Mounting holes. Transmitter optics. 8-pol. fem. conn. Binder Series 712 (connection to PLC) Connecting cable: cab-las4/pc or cab-4/usb or cab-4/eth

Similar documents
L-LAS Series. L-LAS-TB-F-6x1-40/40-CL L-LAS-TB-F-1x6-40/40-CL. Design. L-LAS Series Laser Line Sensors. Product name:

(threaded M5) 7-pole fem. connector Binder Series 712 (connection Master/Slave) Connecting cable: cab-las7-male not necessary for single system!

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold

Mounting possibilities (threaded M5)

Mounting. possibilities. Transmitter optics. 8-pole fem. connector Binder Series 712 (PLC) Connecting cable: cab-las8/sps or cab-las8/sps-w

L-LAS Series L-LAS-LT-55. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-55 (incl. Windows - software L-LAS-LT-Scope)

L-LAS Series. L-LAS-TB-F-8x1-30/40 L-LAS-TB-F-1x8-30/40. Design. L-LAS Series Laser Line Sensors. Product name:

L-LAS Series L-LAS-CAM-256 L-LAS-CAM-256-SL L-LAS-CAM-512 L-LAS-CAM-512-SL L-LAS-CAM-1024 L-LAS-CAM-1024-SL. Design. L-LAS-CAM Series Line Cameras

4/20: Analog output mA (instead of V) Sturdy aluminium housing, anodized in blue. 7-pole fem. connector.

A-LAS Series A-LAS-CON1-FIO A-LAS-CON1-FIO-4/20. Design. A-LAS Series Analog Laser Light Barriers. Accessories: (p. 9-14) Product name:

SPECTRO Series SPECTRO-2-FIO-(IR2/IR)/(IR3/IR) Design. SPECTRO-2 Series 2-Channel Sensor Systems. Accessories: (p. 8-11) Product name:

Data Sheet SI-JET3-CON5 + SI-JET3-FK-200/100-H. 5-pole fem. connector. Binder 712. Connecting cable:

5-pole fem. connector. Binder 712 Connecting cable: cab-las5/pc or cab-las5/usb or SI-RS232/Ethernet-5. 3x potentiometer for

Accessories. cab-5/eth-500. Design. Accessories RS232/Ethernet Adapter. Product name: cab-5/eth-500 incl. software SensorFinder

SPECTRO Series SPECTRO-3-FIO-JR. Design. SPECTRO-3 Series True Color Sensors. Accessories: (cf. p ) Product name:

LCC Series LCC-130-MA. Design. LCC Series Laser Copy Counters. Product name: Accessories: LCC-130-MA (incl. Windows PC Software SI-LCC-MA-Scope)

SPECTRO Series SPECTRO-3-FIO-SLE. Design. SPECTRO-3 Series True Color Sensors. Accessories: (p ) Product name:

We Bring Light into the Dark. Reliable Differentiation also of Dark Colors.

SPECTRO Series SPECTRO-3-FIO-SLE. Design. SPECTRO-3 Series True Color Sensors. Accessories: (p ) Product name:

More Precision. optocontrol // Optical precision micrometers

Instruction Manual. optocontrol

More Precision. colorsensor // Colour Sensors, LED Analyzers

MMS/MFS Series. Laser Line Sensors. Characteristics. MMS/MFS Series Laser Line Sensors. Functional principle of the sensor

More Precision. colorsensor // Color sensors, LED Analyzers

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

Incremental encoders Solid shaft with EURO flange B pulses per revolution

YM24PAH2ABF. Contrast Sensor. LASER Technical Data. Photoelectronic Sensors. Part Number

More Precision. colorsensor // Color Sensors, LED Analyzers

Absolute encoders - SSI

Inclination sensors 2-dimensional, measuring range up to ±90

More Precision. colorsensor // Colour Sensors, LED Analyzers

Inclinometer. 4-20mA and RS232

F3EM Measuring lightcurtain in robust aluminium housing

Linear Position Transducer HLT 1000-R2

More Precision. optocontrol // Optical precision micrometers

Distance and Position Sensors

RS485 (S85- -Y13) Display (S85- -Y13) Setting push-buttons (S85- -Y03) Power supply Vdc 24 V +/- 20% PNP NPN Output Push pull

LVX Control Unit. Features:

Energetic diffuse reflection light scanner. Dimensioned drawing

More Precision. optocontrol // Optical precision micrometers

SR4000 Data Sheet.

