C1950 (STLR & HTST) Pasteurizer Recorder and Recorder Controller

Similar documents
ABB MEASUREMENT & ANALYTICS DATA SHEET. C1950 (STLR & HTST) Pasteurizer recorder and recorder / controller

Pasteurizer Recorder and Recorder Controller

ControlMaster CMF160 Universal process indicator, fieldmount

ControlMaster CMF160 Universal process indicator, fieldmount

Control IT Booster Pump Controller

FICHA TÉCNICA DE PRODUTO

C160 Wall-/Pipe Mounted Universal Process Indicator

Inform IT Single Pen Circular Chart Recorder

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument

C1900 Series Circular Chart Recorder. C1900 a rugged, reliable recorder with the full capability to meet your needs

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1300 Advanced circular chart recorder

FICHA TÉCNICA DE PRODUTO

ControlMaster CM10, CM30, CM50 and CM15 Universal process controllers and indicator Spare parts

/8 DIN Motorized Valve Controller

Inform IT Circular Chart Recorder/ Controller

Introduction. For more information. HART Protocol 7.0 Valid for software levels from 05.00

/8 DIN Universal Process Indicator

ControlMaster CM15, CM30 and CM50 Universal process indicator and controllers Customizing the operator page displays

Wall-/Pipe Mounted Universal Process Indicator

100mm Process Indicator Recorder

Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart

SM2000 Videographic recorder Spare parts and upgrade kits

ABB MEASUREMENT & ANALYTICS DATA SHEET. DataManager Pro RDM500 Advanced data review software

SM1000 Videographic recorder Spare parts and upgrade kits

Commander circular chart recorders The tried and tested solution for process recording

CoriolisMaster mass flowmeter Automation solution for mixing applications

ControlMaster PC Configuration

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

ALM CHN RSP OUT F SP 164.8

Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart

ControlMaster controllers and indicators ConfigPilot

Adapter Plates for continuous Part-Turn Actuators (Contrac)

Using the WirelessHART transmitter TTF300-W as repeater to extend the availability of a WirelessHART network

ABB MEASUREMENT & ANALYTICS DATA SHEET. Testomat AW101 Water hardness monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET. DataManager Pro RDM500 Advanced data review software

ControlMaster CMF160 Universal process indicator, fieldmount

Digital Indicator DS 48/24 E

ControlMaster CM15 Universal process indicator, 1 /8 DIN. Making process control easy

Crane-Boy / Crane-BoyP Load limitation electronics

Recorders for all applications

AV-9900 Field Setup Guide

MagMaster Electromagnetic flowmeter. MagMaster to WaterMaster electronics upgrade. Introduction

C /4 DIN Multi-Recipe Profile Controller. C360 a comprehensive profile controller for all ramp/ soak applications

ScreenMaster series Paperless recorders

Universal Process Controller

ABB Instrumentation. Specification DataFile. COMMANDER 1900 a rugged, reliable recorder with the full capability to meet your application needs

INDI BOY DSP Load limitation electronics

ControlMaster CM10 Universal process controller, 1 /8 DIN. Making process control easy

Control IT. /16 DIN Controller/Alarm Unit. Data Sheet SS/C50_7 C50. C50 the 1 /16 DIN controller to suit your simplest applications

8241 Silica Monitor. Cost-effective automated monitoring of silica in a wide range of applications

C1900 Circular chart recorder and recorder/controller

ABB Instrumentation. Installation Guide. COMMANDER 1900 Series Circular Chart Recorders. All Versions !50.8 degf OP

TEPI11 P/I signal converter

LineMaster 100 Continuous-line Recorder

Indicomp 4 Bargraph Indicator

Installation Guide. COMMANDER 1900 Series Circular Chart Recorders. All Versions !50.8 degf OP

ControlIT Process controller

SwirlMaster The new generation of swirl flowmeters

Videographic Recorders

User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6. /8 DIN Process Indicators and Controllers C100, C150, C160 and V100

Cornell Dairy Foods Extension Program Syllabus High Temperature Short Time (HTST) Workshop

FICHA TÉCNICA DE PRODUTO

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250

Navigator 540. Measurement made easy. Introduction. For more information

ABB MEASUREMENT & ANALYTICS DATA SHEET. DAT200 Asset Vision Basic and DTM Device Typ Manager

ABB Instrumentation. Specifications. COMMANDER 505 Advanced Process Controller

250mm Advanced Process Recorder

ABB MEASUREMENT & ANALYTICS DATA SHEET. Navigator 600 Phosphate Phosphate analyzer

ABB MEASUREMENT & ANALYTICS DATA SHEET. ControlMaster CM10 Universal process controller, 1/8 DIN

Inform IT 250mm Multipoint Strip Chart Recorder

LineMaster 200 Continuous-line Recorder

ABB i-bus KNX HCC/S Heating/cooling circuit controller

4-step Chiller and Heat Pump Controller

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

ABB Control Technologies. ABB ScreenMaster paperless recorders Versatile recording anywhere

