MegaRAID SAS e RAID Controller

Similar documents
MegaRAID SAS 9285CV-8e RAID Controller. Quick Installation Guide

MegaRAID CacheVault Power Module 02

Syncro CS e Controller

MegaRAID SAS i and SAS i RAID Controllers

MegaRAID CacheVault Flash Module 02

MegaRAID Remote Kit for the LSIiBBU06, LSIiBBU07, and LSIiBBU08 Intelligent Battery Backup Units. Quick Installation Guide

Intel RAID Controller RS3DC040/ RS3DC080 Quick Installation User's Guide

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapters. User Guide

Upgrading Memory in the 6580/6780 Controller CRU

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA)

LSI SAS i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

Replacing Failed Memory in the 6580/6780 Controller Module

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

Replacing a Drive in the CSM200 Drive Module

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

Replacing a Controller Battery in the ST2500 M2 Array Module

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

P RO D UC T SEL EC TOR GUID E. Storage Adapters. March 2014

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

Connecting the Arcserve UDP Appliance Expansion Shelf to the UDP Appliance Server

P RO D UC T SEL EC TOR GUID E. Storage Adapters. March 2012

Replacing an ESM/IOM CRU in the ST2501 M2 Drive Module

Upgrading or Host Interface Card in the ST2500 M2 Array Module

Replacing an ESM/IOM CRU in the CSM200 Drive Module

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide

A33606-PCI-01 SAS-2 Expander User Manual. Version: Document Number:

SAS e PCI Express to 12Gb/s SAS Host Bus Adapter

A33606-PCI Command Line Interface Version: Document Number:

IBM ATA 133 RAID Controller User's Guide

Modular RAID Controllers

96RC-SAS-8P-PE-LS3. Test Report. This report is also applied to the following drives since they are same generation with very similar specification.

LSI SAS6160 LSI SAS Switch. Configuration Guide

ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide

ServeRAID M5025 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide

RAID EzAssist Configuration Utility User Reference Guide

SAS Expander Card User s Manual CHENBRO. SAS Expander Card User s Manual. April / 01 /

LSISAS6160 SAS Switch r Firmware

Upgrading and Servicing Guide

RAID Card with HyperDuo

ServeRAID M1015 SAS/SATA Controller for System x IBM System x at-a-glance guide

Upgrading and Servicing Guide

QuickSpecs. Models. Overview

Turbo PCI Express. PCI Express adapter for desktop PC. PCIe 4 to PCIe 4 data cable, 1.5 meter. Turbo ExpressCard. ExpressCard 34 adapter for laptop

LSI Corporation

AHA PCI-to-Fast SCSI Host Adapter. Fast SCSI Connection for High-Performance SCSI Peripherals for Pentium PCs

USER S GUIDE. Integrated RAID for SAS. April Version 1.1 DB

SATA 150 PCI Card 2-Channel

CHENBRO CK port SAS Expander Card User s Manual. Version B0. September / 01 / 2009

Dual/Quad Channel 4-Port USB 3.0. PCI Express Card

TrueNAS Z SERIES NODE SATADOM REPLACEMENT KIT. August 2017 Edition

Upgrading and Servicing Guide

DP SATA 6Gb/s PCIe i/e Quick Installation Guide

QuickSpecs. Models. HP Smart Array P400i Controller. Overview

DP SATA 6Gb/s 2-Port PCIe

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

A33606-AIC-02 User's Guide

LSI and HGST accelerate database applications with Enterprise RAID and Solid State Drives

Upgrading and Servicing Guide

QuickSpecs. Models. Overview

SAS-933E The SAS-933E2/E1 Storage Backplane USER'S GUIDE

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide

Dell DL1300 Appliance Interoperability Guide

SATA 150 PCI Card 2-Channel

PCIe SATA II Channel RAID Card. User Manual

Accelerate Database Performance and Reduce Response Times in MongoDB Humongous Environments with the LSI Nytro MegaRAID Flash Accelerator Card

1U Device Expansion Unit Configuration Guide

SELECTION GUIDE. Storage Solutions. broadcom.com

ServeRAID M5120 SAS/SATA Controller Lenovo Press Product Guide

Port PCI Quick Installation Guide

Manual. esata PCI Card 1+1. english.

