UPGRADE INSTRUCTIONS

Similar documents
1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically.

Quick Installation Guide TU-S9

V-Sperm Features and Benefits

MYOB ODBC Direct. Installation Guide

See Clean. Installation and Set Up Guide V with Confidence. 3M Clean-Trace Data Trending Software. 3M Food Safety

GP-N100 Utility Software Manual

U3 Encryption Utility User Guide

Batch Eligibility Long Term Care claims

Installing ProjectSpec from the ProjectMatrix DVD

Data Manager Installation and Update Instructions

LOREX CLIENT 3.0 SOFTWARE MANUAL IRMS Integrated Remote Management Software

3. IMPORTANT: When prompted, accept the default Installation directory.

Version: 01P02B. U3 Map Maker Operational Guide

Table of Contents. On-Call Advanced Diabetes Data Management Software V1.0 User s Manual

USER MANUAL for USB Data Link

JPRO Fleet Service Portal User s Guide

LiteShow WIRELESS FREEDOM FOR YOUR PROJECTOR. QUICK START GUIDE

Windows Download & Installation

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

CompuLEAD: Installing LeadLINK Plus!

Lab Determining Data Storage Capacity

STOP! Read these instructions before connecting the PR3 to your Computer

CCC ONE Total Claims Solution. New Install and Set Up Reference Guide. version and above

CCC ONE Comp-Est. Reference Guide for Upgrading to CCC ONE Comp-Est. version 4.2 and above

Grain Tracker Operators Manual

EDS Attn: EDI Unit P.O. Box 2991 Hartford, CT

SAS Installation Instructions Windows 2003, XP, 2000, NT. Workstation Installation Guidelines

User Manual. Thermo Scientific Orion

CCC ONE Comp-Est. New Install Reference Guide. version 4.5 and above

Quick Start Guide. Laplink Software, Inc. Quick Start Guide. w w w. l a p l i n k. c o m / s u p p o r t MN-LLG-EN-14 (REV. 01/08)

Lab: Advanced Installation of Windows XP. Introduction

itrax PC Replacement Quick Start Guide P/N Pre-Software Installation

MODEL.6715 DATA ACQUISITION SOFTWARE INSTRUCTION MANUAL

OptionPower 3.2. for Office 2007 STARTUP GUIDE. Interactive Audience Response Systems

VS-626M5 Parameter Upload/Download Software User s Manual (Preliminary) 5/18/99

Q-Lab Software OPERATION MANUAL

LASER Installation Guide for Standalone Install

USB driver and Software Installation. UPS Monitoring and Management Software

Centra Workbench (V3.12 onwards)

Trademark. Cadex C5100 BatteryStore User Guide

Procedures to Install Eye Com's ImageMouse and ImageMouse Plus using Windows XP platform

User Manual. Computer Program Pomiar Win. Version: 4.0.X. Manual number: ITKU A MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS

Introduction Features... Installation

Media Archive Server for Small Teams

Introduction This section describes the procedure to update an SN4500 to software version 2.05.

jraven Quick Start Guide

Dot Matrix Indicator Programming

UNGASS DATA ENTRY SOFTWARE: GLOBAL REPORTING 2008 SETUP NOTES

VAPOR PRO COMMUNICATIONS

How to upgrade the Samsung Galaxy SPICA i5700 mobile phone to Android 2.1 operating system

Robotic Arm Edge with USB PC Interface User's Manual

Instructions for MX350 Firmware Upload

Before inserting the card and drivers, you need to install DirectX 9.0c. This is available on the installation CD included with your product.

PT Data Management Software User s Guide

GL500A Application Manual

LadibugTM Visual Presenter Image Software User Manual

Firmware, Database, & PC Application Update Installation Instructions

Technical Specifications

BESTCOMSPlus Software

KYOCERA Net Viewer 5.3 User Guide

USB-MIDI Driver installation and settings...1 Windows XP users... 1

CCC ONE Appraisal Platform

Installation Guide. Data Management Multilanguage Software for the CLA-1 Luminometer Version 2.5. Doc. No Rev.

