IMC-21GA Quick Installation Guide

Similar documents
IMC-21A Quick Installation Guide

IMC-21 Quick Installation Guide

PTC-101 Quick Installation Guide

MOXA Industrial Media Converter

PTC-101-M12 Hardware Installation Guide

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

EDS-210A Series Hardware Installation Guide

EDS-210A Quick Installation Guide

EDS-G308 Series Quick Installation Guide

EDR-G902/G903 Quick Installation Guide

EDS-G205A-4PoE Hardware Installation Guide

IMC-101 Series Quick Installation Guide

EDS-G205-1GTXSFP Quick Installation Guide

EDS-P206A-4PoE Series Hardware Installation Guide

TN-5308 Quick Installation Guide

Moxa Industrial Media Converter

INJ-24A Series Quick Installation Guide

MOXA EtherDevice Switch EDS-205 Hardware Installation Guide

EDS-G205A-4PoE Quick Installation Guide

EDS-P206A-4PoE Series Quick Installation Guide

IMC-101G Series Quick Installation Guide

EDR-810 Series Quick Installation Guide

Moxa Industrial Media Converter

EDS-308/309 Hardware Installation Guide

Hardened 4-Port 10/100/1000M DIN-Rail Mount Switch GATB. User's Manual (V1.0 Version)

PT-7728/7828 Quick Installation Guide

Moxa ToughNet Switch

EDS-505A/508A Hardware Installation Guide

MOXA EtherDevice Switch

EDS-405A/408A Series Quick Installation Guide

EDS-405A-PTP Series Hardware Installation Guide

EDS-P510 Series Quick Installation Guide

MOXA EtherDevice Switch & PoE Splitter

IES308-2F. Introduction: Packing List: Features: 8-port Unmanaged Industrial Ethernet Switch Hardware Installation Guide

EDS-205A/208A Series Quick Installation Guide

Moxa EtherDevice Switch

EDS-510E Series Hardware Installation Guide

PT-G503-PHR-PTP Series Quick Installation Guide

EDS-308/309 Series Quick Installation Guide

MOXA EtherDevice Switch

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

EDS-G500E Series Hardware Installation Guide

ICF-1150 Series Quick Installation Guide

Features and Benefits. Certifications

CSM-200 Series. Hardware Installation Guide. First Edition, November 2009

Moxa EtherDevice Switch

IES608-2F. Introduction. ntroduction: Packing List. ist: Features:

Moxa EtherDevice Switch

EDS-510A Hardware Installation Guide

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

EDS-G512E-8PoE Series Hardware Installation Guide

Industrial Media Converter

ICF-1150 Series Quick Installation Guide

Ethernet PoE Switch - Premium Line IE-SW-PL06M-2TX-4PoE (Managed)

EDS-405A/408A Series Quick Installation Guide

Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and

TCF-142 Quick Installation Guide

Features and Benefits. Certifications

IMC-P111FX / IMC-P111P Series

EDS-G512E-8PoE Series Quick Installation Guide

RS-422/485 to Fiber Industrial Converter

10 Industrial Media Converters

IKS-G6524A/G6824A Series Quick Installation Guide

NPort S8000 Series Quick Installation Guide

Managed Ethernet Switches Value Line

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

EDS-528E Series Quick Installation Guide

Features and Benefits. Certifications

imc2 Features Introduction Industrial 2 Port Ethernet to Fiber Converter Tel: Fax:

Rugged Industrial Media Converter

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Features and Benefits. Certifications

TCF-142-RM Series Hardware Installation Guide

IMC-P111FX Series IMC-P111P Series

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Features and Benefits. Certifications

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Industrial Slim Type Fast Ethernet Rail Switch

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Moxa EtherDevice Switch

imc2f Features Industrial IEC Ethernet to Fiber Media Converter Tel: Fax:

UPort TM 200/400 Series Quick Installation Guide

Moxa EtherDevice Switch

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

ICS-G7526A/G7528A/ G7826A/ G7828A Series Quick Installation Guide

imc2g Features Introduction Industrial Gigabit Ethernet to Fiber Media Converter Tel: Fax:

EDS-G205-1GTXSFP/G308 Series

Industrial Unmanaged Ethernet Switch

Quick Start Guide. Physical Description. The Port Status LEDs

AWK-3191 Quick Installation Guide

Industrial 8-port unmanaged Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E., 24VDC power inputs

AWK-1131A Quick Installation Guide

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP

ADAM-6541 Series. Ethernet to FiberOptic Converters. Features. Introduction. Specifications. Ordering Information

