IMC-21A Quick Installation Guide

Similar documents
IMC-21 Quick Installation Guide

IMC-21GA Quick Installation Guide

MOXA Industrial Media Converter

PTC-101-M12 Hardware Installation Guide

PTC-101 Quick Installation Guide

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

IMC-101 Series Quick Installation Guide

EDS-P206A-4PoE Series Hardware Installation Guide

EDS-G205A-4PoE Hardware Installation Guide

EDS-210A Quick Installation Guide

EDS-210A Series Hardware Installation Guide

MOXA EtherDevice Switch EDS-205 Hardware Installation Guide

EDS-G308 Series Quick Installation Guide

EDR-G902/G903 Quick Installation Guide

EDS-P206A-4PoE Series Quick Installation Guide

TN-5308 Quick Installation Guide

Moxa Industrial Media Converter

EDS-G205-1GTXSFP Quick Installation Guide

Moxa Industrial Media Converter

INJ-24A Series Quick Installation Guide

EDS-G205A-4PoE Quick Installation Guide

EDS-308/309 Hardware Installation Guide

Hardened 4-Port 10/100/1000M DIN-Rail Mount Switch GATB. User's Manual (V1.0 Version)

MOXA EtherDevice Switch

Moxa ToughNet Switch

EDS-505A/508A Hardware Installation Guide

EDS-405A/408A Series Quick Installation Guide

IMC-101G Series Quick Installation Guide

EDR-810 Series Quick Installation Guide

MOXA EtherDevice Switch & PoE Splitter

EDS-405A-PTP Series Hardware Installation Guide

EDS-205A/208A Series Quick Installation Guide

PT-7728/7828 Quick Installation Guide

IES308-2F. Introduction: Packing List: Features: 8-port Unmanaged Industrial Ethernet Switch Hardware Installation Guide

EDS-P510 Series Quick Installation Guide

MOXA EtherDevice Switch

ICF-1150 Series Quick Installation Guide

CSM-200 Series. Hardware Installation Guide. First Edition, November 2009

EDS-308/309 Series Quick Installation Guide

IES608-2F. Introduction. ntroduction: Packing List. ist: Features:

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

ICF-1150 Series Quick Installation Guide

Industrial Media Converter

Moxa EtherDevice Switch

10 Industrial Media Converters

Ethernet PoE Switch - Premium Line IE-SW-PL06M-2TX-4PoE (Managed)

TCF-142 Quick Installation Guide

EDS-510E Series Hardware Installation Guide

Moxa EtherDevice Switch

PT-G503-PHR-PTP Series Quick Installation Guide

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

EDS-405A/408A Series Quick Installation Guide

RS-422/485 to Fiber Industrial Converter

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

TCF-142-RM Series Hardware Installation Guide

Features and Benefits. Certifications

Industrial Slim Type Fast Ethernet Rail Switch

NPort S8000 Series Quick Installation Guide

Managed Ethernet Switches Value Line

EDS-G500E Series Hardware Installation Guide

IMC-P111FX / IMC-P111P Series

Moxa EtherDevice Switch

Features and Benefits. Certifications

Rugged Industrial Media Converter

UPort TM 200/400 Series Quick Installation Guide

Moxa EtherDevice Switch

imc2 Features Introduction Industrial 2 Port Ethernet to Fiber Converter Tel: Fax:

Industrial Unmanaged Ethernet Switch

imc2f Features Industrial IEC Ethernet to Fiber Media Converter Tel: Fax:

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

IMC-P111FX Series IMC-P111P Series

IKS-G6524A/G6824A Series Quick Installation Guide

EDS-G512E-8PoE Series Hardware Installation Guide

AWK-3121-M12-RTG Quick Installation Guide

EDS-510A Hardware Installation Guide

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

AWK-3191 Quick Installation Guide

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

AWK-1131A Quick Installation Guide

Moxa EtherDevice Switch

AWK-3121-M12-RTG Quick Installation Guide

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

Owner s Manual. Media Converters Models: N SC & N ST

EDS-528E Series Quick Installation Guide

EDS-G512E-8PoE Series Quick Installation Guide

MGate MB3170/MB3270 Quick Installation Guide

NPort 5200 Series Quick Installation Guide

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

ICS-G7526A/G7528A/ G7826A/ G7828A Series Quick Installation Guide

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

8-port 10/100Base-TX Switch (INS-806) User s Guide

Industrial Ethernet Switch

4TX + 1MMFX Unmanaged Ethernet Switch

Transcription:

