NI 653x Cable Adapter

Similar documents
NI SMB-2145/2146/2147/2148

INSTALLATION INSTRUCTIONS LFH160 Cable

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

You need the following to set up and use your terminal block:

Getting Results with the NI PXI-6585R

LabVIEW DSP Module. Contents. Introduction RELEASE NOTES. Version 1.0

Getting Started with R Series Intelligent DAQ

Getting Started with R Series Multifunction RIO

NI 6521 Specifications

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

Caution Electrostatic discharge can damage your controller. To avoid such damage, handle the controller only in a proper ESD-controlled environment.

Calibrating FieldPoint Analog Input Modules with Calibration Executive

Getting Results with the NI 5752R

NI 9213 Calibration Procedure

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

LabVIEW DSP Module Release and Upgrade Notes

NI SD Card Memory Module

FP-PS-4. Features. Installation

Getting Started with NI-Motion for NI 73xx Motion Controllers

NI SPEEDY-33. '7 NATIONAL INSTALLATIONGUIDE. P~ClCl J ~ Ig~~!1 "INSTRUMENTSN. 1~~~~~~g~~lm.OOOQ{JOOO,

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

Compact FieldPoint cfp-cal

Sample. LabWindows TM /CVI TM Core 1 Exercises Manual

NI 6584R User Guide and Specifications

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sinking Digital Input Device

NI CardBus-8310-to-PXI Expansion Kit

Sample. LabWindows TM /CVI TM Core 1 Course Manual

TBX-96 TERMINAL BLOCK

QUICK START GUIDE. What You Need to Get Set Up

USER GUIDE Universal Motion Interface (UMI)-7764

For NI PXI and NI SCXI Switch Modules

Power Analyzer Firmware Update Utility Version Software Release Notes

FP-AO-210 AND CFP-AO-210

Sample. LabVIEW TM Core 1 Exercises. Course Software Version 2010 August 2010 Edition Part Number B-01. LabVIEW Core 1 Exercises

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 24 V Logic, Sourcing Digital Output Device

SCXI HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK

FP-AO-200 AND CFP-AO-200

NI Channel, 0 20 ma, 16-Bit Analog Current Output Module

Getting Started with the NI 8234

VME-GPIB Installation and User Guide

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

NI CAN Demo Box. NI CAN Demo Box User Guide. Power supply (+9 VDC to +12 VDC) 68-pin Multifunction Data Acquisition board

Compact FieldPoint cfp-1808

Getting Started with the NI PCIe-8253

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, 0 20 ma, 16-Bit Analog Current Output Module

SCB-68 User Guide. 68-Pin Shielded Desktop Connector Block

Getting Started with the NI PCIe-1433

SH Cable Specifications

FP-AIO-600 and cfp-aio-600

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

Getting Started with the NI PXI/PCIe-8231

Getting Started with the NI 8234

Bracket and Mounting Dimensions

Getting Started with the NI PCIe-8235

Electromagnetic Compatibility Guidelines

NI High-Speed Digitizers

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

Instructions. (For 6180 Industrial Computers) Applications. Overview & Safety

CALIBRATION PROCEDURE NI PXIe Channel, Isolated Voltage/Current Analog Output Module

Instructions. (For 6180 Industrial Computers) Installing a Processor Upgrade

NI Digital Waveform Generator/Analyzer

NI USB-9201/9221. Introduction USER GUIDE AND SPECIFICATIONS. 8-Channel, 12-Bit Analog Input Devices

Using Measurement & Automation Explorer (MAX) with VXI

NI PXI Contents CALIBRATION PROCEDURE

Getting Started with the NI PCIe-8255R

NI PCIe-8255R Quick Start Guide

Electrical. SPECIFICATIONS SH Cable

FP-2000/2010 FieldPoint Quick Start Guide

Getting Started with the NI PCI-1405

NI High-Speed Digitizers

Safety. Introduction

Getting Started with the NI LabVIEW Embedded Module for ADI Blackfin Processors Version 8.6

Getting Started with the NI PCI-8254R

AC/DC (120V) Input Module Cat. No IAD Series C

CompactRIO Reconfigurable Embedded Chassis

FieldPoint cfp-21xx. Quick Start Guide. What You Need to Get Set Up

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

The NI TB-2648/2649/2650/2651 terminal blocks configure your NI PXI/PXIe-2531 (NI 2531) in one of the following topologies. 1-wire 8 64 matrix

Contents. Software Requirements. CALIBRATION PROCEDURE NI PXIe-4357

CALIBRATION PROCEDURE CAL Contents. Software

NI USB-6211/6218 OEM

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

LabVIEW DataFinder Toolkit

CB-27T, TBX-68T, AND CB-68T ISOTHERMAL TERMINAL BLOCKS INSTALLATION GUIDE

NI 5761R User Guide and Specifications

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

NI PXIe-6555/6556. Contents GETTING STARTED GUIDE. 200 MHz Digital Waveform Generator/Analyzer with PPMU

