SmartZone Gateway- Enabled M Series Rack PDU

Similar documents
Panduit Basic Rack PDU with Local Meter

Panduit Basic Rack PDU

G5 PDU Installation Guide

SmartZone Network-Enabled MS Series Rack PDU

HPE Intelligent Power Distribution Unit Installation Instructions

* * Agilent Power Distribution Unit (PDU) Installation Guide

Cube Camera with Fixed Lens Hardware Manual D11, D12. Ver. 2013/05/17

BCM2 Series Branch Circuit Monitors Quick Setup Guide

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

Fixed Network Camera Hardware User Manual

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

D12. 1MP Cube with Fixed lens Hardware User s Manual. (PoE) Ver. 2013/05/07

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

Broadband Automatic Disconnect Switch. User Manual

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

Leased-Line Extenders over IP

LVN5200A-R2, rev. 1, Hardware Installation Guide

hp uninterruptible power system r12000 xr models installation instructions

Indoor Mini Dome. Hardware Manual D91, D92, E91, E92. Ver. 2013/06/14

Installing and Configuring Rialto Analytic Appliances

Metro-Optical Transport Access Nodes

PM Series Power Meter

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit

OWC Mercury On-The-Go Pro USER GUIDE

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

InnoMedia Business VoIP ATA Models

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

ENCELIUM EXTEND Manager Wiring and installation manual Light is OSRAM

B-33. Hardware and Install Manual. (DC 12V / PoE)

E92. Hardware User s Manual. 3MP Indoor Mini Dome with Basic WDR, Fixed lens. (PoE) Ver. 2013/02/04

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

Mercury Elite Pro mini ASSEMBLY MANUAL & USER GUIDE

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Model HM-535 Power Supply Installation and Service Instructions

Installation Manual. Alpha 4000 RGB Signs. Before you begin

ENVOY PRO. Assembly Manual & User Guide

DRIVE DOCK. User Guide

Instruction Manual Basic Rack PDU VP7541 and VP9571A

DRIVE DOCK. User Guide

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

TABLE OF CONTENTS INTRODUCTION...1 DEVICE SETUP...4 SUPPORT RESOURCES...9

EXPRESS. Assembly Manual & User Guide

MERCURY PRO. Assembly Manual & User Guide

Power Xpert Meter 2000 Gateway Card Kit

Safety Precautions Legrand PDU. 0U PDU Overview. Outlets. Circuits. Controller with Connector Ports: See Controller (on page 4).

Voyager S3. User guide

Envoy Pro ASSEMBLY MANUAL & USER GUIDE

OWC Mercury Elite Pro Dual mini ASSEMBLY MANUAL & USER GUIDE

OWC Mercury Pro Optical ASSEMBLY MANUAL & USER GUIDE

THUNDERBAY 4 MINI. Assembly Manual & User Guide

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

Auto-Transfer Rack Power Distribution Unit

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

User Manual. Per Port Monitoring Models

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

Documentation on all Paxton products can be found on our web site -

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Instruction Manual. Rack PDU XP Series. geistglobal.com

Fixed Network Camera Hardware User Manual

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

MT /12-Slot Digital MultiTasker

INSTALLATION INSTRUCTIONS

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

G.SHDSL NTU DECEMBER 2006 LB510A

MC 11 EB-2 Power supply cabinet with external bus, AC version

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

Installation and Configuration Guide

Switched Rack Power Distribution Unit

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

hdpv.org Ampt Communications Unit Installation Manual D

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

Allworx 24x Service and Troubleshooting Guide

Manual Version: V1.00. Video Decoder Quick Guide

Instruction Manual Rack In-Line Power Measurement Unit. L Series

DRIVE DOCK. User Guide

NI PXIe-1062Q Power Supply Shuttle

TCD channel H.264 Video Encoder Hardware User s Manual (DC 12V) Ver. 2010/10/29

Version /11/2015. User Manual. PowerLine AV HD Gigabit Passthrough Kit DHP-P601AV

Installation of the PCMeasure Movement Sensor (30114)

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

Perle MCR200 Installation Guide

Power Supply Installation

ENVOY. Assembly Manual & User Guide

Assembly Instructions

Disclaimer. Note that the Midspan is designed for indoor use only.