IMC-21A Quick Installation Guide Moxa Industrial Media Converter Edition 5.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778 Moxa Europe: Tel: +49-89-3 70 03 99-0 Fax: +49-89-3 70 03 99-99 Moxa India: Tel: +91-80-4172-9088 Fax: +91-80-4132-1045 Moxa China (Shanghai office): Toll-free: 800-820-5036 Tel: +86-21-5258-9955 Fax: +86-21-5258-5505 Moxa Asia-Pacific: Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 2017 Moxa Inc. All rights reserved. P/N: 1802000210023 *1802000210023*

Overview The Moxa Industrial Media Converter IMC-21A series consists of entry-level 10/100BaseT(X) to 100BaseFX media converters that provide a cost-effective solution, and are specially designed for reliable and stable operations in harsh industrial environments. NOTE Throughout this Hardware Installation Guide, we use IMC as an abbreviation for Industrial Media Converter: IMC = Industrial Media Converter Package Checklist Moxa s IMC-21A is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance. IMC-21A media converter Quick installation guide (printed) Warranty card Features Power inputs: 12 to 48 VDC The TP port s connection speed, Half/Full-duplex mode and Force/Auto mode are all DIP switch selectable The fiber port s Half/Full-duplex mode is DIP switch selectable Supports Link Fault Pass-Through (LFP) DIN-rail mountable Multimode and single-mode models with SC or ST fiber connectors are available Operating temperature range from -40 to 75 C (T models) - 2 -

Panel Layout 1. DIP switch 2. Reset button 3. Terminal block for power input and grounding 4. Power input LED 5. 100BaseFX (SC/ST connector) port 6. FX port's 100 Mbps LED 7. FX port's FDX/COL LED 8. TP port s 100 Mbps LED 9. TP port's 10 Mbps LED 10. 10/100BaseT(X) port 11. DIN-rail kit NOTE: The IMC-21A series includes the IMC-21A-M-SC, IMC-21A-M-ST, and IMC-21A-S-SC. - 3 -

Mounting Dimensions DIN-Rail Mounting The aluminum DIN-rail attachment plate should be fixed to the back panel of the IMC-21A when you take it out of the box. If you need to reattach the DIN-rail attachment plate to the IMC-21A, make sure the stiff metal spring is situated towards the top. Wiring Requirements ATTENTION Safety First! Be sure to disconnect the power cord before installing and/or wiring your Moxa IMC. Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowed for each wire size. If the current goes above the allowed maximum, the wiring could overheat, causing serious damage to your equipment. - 4 -

Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point. Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately. You can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together. Keep input wiring and output wiring separated. We strongly advise that you label wiring to all devices in the system. Grounding the Moxa IMC Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the rightmost connector of the 3-contact terminal block to the grounding surface before connecting the devices. ATTENTION This product is intended to be mounted to a well-grounded mounting surface such as a metal panel. Wiring the Power Inputs The two leftmost contacts of the 3-contact terminal block connector on the IMC s top panel are used for the IMC s DC inputs. Take the following steps to wire the IMC s DC power inputs: STEP 1: Insert the negative/positive DC wires into the V-/V+ terminals. STEP 2: To keep the DC wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connector. STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor, which is located on IMC s top panel. - 5 -

Communication Connections RJ45 Ethernet Port Connection The IMC-21A has one 10/100BaseT(X) Ethernet port located on the front panel for connecting to Ethernet-enabled devices. Pinouts and cable wiring diagrams for both MDI (NIC-type) and MDI-X (HUB/switch-type) ports for both straight-through and crossover Ethernet cables are shown below: MDI Port Pinouts MDI-X Port Pinouts 8-pin RJ45 Pin Signal Pin Signal 1 Tx+ 1 Rx+ 2 Tx- 2 Rx- 3 Rx+ 3 Tx+ 6 Rx- 6 Tx- Straight-Through Cable Wiring CrossOver Cable Wiring - 6 -

