Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Similar documents
Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Solid-state Timer H3YN

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Ex. H3Y-2-C 110 VAC 30 s Rated time Supply voltage 2. Sockets and Hold-down Clips are not included with the H3Y. They must be ordered separately.

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

Switching Power Supply

Safety Relay Unit (I/O Unit Type)

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Inductive Proximity Sensor

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Voltage Current Front-mounting bracket

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Inductive Proximity Sensor

Model Number Structure

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Model Number Structure

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Cylindrical Proximity Sensor

Mini Photoelectric Sensor

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

DIN Track Mounted, Standard 22.5-mm Width Timer Range

Model Number Structure

Model Number Structure

Solid-state Counter. Power supply Output No voltage input (short/open circuit) Voltage input (high/low voltage) 30 cps 1 kcps 30 cps 1 kcps AC

Model Number Structure

Solid-state Timers H3DK

Switching Power Supply

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Solid-state Timers H3DK

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

SPST-NO SPDT DPST-NO DPDT

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

Model Number Structure

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

S8VE (60/90/120/180/240-W Models)

Photoelectric Sensor

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

H3CA-8H-AC/100/110/120

Thread length (overall length) material

Miniature Inductive Prox TL-W

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

Model Number Structure

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Special-purpose Basic Switch

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Model Number Structure

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

SRT2-ROC08, SRT2-ROC16

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Item E2CD-C1C3A E2CD-C1R5C3A E2CD-X2R5C3A E2CD-X5C3A 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Classification Enclosure rating Input voltage Type of

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Model Number Structure

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

Model Number Structure

Solid-state timer Compact, Multi-function Timers for G2R Relay Socket. Model Number Structure. Ordering Information. Model Number Legend

Self-Powered Counters H7EC

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Temperature Controller E5C4

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Conductive Level Controller

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Model Number Structure

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

I/O delay. (0.32 in ±0.06 in)

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Miniature Basic Switch

Switch Mode Power Supply

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

E4PA. Ultrasonic Displacement Sensor. Ordering Information

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

Photoelectric Sensor

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Three-phase Phase-sequence Phase-loss Relay

masterelectronics.com onlinecomponents.com

Standard with LED indicator

Solid State Relays with Failure Detection Function

Solid-State Counter/Timer

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Model Number Structure

D2SW-3L1HS D2SW-01L1HS

Model Number Structure

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Ordering Information. Door Interlock Switch D2D. Power Switch with Minimum Contact Gap up to 3 mm. D2D - 0. Model Number Legend

H7ER H7ER-V H7ER-V1 H7ER-V2 H7ER-V3

Transcription:

Solid-state Timer Miniature Timer Compatible with the MY Relay Large transparent time-setting knob facilitates time setting. Flat-blade and Phillips screwdrivers can also be used for time setting. Approved by UL and CSA. Pin configuration compatible with MY Power Relay. LED indication for power and output statuses. Conforms to EMC standards. High repeat accuracy. RC Ordering Information Operation/resetting Time-limit contact Time ranges Supply voltage Model system Surface /DIN-track mounting (with socket) Time-limit operation/ DPDT 0.1 s to 0 s 110 VAC -2 self-resetting 220 VAC 24 VDC 4PDT 110 VAC -4 220 VAC 24 VDC Note: 1. Specify the model number, supply voltage, and rated time when ordering. Ex. -2 110 VAC 1 s Rated time Supply voltage 2. Track mounted socket can be used as a front connecting socket. Accessories Track mounted socket Back connecting socket (see note 2) Solder terminal Wire-wrap terminal PC terminal PYF08A PY08 PY08QN(2) PY08-02 PYF14A PY14 PY14QN(2) PY14-02 Specifications Time Ranges Rated time 1 s 5 s 10 s 30 s 0 s Time setting range 0.1 to 1 s 0.2 to 5 s 0.5 to 10 s 1.0 to 30 s 2.0 to 0 s 1