PR3400 Series 1.4Mp USB Cameras Hardware Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Installing the Cisco MDS 9020 Fabric Switch

Model 2380 Rack-Mount Kit

High Power over Ethernet Midspans PD Port Model PD Port Model

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

Transcription:

SmartZone Gateway- Enabled M Series Rack PDU User Manual Release 1.0 Issue 1.0

Copyright 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording or otherwise, without written permission from Panduit. No patent liability is assumed with respect to the use of the information contained herein. Although every precaution has been taken in the preparation of this book, Panduit assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein. - 2 -

Table of Contents SmartZone Gateway-Enabled M Series Rack PDU 4 Contacting Panduit 4 Symbols Used 4 Equipment Overview 6 Box Contents 6 Cable Details 6 Model Numbers 7 Pre-Installation 8 Installation 9 Product Inspection 9 Plug Connection 9 Hardwiring 9 Vertical Mounting 10 Horizontal Mounting 12 SmartZone 1RU Inline Meters 12 Optional Accessories 13 Additional Required Items 14 Safety Precautions 14 Servicing 14 Product Safety Warnings 14 Rules 15 Environmental Specifications 16 Bonding 16 Hardware 17 LCD Display 17 Reset Button 17 Mode Button Operation 18 Bootloader Startup 18 Firmware Recovery Mode 18 Application Startup 18 Internal Error Notification 19 Gateway User Interface 20 Access the PDU Graphical User Interface 20 Using the PDU Graphical User Interface 21 Appendix A - Temperature Sensor Adapter Installation 22 New Installations 22 Existing Installations. 23 Fitting the Adapter In-line. 23-3 -

SmartZone Gateway-Enabled M Series Rack PDU Gateway-Enabled M (Monitored) Series PDUs manage and distribute power to multiple power devices through a single power connector. This PDU allows you to access, configure, and manage power consumption and environmental parameters from remote locations. The M Series PDU monitors per-phase power, voltage and current, as well as perbranch current. SmartZone Gateway-Enabled PDUs are available in a wide range of configurations and power connections and outlets and can be mounted vertically or horizontally. Contacting Panduit For Technical Support on PDU hardware and associated software, please contact Panduit Technical Support using one of the following methods: 1-866-721-5302 (toll-free) Monday-Friday, 7:30 am - 5:00 pm CST systemsupport@panduit.com Symbols Used Symbol Description Danger Electric Shock Hazard Warning Possible Safety Hazard Primary Earth Ground - 4 -

Symbol Description Secondary Earth Ground ON O OFF - 5 -

Equipment Overview The power inlet/cord(s) connects the PDU to the electrical power source. The LCD displays the current load for each input feed or electrical phase per input feed. Box Contents The SmartZone Gateway-Enabled Rack PDU box contains the following: Gateway-Enabled Rack PDU Configuration Cable CD Mains Adapter External Grounding Stud Cable Details 63A single and three phase feed cable 10mm² (0.40 inches²) conductors: HO7 cable type terminated with (1P) 3-pin 63A commando and (3P) 5-pin 63A commando (IEC60309) 32A single and three phase feed cable 6.0mm² (0.23 inches²) conductors: HO7 cable type terminated with (1P) 3-pin 32A commando and (3P) 5-pin 32A commando (IEC60309) 16A single and three phase feed cable 2.5mm² (0.10 inches²)conductors: HO7 cable type terminated with (1P) 3-pin 16A commando and (3P) 5-pin 16A commando (IEC60309) 13A single phase feed cable 1.5mm² (0.06 inches²): HO7 cable type terminated with 3-pin UK plug 10A single phase feed cable 1.0mm² (0.04 inches²): HO7 cable type terminated with 3-pin IEC C14 Plug For IEC C-20 inlet PDUs, a customer-supplied cord is used for connection to the power source. The connection end to the PDU has an IEC C-19 plug for connection to the PDU. The opposite end of the cord shall have a plug suitable for connecting to the customer supplied receptacle. The cord and plug shall be rated for 20A in North America and 16A outside of North America. The connection to the PDU should be made prior to connecting to the power source - 6 -