USER S GUIDE. PCI Express to 3.0 Gbit/s Serial Attached SCSI (SAS) Host Adapters. August 2006 Version 1.0

USB Port PCI Express Card

RocketRAID 464. User, s Manual. Revision: 1.0 Date: Jun HighPoint Technologies, Inc.

PCIe SATA 6G + PATA Card

RocketRAID 2840A. SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller. User s Guide v1.0

1. If the impaired node is part of an HA pair, disable automatic giveback from the console of the healthy node:

ServeRAID M5225-2GB External SAS/SATA Controller Product Guide

Serial ATA PCI RAID Quick Installation Guide

ServeRAID F GB and 800GB SAS/SATA Controllers for IBM System x Product Guide

RocketRAID 3622/3620. SATA 6Gb/s PCI-Express 2.0 x 8 RAID HBA

QuickSpecs. What's New. Models. Overview

LSI MegaRAID Advanced Software Evaluation Guide V3.0

System x Education. Servicing the ServeRAID M1000 and M5000 Series SAS/SATA II Controllers. October 2009 Study guide

PCIE SATA II PATA RAID CARD

GSC-PCI TO PMC ADAPTER

This diagram shows the workflow of the DIMM replacement procedure for a FAS2600 system.

High Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide

FASTTRAK TX4000 QUICK START GUIDE. Version 1.2

HP ProLiant MicroServer

ThinkCentre Hardware Installation and Replacement Guide. Machine Types 6417, 6418, 6449, 6453

Intel RaId Intel Product Quick Reference Matrix - Servers Q1,

Part Number: 92P1476. h Battery pack. h Computer

Storage Solutions. Product Guide. Spring 2011

FASTTRAK S150 TX4 QUICK START GUIDE. Version 1.2

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector

RocketRAID 3600 Series

ThinkCentre Hardware Installation and Replacement Guide. Machine Types 6062, 6065, 6071, 6076, 6089, 7103, 9011, 9014, 9071, 9089, 9162, 9182, 9303

Transcription:

MegaRAID SAS 9286-8e RAID Controller Quick Installation Guide 53823-00, Rev. A 53823-00A

Revision History Version and Date 53823-00, Rev. A, Initial release of the document. Description of Changes LSI and the LSI & Design logo are registered trademarks of or its subsidiaries. All other brand and product names may be trademarks of their respective companies. reserves the right to make changes to the product(s) or information disclosed herein at any time without notice. does not assume any responsibility or liability arising out of the application or use of any product or service described herein, except as expressly agreed to in writing by ; nor does the purchase, lease, or use of a product or service from convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of or of third parties. LSI products are not intended for use in life-support appliances, devices, or systems. Use of any LSI product in such applications without written consent of the appropriate LSI officer is prohibited. This document contains proprietary information of. The information contained herein is not to be used by or disclosed to third parties without the express written permission of. Corporate Headquarters Milpitas, CA 800-372-2447 Website www.lsi.com Document Number: 53823-00, Rev. A Copyright 2012 All Rights Reserved

Thank you for purchasing the LSI MegaRAID 6Gb/s SAS 9286-8e RAID controller. Your MegaRAID controller provides reliability, high performance, and fault-tolerant drive subsystem management. Before you install your RAID controller, please take a few minutes to read this quick installation guide. If you need more information about any topic covered in this guide, refer to the related documents on your MegaRAID Universal Software Suite CD. 1 Product Overview The MegaRAID SAS 9286-8e RAID controller is a low-profile PCI-Express 3.0 RAID controller that offers a 6-Gb/s transfer rate. It controls eight external SAS/SATA ports through two SFF-8088 x4 external mini SAS connectors. The MegaRAID SAS 9286-8e RAID controller has a 1GB non-volatile DDR3 1333MT/s memory module The memory module connects to a remote LSI intelligent Battery Backup Unit 09 (LSIiBBU09). For more information about the LSIiBBU09 unit, refer to the MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide on the MegaRAID Universal Software Suite CD. For more information about the TMM02 module, refer to the Cache Backup Products for MegaRAID SAS+SATA RAID Controllers User Guide on the MegaRAID Universal Software Suite CD. The following figure shows the MegaRAID SAS 9286-8e RAID controller. Figure 1 MegaRAID SAS 9286-8e RAID Controller - 3 -