DFP Series Fiber Photoelectric Amplifiers

Dimensions. Electrical connection

Manual Software R-LAS-LT-Scope (LT-Scope) V1.1

camera sensor ipf opti-check 1070 fully integrated camera system contour-based recognition

Trigger high-speed, retro-reflective sensors for bottles. Dimensioned drawing

optical sensors through-beam, retro-reflective, dif. reflection sensors 3000 transmitter with test input robust metal housing

Optical distance sensors. Dimensioned drawing

Inclination sensors 1-dimensional, measuring range

Optical distance sensors. Dimensioned drawing

PRODUCT INFORMATION. G6 Global Sensor. Beyond the standard Global sensor the economic way to business class

IB080QM65VA3 Part Number

C5 Series Stainless Steel Photoelectric

Sensors. Compact: S60 Series. Compact: S60 Series. Multifunction Optoelectronic Sensors

BVS UR E Ordering code: BVS001H

VISION SENSORS VISION SENSORS. Fully embedded vision sensor 3.5 VSC configurator 7 different controls Memorisation of 8 inspections

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

MLV41 Series Miniature Sensors

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

OPT2011. High-performance distance sensor. Operating Instructions

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Condition Monitoring Unit CMU 1000

F3ET Lightcurtain in robust aluminium housing

Technical data. General specifications. Indicators/operating means

Strain Gage Measuring Amplifier GSV-3

Manual / Start-Up Guide Spray Control System. L-LAS-Spray-Control Scope V1.0

SENSORS SR23. Fork Sensors - SR23. High efficiency fork sensor for booklet and multilayer labels detection APPLICATIONS

3RG7 Opto-BERO Photoelectric Proximity Switches

GSV-1A4 M12/2 M12/2. Highlights

Absolute encoders - bus interfaces Solid shaft with clamping or synchro flange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

nano ultrasonic sensors Extract from our online catalogue: Current to:

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

Basic Series 18 mm Diameter Cylindrical Sensors

Dimensions. Electrical connection

Assembly Instructions scancontrol 2700/2750 (500)

APS4 Inductive Proximity Sensors

Online data sheet VTE18-4P4240 V18 CYLINDRICAL PHOTOELECTRIC SENSORS

Electrical connection

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

Linear Position Transducer HLT 1000-R2

12 m 8 m 6 m 3 m 300 mm 500 mm 70 mm mm Power supply Vdc Vdc

(see also technical drawings) Width with inlay

More Precision. optoncdt // Laser displacement sensors (triangulation)

Encoders Absolute Singleturn Encoder Types A58CS8

Absolute encoders - bus interfaces

M2-iLAN-2 Laser Scanner

LASER SENSOR. Series LAS-T5 and LAS-T. Key-Features:

High Performance Distance Sensors

More Precision. optoncdt // Laser displacement sensors (triangulation)

POSIROT. PRAS26 Magnetic Angle Sensor. Magnetic Angle Sensors. Datasheet

scs1 highlights Phone: Fax: Web:

EAM 58 B / C - 63 A / D / E BIT PARALLEL - SSI

More Precision. optoncdt // Laser displacement sensors (triangulation)

Product description. The ability to teach up to four colors can lead to faster changeovers and shorter downtime. The CS8 series offers high

FE Series Photoelectric Sensors

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

Technical Data Photoelectric Sensors

2 m cable, 4 wires Connection connector. M8 conn., 4-pole Approximate dimensions (mm)

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

Transcription:

L-LAS Series L-LAS-TB-50-CL - Line laser <0.4 mw, wave length 670 nm, laser class 1 - Visible laser line, light curtain 50 mm - Measuring range typ. 48 mm - Resolution typ. 8 μm - Working distance up to 2000 mm - Integrated interference filter - CCD line detector with 768 pixel, 6144 subpixel (8-fold) - RS232 and Windows user interface - 2 digital inputs, 2 digital outputs - Analog output 0...+10V, in case of -4/20 additionally 4... 20mA - Switching state indication via 4 LEDs (2x red/grn, 2x yel/grn) - Sturdy aluminum housing, for use in industry - Scratch-resistant optics cover made of glass Design Product name: (Transmitter) L-LAS-TB-50-R-CL (Receiver) L-LAS-TB-50-R-4/20-CL (Receiver 4...20mA ) (incl. Windows PC software L-LAS-TB-Scope) 4/20 = Analog output 4... 20mA Mounting holes Accessories: (cf. pages 8/9) TRA-L-LAS-TB-CL-... (mounting plate) ABL-TB-50-CL (blast air top-part) Mounting hole L-LAS-TB-50-R-CL Transmitter optics Mounting holes (partly threaded M5, for mounting plate TRA-...) Sturdy aluminum housing, anodized in black LED green (ok): Meas. value within tolerance window Mounting holes (partly threaded M5, for mounting plate TRA-...) LED yellow: Power LED (multifunctional) LED red (-): Meas. value < lower tolerance threshold LED red (+): Meas. value > upper tolerance threshold 4-pol. M5 fem. conn. Binder Series 707 (RS232) cab-las4/pc or cab-4/usb or cab-4/eth 8-pol. fem. conn. Binder Series 712 (connection to PLC) cab-las8/sps 4-pol. fem. conn. Binder Series 712 (connection of transmitter) cab-las4-male (2015-10-13) L-LAS-TB-50-CL / Page 1 of 9