Model Numbers The following table lists the specifications for the Gateway-Enabled Rack PDU model numbers. Horizontal HC-wwwVxxA HD-wwwVxxA HL-wwwVxxA HM-wwwVxxA HP-wwwVxxA HS-wwwVxxA Vertical VC-wwwVxxA VD-wwwVxxA VL-wwwVxxA VM-wwwVxxA VP-wwwVxxA VS-wwwVxxA IQ Adapter IM-wwwVxxA IL-wwwVxxA Single Inline GM-wwwVxxA GL-wwwVxxA Dual Inline LM-wwwVxxA LL-wwwVxxA Quad Inline AM-wwwVxxA AL-wwwVxxA Under the Floor UM-wwwVxxA In the tables above, www is the voltage for single phase or 3-phase and xx is the possible current associated with the voltage. Refer to the chart below for valid International and U.S. values. International U.S. Voltage Current Voltage Current 240, 415 10, 13, 16, 20, 30, 32, 48, 63 120, 208 15, 20, 30, 50, 60, 80-7 -

Pre-Installation The Gateway-Enabled Rack PDU products covered by this guide are designed to be installed within EIA racks and cabinets. Use of this product in other applications is acceptable, but other precautions may be required to allow for specific installations not covered by this guideline. - 8 -

Installation The Gateway-Enabled Rack PDUs are designed to be installed within 19 rack cabinets. Use of this product in other applications is acceptable, but other precautions may be required to allow for specific installations not covered here. Product Inspection Before installing your PDU, ensure that it has been inspected. If the product has any visible signs of damage please contact Panduit customer support at 800-777-3300 or cs@panduit.com. Please register your product to receive notification of firmware and product updates at: http://bit.ly/1axkhr1 Plug Connection This product is intended to be connected by the customer and must be installed by a competent person in compliance with all local and national regulations. Hardwiring This product is intended to be hardwired by the customer. It must be installed by a qualified electrician in compliance with all local and national regulations. 1. To install the power cable, remove the securing screws on the removable user panel. 2. Connect the conductors to the rack PDU terminals, in line with the terminal markings provided. - 9 -

3. Ensure that the cover is replaced and secure before commissioning. Vertical Mounting Panduit recommends using the provided external grounding stud for supplementary ground bonding to the rack metalwork. 1. Insert the tool-less mounting buttons into the fixing holes on the back of the rack- /cabinet. 2. Install the PDU using the bracket mounting buttons and the mounting brackets located at either end of the PDU. - 10 -

- 11 -

Horizontal Mounting To mount this product horizontally, use the RU mountings via the brackets found at either end of the PDU with the provided accessory screws, listed below. Horizontal Models North American units (4) #10-32 x 1/2 MOUNTING SCREWS (4) #12-24 x 1/2 MOUNTING SCREWS Global units (4) M6 x 20mm MOUNTING SCREWS (4) #12-24 x 1/2 MOUNTING SCREWS SmartZone 1RU Inline Meters Install this product to the racks frame via the mounting plate holes found at either end of the PDU using the provided mounting hardware. The mounting plate can be adjusted as shown below. - 12 -

Optional Accessories Temperature Sensor External Temperature Sensor Humidity Sensor Temperature/Humidity Sensor Water Contact Sensor Water Rope Sensor Air Flow Sensor Shock Sensor Digital Input Sensor Passive Infra-Red (PIR) Sensor Door Contact (micro switch) Door Contact (magnetic) Standard Electronic Swing Handle Kit Smoke Detector Differential Pressure Transducer Flashing Beacon with Sounder Flashing Beacon with no Sounder HID Access and Control Card Reader Keypad Kit LCD Display Module with Selector Switches (PCB only) External LCD Display - 13 -

Additional Required Items Flathead and Phillips screwdrivers Appropriate local AC power receptacle to power the PDU Local active Ethernet port to communicate with the PDU Safety Precautions This section contains important safety and regulatory information that should be reviewed before installing and using the Rack PDU. Servicing There are no user-serviceable parts inside these products. Any maintenance or repair must be performed by approved service-trained personnel. Opening the unit will void the product warranty. Product Safety Warnings Warning: Use only in dry locations. Indoor use only. PDU hardware has an International Protection Rating of IPX0. The installer must connect the power distribution unit to an electrical supply that has a protective Earth conductor. For pluggable equipment, the socket outlet should be installed near the equipment and should be easily accessible. Warning: For permanently connected equipment, a readily accessible disconnect device should be incorporated external to the equipment. Rack PDUs must be protected by a branch circuit protective device rated at the maximum rating of the product specified on the product rating label. To avoid risk of overload, do not plug additional multiple outlet power distribution devices into the power distribution unit socket outlets. This equipment is intended only for installation and use in a Service Access Location in accordance with the following installation and use instructions. This equipment is designed to be installed on a dedicated circuit. - 14 -

