Interested in conducting your own webinar?

Similar documents
Retro-Commissioning of Data Centers

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Los Anseles W Department of 5* Water & Power

GREEN POWER FOR MOBILE TELECOMS OUTSOURCING POWER NEEDS TO AN ESCO IS EAST AFRICA TELECOMS READY FOR THE ESCO MODEL?

FY18 FULL-YEAR RESULTS 31 AUGUST 2018 NEXTDC LIMITED ACN

Trading TCO for PUE? A Romonet White Paper: Part I

Achieving Operational Excellence

Building Efficiency as a Service

How High-Density Colocation and Enhanced Visibility Improve Business Performance

DATA CENTER COLOCATION BUILD VS. BUY

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Server room guide helps energy managers reduce server consumption

Data Center Energy Savings By the numbers

ROI CASE STUDY MAY Logicalis Achieves 159% ROI* with CA DCIM Solution

Today s Webcast starts at 1:00 p.m. Eastern. You will not hear audio until the Webcast begins

MSYS 4480 AC Systems Winter 2015

Continuity Insights Chicago: Evolving Data Center Trends & Design Standards. 19 June Jose Hernandez, 30+ years of design/build experience

Red Hat Virtualization Increases Efficiency And Cost Effectiveness Of Virtualization

PLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy

The End of Redundancy. Alan Wood Sun Microsystems May 8, 2009

Why would you want to use outdoor air for data center cooling?

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Constru January 15, 2013

Building Management Solutions. for Data Centers and Mission Critical Facilities

1.0 Executive Summary. 2.0 Available Features & Benefits

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

HPE Energy Efficiency Certification Service

Scalable, Secure. Jason Rylands

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Discover the Hidden Cost Savings of Cloud Computing

Greening Terremark Data Centers

Maximising Energy Efficiency and Validating Decisions with Romonet s Analytics Platform. About Global Switch. Global Switch Sydney East

Making the impossible data center a reality.

Hot vs Cold Energy Efficient Data Centers. - SVLG Data Center Center Efficiency Summit

Verizon Perspectives on Smart Infrastructure. Anthony J. (Tony) DiMaso Advanced Energy Conference November 19, 2009

Investor day. November 17, IT business Laurent Vernerey Executive Vice President

November/December 2011

Federal Data Center Consolidation Initiative (FDCCI) Workshop I: Initial Data Center Consolidation Plan

18 th National Award for Excellence in Energy Management. July 27, 2017

Executive Summary. Zuma Engineering and Research. Data Center Virtualization Assessment. Service Description

Data Center Carbon Emission Effectiveness

EUROPEAN DATA CENTRE STANDARDS

FY18 HALF-YEAR RESULTS 23 FEBRUARY 2018 NEXTDC LIMITED ACN

Global Trend and Challenges to Internet Data Centre: High Energy Efficiency Strategies

Green IT Project: The Business Case

Energy Performance Contracting

Most likely, your organization is not in the business of running data centers, yet a significant amount of time & money is spent doing just that.

Columbus delivers 52% growth in revenue

ANCIS I N C O R P O R A T E D

FY16 Results Presentation. 24 January 2017

Data Center UPS Systems Why 1% Efficiency Matters

The Case for Virtualizing Your Oracle Database Deployment

DCIM Data Center Infrastructure Management Measurement is the first step

DCIM Solutions to improve planning and reduce operational cost across IT & Facilities

Welcome Association of Energy Engineers to the Microsoft Technology Center

Green IT and Green DC

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

It s practically a cliché, but

INT 492 : Selected Topic in IT II (Data Center System Design) 3(3-0-6)

Ecolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001

Cooling Solutions & Considerations for High Performance Computers

THE CURRENT STATE OF DATA CENTER ENERGY EFFICIENCY IN EUROPE. White Paper

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Dell EMC Hyper-Converged Infrastructure

HPC Solutions in High Density Data Centers

Case Study: The design of a modern data centre Jeffrey Brindle Technical Director, HP Critical Facilities Services

Data Center Infrastructure Management (D.C.I.M.)

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

DATACENTERS - IDENTIFYING COMMON PROPERTY TAXATION ISSUES OF AN EVOLVING PROPERTY TYPE

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

Total Cost of Ownership

Google s Green Data Centers: Network POP Case Study

Data center redundancy. Air traffic High-speed pipes. Training Design. Costs. Guy with a wrench. Terrorism

San Francisco Chapter. What an auditor needs to know

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Architecting for Data Center Agility. Ted Ritter Senior Research Analyst

Nominee: Prefabricated, Pre Assembled Data Centre Modules by Schneider Electric

UNIX Server Optimization With TCO and ROI Analysis

Management Update: Storage Management TCO Considerations

Analyst Presentation Half year results July 2007

Factsheet. Power Generation Service Energy efficiency in power generation and water

OpEx Drivers in the Enterprise

Cereal Hudson. Tariffs. Anthony S. Campagiorni, Esq. Vice President, Regulatory & Governmental Affairs. Requested Revenue Increases

Partner Introduction

Green Computing and Sustainability

Data Center Energy and Cost Saving Evaluation

Annual Report for the Utility Savings Initiative

Powering Transformation With Cisco

ESPC Overview. Definition and Need. Program Description. Questions and Answers. Curt Murdock & Rod Bridgeman August 6