Technical Data Model L-LAS-TB-50-R-CL L-LAS-TB-50-R-4/20-CL Laser Working Measuring Resolution distance range Reproducibility Semiconductor laser, 670 nm, DC operation, < 0.4 mw max. opt. power, laser class 1 acc. to DIN EN 60825-1. The use of these laser sensors therefore requires no additional protective measures. distance transmitter/receiver: up to 2000 mm typ. 48 mm typ. 8 μm typ. ± 8 μm L inearity typ. 0,15% FSR (full scale range) Optical filter Interference filter A nalog output (1x or 2x) 1x voltage output (0... +10V) 1x current output (4... 20mA) 1x voltage output (0... +10V) Digital outputs (2x) (OUT0, OUT1) Digital inputs (2x) (IN0, IN1) OUT0: (-) Measuring value < lower tolerance threshold OUT1: (+) Measuring value > upper tolerance threshold pnp bright-switching/npn dark-switching or pnp dark-switching/npn bright-switching, adjustable under Windows, 100 ma, short-circuit proof IN0: Extern trigger, IN1: Teach/Reset (double function) input voltage +Ub/0V, with protective circuit V oltage supply +24VDC (± 10% ) Sensitivity setting Laser Current power correction consumption under Windows via PC adjustable under Windows via PC typ. 200 ma Enclosure rating electronics: IP54, optics: IP67 Operating Storage Housing temperature range temperature range material Housing dimensions Connectors receiver -10 C... +50 C -20 C... +85 C aluminum, anodized in black transmitter: LxWxH approx. 125 mm x 98 mm x 20 mm (without flange connectors) receiver: LxWxH approx. 70 mm x 98 mm x 20 mm (without flange connectors) 8-pole circular female connector type Binder 712 (PLC/Power) 4-pole M5 circular female connector type Binder 707 (RS232/PC) 4-pole circular female connector type Binder 712 (connection to transmitter) C onnector transmitter 4-pole circular female connector type Binder 712 (connection to receiver) LED display LED red (+): measuring value > upper tolerance threshold LED green (ok): measuring value within tolerance window LED red (-): measuring value < lower tolerance threshold LED yellow: multifunctional EMC test acc. to DIN EN 60947-5-2 Scan frequency Max. switching current Normal Speed Modus (high resolution): max. 1 khz Double Speed Modus (half resolution): max. 2 khz can be switched under Windows 100 ma, short-circuit proof I nterface RS232, parameterisable under Windows Connecting cables Connection to PC: cab-las4/pc or cab-4/usb or cab-4/eth Connection to PLC: cab-las8/sps or cab-las8/sps-w Connecting cable transmitter/receiver: cab-las4-male O utput polarity bright/dark switching, can be switched under Windows (2015-10-13) L-LAS-TB-50-CL / Page 2 of 9

Dimensions (Transmitter) All dimensions in mm (2015-10-13) L-LAS-TB-50-CL / Page 3 of 9

Dimensions L-LAS-TB-50-R-CL or L-LAS-TB-50-R-4/20-CL (Receiver) All dimensions in mm (2015-10-13) L-LAS-TB-50-CL / Page 4 of 9

Connector Assignment Connection to PLC: 8-pole fem. connector Binder Series 712 Pin: Color: Assignment: 1 white GND (0V) 2 brown +24VDC (± 10%) 3 green IN0 (EXT TRIGGER) 4 yellow IN1 (TEACH / RESET) 5 grey OUT0 (-) 6 pink OUT1 (+) 7 blue GND (0V) or with type -4/20: ANA (current 4... 20mA) 8 red ANA (voltage 0... +10V) cab-las8/sps-(length) or cab-las8/sps-w-(length) (angle type 90 ) (standard length 2m) Connection to PC: 4-pole fem. connector Binder Series 707 Pin: Assignment: 1 +24VDC (+Ub, OUT) 2 GND (0V) 3 RxD 4 TxD Connection via RS232 interface at the PC: cab-las4/pc-(length) cab-las4/pc-w-(length) (angle type 90 ) (standard length 2m) cab-las8/sps-... (max. length 25m, outer jacket: PUR) cab-las8/sps-w-... (max. length 25m, outer jacket: PUR) alternative: Connection via USB interface at the PC: Connecting cable (incl. driver software): cab-4/usb-(length) cab-4/usb-w-(length) (angle type 90 ) (standard length 2m) alternative: Connection to local network via Ethernet bus: Adapter (incl. software SensorFinder ): cab-4/eth-500 (standard length 0.5m) cab-las4/pc-... (max. length 10m, outer jacket: PUR) or cab-las4/pc-w-... (no picture) (max. length 5m, outer jacket: PUR) Optional: External CAT5 cable, e.g. cab-eth/m12d-rj45-flx-(length) cab-4/eth-500 (length 0.5m, outer jacket: PUR) 4-pole M12 fem. conn. (D-coded) for connection of an external CAT5 cable, e.g. cab-eth/m12d-rj45-flx-(length) cab-4/usb-... or cab-4/usb-w-... (no picture) (each max. length 5m, outer jacket: PUR) (2015-10-13) L-LAS-TB-50-CL / Page 5 of 9