The dedicated circuit must have circuit-breaker or fuse protection. Rack PDUs have been designed without a master circuit breaker or fuse to avoid becoming a single point of failure. It is the customer s responsibility to provide adequate protection for the dedicated power circuit. Protection of capacity equal to the current rating of the Rack PDU must be provided and must meet all applicable codes and regulations. In North America, protection must have a 10,000A interrupt capacity. Warning: Always disconnect the power supply cord before opening to avoid electrical shock. DANGER: High leakage current! Ground connection is essential before connecting supply! DANGER: Double Pole/Neutral Fusing: The plug on the power supply cord must be installed near the equipment and must be easily accessible. Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes/modifications not approved by the responsible party could void the user s authority to operate the equipment. - 15 -

Environmental Specifications Operating Temperature: 0C to 40C Transportation Temperature: -10C to 70C Operating Humidity: 15% to 85% non-condensing Transportation Humidity: 5% to 90% non-condensing Bonding This product contains an external earthing screw with a star washer, which should be used for supplementary Earth bonding to the rack metalwork. Bonding Minimum Requirements for Bonding Conductors Up to and including 32A 12 AWG Up to and including 63A 8 AWG Up to and including 80A 6 AWG Screw Size Over 16A, less than or equal to 40A 5mm Over 40A, less than or equal to 63A 6mm 64A 7mm - 16 -

Hardware LCD Display The display shows the firmware version number, device model number, serial number, MAC Address, IP Address, and electrical readings. The display automatically scrolls through the readings, which include: Start Up messages Configuration/serial/product number messages Error/Status messages Aggregate data Single Phase data, 3-Phase Delta data, or 3-Phase Wye data Branch current data (if the unit has breakers) During normal operation, the mode button may be used to quickly advance through the LCD display pages. Reset Button Push the Reset button using a non-metallic item, similar in size to a paper clip, to reset the PDU device. tool. Warning: a metallic item, such as a paper clip, is not recommended as a reset The reset tool should be inserted perpendicular to the surface of the device and pressed until the button is reached and is actuated. The reset tool should bump into the button within 1/8 of an inch of being inserted, and should be lightly depressed and held for at least 1 second. The reset tool should never be inserted more than 1/4 of an inch. Resetting the PDU device starts the bootloader. Wait between 1 and 30 seconds for the Display Backlight to blink on and off at a rate of 2 blinks per second. The bootloader stays in this mode for at least 4 seconds (8 blinks) if no user operation is detected. - 17 -

Mode Button Operation Bootloader Startup When the user presses and holds the Mode button, the Display Backlight switches to one blink per second, indicating the bootloader is waiting for one of the following operations. If the user releases the Mode button after two blinks, the backlight goes solid-on and stays in the bootloader, entering the firmware recovery mode. See the "Firmware Recovery Mode" section (below) for more details. If the user releases the Mode button after four blinks, the backlight goes solid-on and attempts to boot the backup firmware image. If the user does not operate the Mode button as described above, the Display Backlight is turned off. The firmware updatable application image continues loading. Firmware Recovery Mode The Gateway-Enabled PDU provides a firmware recovery mode in case a firmware update is interrupted while in progress and fails to complete successfully. Note: Do not power cycle or restart a device while a firmware update is in progress. If a firmware update does not complete successfully, and the device fails to be operational after 30 minutes, contact Panduit Technical Support. 1-866-721-5302 (toll-free) Monday-Friday, 7:30 am - 5:00 pm CST systemsupport@panduit.com Application Startup When the application is ready, a message is displayed on the LCD: Starting up The display backlight blinks quickly three times and remains lit. The LCD then displays: Hold MODE button to reset to defaults... - 18 -