Fiber Optic Port Connection The concept behind the SC/ST port and cable is quite straightforward. Suppose you are connecting devices I and II. Contrary to electrical signals, optical signals do not require a circuit in order to transmit data. Consequently, one of the optical lines is used to transmit data from device I to device II, and the other optical line is used transmit data from device II to device I, for full-duplex transmission. All you need to remember is to connect the Tx (transmit) port of device I to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit) port of device II. If you make your own cables, we suggest labeling the two sides of the same line with the same letter (A-to-A and B-to-B, as shown below, or A1-to-A2 and B1-to-B2). SC-Port Pinouts SC-Port to SC-Port Cable Wiring ST-Port Pinouts ST-Port to ST-Port Cable Wiring ATTENTION This is a Class 1 Laser/LED product. To avoid causing serious damage to your eyes, do not stare directly into the laser beam. - 7 -

DIP Switch Settings DIP No. Function ON OFF (Default setting) Force Fiber Port Duplex Half-duplex Full-duplex 1 OFF : Forces Full-duplex on Fiber port. ON : Forces Half-duplex on Fiber port. Link Fault Pass Through Disable Enable OFF : Enables Link Fault Pass Through, the link status on 2 the TX port will inform the FX port of the same device and vice versa. ON : Disables Link Fault Pass Through, the link status on the TX port will not inform the FX port. Force TP Duplex Half-duplex Full-duplex 3 (Only when Auto Negotiation (DIP 5) is disabled) OFF : Forces Full-duplex on Ethernet port. ON : Forces Half-duplex on Ethernet port. Force TP Speed 10Mbps 100Mbps 4 (Only when Auto Negotiation (DIP 5) is disabled) OFF : Forces 100Mbps on Ethernet port. ON : Forces 10Mbps on Ethernet port. Auto Negotiation Disable Enable OFF : Enables Auto Negotiation function; the speed and duplex states for each port link segment are automatically 5 configured using the highest performance interoperation mode. ON : Disables Auto Negotiation function; the speed and duplex states depend on the DIP 3 & 4 configuration. After changing the DIP switch setting, you will need to power off and then power on the IMC-21A, or use a pointed object to hold the reset button down for five seconds to activate the new setting. - 8 -

LED Indicators The front panel of the Moxa IMC contains several LED indicators. The function of each LED is described in the table below. LED Color State Description Power is being supplied to the power On input. PWR AMBER Power is not being supplied to the power Off input. On FX port s 100 Mbps link is active. 100M GREEN Blinking Data is being transmitted at 100 Mbps. (FX) Off FX Port s 100 Mbps link is inactive. FDX/COL (FX) 100M (TP) 10M (TP) GREEN GREEN GREEN LFP: DIP switch is set to LFP mode On 100BaseFX port is transmitting in full-duplex mode. Blinking A data collision has occurred. Off 100BaseFX port is transmitting in half-duplex mode. On TP port s 100 Mbps link is active. Blinking Data is being transmitted at 100 Mbps. Off TP port s 100 Mbps link is inactive. On TP port s 10 Mbps link is active. Blinking Data is being transmitted at 10 Mbps. Off TP port s 10 Mbps link is inactive. DUTA DUTB F1 F2 Device1 TP1 TP2 Device2 Device 1 TP LED DUTA TP LNK LED DUTA FO LED DUTB FO LED DUTB TP LNK LED Device 2 TP LED TP1 Faulted OFF OFF OFF OFF OFF OFF F1 Faulted OFF OFF OFF OFF OFF OFF F2 Faulted OFF OFF OFF OFF OFF OFF TP2 Faulted OFF OFF OFF OFF OFF OFF - 9 -