Ratings Item Rated supply voltage Operating voltage range 110, 220 VAC (50/0 Hz), 24 VDC (see note) 85% to 110% of rated supply voltage -2/-4 Power consumption 100 VAC: Relay ON: 1.5 VA (1.3 W) Relay OFF: 0.8 VA (0.5 W) 200 VAC: Relay ON: 1.8 VA (1.5 W) Relay OFF: 1.2 VA (0.9 W) 24 VDC: Relay ON: 0.9 W Relay OFF: 0.07 W Control outputs -2: 5 A at 250 VAC, resistive load (cosφ = 1) -4: 3 A at 250 VAC, resistive load (cosφ = 1) Note: With DC ratings, single-phase full-wave rectified power sources may be used. Characteristics Accuracy of operating time ±2% Setting error ±10% ( time division at rated voltage and room temperature) Reset time 0.1 s Influence of voltage ±2% Influence of temperature ±5% Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/0 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying metal parts) (see note) 2,000 VAC, 50/0 Hz for 1 min (between operating power circuit and control output) (see note) 2,000 VAC, 50/0 Hz for 1 min (between different pole contacts; 2-pole model) (see note) 1,500 VAC, 50/0 Hz for 1 min (between different pole contacts; 4-pole model) 1,000 VAC, 50/0 Hz for 1 min (between non-continuous contacts) Vibration resistance Destruction: 10 to 55 Hz with 1.0-mm double amplitude Malfunction: 10 to 55 Hz with 1.0-mm double amplitude Shock resistance Destruction: 1,000 m/s 2 (approx. 100G) Malfunction: 100 m/s 2 (approx. 10G) Ambient temperature Operating: 10 C to 50 C (with no icing) Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h) Electrical: -2: 500,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h) -4: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h) EMC Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A Immunity ESD: IEC801-2: 4 kv contact discharge (level 2) 4 kv air discharge (level 2) Immunity RF-interference: ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: IEC801-4: 2 kv power-line (level 3) 2 kv I/O signal-line (level 4) Approved standards UL (File No. E41515), CSA (File No. LR22310) Conforms to EN50081-2, EN50082-2 Weight Approx. 50 g Note: Terminal screw sections are excluded. 2

Engineering Data -2-2 Switching operations (x 10 3 ) 250 VAC, cosφ = 1 24 VDC, cosφ = 1 Switching operations (x 10 3 ) 250 VAC, cosφ = 0.4 24 VDC, L/R = 7 ms Reference: A maximum current of 0. A can be switched at 125 VDC (cosφ = 1). Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 1 ma at 5 VDC (P reference value). -4 Load current (A) -4 Load current (A) Switching operations (x 10 3 ) 250 VAC, cosφ = 1 24 VDC, cosφ = 1 Switching operations (x 10 3 ) 250 VAC, cosφ = 0.4 24 VDC, L/R = 7 ms Reference: A maximum current of 0.5 A can be switched at 125 VDC (cosφ = 1). Maximum current of 0.2 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 1 ma at 1 VDC (P reference value). Load current (A) Load current (A) Operation Timing Chart -2-4 Time limit contact NC (9-1, 12-4) Time limit contact NC (9-1, 10-2, 11-3, 12-4) 3

Dimensions Note: All units are in millimeters unless otherwise indicated. Timers -2-4 28 28.3.3 (3.0).4 21.5 (3.0).4 21.5 Accessories (Order Separately) Use the PYF A, PY, PY -02, or PY QN(2) to mount the. When ordering any one of these sockets, replace with 08 or 14. Track Mounting/Front Connecting Sockets PYF08A Two, 4.2 5 mounting holes Eight, M3 8 sems 3.4 (Top View) Mounting Holes Two, 4.5 dia. M4 or M3 72 35.4 59±0.3 Series 90.5 8. 23 1.5 4 15±0.2 PYF A PYF14A 30 Two, 4.2 5 mounting holes Fourteen, M3 8 sems 3.4 (Top View) Mounting Holes Two, 4.5 dia. M4 or M3 72 35.4 59±0.3 4 29.5 1.5 22±0.2 30 4