ABB i-bus KNX BCI/S Boiler/Chiller Interface

ABB MEASUREMENT & ANALYTICS DATA SHEET. IT1 Universal weighing terminal

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Accessories for pluggable interface relays CR-P, CR-M Pluggable function module

LME620-AI/-AN (Contrac) Electrical Linear Actuator

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Accessories for pluggable interface relays CR-U Pluggable function modules

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB84PH ph /ORP / pion transmitter

How to connect ABB Ethernet inverters with VSN700 Data Logger over Ethernet

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

Bus Connection Unit 560BCU04

ScreenMaster RVG200 Paperless recorder

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Navigator 600 Phosphate Phosphate analyzer. Cost-effective automated monitoring of phosphate for steam raising applications

INFORMATION. SM Series Videographic Recorders PC Emulator Quick Start Guide. 1 Emulation Tips. Manual IM/SM500F, IM/SM1000, IM/SM2000, IM/SM3000

Spare Parts, Upgrade Kits and Service Kits for SM1000 and SM2000 Videographic Recorders

2600T Series Pressure Transmitters How to replace Profibus PA pressure transmitters with the 266 PA

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

/2 DIN Advanced Process Controller

Installation and Operation Manual SPC1

VeriMaster. Software tools. Measurement made easy. Overview

INFORMATION. Guidance on the use of the SM1000 and SM2000 Videographic Recorders for Electronic Record Keeping in FDA Approved Processes

Transcription:

Data sheet DS/C1950 EN Rev. K C1950 (STLR & HTST) The complete recording and control solution for pasteurization processes Dedicated Pasteurizer Recorder/Controller designed to meet requirements of the pasteurization processes High clarity digital displays continuous indication of hot product and divert temperature Compliance review meets PMO requirements Pasteurizer status indicator LED indication to show forward or diverted flow True time event pen 4-position event, records divert and forward flow plus optional CIP (clean in process) and secondary divert Up to eight diversion set points local or remote selection of hot product divert temperature settings Hot product pen calibration optimization of pen reading to independent thermometer Second resistance thermometer option allows checking for sensor error and gives additional alarm/ divert protection

Introduction The C1951 recorder and 1952/1953 recorder/controllers have been designed specifically for pasteurization applications. The Model C1951 records the hot product temperature and either divert set point or cold product temperature. Model C1952 is a recorder/controller, recording hot product and either divert set point or cold product temperature and controlling hot water temperature. Model C1953 is the top of the range recorder/controller, combining all the capabilities of the C1952 with cold water temperature control from the cold product temperature probe. All versions are fitted with a 4-position true time event pen which indicates forward flow, divert, CIP and secondary divert (if required) via a digital input from valves etc. The C1951 model has eight diversion set points to activate the event pen. The C1952/1953 models have eight pairs of diversion and hot water set points for the controller and event pen. On the C1952/1953 versions the multiple divert/hot water set points can be used to preset sterilizing and CIP temperature to enable remote selection of these functions from the customer?s control panel. All models are fully password protected and can be sealed, as required by the FDA. The C1950 series recorder is a totally self-contained unit suitable for panel, wall or post mounting. As standard, the case is rated NEMA4X (IP66), making it suitable for use in almost any location in a modern dairy where cleaning of all surfaces takes place. 2 DS/C1950 EN Rev. K

Benefits C1951 C1952 C1953 DISPLAY Flow/Divert Status Hot Product Temperature Divert Temperature Cold Product Temperature Heating Loop PV & SP Cooling Loop PV Auxiliary Input RECORDING Hot Product Divert Set Point or Cold Product (option on 1952) Auxiliary Input (optional) Flow/Divert/CIP Status (True Time event pen) Red Green (Blue) Violet Red Green (Blue) Violet Red Green Blue Violet CONTROL Heating Loop Cooling Loop = Standard = Optional Red Pen (1) Hot Product Green Pen (2) Select (None), Divert Set Point or Cold Product Blue Pen (3) Trace for auxiliary input only (display available on C1951) Optional auxiliary input for pressure, second RTD, Flow etc. traced but not displayed (C1952/C1953) Violet Pen 4-Position True Time Forward/Divert Event Hot Water Measurement and Control (No Recording) Cold Product (Measurement and Control) Hot Product (Recording) Divert Temperature C1953 Control Faceplate Control Faceplate Dairy/Pasteurizer Faceplate Hot Water Measurement and Control (No Recording) Forward Flow LED Indicator Hot Product (Recording) Divert Temperature C1952 Green Amber Red FWD DVT Hot product (Recording) Divert Temperature Control Faceplate Dairy/Pasteurizer Faceplate Select Display Options Cold 2nd HP Blank Product RTD Units Blank Aux. 1st-2nd DT Blank RTD Units C1951 Divert Flow LED Indicator Dairy/Pasteurizer Faceplate Record Faceplate HP = Hot product DT = Divert Temperature Aux. = Auxiliary Input DS/C1950 EN Rev. K 3

