface resolution of TFM compared to electronic scanning. In Electronic scanning, the group of emitting elements are producing a planar wave on the surface and thus, a very large surface echo, when the very divergent wave fronts created by small elements are weakening the surface echo and reduce its length. 3.4 Experimental results The next table shows some experimental TFM examples which are compared to Electronic scanning on heavily corroded pipe (nominal thickness is 9mm but, for position 2 below, the remaining thickness is less than 1.5mm). Left column are the TFM results, right column are the electronic scanning. Each line of the table represents the two methods (TFM and Escan) shown at the same position of the probe for comparison. TFM : position 1 Electronic scanning : position 1 TFM : position 2 Electronic scanning : position 2 7

TFM : position 3 Electronic scanning : position 3 Fig. 11. Comparison between TFM (left column) and Electronic scanning (right column) at the same position (each line is at the same position of the probe). The TFM results show a great amelioration of the back wall detection thank to a greatly enhanced resolution (from 57 to 256 horizontal pixels). By sending energy everywhere it is possible to detect the various orientations of the back wall and thus reconstruct the corroded surface more accurately. Moreover, the dead zone is also reduced from 1.5 to 0.5 mm thanks to the FMC acquisition (see position 2). Conclusions Recently, portable phased-array systems with TFM capabilities have been made available. The few results presented leads to the fact that Cscan imaging is enhanced by real time TFM processing. The improvements deal with higher resolution and sensitivity to shallow pit, reduction of dead zone, and visualisation of misoriented corrosion profiles. Implementing Total Focusing Method on the field for corrosion mapping is even simpler than operating a conventional linear scan from the NDT technician point of view. The ultrasound settings are easier; the acquisition speed is compatible with hand scanning speed. In addition the results obtained with TFM that reveals more realistically the corrosion profiles, avoid sometime additional work. The quality of the corrosion profiles reconstruction could be enough to take the right decision from an engineering or inspection point of view without involving other UT techniques like TOFD, phased-array shear waves sectorial scan References [1] A. McLay, F. Gabriels, Increase in reliability in advanced ultrasonic inspection methods, proceedings of the MENDT 2009 conference. http://www.ndt.net/article/mendt2009/papers/ramzi-beidas-increased-1.pdf [2] C. Schneider, Application of Extreme Value Analysis to Corrosion Mapping Data, 4th European- American Workshop on Reliability of NDE, ref. We.2.A., http://www.ndt.net/article/reliability2009/inhalt/we2a3.pdf [3] C. Holmes, B. W. Drinkwater, Paul D. Wilcox, Post-processing of the full matrix of ultrasonic transmitreceive array data for non-destructive evaluation, NDT&E International, Vol 38, pp 701-711, 2005 [4] Fidahoussen, P. Calmon, M. Lambert, S. Paillard, S. Chatillon, Imaging of defects in several complex configurations by simulation-helped processing of ultrasonic array data, Review of progress in QNDE, Vol. 29, pp. 847-854, 2009 8