LFP: DIP switch is set to DIS mode DUTA DUTB F1 F2 Device1 TP1 TP2 Device2 Device 1 TP LED DUTA TP LNK LED DUTA FO LED DUTB FO LED DUTB TP LNK LED Device 2 TP LED TP1 Faulted OFF OFF ON ON ON ON F1 Faulted ON ON OFF OFF ON ON F2 Faulted ON ON OFF OFF ON ON TP2 Faulted ON ON ON ON OFF OFF Auto MDI/MDI-X Connection The Auto MDI/MDI-X function allows users to connect the Moxa IMC s 10/100BaseT(X) ports to any kind of Ethernet device, regardless of the type of Ethernet cable used for the connection. This means that you can use either a straight-through cable or crossover cable to connect the IMC to Ethernet devices. Dual Speed Functionality and Switching The Moxa IMC s 10/100 Mbps switched RJ45 port auto negotiates with the connected device for the fastest data transmission rate supported by both devices. All models of Moxa IMC are plug-and-play devices, so that software configuration is not required during installation or maintenance. The half-/full-duplex mode for the switched RJ45 ports is user dependent and changes (by auto-negotiation) to full- or half-duplex, depending on which transmission speed is supported by the attached device. Autonegotiation and Speed Sensing The IMC-21A series RJ45 Ethernet port supports autonegotiation in 10BaseT and 100BaseT(X) modes, with operation governed by the IEEE 802.3u standard. This means that some nodes could be operating at 10 Mbps, while at the same time, other nodes are operating at 100 Mbps. Autonegotiation takes place when an RJ45 cable connection is made; each time a LINK is enabled. The Moxa IMC advertises its capability for using either 10 Mbps or 100 Mbps transmission speeds, with the device at the other end of the cable expected to advertise similarly. Depending on which type of device is connected, the devices will agree to operate at either 10 Mbps or 100 Mbps. If a Moxa IMC s RJ45 Ethernet port is connected to a non-negotiating device, it will default to 10 Mbps speed and half-duplex mode, as required by the IEEE 802.3u standard. - 10 -

Specifications Technology Standards IEEE802.3, 802.3u, 802.3x Interface RJ45 Port 10/100BaseT(X) Fiber Port 100BaseFX (SC, ST connectors available) LED Indicators Power, 10/100M (TP port), 100M (Fiber port), FDX/COL (Fiber port) DIP Switch The following are DIP switch selectable: TP port s connection speed, Half-/Full-duplex mode, and Force/Auto mode Fiber connection s Half-/Full-duplex mode Link Fault Pass-Through (LFP) Fiber Optics Multimode (100BaseFX) Single-mode (100BaseFX) Distance, km 5 40 Wavelength, nm 1300 1310 Min. Tx Output, dbm -20-5 Max. Tx Output, dbm -14 0 Sensitivity, dbm -34 to -30-36 to -32 Power Requirements Input Voltage 12 to 48 VDC Power Consumption M-SC: 245 ma @ 12 V 130 ma @ 24 V 70 ma @ 48 V M-ST: 265 ma @ 12 V 135 ma @ 24 V 75 ma @ 48 V Connection Removable 3-contact terminal block Overload Current 1.1 A Protection Reverse Polarity Present Protection Physical Characteristics Casing IP30 protected, metal case Dimensions 30 115 70 mm (1.19 x 4.53 x 2.76 in) Weight 170 g Installation DIN-rail mounting Environmental Limits Operating Temperature Storage Temperature Ambient Relative Humidity S-SC: 255 ma @ 12 V 130 ma @ 24 V 70 ma @ 48 V Standard models: -10 to 60 C (14 to 140 F) Wide temp. models: -40 to 75 C (-40 to 167 F) -40 to 75 C (-40 to 167 F) 5 to 95% (non-condensing) - 11 -

Regulatory Approvals Safety UL 60950-1 EMI FCC Part 15, CISPR 32 class A EMS EN 61000-4-2 (ESD) Level 3 EN 61000-4-3 (RS) Level 2 EN 61000-4-4 (EFT) Level 2 EN 61000-4-5 (Surge) Level 2 EN 61000-4-6 (CS) Level 2 Shock IEC 60068-2-27 Free Fall IEC 60068-2-32 Vibration IEC 60068-2-6 Warranty 5 years Federal Communications Commission Statement FCC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC WARNING This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his or her own expense. - 12 -