The application stays in this mode for at least five seconds. If no button operation is detected, the application continues to normal system operation. If the customer presses and holds the Mode button for five seconds, the following message displays on the LCD: Hold MODE button more than 5 seconds to reset to defaults If the customer continues to press and hold the Mode button, the following message displays on the LCD: Reset to defaults is detected. Please release MODE button. The customer should release the Mode button at this point. The following message displays on the LCD: Device is Resetting to factory defaults. If the customer does not operate the Mode button as described above, the application continues normal system operation. Internal Error Notification After system start up is complete, the LCD screen may blink during normal operation of the unit. This typically indicates a temporary or persistent internal error condition. If the condition is persistent, the LCD screen displays the word "STATUS:" followed by a hexadecimal code, similar to the following. STATUS: 0x009000080 The hexadecimal code is a composition of per-outlet control, per-outlet monitoring and per-phase monitoring status. For example, if a three phase Per-outlet Monitoring or Switched unit loses a power phase, the status screen will reflect that communication to those boards has been lost. For definitions and recommended actions on status codes, provide the displayed hexadecimal number to Panduit Technical Support. - 19 -

Gateway User Interface The SmartZone Gateway-Enabled Rack PDU provides access to configuration, power, and sensor data through the Gateway Graphical User Interface (GUI), using a standard browser. There are several ways to connect to the device's Gateway GUI, depending on your network configuration and the firmware revision of the device. If the PDU has firmware revision 2.3.03 (or earlier), Static IP is the default. The configuration settings in this case are: IPv4 Address:192.168.0.253 IPv4 Network:255.255.255.0 IPv4 Gateway:192.168.0.1 If the device has firmware revision 2.3.04 (or later), DHCP is the default, and one of the following scenarios will be used. If you have a DHCP Server available, connect to the appliance through that server, using the PDU's IP Address. Note: The IP address for the Rack PDU is displayed on the device's LCD screen after the label IPv4 If you do not have a DHCP server, you can run one on your PC. To connect to the device, use the IP address displayed on the LCD screen. If you want to use automatic IPv4 address configuration, you must activate DHCP on your PC and then connect directly to the PDU. This will give you an address on the 169.254.0.0/16 network. You can then connect directly using the IP Address displayed on the LCD screen. Access the PDU Graphical User Interface To access the GUI, open a web browser and enter the IP Address of the PDU. When the login page opens, you will be prompted to enter a login and password. - 20 -

The default login and password are: Login:admin Password:admin After successful login, the GUI opens to the Overview page. Using the PDU Graphical User Interface For detailed information on working with the GUI, refer to the appropriate SmartZone Gateway User Manual: SmartZone E24 Gateway User Manual SmartZone EP042 Gateway User Manual SmartZone EPA064 Gateway User Manual SmartZone EPA126 Gateway User Manual - 21 -

Appendix A - Temperature Sensor Adapter Installation Follow the instructions below to install the ZAHTLADT-02 v1.01.01 temperature sensor adapter module. This adapter allows legacy sensors to provide more accurate temperature readings. Note: This adapter does not work with the ZETHL-14 temperature sensor. New Installations Follow these instructions when you are installing a standard temperature sensor, but the upgraded sensor input is required. 1. Plug the adapter directly into the back of the gateway, at the sensor port to be used for temperature. 2. Plug the temperature sensor connector into the adapter. 3. Update the gateway firmware to the latest release. See "Hardware" for details. - 22 -

Existing Installations. Follow these instructions when the sensor is already installed along with the gateway. 1. Unplug the current temperature sensor from the gateway, noting the location where it resided. 2. Insert the adapter into that location. 3. Plug the sensor into the end of the adapter. 4. Perform these steps for all other temperature sensors to be changed. 5. The gateway firmware must be updated to the latest firmware. See "Hardware" for details. Before the adapter is fitted: After the adapter is fitted: Fitting the Adapter In-line. This procedure is not recommended, but it may be the only solution in some cases. - 23 -

1. Using a patch lead from the gateway and an RJ45 Jack to Jack through connector on its non-gateway end, plug the adapter RJ45 Plug into the through connector. 2. Plug either the RJ45 plug of a temperature sensor into the jack on the adapter or a patch lead with the temperature sensor on the end. - 24 -