Principle of Operation Pasteurization Raw product is pumped from the constant level tank to the heating section where the temperature is raised to exceed the pasteurization low limit. The hot product temperature is measured and recorded at the end of the holding tube. Until the pasteurization limit is exceeded, the product is recycled to the constant level tank by the FDD. Once pasteurization temperature is exceeded, the hot product, through the forward flow port, is routed to the regenerator and cooling sections of the heat exchanger. The red pen records and monitors the hot product pasteurization temperature. The violet pen records the position of the flow diversion valve, FDD. Both of these pens record on the same time line. The green pen records the selected diversion temperature, on multiple divert systems, where up to eight may be selected. The event pen can also indicate when the process is in CIP or secondary divert due to low pressure. C1900 High Temperature Short Time Controller (HTST) Meter-based Timing System * C1900 Flow Recorder Controller MagMaster Transmitter I P Steam Hot Water Flow Diversion Devices RTD Heater RTD PASTEURIZED PRODUCT OUT RTD Variable Speed Timing Pump Holding Tube Cold Water Supply Cooler Regen. Leak Detect Line Divert Line Sanitary MagMaster Flow Meter Check Valve or Control Valve (for Pneumatic Systems) COMANDER320 Booster Pump Pressure Switch Booster Pump Constant Level Tank RAW PRODUCT IN 4 DS/C1950 EN Rev. K

Meter-based Timing System * The MagMaster Flowmeter measures flow rate and sends the signal to the C1900 Controller. In turn, the C1900 regulates the flow by throttling the variable speed timing pump based on the comparison of product flow rate to the C1900?s set point. The maximum set point is the volumetric flow rate that provides the minimum necessary pasteurization time in the holding tube. As a safeguard in the system setup, the C1900 provides alarms for high and low flow and loss of signal. These alarms notify operators when conditions, such as loss of flow, power failure, damaged cable or similar situations arise. When triggered, the integral alarm relay changes state, causing the flow diversion valve to move to its divert position until the condition is corrected and the time delay has expired. * For additional information on the Meter-based Timing System contact your local ABB representative. DS/C1950 EN Rev. K 5

Ordering Information PART 1 General Details C1950 (STLR & HTST) XXXXX X X X X X X 0 X X X XXX Safety Thermal Limit Recorder (STLR) 2 pens (red and green) plus true time event pen (violet) Taylor (ER/C) charts KPC 105, Kent PX and Kent PXR type charts High Temperature Short Time (HTST) Recording Controllers 1 control unit, 2 pens (red and green), plus true time event (violet) Taylor (ER/C) charts KPC 105, Kent PX and Kent PXR type charts 2 control units, 3 pens (red, green and blue), plus true time event pen (violet) Taylor (ER/C) charts KPC 105, Kent PX and Kent PXR type charts 1951J 1951K 1952R 1952S 1953R 1953S Electrical Code Standard A CSA approved* B UL approved U Additional Modules None 0 Additional modules Part 2 A Options None 0 Door Lock Not fitted Fitted Power Supply 115V AC 230V AC * CSA approval is not available on units with module type '9' fitted see below 1 2 1 2 PART 2 Modules XXXXX X X X X X X 0 X X X XXX Module Position 2* 1952 Enter code 1 for optional cold product module 1951 and 1953 Enter code 0 cold product module always fitted 0 1 Module Position 3* 1952 and 1953 Enter code 0, hot water module always fitted 1951 No option permitted 0 Module Position 4 Enter code 1 or 2 for auxiliary input module For other options see key below 0 1 2 3 4 5 Module Position 5 Enter option 9 for FDA dairy applications (115V only) 0 2 3 4 9 For other options see key below Module Position 6 If option 9 is selected above, no other option is permitted 0 2 4 5 8 Programming/Special Features Configured to factory standard Configured to customer requirements Special features STD CUS SXX 6 DS/C1950 EN Rev. K

Key to Module Types *0 No module fitted / Pen input channel 4 8 Digital Inputs 1 Standard Input/Output 5 8 Digital Outputs 2 Analog Input (Remote set point + Relay 8 Modbus RS485 Communications 3 4 Relays 9 Dairy Module (FDA) (takes up module positions 5 and 6) For full technical specifications refer to Data Sheets DS/C1900R & DS/C1900RC DS/C1950 EN Rev. K 7

Contact us ABB Limited Process Automation Howard Road St. Neots Cambridgeshire PE19 8EU UK Tel: +44 (0)1480 475321 Fax: +44 (0)1480 217948 ABB Inc. Process Automation 125 E. County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2011 ABB All rights reserved 3KXR200106R1001 Modbus is a trademark of Modicon, Inc. DS/C1950 EN Rev. K 04.2011 www.abb.com