NOTE Record your controller serial number in a safe location in case you need to contact LSI. NOTE This RAID controller supports SATA I, SATA II, and SATA III technologies. 2 Controller Installation CAUTION Back up your data before changing your system configuration. Otherwise, you might lose data. 1. Unpack the RAID Controller Unpack the RAID controller in a static-free environment. Remove it from the antistatic bag, and inspect it for damage. If the RAID controller appears to be damaged, or if the MegaRAID Universal Software Suite CD is missing, contact LSI or your MegaRAID OEM support representative. The CD contains utility programs, device drivers for various operating systems, and the following documentation: 6Gb/s MegaRAID SAS RAID Controllers User Guide MegaRAID SAS Software User Guide MegaRAID SAS Device Driver Installation User Guide Cache Backup Products for MegaRAID SAS+SATA RAID Controllers User Guide MegaRAID LSIiBBU09 Intelligent Battery Backup Unit Quick Installation Guide Software license agreement 2. Prepare the Computer Turn off the computer, and unplug the power cords from the rear of the power supply. Remove the cover from the computer. CAUTION Before you install the RAID controller, make sure that the computer is disconnected from the power and from any networks. 3. Review the Jumpers and the Connectors The following figure shows the location of the jumpers and the connectors on the RAID controller. The jumpers are set at the factory, and you usually do not need to change them. - 4 -

Figure 2 Layout of the MegaRAID SAS 9286-8e RAID Controller J1A1 J1A2 J2A1 J2A3 J2A2 J4A1 J4A2 J5A2 J6A1 J1A3 J1B1 J5B1 J2B1 85082-00 NOTE Pin 1 on the headers and connectors is highlighted in red in the previous figure. The following table describes the jumpers and the connectors on the MegaRAID SAS 9286-8e RAID controller. Table 1 Jumpers and Connectors Jumper/ Connector Type Description J1A1 Write pending LED header 2-pin connector Connects to an LED that indicates when the data in the +ve -ve cache has yet to be written to the storage devices. Used when the write-back feature is enabled. a k J1A1 J1A2 Global drive fault LED header 2-pin connector Connects to an LED that indicates whether a drive is in a +ve -ve fault condition. a k J1A2 J1A3 x4 SAS Ports 0-3 external connector SFF-8088 x4 external mini SAS connector Connects the controller by cable to SAS drives or SATA drives. J1B1 x4 SAS Ports 4-7 external connector SFF-8088 x4 external mini SAS connector Connects the controller by cable to SAS drives or SATA drives. - 5 -

Table 1 Jumpers and Connectors Jumper/ Connector Type Description J2A1 Activity LED header 2-pin connector Connects to an LED that indicates activity on the drives connected to the controller. +ve a -ve k J2A2 I 2 O Mode jumper 2-pin connector Installing this jumper causes the RAID controller to run in I 2 0 mode. The default mode of operation is without the shunt and running in Fusion Mode. J2A3 J1A4 Advanced Software Options Hardware Key header 3-pin header Enables support for the Advanced Software Options features, which include CacheCade, FastPath, Recovery, and SafeStore disk encryption. J2B1 Standard edge card connector The RAID controller interfaces with the host system though a standard edge card. This interface provides power to the board and an I 2 C interface connected to the I 2 C bus for IPMI. J4A1 Serial EEPROM 2-pin connector Provides controller information, such as the serial number, revision, and manufacturing date. The default is no shunt installed. 4. Install the RAID Controller Insert the controller into a PCI-Express slot on the motherboard, as shown in the following figure. Press down gently, but firmly, to seat the card correctly in the slot. Secure the RAID controller to the computer chassis with the bracket screw. NOTE This controller is a PCI-Express x8 card and it can operate in x8 or x16 slots. However, some PCIe slots support only PCIe graphics cards; if a RAID controller is installed, it does not function. NOTE Refer to the guide for your motherboard for information about the PCI-Express slot. - 6 -