Trademark. Cadex C5100 BatteryStore v1.5 User Guide

Table of Contents. 1. Intended Use Overview Materials Required System Requirements User Mode 4

INSTALLING THE PS3 XBOX READY SOFTWARE:

PropertyBoss Upgrade

CHAPTER 1. Welcome to WalkGuard- IPCam

User s Guide. Know Your USA

queue (for V1 Driver) (for Windows XP) Visual Presenter Image Software User Manual

QUICKBOOKS PRO 2008 INSTALLING QUICKBOOKS PRO AND STUDENT DATA FILES

Instrument Software Update Instructions

Programming Manual KX-TVA50 KX-TVA200. Voice Processing System. Model

Outlook to Mac Mail. Installation Guide. Overview Migration Software System Requirements Application Loading...

Installing and Setting Up the Snap-on EPC. Rev.1.6 (12 Apr 2012) PN EN

ELECTRONICS. Printed in Korea Code No.: GH A English. 06/2001. Rev.1.0. World Wide Web

Installing AppleWorks 6 FOR WINDOWS

CellSync Manager. User Manual F8V7D006-SS F8V7D008-SS. Get online and synchronize anywhere. Web Access. Phone Book Manager

Podium Plus Data Analysis Software. User Manual. SWIS10 Version

CONTENTS. 1.0 Overview. 2.0 Outline Functionality. 3.0 Minimum system requirements. 4.0 Programme Installation. 5.0 Starting PC DVR Disk Replay Client

OS Installer. Installation Instructions

Configuring the WebDAV Folder for Adding Multiple Files to the Content Collection and Editing Them

Registering Your D1 with the System (Windows 2000)

GP2X USB Accelerometer Quick Start Guide

Symantec Backup Exec Quick Installation Guide

A Guide to Installing OLI Software

Firmware, Database, & PC Application Update Installation Instructions

KD Max V5 Upgrade & Installation Guidance For upgrade users KD Max V5 Upgrade & Installation Guidance

PhotoPDF User Guide. PhotoPDF. Photo to PDF Converter

Axxis Biometrics LLC. BioAxxis L113 Fingerprint Door Lock Programming Kit

Introduction. 1 available USB type A (downstream) port. Windows 98, Windows ME, Windows 2000, Windows XP,

Note: You must already be enrolled and issued with a Username and Password

WA1804 WebSphere Enterprise Service Bus v6.2 Administration. Classroom Setup Guide. Web Age Solutions Inc. Copyright Web Age Solutions Inc.

Installing HostExplorer 10 For the PC Author: Byron Watanabe

Customer Inquiries Sten-Tel

3M Molecular Detection System Software Upgrade/Installation Instructions

HP Travel Phone User s Guide

Kinetica 5.1 Kinetica Installation Guide

How to install the software of ZNS8022

Thermal Transient Test Installation and Operating Manual

Transcription:

Version 2.48 or 2.49 & Version 3.48 or 3.49 UPGRADE INSTRUCTIONS System Upgrade Requirements NOTE: Non I-Button: V-Sperm Gold version 3.49 must be installed with SQA-V Gold version 2.49. I-Button: V-Sperm Gold version 3.48 must be installed with SQA-V Gold version 2.48. Instructions Included. The upgrade process will not effect the tests loaded into the SQA- V. Those test that have been loaded will remain in the SQA-V. If you have an I-Button instrument, make sure you are loading I-Button software (SQA-V version 2.48 & V-Sperm version 3.48) If you have a Non I-Button instrument, make sure you are loading Non I-Button software (SQA-V version 2.49 & V-Sperm version 3.49) SQA-V Instrument: SQA-V Version 2.45 or later must be installed on the SQA-V in order to upgrade RS232 communication cable (supplied with the system) must be connected A current version of V-Sperm Gold must be installed on the PC after upgrading to SQA-V Gold version 2.48 or 2.49 (instructions included in this document) PC and related components (V-Sperm Gold interface): 1 GHz processor, Pentium 3 RAM 256 MB AGP-video display card with minimum 16 MB RAM memory Color video: Minimum 16 bit (65, 535) CD ROM drive 200 MB free hard disk space for image capturing Video resolution: Minimum 640X480 Minimum requirements (V-Sperm Gold interface): Windows 2000, XP Requires: DirectX, DivX. MS Excel/Word for exporting to file formats Free RS232 serial communications port (serial COM port) 2 USB ports Electrical surge protector Overview of the Seven Step Upgrade Process: version 2.48 or 2.49 1. TRANSFER SQA-V ARCHIVE: Transfer all records from the SQA-V to V-Sperm 2. PRINT SELF TEST DATA/DEFAULT SETTINGS: Instructions in your User Guide 3. INSTALL: SQA-V Gold Version 2.48 or 2.49 (I-Button or non I-Button depending on which system you have) 4. CLEAR MEMORY: Clean the SQA-V system memory 5. PRINT SYSTEM PARAMETERS: Print SQA-V service information after uploading new software to compare pre and post upload parameters 6. COMPARE SELF TEST and SYSTEM PARAMETERS Release date: September 17, 2010 1 MES Global www.mes-global.com