Connector Assignment Connection L-LAS-TB-...-T-CL with L-LAS-TB-...-R-CL (or L-LAS-TB-...-R-4/20-CL) : 4-pole female connector Binder Series 712 Pin: Assignment: 1 +5VDC 2 0V (GND) 3 I-CONTROL (0V... +5V) 4 not connected cab-las4-male-(length) cab-las4-male-w-(length) (angle type 90 ) (standard length 2m) cab-las4-male-w (angle type 90 ) (picture above) or cab-las4-male (picture below) (length each max. 5m, outer jacket: PUR) LED Display L-LAS-TB-50-R-CL: (Receiver) LED display: (+) (-) Power (ok) LED red (+): Measuring value > upper tolerance threshold (OUT1) LED yellow: Power LED (multifunctional) LED red (-): Measuring value < lower tolerance threshold (OUT0) LED green (ok): Measuring value within tolerance window Laser Warning The laser transmitter of L-LAS-TB Series comply with laser class 1 according to EN 60825-1. The accessible laser radiation is harmless under reasonably foreseeable conditions. The reasonably foreseeable conditions are kept during correct operation. The use of these laser transmitters therefore requires no additional protective measures. The laser line sensors of L-LAS-TB Series are supplied with a laser warning label type CLASS 1 LASER PRODUCT. CLASS 1 Laser Product DIN EN 60825-1: 2008-05 (2015-10-13) L-LAS-TB-50-CL / Page 6 of 9

Parameterization Windows software L-LAS-TB-Scope: The L-LAS-TB sensor can be easily parameterised with the Windows user interface. For this purpose the sensor is connected to the PC with the serial interface cable cab-las4/pc. When parameterisation is finished, the PC can be disconnected again. Windows user interface: With the help of the L-LAS-TB-Scope software the following settings can be made at the sensor: - Setting of laser power and type of automatic power correction - Polarity of digital outputs - Different evaluation modes - Start of the teach process by software button - Setting of tolerance ranges for monitoring the measured value Furthermore, various numerical and graphical measured quantities can be visualized with the L-LAS-TB-Scope software. For example, the raw data of the CCD line sensor can be displayed graphically and numerically. (2015-10-13) L-LAS-TB-50-CL / Page 7 of 9

Accessories Mounting plate for and L-LAS-TB-50-R-CL (respectively L-LAS-TB-50-R-4/20-CL): (please order separately) TRA-L-LAS-TB-CL-400 (total length 400 mm, max. transmitter/receiver distance cf. chart below) TRA-L-LAS-TB-CL-600 (total length 600 mm, max. transmitter/receiver distance cf. chart below) TRA-L-LAS-TB-CL-800 (total length 800 mm, max. transmitter/receiver distance cf. chart below) (Aluminium housing, anodized in black) Distance transmitter/receiver TRA-L-LAS-TB-CL-... (mounting plate) Max. distance T/R in case of use of mounting plate: TRA-L-LAS-TB-CL-400 TRA-L-LAS-TB-CL-60 0 TRA-L-LAS-TB-CL-80 0 L-LAS-TB-28-T-CL L-LAS-TB-28-R-CL 222 mm 422 mm 622 mm L-LAS-TB-50-R-CL 205 mm 405 mm 605 mm L-LAS-TB-75-T-CL L-LAS-TB-75-R-CL 200 mm 400 mm 600 mm L-LAS-TB-100-T-CL L-LAS-TB-100-R-CL 160 mm 360 mm 560 mm (2015-10-13) L-LAS-TB-50-CL / Page 8 of 9

Accessories Blast air top part: ABL-TB-50-CL (Plastic housing, black, please order separately for each transmitter and receiver) suitable for: and L-LAS-TB-50-R-CL (or L-LAS-TB-50-R-4/20-CL) All dimensions in mm (2015-10-13) L-LAS-TB-50-CL / Page 9 of 9