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

Getting Started with the NI PXI/PCI-1422

NI 6520/6521. Contents USER GUIDE

NI PXIe-6544/6545/6547/6548

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

Contents. Software CALIBRATION PROCEDURE NI TC-4353

Transcription:

USER GUIDE NI 65x Cable Adapter Contents The NI 65x cable adapter interfaces with National Instruments high-speed digital I/O (DIO) devices. The cable adapter provides an easy way to connect the Very High Density Connector Interface (VHDCI) connectors, labeled as Digital Data & Control, on the newer NI 655/656/657 devices to the 68-pin DAQ connectors found on older NI 65/65 accessories and fixturing. The 65x cable adapter is also compatible with the NI 65x and NI 655x digital pattern generator/analyzer devices. For best signal integrity, NI recommends using the NI 655/656/657 devices with newer accessories such as the NI CB-6 and NI SMB-6. This guide explains how to set up and use the NI 65x cable adapter. What You Need to Get Started... Related Documentation... Parts Locator Diagram... Installing Cables... Removing the NI 65x Cable Adapter from its Enclosure... 5 Connecting Signals... 6 Custom Wiring Example... Specifications... Digital I/O... Traces... Power... Physical... Where to Go for Support...

What You Need to Get Started Related Documentation To set up and use the NI 65x cable adapter, you need the following items: NI SHC68-C68-D or NI C68-C68-D cable assembly (for NI 655/656/657/65x/655x devices) Compatible NI high-speed digital I/O device (NI 655/656/657/65x/655x) (Optional) - to 6-gauge wire (Optional) The documentation included with the NI high-speed DIO device and the driver software included with your device (Optional) NI 65 or NI 65 supported terminal block National Instruments high-speed DIO devices ship with several documents designed to familiarize you with different aspects of the device. The titles and location of the documents vary based on the driver that supports the NI device, but you should have the following types of documentation: Getting Started Guide This printed document should be the first thing you read. Its purpose is to guide you through setting up the high-speed DIO device and configuring it to generate or acquire your first samples. Help This online document provides more in-depth information about the hardware capabilities of the high-speed DIO device, theory of operation discussion, and information on programming flow and software reference. Specifications This printed document provides specifications for the NI hardware. Visit ni.com/manuals for the most current documentation. You also may have documentation for any application development environment (ADE) you are using. NI 65x Cable Adapter User Guide ni.com

Parts Locator Diagram Refer to Figure to locate connectors and components on the NI 65x cable adapter. 8 7 5 6 Remove screws on this side of enclosure to access terminals. 65X CABLE ADAPTER NATIONAL INSTRUMENTS Enclosure Base Jacksockets (M.5 Screw, #-56 Socket) 68-Pin DAQ Connector Enclosure Top Cover 5 M.5 x 6 mm Philips Flathead Countersunk Screws 6 Terminal Connectors 7 VHDCI Connector 8 #-56 Custom Screw Figure. NI 65x Cable Adapter Parts Locator Diagram National Instruments Corporation NI 65x Cable Adapter User Guide

Installing Cables An SHC68-C68-D or C68-C68-D cable connects the NI 65x cable adapter to the NI high-speed DIO device. Figure shows how to install the cable. DIGITAL DATA & CONTROL NI PCIe- 65x NATIONAL INSTRUMENTS 65X CABLE ADAPTER Remove screws on this side of enclosure to access terminals. PC Chassis with NI High-Speed DIO Device Cable Assembly Cable Jackscrews NI 65x Cable Adapter Figure. Connecting a SHC68-C68-D or C68-C68-D Cable to the NI 65x Cable Adapter Caution Before connecting the cable, disconnect power from the NI device and any other connected hardware to prevent damage to the hardware and personal injury. NI is not liable for damage resulting from improper connections. Refer to Figure as you complete the following steps to install the cable adapter:. Insert the cable into the cable adapter.. Tighten the cable jackscrews. Caution Before attaching any cables or accessories, install the NI high-speed DIO device. Refer to the Getting Started Guide that shipped with your device for instructions on installing the device. NI 65x Cable Adapter User Guide ni.com

Removing the NI 65x Cable Adapter from its Enclosure You will need to remove the NI 65x cable adapter from its enclosure to connect signals. To remove the cable adapter from its enclosure, complete the following steps:. Remove the screws from the cable adapter enclosure top cover, as shown in Figure. NATIONAL INSTRUMENTS 65X CABLE ADAPTER Remove screws on this side of enclosure to access terminals. M.5 x 6 mm Philips Flathead Countersunk Screws Figure. Remove Screws from the Enclosure. Remove the enclosure top cover. Note Be sure to remove the screws from side with the NI logo label, as shown in Figure. National Instruments Corporation 5 NI 65x Cable Adapter User Guide