DCIM Data Center Infrastructure Management

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Data Centers. The Environment. December The State of Global Environmental Sustainability in Data Center Design

SIX Trends in our World

Presentation. Guaranteed Energy Savings Performance Project

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime

Your data center s hidden source of revenue

Transcription:

Interested in conducting your own webinar? Email webinars@bnpmedia.com

July 17, 2012 TCO in the Data Center

Audio Abstract Presenter Info Slides Handouts Group Chat Q & A Live Twitter Feed Help Survey Archive www.missioncriticalmagazine.com Add to your favorites

July 17, 2012 TCO in the Data Center

CONSULT + ENGINEER + COMMISSION Mission Critical 7x24 Exchange Webinar Presented by Cyrus J. Izzo, PE Co-President, Syska Hennessy Group, Inc. July 17, 2012 All Rights Reserved www.syska.com

CONSULT + ENGINEER + COMMISSION Agenda Key Industry Trends TCO Concept IT Operations Design of Modern Data Centers Changing End User Requirements Questions and Answers www.syska.com

CONSULT + ENGINEER + COMMISSION Key Industry Trends Do more with less Economic trend = fewer IT, Operational and Facilities Staff Focus on growing Data Center Efficiency Optimizing Power Usage Effectiveness (PUE) Increase critical load density Reduce resource consumption Increased awareness of TCO (Total Cost of Ownership) www.syska.com

CONSULT + ENGINEER + COMMISSION TCO Concept Why is it becoming more important? Managing operations with restricted budgets Manage OPEX and balance CAPEX to optimize long-term financial impact www.syska.com

CONSULT + ENGINEER + COMMISSION Site Selection Design CAPEX Manage & Operate TCO OPEX Construct Commission & Turnover www.syska.com

CONSULT + ENGINEER + COMMISSION TCO Concept effect on IT Operations Lowering TCO and making the right decisions for IT Operations Should we build, operate, and own our own facility OR Outsource and colocate our data center? www.syska.com

CONSULT + ENGINEER + COMMISSION TCO Concept effect on IT Operations Largest capital expenditure is site infrastructure - 70% is operating expenses and energy costs, the balance is actual IT equipment Options to allow IT staff to focus on projects rather than operational support Colocation Outsourcing Cloud computing Various industries are following different strategies www.syska.com

CONSULT + ENGINEER + COMMISSION TCO Concept effect on Design of Modern Data Centers Site Selection Design choices Energy efficient design and modeling tools Time and resource commitment necessary for OPEX opportunities Future state www.syska.com

CONSULT + ENGINEER + COMMISSION Changing End User Requirements Smarter, faster and cheaper Zero tolerance for downtime Clients are interested in modular buildouts build what you need, as you need it just in time Focus on emerging opportunities and retaining clients New baseline: Uptime and Reliability www.syska.com

CONSULT + ENGINEER + COMMISSION Changing End User Requirements ASHRAE expanding the range for IT equipment thermal envelope allows us to accept new opportunities for efficient design Figure 2. ASHRAE Environmental Classes for Data Centers www.syska.com 2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. All Rights Reserved

CONSULT + ENGINEER + COMMISSION Changing End User Requirements Design should provide a robust model to help: Operate and maintain facilities over lifetime With less staff At lower cost With the tools necessary to succeed www.syska.com

Total Cost of Ownership Terry Rennaker Skanska Mission Critical COE Mission Critical Magazine July 17, 2012

Agenda Identify the costs Expand the boundaries Identify the target you are solving for

18 Identify the costs

Identify the cost Costs are often siloed IT Costs Energy Capital Labor Maintenance Other Utilities (gas, water, sewer, etc.) Life of system

Identify the cost Capital and expense Direct capital cost Cost of space Depreciation annual/remaining Cost of capital Energy Time of day Demand Power source Other utilities Gas Water/Sewer Carbon tax

Identify the cost Labor Facility operations IT operations Maintenance Internal maintenance labor External/vendor maintenance Life of system IT

22 Expand the boundaries

Expand the boundaries Offsite Entire Facility Exterior Back of house White space Power supply Generators Energy Storage UPS Power distribution Racks Servers CRAC Cooling Towers Chillers Other facilities Other facilities Other facilities

24 Identify the target

Identify the target you are solving for What is important to your organization?

Identify the target you are solving for First Cost Operating Cost P&L Impact Balance Sheet Impact Payback Period Environmental

Identify the target you are solving for First cost Avoided capital expense If you spend this you avoid Operating cost reduction Energy Utilities Labor Maintenance Balance sheet Accepted term of payback

Identify the target you are solving for P&L impact Generally Accepted Accounting Principles (GAAP) Depreciation is an expense Capital vs Operating lease (FAS 13 tests) 1) There can be no ownership transfer as part of the lease agreement. 2) Does the purchase option cannot constitute a bargain as defined by FAS-13. 3) Lease term must be less than the useful life of the asset 4) The net present value of the rent cannot exceed 90% of the Fair Market Value of the asset 5) The lease term must be less than 75% of the remaining economic life of the asset

Identify the target you are solving for Accepted measurement Net Present Value (NPV) Return on Investment (ROI) Return on Equity (ROE) EBIT EBITDA Environmental LEED Energy efficiency Water efficiency Carbon impact

Conclusion Identify the costs Expand the boundaries Identify the target you are solving for

Type your question in the box and hit submit