PYF08A-N 22 4 1 42 12 8 5 42 12 4 1 44 14 8 5 Mounting Holes (for Surface Mounting) 44 14.5 19.8 3.2 dia. 3. dia. PYF-08A-N 41 11 12 9 A2 A2 A1 14 14 13 12 9 41 11 14 14 13 A2 A2 A1 30 PYF14A-N 4 3 42 32 8 7 44 34 2 22 24 1 12 5 14 42 32 22 12 4 3 2 1 44 34 24 14 8 7 5 Mounting Holes (for Surface Mounting) Two, 3.5 dia..5 PYF-14A-N 41 31 21 11 12 A2 14 11 10 9 A2 A1 14 13 29.5 30 12 11 10 9 41 31 21 11 14 14 13 A2 A2 A1 20.8 Back Connecting Sockets PY08, PY14 Eight, 3 1.2 dia. holes only for PY08 (Fourteen, 3 1.2 dia. holes) 24 (Bottom View) Panel Cutout 21.4 +0.2 0 0.3 25.5 29.5 25.8 +0.2 0 59.3 Series 2.7 7.7 20 PY08QN, PY14QN PY08QN(2), PY14QN(2) 2.7 25 * (See note) 2. 24 22 PY08 PY14 (Bottom View) PY, PY -02, PY QN(2) 29.5 41.5 ** (see note) Note: 1 x 1 With PY QN(2), dimension * should read 20 and dimension ** 3.5 PY08QN PY08QN(2) PY14QN PY14QN(2) PY08-02, PY14-02 22 (Bottom View) 0.3 25.5 29.5 2.7 4.3 2 1.5 PY08-02 PY14-02 5

Socket Mounting Plates (t = 1.) Applicable socket For mounting 1 socket For mounting 18 sockets PY08, PY14, PY08QN(2), PY14QN(2) PYP-1 PYP-18 Note: PYP-18 may be cut to any desired length. PYP-1 Two, 3.4-dia. holes PYP-18 Relay Hold-down Clips Y92H-3 for PYF A Socket Y92H-4 for PY Socket Mounting Track PFP-100N/PFP-50N (see note 1) End Plate PFP-M 1000 (500) (See note 2) Note: 1. Meets DIN EN50022 2. This dimension applies to PFP-50N. Spacer PFP-S

Installation Connection -2-4 Connect the DC power supply to terminals 13 and 14 according to the polarity marks. Connect the DC power supply to terminals 13 and 14 according to the polarity marks. Precautions When selecting a control output, use the -2 for switching ON and OFF the power and the -4 for switching ON and OFF the minute load. The operating voltage will increase when using the in any place where the ambient temperature is more than 50 C. Supply 90% to 110% of the rated voltages (at 12 VDC: 95% to 110%) when operating at 50 C or higher. Do not leave the in time-up condition for a long period of time (for example, more than one month in any place where the ambient temperature is high), otherwise the internal parts (aluminum electrolytic capacitor) may become damaged. Therefore, the use of the with a relay as shown in the following circuit diagram is recommended to extend the service life of the. MY Relay Do not connect the as shown in the following circuit diagram on the right hand side, otherwise the s internal contacts different from each other in polarity may become short-circuited. Use the following safety circuit when building a self-holding or selfresetting circuit with the and an auxiliary relay, such as an MY Relay, in combination. : Auxiliary relay: MY Relay Do not use the in places where there is excessive dust, corrosive gas, or direct sunlight. Do not mount more than one closely together, otherwise the internal parts may become damaged. Make sure that there is a space of 5 mm or more between any Models next to each other to allow heat radiation. The internal parts may become damaged if a supply voltage other than the rated ones is imposed on the. When more than 100 V is applied to 12 or 24 VDC, the internal element (varistor) may break. Correct Incorrect 7

Limited issue for Southeast Asian countries ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. L91-E1-1 OMRON Corporation Systems Components Division H.Q. 28th Fl., Crystal Tower Bldg. 1-2-27, Shiromi, Chuo-ku, Osaka 540 Japan Phone: 0-949-012 Fax: 0-949-021 In the interest of product improvement, specifications are subject to change without notice. Printed in Japan 0197-1M (0197) a 8