Step 1 Transfer SQA-V Archive Before beginning the upgrade process it is necessary to transfer the patient and control archive from the SQA-V to V-Sperm. To do this: 1. Turn on the SQA-V from the rear switch and the front on/off key 2. Activate the service data screen: MAIN MENU>SERVICE>SERVICE DATA 3. Open the V-Sperm program on the PC and sign-in 4. Click the Import/Export navigation button in V-Sperm. Select: Import Data 5. Select: Import Archive (Patient Data) 6. Click: CONTINUE on the V-Sperm import data screen 7. Repeat steps 5-7 to import the Control archive by selecting Import Controls on the import data screen instead of Import Archive. 8. After importing both archives (Patient Data and Controls) V-Sperm will ask Do you want to delete the SQA-V (Controls) archive? Select NO 9. Close V-Sperm but leave the PC on Step 2 Print SELF TEST DATA and DEFAULT SETTINGS Follow the instructions in your User Guide to print a copy of your Self Test Data Follow the instructions in your User Guide to print a copy of your Default Settings Keep a copy of each printout (to compare parameters and re-enter your defaults after completing the installation) Step 3 Please note: During this phase the PC and the SQA-V are hooked-up and the PC is still on from Step 1. All other programs on the PC should be closed! Install SQA-V Gold Software Version 2.48 or 2.49 Turn off the SQA-V from the rear panel Press and hold the SERVICE key of the SQA-V while turning on the SQA-V from the rear panel When the lower SQA-V screen is blank or displays garbled lines/lights release the SERVICE key Insert the CD or Flash Stick: SQA-V Gold Software Version 2.48 or 2.49 into the PC s CD-ROM Navigate to the CD Rom Drive or Flash Stick containing the software. Double click MesNewSQAVersion to begin setup A pop-up message will appear briefly. If prompted to start installation select: NEXT Release date: September 17, 2010 2 MES Global www.mes-global.com

This screen will appear. It will display the communication port that is being used for the SQA-V. In the Password box enter the password: fertility Press Start to continue WARNING: Do not touch the keyboard or mouse during the downloading process. The screen will indicate the progress of the software loading process: Estimated time remaining Percentage counter Time elapsed The next screen will indicate that the download was successful Click CLOSE to exit To complete the uploading of new software, the memory needs to be cleared Step 4 NOTE: During this phase the PC and the SQA-V are hooked-up and the PC is still on from Step 1 Clear the SQA-V Memory Turn OFF the SQA-V from the rear panel Turn ON the SQA-V from the rear panel and the front panel Wait for the Main Menu to appear (5-7 Minutes) - screen may look fragmented From the Main Menu select: SERVICE > SERVICE DATA Navigate to your CD ROM or Flash Stick (it may still be in the CD drive from Step 3) Double click SetupCleanMem to begin memory clearance Release date: September 17, 2010 3 MES Global www.mes-global.com