Connecting Signals The NI 65x cable adapter provides connectivity to up to of the single-ended DIO channels of an NI high-speed DIO device. Each DIO, PFI, and clock channel of the NI high-speed DIO device connects to a corresponding pin on the NI 65x cable adapter. The DIO channels are directly connected between the two bulk connectors. PFI <0..5> from the NI 655/656/657 VHDCI connector are connected to a 6-position screw terminal. PFI <0..7> from the NI 65/65 68-pin DAQ connector are connected to an 8-position screw terminal. PFI channels must be manually connected through screw terminals for flexibility and to ensure correct signal routing. You can make connections between the PFI channels using - to 6-gauge wire. The NI 65/65 devices have specific applications for PFI channels and thus require custom wiring to be compatible. An example of how to make these connections is provided in the Custom Wiring Example section. Figure shows the screw terminal locations on the NI 65x cable adapter. C 655/6/7 PFI 5 0 J J 65/ PFI 7 6 5 0 J +5V J W Figure. NI 65x Signal Connections NI 65x Cable Adapter User Guide 6 ni.com

Note Refer to the help file for your device for information about the number of available DIO channels on your device. DIO <0..> or PFI_0 may not be applicable to your device. Figures 5 and 6 show pinouts for the VHDCI connector and 68-pin DAQ connector, respectively. DIO DIO 9 DIO 7 DIO 5 RESERVED DIO DIO DIO 9 DIO 7 DIO 5 DIO DIO DIO 9 DIO 7 PFI DIO 5 DIO PFI DIO DDC CLK OUT/PFI_ 5 6 7 8 9 0 5 6 7 8 9 0 5 6 7 8 9 0 5 6 7 8 9 0 5 6 7 8 9 50 5 5 5 5 55 56 57 58 59 60 6 6 6 6 65 66 67 68 DIO 0 DIO 8 DIO 6 DIO DIO DIO 0 DIO8 DIO 6 DIO RESERVED/PFI_0 DIO DIO 0 DIO 8 DIO 6 RESERVED DIO DIO PFI DIO 0 STROBE/PFI_5 Figure 5. VHDCI Connector Pinout (NI SHC68-C68-D or NI C68-C68-D Cable) National Instruments Corporation 7 NI 65x Cable Adapter User Guide

+5 V PFI PFI 6 PFI 0 PFI PFI 5 PFI PFI 7 PFI P0.0 P0. P0. P0.7 P.0 P. R P.6 P.7 P.0 P. P. P.7 P.0 P. P. P.7 5 6 7 8 9 0 5 6 7 8 9 0 5 6 7 8 9 0 5 6 7 8 9 0 5 6 7 8 9 50 5 5 5 5 55 56 57 58 59 60 6 6 6 6 65 66 67 68 R D PULL C PULL R P0. P0. P0.5 P0.6 P. P. P. P.5 R P. P. P.5 P.6 P. P. P.5 P.6 Figure 6. 68-pin DAQ Connector (NI 65/65 Fixture or Accessory) NI 65x Cable Adapter User Guide 8 ni.com

Table describes the VHDCI signals shown in Figure 5. Table describes the DAQ connector signals shown in Figure 6. Table. VHDCI Connector Pinout Descriptions (NI 655/656/657/65x/655x) Pin Signal Description Connection DIO <0..> Bidirectional digital data channels 0 through. P0 <0..7>, P <0..7>, P <0..7>, or P <0..7> on a 68-pin DAQ connector PFI <0..5> Programmable functional interface (PFI) channels 0 through 5. 6-position screw terminal (J) Ground reference for signals. RESERVED These channels are reserved for system use. Do not connect signals to these channels. Note Refer to your device documentation for supported channels. Table. DAQmx Connector Pinout Descriptions (NI 65/65) Pin Signal Description Connection P0 <0..7> Bidirectional digital data port 0 channels 0 through 7. VHDCI DIO <0..7> P <0..7> Bidirectional digital data port channels 0 through 7. VHDCI DIO <8..5> P <0..7> Bidirectional digital data port channels 0 through 7. VHDCI DIO <6..> P <0..7> Bidirectional digital data port channels 0 through 7. VHDCI DIO <..> PFI <0..7> Programmable functional interface (PFI) channels 0 through 7. 8-position screw terminal (J) + 5 V DC power Unpopulated W C PULL, DPULL Power on state control NC Note The NI 655/656/657/65x/655x does not provide +5 V. If your fixtures require this, access to the +5 V signal on the DAQ connector is provided through the unpopulated W through-hole solder pad. National Instruments Corporation 9 NI 65x Cable Adapter User Guide