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Industrial 8-Port 10/100/1000T + 2-Port 100/1000X SFP Ethernet Switch (-40~75 degrees C)

Transcription:

IMC-21GA Quick Installation Guide Moxa Industrial Media Converter Edition 4.0, June 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778 Moxa Europe: Tel: +49-89-3 70 03 99-0 Fax: +49-89-3 70 03 99-99 Moxa India: Tel: +91-80-4172-9088 Fax: +91-80-4132-1045 Moxa China (Shanghai office): Toll-free: 800-820-5036 Tel: +86-21-5258-9955 Fax: +86-21-5258-5505 Moxa Asia-Pacific: Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 2017 Moxa Inc. All rights reserved. P/N: 1802000210032 *1802000210032*

Overview The IMC-21GA Series includes industrial 10/100/1000BaseT(X) to 100/1000BaseFX media converters that provide a cost-effective solution, and are specially designed for a reliable and stable operation in industrial environments. Package Checklist Moxa s IMC-21GA is shipped with the following items. If any of these items are missing or damaged, please contact your customer service representative for assistance. IMC-21GA media converter Quick installation guide (printed) Warranty card Features The fiber port s connection speed is DIP-switch selectable Supports Link Fault Pass-Through (LFP) DIN-rail mountable Multi-mode (0.5 km) and single mode (10 km) models with SC fiber connectors are available Operating temperature range from -40 to 75 C (T models) 10K jumbo frame Redundant power inputs Supports Energy-Efficient Ethernet (IEEE 802.3 az) - 2 -

Panel Layout 1. Shielding ground 2. Terminal block for power input 3. Dip switch 4. Power LED 5. Gigabit copper (G1) / fiber (G2) port LED 6. SFP module slot 7. 10/100/1000BaseT(X) port 8. SX/LX fiber port, SC connector 9. DIN-rail kit - 3 -

Mounting Dimensions DIN-Rail Mounting The aluminum DIN-rail attachment plate should be fixed to the back panel of the IMC-21GA when you take it out of the box. If you need to reattach the DIN-rail attachment plate to the IMC-21GA, make sure the stiff metal spring is situated towards the top. Wiring Requirements ATTENTION Safety First! Be sure to disconnect the power cord before installing and/or wiring your IMC-21GA. Calculate the maximum possible current allowed in each power wire and common wire. Observe all electrical codes dictating the maximum current allowed for each wire size. If the current goes above the maximum rating, the wires could overheat, causing serious damage to your equipment. - 4 -

Use separate paths to route the wiring for power and devices. If the power wiring and device wiring must cross paths, make sure the wires are perpendicular at the intersection point. Do not run signal or communications wires and power wires in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately. You can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together. Keep input and output wires separate. We strongly advise that you label wiring to all devices in the system. Grounding the IMC-21GA Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface before connecting the devices. ATTENTION This product is intended to be mounted to a well-grounded mounting surface, such as a metal panel. Wiring the Power Inputs The 4-contact terminal block connector on the IMC-21GA s top panel is used for the IMC-21GA s two DC inputs. The top and front views of one of the terminal block connectors are shown here. STEP 1: Insert the negative/positive DC wires into the V-/V+ terminals. STEP 2: To keep the DC wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws at the front of the terminal block connector. STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor located on the IMC-21GA s top panel. - 5 -

Redundant Power Inputs Both power inputs can be connected simultaneously to live DC power sources. If one power source fails, the other live source acts as a backup, and automatically supplies all of the IMC-21GA s power needs. Communication Connections RJ45 Ethernet Port Connection The IMC-21GA has one 10/100/1000BaseT(X) Ethernet port located on the front panel to connect Ethernet-enabled devices. When connected to a 10/100 Mbps Ethernet port, the pinouts and cable wiring diagrams for both the MDI (NIC-type) and MDI-X (HUB/switch-type) ports for both straight-through and crossover Ethernet cables are: MDI Port Pinouts MDI-X Port Pinouts 8-pin RJ45 Pin Signal Pin Signal 1 Tx+ 1 Rx+ 2 Tx- 2 Rx- 3 Rx+ 3 Tx+ 6 Rx- 6 Tx- Straight-Through Cable Wiring Crossover Cable Wiring - 6 -