Figure 3 Installing the MegaRAID SAS 9286-8e RAID Controller Press Here Screw Press Here 85082-01 PCI Socket Edge of Motherboard 5. Configure and Install the SAS Devices, SATA Devices, or Both in the Host Computer Case Refer to the documentation for the devices for any preinstallation configuration requirements. 6. Connect the RAID Controller to the SAS Devices, SATA Devices, or Both in the Host Computer Case Use SAS cables to connect the RAID controller to SAS devices, SATA devices, or both. See Figure 2 to view the connector locations. NOTE Refer to the 6Gb/s MegaRAID SAS RAID Controllers User Guide on the MegaRAID Universal Software Suite CD for detailed information about the SAS cables. 7. Turn on the Power to the Computer Reinstall the computer cover, and reconnect the power cords. Turn on the power to the computer. Make sure that the power is turned on to the SAS devices and the SATA devices before or at the same time that the power to the host computer is turned on. If the power is turned on to the computer before it is turned on to the devices, the computer might not recognize the devices. The firmware takes several seconds to initialize. During this time, the controller scans the ports. 8. Run the WebBIOS Configuration Utility Run the WebBIOS Configuration Utility to configure the groups and the virtual drives. When the message Press <Ctrl><H> for WebBIOS appears on the screen, immediately press CTRL+H to run the utility. NOTE Refer to the MegaRAID SAS Software User Guide for detailed steps on configuring groups and virtual drives. - 7 -

9. Install the Operating System Driver The controller can operate under various operating systems, but you must install the software drivers first. The MegaRAID Universal Software Suite CD includes the software drivers for the supported operating systems, along with documentation. You can view the supported operating systems and download the latest drivers for RAID controllers from the LSI website. Click the support button to access the download center, and follow the steps to download the driver. Refer to the MegaRAID SAS Device Driver Installation User Guide on the MegaRAID Universal Software Suite CD for more information about installing the driver. Be sure to use the latest service packs that are provided by the operating system manufacturer and to review the readme file that accompanies the driver. 3 Supported RAID Levels This RAID controller supports drive groups using the following RAID levels: RAID 0 (data striping): Data is striped across all drives in the group, enabling very fast data throughput. There is no data redundancy. All data is lost if any drive fails. RAID 1 (drive mirroring): Data is written simultaneously to both drives in the drive group, providing complete data redundancy if one drive fails. RAID 1 supports an even number of drives from 2 to 32 in a single span. RAID 5 (drive striping with distributed parity): Data is striped across all drives in the group. Part of the capacity of each drive stores parity information that reconstructs data if a drive fails. RAID 5 provides good data throughput for applications with high read request rates. RAID 6 (drive striping with distributed parity across two drives): Data is striped across all drives in the group and two parity drives are used to provide protection against the failure of up to two drives. In each row of data blocks, two sets of parity data are stored. RAID 10 (RAID 1 and RAID 0 in spanned groups): RAID 10 uses mirrored pairs of drives to provide complete data redundancy. RAID 10 provides high data throughput rates. RAID 50 (RAID 5 and RAID 0 in spanned groups): RAID 50 uses both parity and drive striping across multiple drives to provide complete data redundancy. RAID 50 provides high data throughput rates. RAID 60 (RAID 6 and RAID 0 in spanned groups): RAID 60 uses both distributed parity across two parity drives and drive striping across multiple drives to provide complete data redundancy and high fault tolerance. NOTE Refer to the MegaRAID SAS Software User Guide on the MegaRAID Universal Software Suite CD for more information about RAID levels. - 8 -

4 Technical Support For assistance in installing, configuring, or running the MegaRAID SAS 9286-8e RAID controller, contact an LSI Technical Support representative. Click the following link to access the LSI Technical Support page for storage and board support: http://www.lsi.com/support/storage/tech_support/index.html From this page, mouse-over the Support heading and select the support option you want. Email Requests: http://www.lsi.com/support/email/pages/megaraid.aspx Support Requests: http://www.lsi.com/support/pages/submitsupportrequest.aspx Phone Support: http://www.lsi.com/support/pages/call-us.aspx Documents and Downloads: http://www.lsi.com/support/pages/downloads.aspx?k=* - 9 -