Caution Connections that exceed any of the maximum ratings for the NI 65x cable adapter or the NI high-speed DIO device can damage the device and the computer. Maximum input ratings are provided in the Specifications section and in the specifications document that shipped with the NI high-speed DIO device. NI is not liable for any damage resulting from such signal connections. Table shows the relationship between PFI channels and the termination sockets. Table. PFI Screw Terminals Connector Channel Socket VHDCI (NI 655/656/657/65x/655x) 68-Pin DAQ Connector (NI 65/65) PFI <0..5> PFI <0..7> J J Note Refer to the help file for your device for information about the number of available DIO channels on your device. DIO <0..> or PFI_0 may not be applicable to your device. NI 65x Cable Adapter User Guide 0 ni.com

Custom Wiring Example You can use different wiring schemes to connect the PFI channels in multiple configurations. This section describes a burst handshaking example using an NI 65x cable adapter to provide compatibility between an NI 65/65 and an NI 655/656/657 where the fixture is configured to work with the NI 65/65. Without changing the fixture setup, the adapter and software can be changed to maintain functionality. The NI 65x cable adapter can be configured using - to 6-gauge wire as shown in Figure 7. C 655/6/7 PFI 5 0 J J 65/ PFI 7 6 5 0 J +5V J W ACK/Ready for Transfer CLK OUT REQ/Pause Figure 7. Example Connectivity This custom wiring results in the signal assignments shown in the following table. Table. Example Connections PFI_0 PFI_ PFI_ VHDCI NI 655/656/657 68-Pin DAQ NI 65/65 PFI_ (REQ/Pause) PFI_6 (ACK/Ready for Transfer) PFI_ (CLK OUT) National Instruments Corporation NI 65x Cable Adapter User Guide

A burst handshaking example using the NI 65/65 can be coded in LabVIEW as shown in Figure 8. Figure 8. NI 65/65 Burst Handshaking Application Figure 9 shows the changes made to this LabVIEW VI to accommodate the NI 65x cable adapter connections and provide compatibility with the previous application using an NI 655/656/657 instead of an NI 65/65. Figure 9. NI 65x Burst Handshaking Application with NI 65x Cable Adapter and NI 655/656/657 (Changes Circled) NI 65x Cable Adapter User Guide ni.com

Specifications Digital I/O VHDCI DIO channels..., single-ended VHDCI control channels... 6, single-ended DAQ DIO channels..., single-ended DAQ control channels... 8, single-ended Traces Type... Matched length to 00 mils AC impedance... 50 Ω Power Physical Maximum voltage rating... 5.5 V Dimensions... 6.7 69. 6.7 mm (.7.7 0.66 in.) I/O connectors... 68-pin VHDCI connector, 6 position screw terminal, 8 position screw terminal, 68-pin DAQ connector Recommended wire gage... -6 AWG Recommended torque for screw terminals... 0. N-m (.7 lb-in) Recommended torque for cover screws... 0. N-m (.0 lb-in) Weight... 60 g (. oz) Caution When connected to other test objects, this product may cause radio interference. In a residential environment, the user may be required to take adequate measures to reduce the radio interference. National Instruments Corporation NI 65x Cable Adapter User Guide

Where to Go for Support The National Instruments Web site is your complete resource for technical support. At ni.com/support you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. National Instruments corporate headquarters is located at 500 North Mopac Expressway, Austin, Texas, 78759-50. National Instruments also has offices located around the world to help address your support needs. For telephone support in the United States, create your service request at ni.com/support and follow the calling instructions or dial 5 795 88. For telephone support outside the United States, contact your local branch office: Australia 800 00 800, Austria 0 66 5 79 90 0, Belgium0757000, Brazil556599, Canada 800 88, China 86 6555 788, Czech Republic 0 5 77, Denmark 5 5 76 6 00, Finland85097575, France08, Germany 9 0 89 7 0, India 9 80 90000, Israel 97 0 6977, Italy 9 0 09, Japan 8 57 970, Korea80500, Lebanon96088, Malaysia 800 88770, Mexico 0 800 00 079, Netherlands 0 8 66, New Zealand 0800 55, Norway 7 0 66 90 76 60, Poland 8 9050, Portugal 5 0 0, Russia 7 095 78 68 5, Singapore 800 6 5886, Slovenia 86 5 00, South Africa 7 0 805 897, Spain 9 60 0085, Sweden60858789500, Switzerland560055, Taiwan 886 0 77, Thailand 66 78 6777, United Kingdom 0 65 555 NI 65x Cable Adapter User Guide ni.com

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 006 National Instruments Corporation. All rights reserved. 75A-0 Aug06