1000BaseT(X) Ethernet Port Connection 1000BaseT(X) data is transmitted on differential TRD+/- signal pairs over copper wires. When connected to a 1000 Mbps Ethernet port, the pinouts and cable wiring diagrams for both the MDI (NIC-type) and MDI-X (HUB/switch-type) ports for both straight-through and crossover Ethernet cables are: MDI/MDI-X Port Pinouts Pin Signal 1 TRD (0) + 2 TRD (0) - 3 TRD (1) + 4 TRD (2) + 5 TRD (2) - 6 TRD (1) - 7 TRD (3) + 8 TRD (3) - 1000BaseSFP Fiber Port Connection The Gigabit Ethernet ports on the IMC-21GA are 1000BaseSFP Fiber ports, which require using Gigabit mini-gbic fiber transceivers to work properly. The concept behind the LC port and cable is straightforward. Suppose you are connecting devices I and II: contrary to electrical signals, optical signals do not require a circuit in order to transmit data. Consequently, one of the optical lines is used to transmit data from device I to device II, and the other optical line is used to transmit data from device II to device I, for full-duplex transmission. Remember to connect the Tx (transmit) port of device I to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit) port of device II. If you make your own cable, we suggest that you label the two sides of the same line with the same letter (A-to-A and B-to-B, as shown below, or A1-to-A2 and B1-to-B2). LC-Port Pinouts LC-Port to LC-Port Cable Wiring - 7 -

1000BaseSX/LX Fiber Port (IMC-21GA-SX-SC, IMC-21GA-LX-SC) The concept behind the SC port and cable is straightforward. Suppose you are connecting devices I and II: contrary to electrical signals, optical signals do not require a circuit in order to transmit data. Consequently, one of the optical lines is used to transmit data from device I to device II, and the other optical line is used to transmit data from device II to device I, for full-duplex transmission. All you need to remember is to connect the Tx (transmit) port of device I to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit) port of device II. If you make your own cables, we suggest that you label the two sides of the same line with the same letter (A-to-A and B-to-B, as shown below, or A1-to-A2 and B1-to-B2). SC-Port Pinouts SC-Port to SC-Port Cable Wiring ATTENTION The IMC-21GA is only compatible with transceiver modules from Moxa's SFP-1G Series and SFP-1FE Series. If you are using the SFP-1FESLC-T, SFP-1FELLC-T, or SFP-1FEMLC-T, use version V1.3 or above to ensure that the IMC-21GA's media converter functionality works properly. ATTENTION This is a Class 1 Laser/LED product. To avoid causing serious damage to your eyes, do not stare directly into the laser beam. - 8 -

DIP Switch Settings Dip No. Function ON OFF 1 Fiber Speed 100M 1000M* ON: Forces 100 Mbps on fiber port Note: When setting the mode for the IMC-21GA, use the Moxa SFP-1FE Series SFP modules OFF: Forces 1000 Mbps on fiber port Note: When setting the mode for the IMC-21GA, use the Moxa SFP-1G Series SFP modules 2 Energy-Efficient Ethernet Enable Disable* ON: Enables Energy-Efficient Ethernet to allow for less power consumption during periods of low data activity OFF: Disables Energy-Efficient Ethernet 3 Link Fault Pass-Through Enable Disable* ON: Enables Link Fault Pass-Through; the link status on the TX port will inform the FX port of the same device and vice versa. OFF: Disables Link Fault Pass-Through; the link status on the TX port will not inform the FX port. 4 Reserved *Default setting After changing the DIP-switch setting, you will need to power off and then power on the IMC-21GA. LED Indicators The front panel of the Moxa IMC-21GA contains several LED indicators. The function of each LED is described in the table below. LED Color State Description PWR1 Amber PWR2 Amber G1 G2 Green On Off On Off Power is being supplied to the power input (V1+, V1-) Power is not being supplied to the power input (V1+, V1-) Power is being supplied to the power input (V2+, V2-) Power is not being supplied to the power input (V2+, V2-) On TP port s 1000 Mbps link is active Blinking Data is being transmitted at 1000 Mbps Off TP port s 1000 Mbps link is inactive On TP port s 10/100 Mbps link is active Amber Blinking Data is being transmitted at 10/100 Mbps Off TP port s 10/100 Mbps link is inactive Green Amber On On Fiber port s 1000 Mbps link is active Blinking Data is being transmitted at 1000 Mbps Off Fiber port s 1000 Mbps link is inactive Fiber port s 100 Mbps link is active - 9 -