A pop-up message will appear WARNING: Do not touch the keyboard or mouse while the download is in process. Clear Flash Area screen will appear Press START A screen will indicate that the download has been successful IMPORTANT: Close this Clear Flash Area screen TURN OFF the SQA-V from the rear panel Step 5 WARNING: The SQA-V should have been turned off in Step 4. Do not begin Step 5 if the SQA-V has not been turned off! Print System Parameters Turn ON the SQA-V from the rear panel and from the front keypad From the MAIN MENU select: SERVICE > PRINT SQA-V DEFAULT SETTINGS Highlight: SELF TEST DATA PRESS: ENTER to print a copy of the SYSTEM PARAMETERS Compare these results with the pre-download SELF TEST DATA parameters Step 6 Compare SELF TEST and SYSTEM PARAMETERS Compare the following critical parameters (in bold) to ensure that they have not changed as a result of the installation of the version 2.49 SQA-V software: #1, 2, 3, 4 and 8, 9,10,11,13,15, 16, 17, 18 Check to see if the SQA-V Serial Number is on the post-download SQA-V printout (at the top) Call technical support if the numbers are different Troubleshooting Time out error DO NOT ACTIVATE THE SQA-V SOFTWARE Check connection between SQA-V and PC Close the "Clear Flash Area" screen Close all applications Re-run Steps 4 of the installation Call for technical support if the problem recurs Release date: September 17, 2010 4 MES Global www.mes-global.com

Upgrade System Requirements SQA-V with communication cable and power cable PC Version 3.48 or 3.49 Hardware requirements 1Ghz or higher CPU 256 megabytes RAM AGP Video Display Card with at least 16 megabytes of RAM memory CD-ROM compatible drive RS232 communications port (serial) Two available USB ports Software requirements Compatible operating systems: Windows XP Windows 2000 Microsoft Excel or Word for export feature DirectX 8.1* At least 40 Gbyte of free hard disk space (if not using a compression tool) or 400 MB if a video compression tool is used. Video resolution 640x480 Video color quality 16-bit *NOTE ON DIRECTX installation: DirectX 8.1 is pre-installed on Windows XP. To install on other operating systems follow instructions obtained through the website listed below: Windows 2000 http://download.microsoft.com/download/win2000pro/update/8.1/nt5/en-us/dx81nteng.exe Phase 1 Software Installation 1. Close any open programs before beginning the upgrade process. 2. Navigate to your CD ROM or Flash Stick and click SETUP 3. The screen will display: Initializing Wise Installation Wizard 4. Click NEXT when the Welcome screen is displayed 5. Click NEXT when the Choose Destination Location screen is displayed to accept the V-Sperm default folder or click Browse to select another folder. 6. Click NEXT when Select Program Manager Group screen is displayed to begin copying files. If a messages Digital Signature Not Found is displayed, click YES 7. Installation complete: Click OK to restart the PC and complete the software installation 8. To activate the V-Sperm Gold software, double click the icon on the PC desktop. Release date: September 17, 2010 5 MES Global www.mes-global.com

Phase 2 System Set-Up: To use the SQA-V Gold version 2.48 or 2.49 all system defaults MUST BE ENTERED. 1. The SQA-V with version 2.48 or 2.49 and the PC with V-Sperm version 3.48 or 3.49 must be connected via the RS232 cable and both turned on 2. In the SQA-V go to: MAIN MENU > SERVICE > SERVICE DATA 3. In the V-Sperm go to: SET-UP > SQA-V. Press: Continue and the following set-up screen will be displayed (NOTE: You should have a copy of your Defaults from a previous step) If CONTROL information is not available enter zeros for LOT#, Target Value, +/- Range for Automated and Manual settings for Level 1, 2 and Negative Control settings. Enter the following set-up information: Date format: DD/MM/YY (Europe) or MM/DD/YY (USA) Local date Morphology Criteria: WHO 3rd or WHO 4th Concentration/Chamber standard: 1 or 2 ( 2 recommended) Printing options (check the box to enable): Automatically print of test results Automatically print self test report on start-up Control defaults Enter all zeros if Control Material not available at this time. Click APPLY to transfer the data to the SQA-V this may take 3-5 minutes. Release date: September 17, 2010 6 MES Global www.mes-global.com