LED Color State Description Blinking Data is being transmitted at 100 Mbps Off Fiber port s 100 Mbps link is inactive LFP: DIP switch is set to LFP mode Device1 TP LED DUTA TP DUTA FO DUTB FO LNK (G1) (G2) LED (G2) LED LED DUTB TP Device 2 LNK (G1) TP LED LED TP1 Faulted OFF OFF OFF OFF OFF OFF F1 Faulted OFF OFF OFF OFF OFF OFF F2 Faulted OFF OFF OFF OFF OFF OFF TP2 Faulted OFF OFF OFF OFF OFF OFF LFP: DIP switch is set to DIS mode Device1 TP LED DUTA TP DUTA FO DUTB FO LNK (G1) (G2) LED (G2) LED LED DUTB TP Device 2 LNK (G1) TP LED LED TP1 Faulted OFF OFF ON ON ON ON F1 Faulted ON ON OFF OFF ON ON F2 Faulted ON ON OFF OFF ON ON TP2 Faulted ON ON ON ON OFF OFF Auto MDI/MDI-X Connection The Auto MDI/MDI-X function allows users to connect the Moxa IMC-21GA s 10/100/1000BaseT(X) ports to any kind of Ethernet device, regardless of the type of Ethernet cable used for the connection. This means that you can use either a straight-through or crossover cable to connect the IMC to Ethernet devices. - 10 -

Auto-Negotiation and Speed Sensing All of the IMC-21GA s RJ45 Ethernet ports independently support auto-negotiation for transmission speeds of 10 Mbps, 100 Mbps, and 1000 Mbps in operations according to the IEEE 802.3u standard. This means that some nodes could be operating at 10 Mbps, while at the same time, other nodes are operating at 100 Mbps or 1000 Mbps. Auto-negotiation takes place when an RJ45 cable connection is made, and then each time a LINK is enabled. The IMC-21GA advertises its capability for using 10 Mbps, 100 Mbps, or 1000 Mbps transmission speeds, with the device at the other end of the cable expected to advertise similarly. Depending on what type of device is connected, this will result in an agreement to operate at a speed of 10 Mbps, 100 Mbps, or 1000 Mbps. If the IMC-21GA s RJ45 Ethernet port is connected to a non-negotiating device, it will default to a speed of 10 Mbps and half-duplex mode, as required by the IEEE 802.3u standard. Specifications Technology Standards Interface RJ45 Port Fiber Port LED Indicators DIP Switch Fiber Optics IEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.3az 10/100/1000BaseT(X), RJ45 connector IMC-21GA-SX/LX-SC: 100/1000Base-SX/LX, SC connector IMC-21GA: 100/1000BaseSFP slot Power (PWR1, PWR2), G1 (TP Port), G2 (Fiber Port) The following are DIP-switch selectable: Fiber port s connection speed (FX Speed), Energy-Efficient Ethernet (EEE), Link Fault Pass-Through (LFP) Multi-mode (IMC-21GA-SX-SC) Single mode (IMC-21GA-LX-SC) Distance, km 0.5 10 Wavelength, nm 850 1310 Min. Tx Output, dbm -10-9 Max. Tx Output, dbm -3-3 Sensitivity, dbm -20-21 Power Requirements Input Voltage 12 to 48 VDC (10 to 60 VDC) Input Current 285 ma @ 12 VDC; 156.0 ma @ 24 VDC Connection Removable 4-contact screw-on terminal block Overload Current 1.5 A Protection Reverse Polarity Present Protection Physical Characteristics Housing IP30 protect, metal case Dimensions 30 115 70 mm (1.19 x 4.53 x 2.76 in) Weight 170 g Installation DIN-rail mounting - 11 -

Environmental Limits Operating Temperature Standard models: -10 to 60 C (14 to 140 F) Wide temp. models: -40 to 75 C (-40 to 167 F) Storage Temperature -40 to 75 C (-40 to 167 F) Ambient Relative 5 to 95% (non-condensing) Humidity Regulatory Approvals Safety UL 60950-1 EMI FCC Part 15, CISPR (EN 55032) class A EMS EN 61000-4-2 (ESD) Level 3 EN 61000-4-3 (RS) Level 3 EN 61000-4-4 (EFT) Level 3 EN 61000-4-5 (Surge) Level 3 EN 61000-4-6 (CS) Level 3 Shock IEC 60068-2-27 Free Fall IEC 60068-2-32 Vibration IEC 60068-2-6 Warranty 5 years Federal Communications Commission Statement FCC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC WARNING This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his or her own expense. - 12 -